Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2023-52238
Vulnerability from cvelistv5
Published
2024-07-09 12:04
Modified
2024-08-02 22:55
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in RUGGEDCOM RST2228 (All versions < V5.9.0), RUGGEDCOM RST2228P (All versions < V5.9.0). The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients.
References
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | RUGGEDCOM RST2228 |
Version: 0 < V5.9.0 |
||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-52238", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-15T21:30:22.503826Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-15T21:30:31.915Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T22:55:41.449Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-170375.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "RUGGEDCOM RST2228", "vendor": "Siemens", "versions": [ { "lessThan": "V5.9.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RST2228P", "vendor": "Siemens", "versions": [ { "lessThan": "V5.9.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in RUGGEDCOM RST2228 (All versions \u003c V5.9.0), RUGGEDCOM RST2228P (All versions \u003c V5.9.0). The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 2.3, "baseSeverity": "LOW", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:04:40.975Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-170375.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-52238", "datePublished": "2024-07-09T12:04:40.975Z", "dateReserved": "2023-12-29T16:54:27.071Z", "dateUpdated": "2024-08-02T22:55:41.449Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-52238\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-07-09T12:15:11.030\",\"lastModified\":\"2024-11-21T08:39:27.907\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in RUGGEDCOM RST2228 (All versions \u003c V5.9.0), RUGGEDCOM RST2228P (All versions \u003c V5.9.0). The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en RUGGEDCOM RST2228 (Todas las versiones \u0026lt; V5.9.0), RUGGEDCOM RST2228P (Todas las versiones \u0026lt; V5.9.0). El servidor web de los sistemas afectados filtra la clave MACSEC en texto claro a un usuario que ha iniciado sesi\u00f3n. Un atacante con las credenciales de un usuario con pocos privilegios podr\u00eda recuperar la clave MACSEC y acceder (descifrar) las tramas Ethernet enviadas por destinatarios autorizados.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":2.3,\"baseSeverity\":\"LOW\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"LOW\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"NONE\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-170375.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-170375.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
gsd-2023-52238
Vulnerability from gsd
Modified
2023-12-30 06:01
Details
** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-52238" ], "id": "GSD-2023-52238", "modified": "2023-12-30T06:01:43.917462Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2023-52238", "STATE": "RESERVED" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." } ] } } } }
ssa-170375
Vulnerability from csaf_siemens
Published
2024-07-09 00:00
Modified
2024-07-09 00:00
Summary
SSA-170375: Multiple Vulnerabilities in RUGGEDCOM ROS before V5.9
Notes
Summary
Multiple vulnerabilities affect the RUGGEDCOM Operating System (ROS). The common denominator to all vulnerabilities is the leak of confidential information.
Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Multiple vulnerabilities affect the RUGGEDCOM Operating System (ROS). The common denominator to all vulnerabilities is the leak of confidential information.\n\nSiemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-170375: Multiple Vulnerabilities in RUGGEDCOM ROS before V5.9 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-170375.html" }, { "category": "self", "summary": "SSA-170375: Multiple Vulnerabilities in RUGGEDCOM ROS before V5.9 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-170375.json" }, { "category": "self", "summary": "SSA-170375: Multiple Vulnerabilities in RUGGEDCOM ROS before V5.9 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170375.pdf" }, { "category": "self", "summary": "SSA-170375: Multiple Vulnerabilities in RUGGEDCOM ROS before V5.9 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-170375.txt" } ], "title": "SSA-170375: Multiple Vulnerabilities in RUGGEDCOM ROS before V5.9", "tracking": { "current_release_date": "2024-07-09T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-170375", "initial_release_date": "2024-07-09T00:00:00Z", "revision_history": [ { "date": "2024-07-09T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i800", "product_id": "1" } } ], "category": "product_name", "name": "RUGGEDCOM i800" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i800NC", "product_id": "2" } } ], "category": "product_name", "name": "RUGGEDCOM i800NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i801", "product_id": "3" } } ], "category": "product_name", "name": "RUGGEDCOM i801" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i801NC", "product_id": "4" } } ], "category": "product_name", "name": "RUGGEDCOM i801NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i802", "product_id": "5" } } ], "category": "product_name", "name": "RUGGEDCOM i802" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i802NC", "product_id": "6" } } ], "category": "product_name", "name": "RUGGEDCOM i802NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i803", "product_id": "7" } } ], "category": "product_name", "name": "RUGGEDCOM i803" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i803NC", "product_id": "8" } } ], "category": "product_name", "name": "RUGGEDCOM i803NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M969", "product_id": "9" } } ], "category": "product_name", "name": "RUGGEDCOM M969" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M969NC", "product_id": "10" } } ], "category": "product_name", "name": "RUGGEDCOM M969NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M2100", "product_id": "11" } } ], "category": "product_name", "name": "RUGGEDCOM M2100" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M2100NC", "product_id": "12" } } ], "category": "product_name", "name": "RUGGEDCOM M2100NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M2200", "product_id": "13" } } ], "category": "product_name", "name": "RUGGEDCOM M2200" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M2200NC", "product_id": "14" } } ], "category": "product_name", "name": "RUGGEDCOM M2200NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RMC30", "product_id": "15" } } ], "category": "product_name", "name": "RUGGEDCOM RMC30" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RMC30NC", "product_id": "16" } } ], "category": "product_name", "name": "RUGGEDCOM RMC30NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RMC8388 V4.X", "product_id": "17" } } ], "category": "product_name", "name": "RUGGEDCOM RMC8388 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RMC8388 V5.X", "product_id": "18" } } ], "category": "product_name", "name": "RUGGEDCOM RMC8388 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RMC8388NC V4.X", "product_id": "19" } } ], "category": "product_name", "name": "RUGGEDCOM RMC8388NC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RMC8388NC V5.X", "product_id": "20" } } ], "category": "product_name", "name": "RUGGEDCOM RMC8388NC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RP110", "product_id": "21" } } ], "category": "product_name", "name": "RUGGEDCOM RP110" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RP110NC", "product_id": "22" } } ], "category": "product_name", "name": "RUGGEDCOM RP110NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS400", "product_id": "23" } } ], "category": "product_name", "name": "RUGGEDCOM RS400" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS400NC", "product_id": "24" } } ], "category": "product_name", "name": "RUGGEDCOM RS400NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS401", "product_id": "25" } } ], "category": "product_name", "name": "RUGGEDCOM RS401" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS401NC", "product_id": "26" } } ], "category": "product_name", "name": "RUGGEDCOM RS401NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416", "product_id": "27" } } ], "category": "product_name", "name": "RUGGEDCOM RS416" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416NC", "product_id": "28" } } ], "category": "product_name", "name": "RUGGEDCOM RS416NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416NCv2 V4.X", "product_id": "29" } } ], "category": "product_name", "name": "RUGGEDCOM RS416NCv2 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS416NCv2 V5.X", "product_id": "30" } } ], "category": "product_name", "name": "RUGGEDCOM RS416NCv2 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416P", "product_id": "31" } } ], "category": "product_name", "name": "RUGGEDCOM RS416P" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416PNC", "product_id": "32" } } ], "category": "product_name", "name": "RUGGEDCOM RS416PNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416PNCv2 V4.X", "product_id": "33" } } ], "category": "product_name", "name": "RUGGEDCOM RS416PNCv2 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS416PNCv2 V5.X", "product_id": "34" } } ], "category": "product_name", "name": "RUGGEDCOM RS416PNCv2 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416Pv2 V4.X", "product_id": "35" } } ], "category": "product_name", "name": "RUGGEDCOM RS416Pv2 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS416Pv2 V5.X", "product_id": "36" } } ], "category": "product_name", "name": "RUGGEDCOM RS416Pv2 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416v2 V4.X", "product_id": "37" } } ], "category": "product_name", "name": "RUGGEDCOM RS416v2 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS416v2 V5.X", "product_id": "38" } } ], "category": "product_name", "name": "RUGGEDCOM RS416v2 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900", "product_id": "39" } } ], "category": "product_name", "name": "RUGGEDCOM RS900" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900 (32M) V4.X", "product_id": "40" } } ], "category": "product_name", "name": "RUGGEDCOM RS900 (32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS900 (32M) V5.X", "product_id": "41" } } ], "category": "product_name", "name": "RUGGEDCOM RS900 (32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900G", "product_id": "42" } } ], "category": "product_name", "name": "RUGGEDCOM RS900G" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900G (32M) V4.X", "product_id": "43" } } ], "category": "product_name", "name": "RUGGEDCOM RS900G (32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS900G (32M) V5.X", "product_id": "44" } } ], "category": "product_name", "name": "RUGGEDCOM RS900G (32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900GNC", "product_id": "45" } } ], "category": "product_name", "name": "RUGGEDCOM RS900GNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900GNC(32M) V4.X", "product_id": "46" } } ], "category": "product_name", "name": "RUGGEDCOM RS900GNC(32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS900GNC(32M) V5.X", "product_id": "47" } } ], "category": "product_name", "name": "RUGGEDCOM RS900GNC(32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900GP", "product_id": "48" } } ], "category": "product_name", "name": "RUGGEDCOM RS900GP" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900GPNC", "product_id": "49" } } ], "category": "product_name", "name": "RUGGEDCOM RS900GPNC" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS900L", "product_id": "50" } } ], "category": "product_name", "name": "RUGGEDCOM RS900L" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS900LNC", "product_id": "51" } } ], "category": "product_name", "name": "RUGGEDCOM RS900LNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900M-GETS-C01", "product_id": "52" } } ], "category": "product_name", "name": "RUGGEDCOM RS900M-GETS-C01" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900M-GETS-XX", "product_id": "53" } } ], "category": "product_name", "name": "RUGGEDCOM RS900M-GETS-XX" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900M-STND-C01", "product_id": "54" } } ], "category": "product_name", "name": "RUGGEDCOM RS900M-STND-C01" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900M-STND-XX", "product_id": "55" } } ], "category": "product_name", "name": "RUGGEDCOM RS900M-STND-XX" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900MNC-GETS-C01", "product_id": "56" } } ], "category": "product_name", "name": "RUGGEDCOM RS900MNC-GETS-C01" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900MNC-GETS-XX", "product_id": "57" } } ], "category": "product_name", "name": "RUGGEDCOM RS900MNC-GETS-XX" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900MNC-STND-XX", "product_id": "58" } } ], "category": "product_name", "name": "RUGGEDCOM RS900MNC-STND-XX" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900MNC-STND-XX-C01", "product_id": "59" } } ], "category": "product_name", "name": "RUGGEDCOM RS900MNC-STND-XX-C01" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900NC", "product_id": "60" } } ], "category": "product_name", "name": "RUGGEDCOM RS900NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900NC(32M) V4.X", "product_id": "61" } } ], "category": "product_name", "name": "RUGGEDCOM RS900NC(32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS900NC(32M) V5.X", "product_id": "62" } } ], "category": "product_name", "name": "RUGGEDCOM RS900NC(32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900W", "product_id": "63" } } ], "category": "product_name", "name": "RUGGEDCOM RS900W" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS910", "product_id": "64" } } ], "category": "product_name", "name": "RUGGEDCOM RS910" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS910L", "product_id": "65" } } ], "category": "product_name", "name": "RUGGEDCOM RS910L" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS910LNC", "product_id": "66" } } ], "category": "product_name", "name": "RUGGEDCOM RS910LNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS910NC", "product_id": "67" } } ], "category": "product_name", "name": "RUGGEDCOM RS910NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS910W", "product_id": "68" } } ], "category": "product_name", "name": "RUGGEDCOM RS910W" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS920L", "product_id": "69" } } ], "category": "product_name", "name": "RUGGEDCOM RS920L" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS920LNC", "product_id": "70" } } ], "category": "product_name", "name": "RUGGEDCOM RS920LNC" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS920W", "product_id": "71" } } ], "category": "product_name", "name": "RUGGEDCOM RS920W" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS930L", "product_id": "72" } } ], "category": "product_name", "name": "RUGGEDCOM RS930L" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS930LNC", "product_id": "73" } } ], "category": "product_name", "name": "RUGGEDCOM RS930LNC" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS930W", "product_id": "74" } } ], "category": "product_name", "name": "RUGGEDCOM RS930W" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS940G", "product_id": "75" } } ], "category": "product_name", "name": "RUGGEDCOM RS940G" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS940GNC", "product_id": "76" } } ], "category": "product_name", "name": "RUGGEDCOM RS940GNC" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS969", "product_id": "77" } } ], "category": "product_name", "name": "RUGGEDCOM RS969" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS969NC", "product_id": "78" } } ], "category": "product_name", "name": "RUGGEDCOM RS969NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600", "product_id": "79" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600F", "product_id": "80" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600F" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600FNC", "product_id": "81" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600FNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600NC", "product_id": "82" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600T", "product_id": "83" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600T" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600TNC", "product_id": "84" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600TNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000", "product_id": "85" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000A", "product_id": "86" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000A" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000ANC", "product_id": "87" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000ANC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000H", "product_id": "88" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000H" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000HNC", "product_id": "89" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000HNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000NC", "product_id": "90" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000T", "product_id": "91" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000T" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000TNC", "product_id": "92" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000TNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG907R", "product_id": "93" } } ], "category": "product_name", "name": "RUGGEDCOM RSG907R" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG908C", "product_id": "94" } } ], "category": "product_name", "name": "RUGGEDCOM RSG908C" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG909R", "product_id": "95" } } ], "category": "product_name", "name": "RUGGEDCOM RSG909R" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG910C", "product_id": "96" } } ], "category": "product_name", "name": "RUGGEDCOM RSG910C" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG920P V4.X", "product_id": "97" } } ], "category": "product_name", "name": "RUGGEDCOM RSG920P V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG920P V5.X", "product_id": "98" } } ], "category": "product_name", "name": "RUGGEDCOM RSG920P V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG920PNC V4.X", "product_id": "99" } } ], "category": "product_name", "name": "RUGGEDCOM RSG920PNC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG920PNC V5.X", "product_id": "100" } } ], "category": "product_name", "name": "RUGGEDCOM RSG920PNC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100", "product_id": "101" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100 (32M) V4.X", "product_id": "102" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100 (32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2100 (32M) V5.X", "product_id": "103" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100 (32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100NC", "product_id": "104" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100NC(32M) V4.X", "product_id": "105" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100NC(32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2100NC(32M) V5.X", "product_id": "106" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100NC(32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100P", "product_id": "107" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100P" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100PNC", "product_id": "108" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100PNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2200", "product_id": "109" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2200" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2200NC", "product_id": "110" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2200NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2288 V4.X", "product_id": "111" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2288 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2288 V5.X", "product_id": "112" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2288 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2288NC V4.X", "product_id": "113" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2288NC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2288NC V5.X", "product_id": "114" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2288NC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2300 V4.X", "product_id": "115" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2300 V5.X", "product_id": "116" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2300NC V4.X", "product_id": "117" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300NC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2300NC V5.X", "product_id": "118" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300NC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2300P V4.X", "product_id": "119" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300P V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2300P V5.X", "product_id": "120" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300P V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2300PNC