Action not permitted
Modal body text goes here.
cve-2024-23799
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-017796.html | Mitigation, Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-017796.html | Mitigation, Patch, Vendor Advisory |
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | Tecnomatix Plant Simulation V2201 |
Version: 0 < * |
||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-23799", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-02-13T16:06:28.614005Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-05T17:20:54.041Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T23:13:08.426Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2201", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "lessThan": "V2302.0007", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition." } ], "metrics": [ { "cvssV3_1": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-02-13T09:00:14.553Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-23799", "datePublished": "2024-02-13T09:00:14.553Z", "dateReserved": "2024-01-22T10:34:49.956Z", "dateUpdated": "2024-08-01T23:13:08.426Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-23799\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-02-13T09:15:48.380\",\"lastModified\":\"2024-11-21T08:58:26.700\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones), Tecnomatix Plant Simulation V2302 (Todas las versiones \u0026lt; V2302.0007). Las aplicaciones afectadas contienen una vulnerabilidad de desreferencia de puntero nulo al analizar archivos SPP especialmente manipulados. Un atacante podr\u00eda aprovechar esta vulnerabilidad para bloquear la aplicaci\u00f3n y provocar una condici\u00f3n de denegaci\u00f3n de servicio.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-476\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2302.0\",\"versionEndExcluding\":\"2302.0007\",\"matchCriteriaId\":\"F1CA9BCC-60B4-44F3-9D13-82EE1E3D834A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix_plant_simulation:2201.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"ACE93AE4-565D-40A2-9954-DA02442AEDD1\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-017796.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-017796.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}" } }
icsa-24-046-07
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Siemens Tecnomatix Plant Simulation contains multiple file parsing vulnerabilities that could be triggered when the application reads files in WRL, PSOBJ or SPP file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-017796: Multiple File Parsing Vulnerabilities in Tecnomatix Plant Simulation - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-017796.json" }, { "category": "self", "summary": "SSA-017796: Multiple File Parsing Vulnerabilities in Tecnomatix Plant Simulation - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html" }, { "category": "self", "summary": "SSA-017796: Multiple File Parsing Vulnerabilities in Tecnomatix Plant Simulation - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-017796.pdf" }, { "category": "self", "summary": "SSA-017796: Multiple File Parsing Vulnerabilities in Tecnomatix Plant Simulation - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-017796.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-046-07 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-046-07.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-046-07 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-07" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Tecnomatix Plant Simulation", "tracking": { "current_release_date": "2024-02-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-046-07", "initial_release_date": "2024-02-13T00:00:00.000000Z", "revision_history": [ { "date": "2024-02-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2201.0012", "product": { "name": "Tecnomatix Plant Simulation V2201", "product_id": "CSAFPID-0001" } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Tecnomatix Plant Simulation V2201", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Tecnomatix Plant Simulation V2201" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2302.0006", "product": { "name": "Tecnomatix Plant Simulation V2302", "product_id": "CSAFPID-0003" } }, { "category": "product_version_range", "name": "\u003cV2302.0007", "product": { "name": "Tecnomatix Plant Simulation V2302", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Tecnomatix Plant Simulation V2302" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-23795", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2024-23795" }, { "cve": "CVE-2024-23796", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2024-23796" }, { "cve": "CVE-2024-23797", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected applications contain a stack overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2024-23797" }, { "cve": "CVE-2024-23798", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected applications contain a stack overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2024-23798" }, { "cve": "CVE-2024-23799", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "CSAFPID-0002", "CSAFPID-0004" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V2302.0007 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2024-23799" }, { "cve": "CVE-2024-23800", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "CSAFPID-0002", "CSAFPID-0004" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V2302.0007 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2024-23800" }, { "cve": "CVE-2024-23801", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "CSAFPID-0002", "CSAFPID-0004" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V2302.0007 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2024-23801" }, { "cve": "CVE-2024-23802", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2024-23802" }, { "cve": "CVE-2024-23803", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0002", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "CSAFPID-0002", "CSAFPID-0004" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V2302.0007 or later version", "product_ids": [ "CSAFPID-0004" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0002", "CSAFPID-0004" ] } ], "title": "CVE-2024-23803" }, { "cve": "CVE-2024-23804", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected applications contain a stack overflow vulnerability while parsing specially crafted PSOBJ files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "CSAFPID-0003" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0003" ] } ], "title": "CVE-2024-23804" } ] }
