cve-2024-0865
Vulnerability from cvelistv5
Published
2024-06-12 17:23
Modified
2024-08-01 18:18
Severity ?
EPSS score ?
Summary
CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege
escalation when logged in as a non-administrative user.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Schneider Electric | EcoStruxure IT Gateway |
Version: 1.20.x and prior |
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ecostruxure_it_gateway", "vendor": "schneider-electric", "versions": [ { "lessThan": "1.20.x", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-0865", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-06-12T19:59:08.710375Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-12T20:04:39.540Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T18:18:18.824Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-03.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "EcoStruxure IT Gateway", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "1.20.x and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege\nescalation when logged in as a non-administrative user." } ], "value": "CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege\nescalation when logged in as a non-administrative user." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798 Use of Hard-coded Credentials", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-12T17:23:00.908Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-03.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2024-0865", "datePublished": "2024-06-12T17:23:00.908Z", "dateReserved": "2024-01-24T17:18:07.117Z", "dateUpdated": "2024-08-01T18:18:18.824Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-0865\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2024-06-12T18:15:10.620\",\"lastModified\":\"2024-11-21T08:47:32.170\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-798: Use of hard-coded credentials vulnerability exists that could cause local privilege\\nescalation when logged in as a non-administrative user.\"},{\"lang\":\"es\",\"value\":\"CWE-798: Existe una vulnerabilidad en el uso de credenciales codificadas que podr\u00eda provocar una escalada de privilegios locales al iniciar sesi\u00f3n como usuario no administrativo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_it_gateway:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.21.0\",\"matchCriteriaId\":\"2DEDCABF-3AD9-4627-BA56-019AAF0D0062\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-03.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-03.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.