V4.X", "product_id": "121" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300PNC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2300PNC V5.X", "product_id": "122" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300PNC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2488 V4.X", "product_id": "123" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2488 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2488 V5.X", "product_id": "124" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2488 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2488NC V4.X", "product_id": "125" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2488NC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2488NC V5.X", "product_id": "126" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2488NC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSL910", "product_id": "127" } } ], "category": "product_name", "name": "RUGGEDCOM RSL910" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSL910NC", "product_id": "128" } } ], "category": "product_name", "name": "RUGGEDCOM RSL910NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RST916C", "product_id": "129" } } ], "category": "product_name", "name": "RUGGEDCOM RST916C" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RST916P", "product_id": "130" } } ], "category": "product_name", "name": "RUGGEDCOM RST916P" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RST2228", "product_id": "131" } } ], "category": "product_name", "name": "RUGGEDCOM RST2228" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RST2228P", "product_id": "132" } } ], "category": "product_name", "name": "RUGGEDCOM RST2228P" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-52237", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "The web server of the affected devices allow a low privileged user to access hashes and password salts of all system\u0027s users, including admin users. An attacker could use the obtained information to brute force the passwords offline.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5", "6", "7", "8", "11", "12", "13", "14", "9", "10", "15", "16", "17", "18", "19", "20", "21", "22", "79", "80", "81", "82", "83", "84", "23", "24", "25", "26", "27", "28", "29", "30", "31", "32", "33", "34", "35", "36", "37", "38", "85", "86", "87", "88", "89", "90", "91", "92", "39", "40", "41", "42", "43", "44", "45", "46", "47", "48", "49", "50", "51", "52", "53", "54", "55", "56", "57", "58", "59", "60", "61", "62", "63", "64", "65", "66", "67", "68", "69", "70", "71", "72", "73", "74", "75", "76", "77", "78", "101", "102", "103", "104", "105", "106", "107", "108", "109", "110", "111", "112", "113", "114", "115", "116", "117", "118", "119", "120", "121", "122", "123", "124", "125", "126", "93", "94", "95", "96", "97", "98", "99", "100", "127", "128", "131", "132", "129", "130" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "50", "51", "65", "66", "69", "70", "71", "72", "73", "74", "77", "78" ] }, { "category": "vendor_fix", "details": "Update to V4.3.10 or later version", "product_ids": [ "1", "3", "5", "7", "11", "13", "9", "15", "17", "21", "79", "80", "83", "23", "25", "27", "35", "37", "85", "86", "88", "91", "39", "40", "42", "43", "48", "63", "64", "68", "75", "101", "102", "107", "109", "111", "115", "119", "123", "97" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972218/" }, { "category": "vendor_fix", "details": "Update to V4.3.10 or later version", "product_ids": [ "2", "4", "6", "8", "12", "14", "10", "16", "19", "22", "81", "82", "84", "24", "26", "28", "29", "31", "32", "33", "87", "89", "90", "92", "45", "46", "49", "52", "53", "54", "55", "56", "57", "58", "59", "60", "61", "67", "76", "104", "105", "108", "110", "113", "117", "121", "125", "99" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972218/" }, { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "18", "36", "38", "41", "44", "103", "112", "116", "120", "124", "93", "94", "95", "96", "98", "127", "131", "132", "129", "130" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "20", "30", "34", "47", "62", "106", "114", "118", "122", "126", "100", "128" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "workaround", "details": "For CVE-2023-52237, CVE-2023-52238: Disable the webserver if not required on the affected systems. Restrict the access to Port 80/tcp and 443/tcp to trusted IP address only", "product_ids": [ "1", "2", "3", "4", "5", "6", "7", "8", "11", "12", "13", "14", "9", "10", "15", "16", "17", "18", "19", "20", "21", "22", "79", "80", "81", "82", "83", "84", "23", "24", "25", "26", "27", "28", "29", "30", "31", "32", "33", "34", "35", "36", "37", "38", "85", "86", "87", "88", "89", "90", "91", "92", "39", "40", "41", "42", "43", "44", "45", "46", "47", "48", "49", "50", "51", "52", "53", "54", "55", "56", "57", "58", "59", "60", "61", "62", "63", "64", "65", "66", "67", "68", "69", "70", "71", "72", "73", "74", "75", "76", "77", "78", "101", "102", "103", "104", "105", "106", "107", "108", "109", "110", "111", "112", "113", "114", "115", "116", "117", "118", "119", "120", "121", "122", "123", "124", "125", "126", "93", "94", "95", "96", "97", "98", "99", "100", "127", "128", "131", "132", "129", "130" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5", "6", "7", "8", "11", "12", "13", "14", "9", "10", "15", "16", "17", "18", "19", "20", "21", "22", "79", "80", "81", "82", "83", "84", "23", "24", "25", "26", "27", "28", "29", "30", "31", "32", "33", "34", "35", "36", "37", "38", "85", "86", "87", "88", "89", "90", "91", "92", "39", "40", "41", "42", "43", "44", "45", "46", "47", "48", "49", "50", "51", "52", "53", "54", "55", "56", "57", "58", "59", "60", "61", "62", "63", "64", "65", "66", "67", "68", "69", "70", "71", "72", "73", "74", "75", "76", "77", "78", "101", "102", "103", "104", "105", "106", "107", "108", "109", "110", "111", "112", "113", "114", "115", "116", "117", "118", "119", "120", "121", "122", "123", "124", "125", "126", "93", "94", "95", "96", "97", "98", "99", "100", "127", "128", "131", "132", "129", "130" ] } ], "title": "CVE-2023-52237" }, { "cve": "CVE-2023-52238", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients.", "title": "Summary" } ], "product_status": { "known_affected": [ "131", "132" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "131", "132" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "workaround", "details": "For CVE-2023-52237, CVE-2023-52238: Disable the webserver if not required on the affected systems. Restrict the access to Port 80/tcp and 443/tcp to trusted IP address only", "product_ids": [ "131", "132" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "131", "132" ] } ], "title": "CVE-2023-52238" }, { "cve": "CVE-2024-38278", "cwe": { "id": "CWE-266", "name": "Incorrect Privilege Assignment" }, "notes": [ { "category": "summary", "text": "The affected products with IP forwarding enabled wrongly make available certain remote services in non-managed VLANs, even if these services are not intentionally activated. An attacker could leverage this vulnerability to create a remote shell to the affected system.", "title": "Summary" } ], "product_status": { "known_affected": [ "18", "20", "30", "34", "36", "38", "41", "44", "47", "62", "103", "106", "112", "114", "116", "118", "120", "122", "124", "126", "93", "94", "95", "96", "98", "100", "127", "128", "131", "132", "129", "130" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "18", "36", "38", "41", "44", "103", "112", "116", "120", "124", "93", "94", "95", "96", "98", "127", "131", "132", "129", "130" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "20", "30", "34", "47", "62", "106", "114", "118", "122", "126", "100", "128" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "workaround", "details": "For CVE-2024-38278: Disable the IP Forwarding if not required on the affected system. Also note, the IP forwarding is disabled by default", "product_ids": [ "18", "20", "30", "34", "36", "38", "41", "44", "47", "62", "103", "106", "112", "114", "116", "118", "120", "122", "124", "126", "93", "94", "95", "96", "98", "100", "127", "128", "131", "132", "129", "130" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "18", "20", "30", "34", "36", "38", "41", "44", "47", "62", "103", "106", "112", "114", "116", "118", "120", "122", "124", "126", "93", "94", "95", "96", "98", "100", "127", "128", "131", "132", "129", "130" ] } ], "title": "CVE-2024-38278" }, { "cve": "CVE-2024-39675", "cwe": { "id": "CWE-497", "name": "Exposure of Sensitive System Information to an Unauthorized Control Sphere" }, "notes": [ { "category": "summary", "text": "In some configurations the affected products wrongly enable the Modbus service in non-managed VLANS. Only serial devices are affected by this vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "15", "16", "21", "22", "23", "24", "25", "26", "27", "28", "29", "30", "31", "32", "33", "34", "35", "36", "37", "38", "64", "65", "66", "67", "68", "69", "70", "71" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "65", "66", "69", "70", "71" ] }, { "category": "vendor_fix", "details": "Update to V4.3.10 or later version", "product_ids": [ "15", "21", "23", "25", "27", "35", "37", "64", "68" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972218/" }, { "category": "vendor_fix", "details": "Update to V4.3.10 or later version", "product_ids": [ "16", "22", "24", "26", "28", "29", "31", "32", "33", "67" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972218/" }, { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "36", "38" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "30", "34" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "workaround", "details": "For CVE-2024-39675: Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default", "product_ids": [ "15", "16", "21", "22", "23", "24", "25", "26", "27", "28", "29", "30", "31", "32", "33", "34", "35", "36", "37", "38", "64", "65", "66", "67", "68", "69", "70", "71" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "15", "16", "21", "22", "23", "24", "25", "26", "27", "28", "29", "30", "31", "32", "33", "34", "35", "36", "37", "38", "64", "65", "66", "67", "68", "69", "70", "71" ] } ], "title": "CVE-2024-39675" } ] }
ghsa-jfvv-8342-x746
Vulnerability from github
Published
2024-07-09 12:30
Modified
2024-07-09 12:30
Severity ?
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
2.3 (Low) - CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
2.3 (Low) - CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
Details
A vulnerability has been identified in RUGGEDCOM RST2228 (All versions < V5.9.0), RUGGEDCOM RST2228P (All versions < V5.9.0). The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients.