ssa-017796
Vulnerability from csaf_siemens
Notes
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Siemens Tecnomatix Plant Simulation contains multiple file parsing vulnerabilities that could be triggered when the application reads files in WRL, PSOBJ or SPP file formats. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-017796: Multiple File Parsing Vulnerabilities in Tecnomatix Plant Simulation - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html" }, { "category": "self", "summary": "SSA-017796: Multiple File Parsing Vulnerabilities in Tecnomatix Plant Simulation - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-017796.json" }, { "category": "self", "summary": "SSA-017796: Multiple File Parsing Vulnerabilities in Tecnomatix Plant Simulation - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-017796.pdf" }, { "category": "self", "summary": "SSA-017796: Multiple File Parsing Vulnerabilities in Tecnomatix Plant Simulation - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-017796.txt" } ], "title": "SSA-017796: Multiple File Parsing Vulnerabilities in Tecnomatix Plant Simulation", "tracking": { "current_release_date": "2024-02-13T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-017796", "initial_release_date": "2024-02-13T00:00:00Z", "revision_history": [ { "date": "2024-02-13T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2201.0012", "product": { "name": "Tecnomatix Plant Simulation V2201", "product_id": "1" } }, { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Tecnomatix Plant Simulation V2201", "product_id": "2" } } ], "category": "product_name", "name": "Tecnomatix Plant Simulation V2201" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2302.0006", "product": { "name": "Tecnomatix Plant Simulation V2302", "product_id": "3" } }, { "category": "product_version_range", "name": "\u003cV2302.0007", "product": { "name": "Tecnomatix Plant Simulation V2302", "product_id": "4" } } ], "category": "product_name", "name": "Tecnomatix Plant Simulation V2302" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-23795", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "1", "3" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "1" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "3" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3" ] } ], "title": "CVE-2024-23795" }, { "cve": "CVE-2024-23796", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "1", "3" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "1" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "3" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3" ] } ], "title": "CVE-2024-23796" }, { "cve": "CVE-2024-23797", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected applications contain a stack overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "1", "3" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "1" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "3" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3" ] } ], "title": "CVE-2024-23797" }, { "cve": "CVE-2024-23798", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected applications contain a stack overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "1", "3" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "1" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "3" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3" ] } ], "title": "CVE-2024-23798" }, { "cve": "CVE-2024-23799", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "4" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "2", "4" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V2302.0007 or later version", "product_ids": [ "4" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "4" ] } ], "title": "CVE-2024-23799" }, { "cve": "CVE-2024-23800", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "4" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "2", "4" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V2302.0007 or later version", "product_ids": [ "4" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "4" ] } ], "title": "CVE-2024-23800" }, { "cve": "CVE-2024-23801", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "4" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "2", "4" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V2302.0007 or later version", "product_ids": [ "4" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "4" ] } ], "title": "CVE-2024-23801" }, { "cve": "CVE-2024-23802", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "1", "3" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "1" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "3" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3" ] } ], "title": "CVE-2024-23802" }, { "cve": "CVE-2024-23803", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "2", "4" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "2", "4" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V2302.0007 or later version", "product_ids": [ "4" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "2", "4" ] } ], "title": "CVE-2024-23803" }, { "cve": "CVE-2024-23804", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected applications contain a stack overflow vulnerability while parsing specially crafted PSOBJ files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted WRL, PSOBJ, or SPP files from using Tecnomatix Plant Simulation", "product_ids": [ "1", "3" ] }, { "category": "vendor_fix", "details": "Update to V2201.0012 or later version", "product_ids": [ "1" ], "url": "https://support.sw.siemens.com/" }, { "category": "vendor_fix", "details": "Update to V2302.0006 or later version", "product_ids": [ "3" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "3" ] } ], "title": "CVE-2024-23804" } ] }
gsd-2024-23799
Vulnerability from gsd
