cve-2024-12672
Vulnerability from cvelistv5
Published
2024-12-19 20:58
Modified
2024-12-20 17:14
Severity ?
EPSS score ?
Summary
A third-party vulnerability exists in the Rockwell Automation Arena® that could allow a threat actor to write beyond the boundaries of allocated memory in a DOE file. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Rockwell Automation | Arena® |
Version: All versions 16.20.06 and prior |
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-12672", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-12-20T17:12:24.753276Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-20T17:14:12.572Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Arena\u00ae", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "All versions 16.20.06 and prior" } ] } ], "datePublic": "2024-12-19T14:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA third-party vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae\u0026nbsp;that could allow a threat actor to write beyond the boundaries of allocated memory in a DOE file. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor. \u003c/span\u003e\n\n\n\n\u003c/span\u003e" } ], "value": "A third-party vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae\u00a0that could allow a threat actor to write beyond the boundaries of allocated memory in a DOE file. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "baseScore": 8.5, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "PASSIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-19T20:58:33.406Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1713.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u003cb\u003eMitigations and Workarounds\u003c/b\u003e\u003cbr\u003eCustomers using the affected software are encouraged to apply these risk mitigations, if possible.\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u0026nbsp; \u0026nbsp; \u0026nbsp; Do not load untrusted Arena\u00ae model files.\u003c/li\u003e\u003cli\u003e\u0026nbsp; \u0026nbsp; \u0026nbsp; Hold the control key down when loading files to help prevent the VBA file stream from loading.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "Mitigations and Workarounds\nCustomers using the affected software are encouraged to apply these risk mitigations, if possible.\n\n * \u00a0 \u00a0 \u00a0 Do not load untrusted Arena\u00ae model files.\n * \u00a0 \u00a0 \u00a0 Hold the control key down when loading files to help prevent the VBA file stream from loading." } ], "source": { "advisory": "SD1713", "discovery": "EXTERNAL" }, "title": "Rockwell Automation Third Party Vulnerability in Arena\u00ae", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2024-12672", "datePublished": "2024-12-19T20:58:29.049Z", "dateReserved": "2024-12-16T15:33:54.996Z", "dateUpdated": "2024-12-20T17:14:12.572Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-12672\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-12-19T21:15:07.627\",\"lastModified\":\"2024-12-20T18:15:27.537\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A third-party vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae\u00a0that could allow a threat actor to write beyond the boundaries of allocated memory in a DOE file. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de terceros en Rockwell Automation Arena\u00ae que podr\u00eda permitir que un actor de amenazas escriba m\u00e1s all\u00e1 de los l\u00edmites de la memoria asignada en un archivo DOE. Si se explota, un actor de amenazas podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo arbitrario. Para explotar esta vulnerabilidad, un usuario leg\u00edtimo debe ejecutar el c\u00f3digo malicioso manipulado por el actor de amenazas.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"PASSIVE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"HIGH\",\"vulnerableSystemAvailability\":\"HIGH\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1713.html\",\"source\":\"PSIRT@rockwellautomation.com\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.