{ "affected": [], "aliases": [ "CVE-2023-52238" ], "database_specific": { "cwe_ids": [ "CWE-200" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2024-07-09T12:15:11Z", "severity": "LOW" }, "details": "A vulnerability has been identified in RUGGEDCOM RST2228 (All versions \u003c V5.9.0), RUGGEDCOM RST2228P (All versions \u003c V5.9.0). The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients.", "id": "GHSA-jfvv-8342-x746", "modified": "2024-07-09T12:30:57Z", "published": "2024-07-09T12:30:57Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-52238" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-170375.html" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "type": "CVSS_V3" }, { "score": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "type": "CVSS_V4" } ] }
ncsc-2024-0282
Vulnerability from csaf_ncscnl
Published
2024-07-09 18:40
Modified
2024-07-09 18:40
Summary
Kwetsbaarheden verholpen in Siemens Producten
Notes
The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:
NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.
NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.
This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings.
Feiten
Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, RUGGEDOM, SIMATIC, SINEMA, SIPROTEC en de Engineering Platforms voor diverse systemen.
Interpretaties
De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorieën schade:
- Denial-of-Service (DoS)
- Manipulatie van gegevens
- (Remote) code execution (Administrator/Root rechten)
- (Remote) code execution (Gebruikersrechten)
- Toegang tot systeemgegevens
- Toegang tot gevoelige gegevens
- Verhoogde gebruikersrechten
De kwaadwillende heeft hiervoor toegang nodig tot de productieomgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.
Oplossingen
Siemens heeft beveiligingsupdates uitgebracht om de kwetsbaarheden te verhelpen. Voor de kwetsbaarheden waar nog geen updates voor zijn, heeft Siemens mitigerende maatregelen gepubliceerd om de risico's zoveel als mogelijk te beperken. Zie de bijgevoegde referenties voor meer informatie.
Kans
medium
Schade
high
CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE-121
Stack-based Buffer Overflow
CWE-125
Out-of-bounds Read
CWE-1325
Improperly Controlled Sequential Memory Allocation
CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE-222
Truncation of Security-relevant Information
CWE-266
Incorrect Privilege Assignment
CWE-267
Privilege Defined With Unsafe Actions
CWE-286
Incorrect User Management
CWE-307
Improper Restriction of Excessive Authentication Attempts
CWE-326
Inadequate Encryption Strength
CWE-359
Exposure of Private Personal Information to an Unauthorized Actor
CWE-378
Creation of Temporary File With Insecure Permissions
CWE-400
Uncontrolled Resource Consumption
CWE-425
Direct Request ('Forced Browsing')
CWE-434
Unrestricted Upload of File with Dangerous Type
CWE-476
NULL Pointer Dereference
CWE-497
Exposure of Sensitive System Information to an Unauthorized Control Sphere
CWE-502
Deserialization of Untrusted Data
CWE-547
Use of Hard-coded, Security-relevant Constants
CWE-602
Client-Side Enforcement of Server-Side Security
CWE-732
Incorrect Permission Assignment for Critical Resource
CWE-754
Improper Check for Unusual or Exceptional Conditions
CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE-770
Allocation of Resources Without Limits or Throttling
CWE-787
Out-of-bounds Write
CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CWE-843
Access of Resource Using Incompatible Type ('Type Confusion')
CWE-863
Incorrect Authorization
CWE-916
Use of Password Hash With Insufficient Computational Effort
CWE-924
Improper Enforcement of Message Integrity During Transmission in a Communication Channel
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE" } }, "lang": "nl", "notes": [ { "category": "legal_disclaimer", "text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings." }, { "category": "description", "text": "Siemens heeft kwetsbaarheden verholpen in diverse producten als Mendix, RUGGEDOM, SIMATIC, SINEMA, SIPROTEC en de Engineering Platforms voor diverse systemen.", "title": "Feiten" }, { "category": "description", "text": "De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorie\u00ebn schade:\n\n- Denial-of-Service (DoS)\n- Manipulatie van gegevens\n- (Remote) code execution (Administrator/Root rechten)\n- (Remote) code execution (Gebruikersrechten)\n- Toegang tot systeemgegevens\n- Toegang tot gevoelige gegevens\n- Verhoogde gebruikersrechten\n\nDe kwaadwillende heeft hiervoor toegang nodig tot de productieomgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.", "title": "Interpretaties" }, { "category": "description", "text": "Siemens heeft beveiligingsupdates uitgebracht om de kwetsbaarheden te verhelpen. Voor de kwetsbaarheden waar nog geen updates voor zijn, heeft Siemens mitigerende maatregelen gepubliceerd om de risico\u0027s zoveel als mogelijk te beperken. Zie de bijgevoegde referenties voor meer informatie.", "title": "Oplossingen" }, { "category": "general", "text": "medium", "title": "Kans" }, { "category": "general", "text": "high", "title": "Schade" }, { "category": "general", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" }, { "category": "general", "text": "Stack-based Buffer Overflow", "title": "CWE-121" }, { "category": "general", "text": "Out-of-bounds Read", "title": "CWE-125" }, { "category": "general", "text": "Improperly Controlled Sequential Memory Allocation", "title": "CWE-1325" }, { "category": "general", "text": "Exposure of Sensitive Information to an Unauthorized Actor", "title": "CWE-200" }, { "category": "general", "text": "Truncation of Security-relevant Information", "title": "CWE-222" }, { "category": "general", "text": "Incorrect Privilege Assignment", "title": "CWE-266" }, { "category": "general", "text": "Privilege Defined With Unsafe Actions", "title": "CWE-267" }, { "category": "general", "text": "Incorrect User Management", "title": "CWE-286" }, { "category": "general", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" }, { "category": "general", "text": "Inadequate Encryption Strength", "title": "CWE-326" }, { "category": "general", "text": "Exposure of Private Personal Information to an Unauthorized Actor", "title": "CWE-359" }, { "category": "general", "text": "Creation of Temporary File With Insecure Permissions", "title": "CWE-378" }, { "category": "general", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" }, { "category": "general", "text": "Direct Request (\u0027Forced Browsing\u0027)", "title": "CWE-425" }, { "category": "general", "text": "Unrestricted Upload of File with Dangerous Type", "title": "CWE-434" }, { "category": "general", "text": "NULL Pointer Dereference", "title": "CWE-476" }, { "category": "general", "text": "Exposure of Sensitive System Information to an Unauthorized Control Sphere", "title": "CWE-497" }, { "category": "general", "text": "Deserialization of Untrusted Data", "title": "CWE-502" }, { "category": "general", "text": "Use of Hard-coded, Security-relevant Constants", "title": "CWE-547" }, { "category": "general", "text": "Client-Side Enforcement of Server-Side Security", "title": "CWE-602" }, { "category": "general", "text": "Incorrect Permission Assignment for Critical Resource", "title": "CWE-732" }, { "category": "general", "text": "Improper Check for Unusual or Exceptional Conditions", "title": "CWE-754" }, { "category": "general", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" }, { "category": "general", "text": "Allocation of Resources Without Limits or Throttling", "title": "CWE-770" }, { "category": "general", "text": "Out-of-bounds Write", "title": "CWE-787" }, { "category": "general", "text": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "title": "CWE-79" }, { "category": "general", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" }, { "category": "general", "text": "Incorrect Authorization", "title": "CWE-863" }, { "category": "general", "text": "Use of Password Hash With Insufficient Computational Effort", "title": "CWE-916" }, { "category": "general", "text": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel", "title": "CWE-924" } ], "publisher": { "category": "coordinator", "contact_details": "cert@ncsc.nl", "name": "Nationaal Cyber Security Centrum", "namespace": "https://www.ncsc.nl/" }, "references": [ { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-064222.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-088132.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170375.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-313039.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364175.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-381581.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-698820.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-722010.pdf" }, { "category": "external", "summary": "Reference - siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-723487.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-750499.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779936.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-824889.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-868282.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-883918.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-928781.pdf" }, { "category": "external", "summary": "Reference - ncscclear; siemens", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-998949.pdf" } ], "title": "Kwetsbaarheden verholpen in Siemens Producten", "tracking": { "current_release_date": "2024-07-09T18:40:57.534939Z", "id": "NCSC-2024-0282", "initial_release_date": "2024-07-09T18:40:57.534939Z", "revision_history": [ { "date": "2024-07-09T18:40:57.534939Z", "number": "0", "summary": "Initiele versie" } ], "status": "final", "version": "1.0.0" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "jt_open", "product": { "name": "jt_open", "product_id": "CSAFPID-1497083", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:jt_open:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "mendix_encryption", "product": { "name": "mendix_encryption", "product_id": "CSAFPID-1497113", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:mendix_encryption:v10.0.