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2024-23799" ], "details": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "id": "GSD-2024-23799", "modified": "2024-01-23T06:02:22.112813Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2024-23799", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Tecnomatix Plant Simulation V2201", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "*" } ] } }, { "product_name": "Tecnomatix Plant Simulation V2302", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V2302.0007" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition." } ] }, "impact": { "cvss": [ { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-476", "lang": "eng", "value": "CWE-476: NULL Pointer Dereference" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html" } ] } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1CA9BCC-60B4-44F3-9D13-82EE1E3D834A", "versionEndExcluding": "2302.0007", "versionStartIncluding": "2302.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:2201.0:-:*:*:*:*:*:*", "matchCriteriaId": "ACE93AE4-565D-40A2-9954-DA02442AEDD1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones), Tecnomatix Plant Simulation V2302 (Todas las versiones \u0026lt; V2302.0007). Las aplicaciones afectadas contienen una vulnerabilidad de desreferencia de puntero nulo al analizar archivos SPP especialmente manipulados. Un atacante podr\u00eda aprovechar esta vulnerabilidad para bloquear la aplicaci\u00f3n y provocar una condici\u00f3n de denegaci\u00f3n de servicio." } ], "id": "CVE-2024-23799", "lastModified": "2024-02-13T19:22:01.760", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 3.3, "baseSeverity": "LOW", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 1.4, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2024-02-13T09:15:48.380", "references": [ { "source": "productcert@siemens.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "productcert@siemens.com", "type": "Primary" } ] } } } }
ghsa-7m32-w789-g7x4
Vulnerability from github
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
{ "affected": [], "aliases": [ "CVE-2024-23799" ], "database_specific": { "cwe_ids": [ "CWE-476" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2024-02-13T09:15:48Z", "severity": "LOW" }, "details": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "id": "GHSA-7m32-w789-g7x4", "modified": "2024-02-13T09:30:33Z", "published": "2024-02-13T09:30:33Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-23799" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "type": "CVSS_V3" } ] }
var-202402-1320
Vulnerability from variot
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. Siemens' Tecnomatix Plant Simulation for, NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202402-1320", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "tecnomatix plant simulation", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2201.0" }, { "model": "tecnomatix plant simulation", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2302.0007" }, { "model": "tecnomatix plant simulation", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "2302.0" }, { "model": "tecnomatix plant simulation", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "2201.0" }, { "model": "tecnomatix plant simulation", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "2302.0 that\u0027s all 2302.0007" }, { "model": "tecnomatix plant simulation", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "tecnomatix plant simulation", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-002579" }, { "db": "NVD", "id": "CVE-2024-23799" } ] }, "cve": "CVE-2024-23799", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 1.8, "id": "CVE-2024-23799", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "productcert@siemens.com", "availabilityImpact": "LOW", "baseScore": 3.3, "baseSeverity": "LOW", "confidentialityImpact": "NONE", "exploitabilityScore": 1.8, "id": "CVE-2024-23799", "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 5.5, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2024-23799", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2024-23799", "trust": 1.0, "value": "MEDIUM" }, { "author": "productcert@siemens.com", "id": "CVE-2024-23799", "trust": 1.0, "value": "LOW" }, { "author": "NVD", "id": "CVE-2024-23799", "trust": 0.8, "value": "Medium" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-002579" }, { "db": "NVD", "id": "CVE-2024-23799" }, { "db": "NVD", "id": "CVE-2024-23799" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. Siemens\u0027 Tecnomatix Plant Simulation for, NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2024-23799" }, { "db": "JVNDB", "id": "JVNDB-2024-002579" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-23799", "trust": 2.6 }, { "db": "SIEMENS", "id": "SSA-017796", "trust": 1.8 }, { "db": "JVN", "id": "JVNVU91198149", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-24-046-07", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2024-002579", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-002579" }, { "db": "NVD", "id": "CVE-2024-23799" } ] }, "id": "VAR-202402-1320", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.2690208 }, "last_update_date": "2024-08-14T12:49:08.080000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-476", "trust": 1.0 }, { "problemtype": "NULL Pointer dereference (CWE-476) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-002579" }, { "db": "NVD", "id": "CVE-2024-23799" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91198149/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-23799" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-07" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-002579" }, { "db": "NVD", "id": "CVE-2024-23799" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2024-002579" }, { "db": "NVD", "id": "CVE-2024-23799" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-02-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2024-002579" }, { "date": "2024-02-13T09:15:48.380000", "db": "NVD", "id": "CVE-2024-23799" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-02-21T01:48:00", "db": "JVNDB", "id": "JVNDB-2024-002579" }, { "date": "2024-02-13T19:22:01.760000", "db": "NVD", "id": "CVE-2024-23799" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens\u0027 \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 In \u00a0NULL\u00a0 Pointer dereference vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2024-002579" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.