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "plm_xml_sdk", "product": { "name": "plm_xml_sdk", "product_id": "CSAFPID-1497084", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:plm_xml_sdk:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ps_iges_parasolid_translator_component", "product": { "name": "ps_iges_parasolid_translator_component", "product_id": "CSAFPID-1464909", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ps_iges_parasolid_translator_component:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1496944", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497438", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497459", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497481", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.3:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497482", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.4:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497428", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.5:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497379", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.6:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497388", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.7:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1498045", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.8:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800", "product": { "name": "ruggedcom_i800", "product_id": "CSAFPID-1497498", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800:4.3.9:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800nc", "product": { "name": "ruggedcom_i800nc", "product_id": "CSAFPID-1496945", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800nc:0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom_i800nc", "product": { "name": "ruggedcom_i800nc", "product_id": "CSAFPID-1497536", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom_i800nc:4.3.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1498050", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.0:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497507", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.1:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1498073", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.2:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497596", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.3:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497876", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.4:*:*:*:*:*:*:*" } } }, { "category": "product_name", "name": "ruggedcom", "product": { "name": "ruggedcom", "product_id": "CSAFPID-1497817", "product_identification_helper": { "cpe": "cpe:2.3:a:siemens:ruggedcom:4.3.5:*:*:*:*:*:*:*" } } } ], "category": "vendor", "name": "siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-32260", "cwe": { "id": "CWE-286", "name": "Incorrect User Management" }, "notes": [ { "category": "other", "text": "Incorrect User Management", "title": "CWE-286" } ], "references": [ { "category": "self", "summary": "CVE-2022-32260", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2022/CVE-2022-32260.json" } ], "title": "CVE-2022-32260" }, { "cve": "CVE-2023-7066", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2023-7066", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-7066.json" } ], "title": "CVE-2023-7066" }, { "cve": "CVE-2023-27321", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" }, { "category": "other", "text": "NULL Pointer Dereference", "title": "CWE-476" }, { "category": "other", "text": "Improperly Controlled Sequential Memory Allocation", "title": "CWE-1325" } ], "references": [ { "category": "self", "summary": "CVE-2023-27321", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-27321.json" } ], "title": "CVE-2023-27321" }, { "cve": "CVE-2023-32735", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "other", "text": "Deserialization of Untrusted Data", "title": "CWE-502" } ], "references": [ { "category": "self", "summary": "CVE-2023-32735", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-32735.json" } ], "title": "CVE-2023-32735" }, { "cve": "CVE-2023-32737", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "other", "text": "Deserialization of Untrusted Data", "title": "CWE-502" } ], "references": [ { "category": "self", "summary": "CVE-2023-32737", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-32737.json" } ], "title": "CVE-2023-32737" }, { "cve": "CVE-2023-46720", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "references": [ { "category": "self", "summary": "CVE-2023-46720", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-46720.json" } ], "title": "CVE-2023-46720" }, { "cve": "CVE-2023-48795", "cwe": { "id": "CWE-222", "name": "Truncation of Security-relevant Information" }, "notes": [ { "category": "other", "text": "Truncation of Security-relevant Information", "title": "CWE-222" } ], "references": [ { "category": "self", "summary": "CVE-2023-48795", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-48795.json" } ], "title": "CVE-2023-48795" }, { "cve": "CVE-2023-52237", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "other", "text": "Exposure of Sensitive Information to an Unauthorized Actor", "title": "CWE-200" } ], "product_status": { "known_affected": [ "CSAFPID-1496944", "CSAFPID-1496945" ] }, "references": [ { "category": "self", "summary": "CVE-2023-52237", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52237.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-1496944", "CSAFPID-1496945" ] } ], "title": "CVE-2023-52237" }, { "cve": "CVE-2023-52238", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "other", "text": "Exposure of Sensitive Information to an Unauthorized Actor", "title": "CWE-200" } ], "references": [ { "category": "self", "summary": "CVE-2023-52238", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52238.json" } ], "title": "CVE-2023-52238" }, { "cve": "CVE-2023-52891", "cwe": { "id": "CWE-1325", "name": "Improperly Controlled Sequential Memory Allocation" }, "notes": [ { "category": "other", "text": "Improperly Controlled Sequential Memory Allocation", "title": "CWE-1325" } ], "references": [ { "category": "self", "summary": "CVE-2023-52891", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52891.json" } ], "title": "CVE-2023-52891" }, { "cve": "CVE-2024-21754", "cwe": { "id": "CWE-916", "name": "Use of Password Hash With Insufficient Computational Effort" }, "notes": [ { "category": "other", "text": "Use of Password Hash With Insufficient Computational Effort", "title": "CWE-916" } ], "references": [ { "category": "self", "summary": "CVE-2024-21754", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-21754.json" } ], "title": "CVE-2024-21754" }, { "cve": "CVE-2024-23111", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "title": "CWE-79" } ], "references": [ { "category": "self", "summary": "CVE-2024-23111", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-23111.json" } ], "title": "CVE-2024-23111" }, { "cve": "CVE-2024-26010", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "references": [ { "category": "self", "summary": "CVE-2024-26010", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-26010.json" } ], "title": "CVE-2024-26010" }, { "cve": "CVE-2024-30321", "cwe": { "id": "CWE-359", "name": "Exposure of Private Personal Information to an Unauthorized Actor" }, "notes": [ { "category": "other", "text": "Exposure of Private Personal Information to an Unauthorized Actor", "title": "CWE-359" } ], "references": [ { "category": "self", "summary": "CVE-2024-30321", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-30321.json" } ], "title": "CVE-2024-30321" }, { "cve": "CVE-2024-32055", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32055", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32055.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32055" }, { "cve": "CVE-2024-32056", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "other", "text": "Out-of-bounds Write", "title": "CWE-787" } ], "references": [ { "category": "self", "summary": "CVE-2024-32056", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32056.json" } ], "title": "CVE-2024-32056" }, { "cve": "CVE-2024-32057", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "other", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32057", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32057.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32057" }, { "cve": "CVE-2024-32058", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "other", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32058", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32058.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32058" }, { "cve": "CVE-2024-32059", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32059", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32059.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32059" }, { "cve": "CVE-2024-32060", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32060", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32060.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32060" }, { "cve": "CVE-2024-32061", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32061", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32061.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32061" }, { "cve": "CVE-2024-32062", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "other", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32062", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32062.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32062" }, { "cve": "CVE-2024-32063", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "other", "text": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)", "title": "CWE-843" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32063", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32063.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32063" }, { "cve": "CVE-2024-32064", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32064", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32064.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32064" }, { "cve": "CVE-2024-32065", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32065", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32065.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32065" }, { "cve": "CVE-2024-32066", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "product_status": { "known_affected": [ "CSAFPID-1464909" ] }, "references": [ { "category": "self", "summary": "CVE-2024-32066", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32066.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1464909" ] } ], "title": "CVE-2024-32066" }, { "cve": "CVE-2024-33577", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "references": [ { "category": "self", "summary": "CVE-2024-33577", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-33577.json" } ], "title": "CVE-2024-33577" }, { "cve": "CVE-2024-33653", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-33653", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-33653.json" } ], "title": "CVE-2024-33653" }, { "cve": "CVE-2024-33654", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-33654", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-33654.json" } ], "title": "CVE-2024-33654" }, { "cve": "CVE-2024-37996", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "other", "text": "NULL Pointer Dereference", "title": "CWE-476" } ], "product_status": { "known_affected": [ "CSAFPID-1497083", "CSAFPID-1497084" ] }, "references": [ { "category": "self", "summary": "CVE-2024-37996", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-37996.json" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-1497083", "CSAFPID-1497084" ] } ], "title": "CVE-2024-37996" }, { "cve": "CVE-2024-37997", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "other", "text": "Stack-based Buffer Overflow", "title": "CWE-121" } ], "product_status": { "known_affected": [ "CSAFPID-1497083", "CSAFPID-1497084" ] }, "references": [ { "category": "self", "summary": "CVE-2024-37997", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-37997.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-1497083", "CSAFPID-1497084" ] } ], "title": "CVE-2024-37997" }, { "cve": "CVE-2024-38278", "cwe": { "id": "CWE-266", "name": "Incorrect Privilege Assignment" }, "notes": [ { "category": "other", "text": "Incorrect Privilege Assignment", "title": "CWE-266" } ], "references": [ { "category": "self", "summary": "CVE-2024-38278", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38278.json" } ], "title": "CVE-2024-38278" }, { "cve": "CVE-2024-38867", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "other", "text": "Inadequate Encryption Strength", "title": "CWE-326" } ], "references": [ { "category": "self", "summary": "CVE-2024-38867", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-38867.json" } ], "title": "CVE-2024-38867" }, { "cve": "CVE-2024-39567", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39567", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39567.json" } ], "title": "CVE-2024-39567" }, { "cve": "CVE-2024-39568", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39568", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39568.json" } ], "title": "CVE-2024-39568" }, { "cve": "CVE-2024-39569", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39569", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39569.json" } ], "title": "CVE-2024-39569" }, { "cve": "CVE-2024-39570", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39570", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39570.json" } ], "title": "CVE-2024-39570" }, { "cve": "CVE-2024-39571", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "other", "text": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "title": "CWE-77" } ], "references": [ { "category": "self", "summary": "CVE-2024-39571", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39571.json" } ], "title": "CVE-2024-39571" }, { "cve": "CVE-2024-39675", "cwe": { "id": "CWE-497", "name": "Exposure of Sensitive System Information to an Unauthorized Control Sphere" }, "notes": [ { "category": "other", "text": "Exposure of Sensitive System Information to an Unauthorized Control Sphere", "title": "CWE-497" } ], "references": [ { "category": "self", "summary": "CVE-2024-39675", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39675.json" } ], "title": "CVE-2024-39675" }, { "cve": "CVE-2024-39865", "cwe": { "id": "CWE-434", "name": "Unrestricted Upload of File with Dangerous Type" }, "notes": [ { "category": "other", "text": "Unrestricted Upload of File with Dangerous Type", "title": "CWE-434" } ], "references": [ { "category": "self", "summary": "CVE-2024-39865", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39865.json" } ], "title": "CVE-2024-39865" }, { "cve": "CVE-2024-39866", "cwe": { "id": "CWE-267", "name": "Privilege Defined With Unsafe Actions" }, "notes": [ { "category": "other", "text": "Privilege Defined With Unsafe Actions", "title": "CWE-267" } ], "references": [ { "category": "self", "summary": "CVE-2024-39866", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39866.json" } ], "title": "CVE-2024-39866" }, { "cve": "CVE-2024-39867", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "other", "text": "Direct Request (\u0027Forced Browsing\u0027)", "title": "CWE-425" } ], "references": [ { "category": "self", "summary": "CVE-2024-39867", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39867.json" } ], "title": "CVE-2024-39867" }, { "cve": "CVE-2024-39868", "cwe": { "id": "CWE-425", "name": "Direct Request (\u0027Forced Browsing\u0027)" }, "notes": [ { "category": "other", "text": "Direct Request (\u0027Forced Browsing\u0027)", "title": "CWE-425" } ], "references": [ { "category": "self", "summary": "CVE-2024-39868", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39868.json" } ], "title": "CVE-2024-39868" }, { "cve": "CVE-2024-39869", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "other", "text": "Improper Check for Unusual or Exceptional Conditions", "title": "CWE-754" } ], "references": [ { "category": "self", "summary": "CVE-2024-39869", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39869.json" } ], "title": "CVE-2024-39869" }, { "cve": "CVE-2024-39870", "cwe": { "id": "CWE-602", "name": "Client-Side Enforcement of Server-Side Security" }, "notes": [ { "category": "other", "text": "Client-Side Enforcement of Server-Side Security", "title": "CWE-602" } ], "references": [ { "category": "self", "summary": "CVE-2024-39870", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39870.json" } ], "title": "CVE-2024-39870" }, { "cve": "CVE-2024-39871", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "other", "text": "Incorrect Authorization", "title": "CWE-863" } ], "references": [ { "category": "self", "summary": "CVE-2024-39871", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39871.json" } ], "title": "CVE-2024-39871" }, { "cve": "CVE-2024-39872", "cwe": { "id": "CWE-378", "name": "Creation of Temporary File With Insecure Permissions" }, "notes": [ { "category": "other", "text": "Creation of Temporary File With Insecure Permissions", "title": "CWE-378" } ], "references": [ { "category": "self", "summary": "CVE-2024-39872", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39872.json" } ], "title": "CVE-2024-39872" }, { "cve": "CVE-2024-39873", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "other", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" } ], "references": [ { "category": "self", "summary": "CVE-2024-39873", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39873.json" } ], "title": "CVE-2024-39873" }, { "cve": "CVE-2024-39874", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "other", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" } ], "references": [ { "category": "self", "summary": "CVE-2024-39874", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39874.json" } ], "title": "CVE-2024-39874" }, { "cve": "CVE-2024-39875", "cwe": { "id": "CWE-732", "name": "Incorrect Permission Assignment for Critical Resource" }, "notes": [ { "category": "other", "text": "Incorrect Permission Assignment for Critical Resource", "title": "CWE-732" } ], "references": [ { "category": "self", "summary": "CVE-2024-39875", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39875.json" } ], "title": "CVE-2024-39875" }, { "cve": "CVE-2024-39876", "cwe": { "id": "CWE-770", "name": "Allocation of Resources Without Limits or Throttling" }, "notes": [ { "category": "other", "text": "Allocation of Resources Without Limits or Throttling", "title": "CWE-770" } ], "references": [ { "category": "self", "summary": "CVE-2024-39876", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39876.json" } ], "title": "CVE-2024-39876" }, { "cve": "CVE-2024-39888", "cwe": { "id": "CWE-547", "name": "Use of Hard-coded, Security-relevant Constants" }, "notes": [ { "category": "other", "text": "Use of Hard-coded, Security-relevant Constants", "title": "CWE-547" } ], "product_status": { "known_affected": [ "CSAFPID-1497113" ] }, "references": [ { "category": "self", "summary": "CVE-2024-39888", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39888.json" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "products": [ "CSAFPID-1497113" ] } ], "title": "CVE-2024-39888" }, { "cve": "CVE-2024-3596", "cwe": { "id": "CWE-924", "name": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel" }, "notes": [ { "category": "other", "text": "Improper Enforcement of Message Integrity During Transmission in a Communication Channel", "title": "CWE-924" }, { "category": "other", "text": "Use of Weak Hash", "title": "CWE-328" } ], "references": [ { "category": "self", "summary": "CVE-2024-3596", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-3596.json" } ], "title": "CVE-2024-3596" } ] }
icsa-24-193-06
Vulnerability from csaf_cisa
Published
2024-07-09 00:00
Modified
2024-07-09 00:00
Summary
Siemens RUGGEDCOM
Notes
Summary
Multiple vulnerabilities affect the RUGGEDCOM Operating System (ROS). The common denominator to all vulnerabilities is the leak of confidential information.
Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "names": [ "Stephen Craven" ], "summary": "reporting these vulnerabilities to Siemens." }, { "names": [ "Thomas Riedmaier" ], "organization": "Siemens Energy", "summary": "reporting these vulnerabilities to Siemens." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Multiple vulnerabilities affect the RUGGEDCOM Operating System (ROS). The common denominator to all vulnerabilities is the leak of confidential information.\n\nSiemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-170375: Multiple Vulnerabilities in RUGGEDCOM ROS before V5.9 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-170375.json" }, { "category": "self", "summary": "SSA-170375: Multiple Vulnerabilities in RUGGEDCOM ROS before V5.9 - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-170375.html" }, { "category": "self", "summary": "SSA-170375: Multiple Vulnerabilities in RUGGEDCOM ROS before V5.9 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170375.pdf" }, { "category": "self", "summary": "SSA-170375: Multiple Vulnerabilities in RUGGEDCOM ROS before V5.9 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-170375.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-193-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-193-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-193-06 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens RUGGEDCOM", "tracking": { "current_release_date": "2024-07-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-193-06", "initial_release_date": "2024-07-09T00:00:00.000000Z", "revision_history": [ { "date": "2024-07-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i800", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "RUGGEDCOM i800" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i800NC", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "RUGGEDCOM i800NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i801", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "RUGGEDCOM i801" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i801NC", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "RUGGEDCOM i801NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i802", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "RUGGEDCOM i802" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i802NC", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "RUGGEDCOM i802NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i803", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "RUGGEDCOM i803" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM i803NC", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "RUGGEDCOM i803NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M969", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "RUGGEDCOM M969" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M969NC", "product_id": "CSAFPID-0010" } } ], "category": "product_name", "name": "RUGGEDCOM M969NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M2100", "product_id": "CSAFPID-0011" } } ], "category": "product_name", "name": "RUGGEDCOM M2100" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M2100NC", "product_id": "CSAFPID-0012" } } ], "category": "product_name", "name": "RUGGEDCOM M2100NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M2200", "product_id": "CSAFPID-0013" } } ], "category": "product_name", "name": "RUGGEDCOM M2200" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM M2200NC", "product_id": "CSAFPID-0014" } } ], "category": "product_name", "name": "RUGGEDCOM M2200NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RMC30", "product_id": "CSAFPID-0015" } } ], "category": "product_name", "name": "RUGGEDCOM RMC30" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RMC30NC", "product_id": "CSAFPID-0016" } } ], "category": "product_name", "name": "RUGGEDCOM RMC30NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RMC8388 V4.X", "product_id": "CSAFPID-0017" } } ], "category": "product_name", "name": "RUGGEDCOM RMC8388 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RMC8388 V5.X", "product_id": "CSAFPID-0018" } } ], "category": "product_name", "name": "RUGGEDCOM RMC8388 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RMC8388NC V4.X", "product_id": "CSAFPID-0019" } } ], "category": "product_name", "name": "RUGGEDCOM RMC8388NC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RMC8388NC V5.X", "product_id": "CSAFPID-0020" } } ], "category": "product_name", "name": "RUGGEDCOM RMC8388NC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RP110", "product_id": "CSAFPID-0021" } } ], "category": "product_name", "name": "RUGGEDCOM RP110" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RP110NC", "product_id": "CSAFPID-0022" } } ], "category": "product_name", "name": "RUGGEDCOM RP110NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS400", "product_id": "CSAFPID-0023" } } ], "category": "product_name", "name": "RUGGEDCOM RS400" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS400NC", "product_id": "CSAFPID-0024" } } ], "category": "product_name", "name": "RUGGEDCOM RS400NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS401", "product_id": "CSAFPID-0025" } } ], "category": "product_name", "name": "RUGGEDCOM RS401" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS401NC", "product_id": "CSAFPID-0026" } } ], "category": "product_name", "name": "RUGGEDCOM RS401NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416", "product_id": "CSAFPID-0027" } } ], "category": "product_name", "name": "RUGGEDCOM RS416" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416NC", "product_id": "CSAFPID-0028" } } ], "category": "product_name", "name": "RUGGEDCOM RS416NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416NCv2 V4.X", "product_id": "CSAFPID-0029" } } ], "category": "product_name", "name": "RUGGEDCOM RS416NCv2 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS416NCv2 V5.X", "product_id": "CSAFPID-0030" } } ], "category": "product_name", "name": "RUGGEDCOM RS416NCv2 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416P", "product_id": "CSAFPID-0031" } } ], "category": "product_name", "name": "RUGGEDCOM RS416P" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416PNC", "product_id": "CSAFPID-0032" } } ], "category": "product_name", "name": "RUGGEDCOM RS416PNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416PNCv2 V4.X", "product_id": "CSAFPID-0033" } } ], "category": "product_name", "name": "RUGGEDCOM RS416PNCv2 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS416PNCv2 V5.X", "product_id": "CSAFPID-0034" } } ], "category": "product_name", "name": "RUGGEDCOM RS416PNCv2 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416Pv2 V4.X", "product_id": "CSAFPID-0035" } } ], "category": "product_name", "name": "RUGGEDCOM RS416Pv2 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS416Pv2 V5.X", "product_id": "CSAFPID-0036" } } ], "category": "product_name", "name": "RUGGEDCOM RS416Pv2 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS416v2 V4.X", "product_id": "CSAFPID-0037" } } ], "category": "product_name", "name": "RUGGEDCOM RS416v2 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS416v2 V5.X", "product_id": "CSAFPID-0038" } } ], "category": "product_name", "name": "RUGGEDCOM RS416v2 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900", "product_id": "CSAFPID-0039" } } ], "category": "product_name", "name": "RUGGEDCOM RS900" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900 (32M) V4.X", "product_id": "CSAFPID-0040" } } ], "category": "product_name", "name": "RUGGEDCOM RS900 (32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS900 (32M) V5.X", "product_id": "CSAFPID-0041" } } ], "category": "product_name", "name": "RUGGEDCOM RS900 (32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900G", "product_id": "CSAFPID-0042" } } ], "category": "product_name", "name": "RUGGEDCOM RS900G" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900G (32M) V4.X", "product_id": "CSAFPID-0043" } } ], "category": "product_name", "name": "RUGGEDCOM RS900G (32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS900G (32M) V5.X", "product_id": "CSAFPID-0044" } } ], "category": "product_name", "name": "RUGGEDCOM RS900G (32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900GNC", "product_id": "CSAFPID-0045" } } ], "category": "product_name", "name": "RUGGEDCOM RS900GNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900GNC(32M) V4.X", "product_id": "CSAFPID-0046" } } ], "category": "product_name", "name": "RUGGEDCOM RS900GNC(32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS900GNC(32M) V5.X", "product_id": "CSAFPID-0047" } } ], "category": "product_name", "name": "RUGGEDCOM RS900GNC(32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900GP", "product_id": "CSAFPID-0048" } } ], "category": "product_name", "name": "RUGGEDCOM RS900GP" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900GPNC", "product_id": "CSAFPID-0049" } } ], "category": "product_name", "name": "RUGGEDCOM RS900GPNC" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS900L", "product_id": "CSAFPID-0050" } } ], "category": "product_name", "name": "RUGGEDCOM RS900L" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS900LNC", "product_id": "CSAFPID-0051" } } ], "category": "product_name", "name": "RUGGEDCOM RS900LNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900M-GETS-C01", "product_id": "CSAFPID-0052" } } ], "category": "product_name", "name": "RUGGEDCOM RS900M-GETS-C01" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900M-GETS-XX", "product_id": "CSAFPID-0053" } } ], "category": "product_name", "name": "RUGGEDCOM RS900M-GETS-XX" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900M-STND-C01", "product_id": "CSAFPID-0054" } } ], "category": "product_name", "name": "RUGGEDCOM RS900M-STND-C01" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900M-STND-XX", "product_id": "CSAFPID-0055" } } ], "category": "product_name", "name": "RUGGEDCOM RS900M-STND-XX" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900MNC-GETS-C01", "product_id": "CSAFPID-0056" } } ], "category": "product_name", "name": "RUGGEDCOM RS900MNC-GETS-C01" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900MNC-GETS-XX", "product_id": "CSAFPID-0057" } } ], "category": "product_name", "name": "RUGGEDCOM RS900MNC-GETS-XX" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900MNC-STND-XX", "product_id": "CSAFPID-0058" } } ], "category": "product_name", "name": "RUGGEDCOM RS900MNC-STND-XX" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900MNC-STND-XX-C01", "product_id": "CSAFPID-0059" } } ], "category": "product_name", "name": "RUGGEDCOM RS900MNC-STND-XX-C01" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900NC", "product_id": "CSAFPID-0060" } } ], "category": "product_name", "name": "RUGGEDCOM RS900NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900NC(32M) V4.X", "product_id": "CSAFPID-0061" } } ], "category": "product_name", "name": "RUGGEDCOM RS900NC(32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RS900NC(32M) V5.X", "product_id": "CSAFPID-0062" } } ], "category": "product_name", "name": "RUGGEDCOM RS900NC(32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS900W", "product_id": "CSAFPID-0063" } } ], "category": "product_name", "name": "RUGGEDCOM RS900W" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS910", "product_id": "CSAFPID-0064" } } ], "category": "product_name", "name": "RUGGEDCOM RS910" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS910L", "product_id": "CSAFPID-0065" } } ], "category": "product_name", "name": "RUGGEDCOM RS910L" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS910LNC", "product_id": "CSAFPID-0066" } } ], "category": "product_name", "name": "RUGGEDCOM RS910LNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS910NC", "product_id": "CSAFPID-0067" } } ], "category": "product_name", "name": "RUGGEDCOM RS910NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS910W", "product_id": "CSAFPID-0068" } } ], "category": "product_name", "name": "RUGGEDCOM RS910W" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS920L", "product_id": "CSAFPID-0069" } } ], "category": "product_name", "name": "RUGGEDCOM RS920L" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS920LNC", "product_id": "CSAFPID-0070" } } ], "category": "product_name", "name": "RUGGEDCOM RS920LNC" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS920W", "product_id": "CSAFPID-0071" } } ], "category": "product_name", "name": "RUGGEDCOM RS920W" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS930L", "product_id": "CSAFPID-0072" } } ], "category": "product_name", "name": "RUGGEDCOM RS930L" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS930LNC", "product_id": "CSAFPID-0073" } } ], "category": "product_name", "name": "RUGGEDCOM RS930LNC" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS930W", "product_id": "CSAFPID-0074" } } ], "category": "product_name", "name": "RUGGEDCOM RS930W" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS940G", "product_id": "CSAFPID-0075" } } ], "category": "product_name", "name": "RUGGEDCOM RS940G" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS940GNC", "product_id": "CSAFPID-0076" } } ], "category": "product_name", "name": "RUGGEDCOM RS940GNC" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS969", "product_id": "CSAFPID-0077" } } ], "category": "product_name", "name": "RUGGEDCOM RS969" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "RUGGEDCOM RS969NC", "product_id": "CSAFPID-0078" } } ], "category": "product_name", "name": "RUGGEDCOM RS969NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600", "product_id": "CSAFPID-0079" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600F", "product_id": "CSAFPID-0080" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600F" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600FNC", "product_id": "CSAFPID-0081" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600FNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600NC", "product_id": "CSAFPID-0082" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600T", "product_id": "CSAFPID-0083" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600T" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS1600TNC", "product_id": "CSAFPID-0084" } } ], "category": "product_name", "name": "RUGGEDCOM RS1600TNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000", "product_id": "CSAFPID-0085" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000A", "product_id": "CSAFPID-0086" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000A" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000ANC", "product_id": "CSAFPID-0087" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000ANC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000H", "product_id": "CSAFPID-0088" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000H" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000HNC", "product_id": "CSAFPID-0089" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000HNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000NC", "product_id": "CSAFPID-0090" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000T", "product_id": "CSAFPID-0091" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000T" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RS8000TNC", "product_id": "CSAFPID-0092" } } ], "category": "product_name", "name": "RUGGEDCOM RS8000TNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG907R", "product_id": "CSAFPID-0093" } } ], "category": "product_name", "name": "RUGGEDCOM RSG907R" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG908C", "product_id": "CSAFPID-0094" } } ], "category": "product_name", "name": "RUGGEDCOM RSG908C" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG909R", "product_id": "CSAFPID-0095" } } ], "category": "product_name", "name": "RUGGEDCOM RSG909R" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG910C", "product_id": "CSAFPID-0096" } } ], "category": "product_name", "name": "RUGGEDCOM RSG910C" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG920P V4.X", "product_id": "CSAFPID-0097" } } ], "category": "product_name", "name": "RUGGEDCOM RSG920P V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG920P V5.X", "product_id": "CSAFPID-0098" } } ], "category": "product_name", "name": "RUGGEDCOM RSG920P V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG920PNC V4.X", "product_id": "CSAFPID-0099" } } ], "category": "product_name", "name": "RUGGEDCOM RSG920PNC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG920PNC V5.X", "product_id": "CSAFPID-0100" } } ], "category": "product_name", "name": "RUGGEDCOM RSG920PNC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100", "product_id": "CSAFPID-0101" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100 (32M) V4.X", "product_id": "CSAFPID-0102" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100 (32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2100 (32M) V5.X", "product_id": "CSAFPID-0103" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100 (32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100NC", "product_id": "CSAFPID-0104" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100NC(32M) V4.X", "product_id": "CSAFPID-0105" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100NC(32M) V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2100NC(32M) V5.X", "product_id": "CSAFPID-0106" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100NC(32M) V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100P", "product_id": "CSAFPID-0107" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100P" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2100PNC", "product_id": "CSAFPID-0108" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2100PNC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2200", "product_id": "CSAFPID-0109" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2200" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2200NC", "product_id": "CSAFPID-0110" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2200NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2288 V4.X", "product_id": "CSAFPID-0111" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2288 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2288 V5.X", "product_id": "CSAFPID-0112" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2288 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2288NC V4.X", "product_id": "CSAFPID-0113" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2288NC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2288NC V5.X", "product_id": "CSAFPID-0114" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2288NC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2300 V4.X", "product_id": "CSAFPID-0115" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2300 V5.X", "product_id": "CSAFPID-0116" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2300NC V4.X", "product_id": "CSAFPID-0117" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300NC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2300NC V5.X", "product_id": "CSAFPID-0118" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300NC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2300P V4.X", "product_id": "CSAFPID-0119" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300P V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2300P V5.X", "product_id": "CSAFPID-0120" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300P V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2300PNC V4.X", "product_id": "CSAFPID-0121" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300PNC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2300PNC V5.X", "product_id": "CSAFPID-0122" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2300PNC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2488 V4.X", "product_id": "CSAFPID-0123" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2488 V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2488 V5.X", "product_id": "CSAFPID-0124" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2488 V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV4.3.10", "product": { "name": "RUGGEDCOM RSG2488NC V4.X", "product_id": "CSAFPID-0125" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2488NC V4.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSG2488NC V5.X", "product_id": "CSAFPID-0126" } } ], "category": "product_name", "name": "RUGGEDCOM RSG2488NC V5.X" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSL910", "product_id": "CSAFPID-0127" } } ], "category": "product_name", "name": "RUGGEDCOM RSL910" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RSL910NC", "product_id": "CSAFPID-0128" } } ], "category": "product_name", "name": "RUGGEDCOM RSL910NC" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RST916C", "product_id": "CSAFPID-0129" } } ], "category": "product_name", "name": "RUGGEDCOM RST916C" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RST916P", "product_id": "CSAFPID-0130" } } ], "category": "product_name", "name": "RUGGEDCOM RST916P" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RST2228", "product_id": "CSAFPID-0131" } } ], "category": "product_name", "name": "RUGGEDCOM RST2228" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV5.9.0", "product": { "name": "RUGGEDCOM RST2228P", "product_id": "CSAFPID-0132" } } ], "category": "product_name", "name": "RUGGEDCOM RST2228P" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-52237", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "The web server of the affected devices allow a low privileged user to access hashes and password salts of all system\u0027s users, including admin users. An attacker could use the obtained information to brute force the passwords offline.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0079", "CSAFPID-0080", "CSAFPID-0081", "CSAFPID-0082", "CSAFPID-0083", "CSAFPID-0084", "CSAFPID-0023", "CSAFPID-0024", "CSAFPID-0025", "CSAFPID-0026", "CSAFPID-0027", "CSAFPID-0028", "CSAFPID-0029", "CSAFPID-0030", "CSAFPID-0031", "CSAFPID-0032", "CSAFPID-0033", "CSAFPID-0034", "CSAFPID-0035", "CSAFPID-0036", "CSAFPID-0037", "CSAFPID-0038", "CSAFPID-0085", "CSAFPID-0086", "CSAFPID-0087", "CSAFPID-0088", "CSAFPID-0089", "CSAFPID-0090", "CSAFPID-0091", "CSAFPID-0092", "CSAFPID-0039", "CSAFPID-0040", "CSAFPID-0041", "CSAFPID-0042", "CSAFPID-0043", "CSAFPID-0044", "CSAFPID-0045", "CSAFPID-0046", "CSAFPID-0047", "CSAFPID-0048", "CSAFPID-0049", "CSAFPID-0050", "CSAFPID-0051", "CSAFPID-0052", "CSAFPID-0053", "CSAFPID-0054", "CSAFPID-0055", "CSAFPID-0056", "CSAFPID-0057", "CSAFPID-0058", "CSAFPID-0059", "CSAFPID-0060", "CSAFPID-0061", "CSAFPID-0062", "CSAFPID-0063", "CSAFPID-0064", "CSAFPID-0065", "CSAFPID-0066", "CSAFPID-0067", "CSAFPID-0068", "CSAFPID-0069", "CSAFPID-0070", "CSAFPID-0071", "CSAFPID-0072", "CSAFPID-0073", "CSAFPID-0074", "CSAFPID-0075", "CSAFPID-0076", "CSAFPID-0077", "CSAFPID-0078", "CSAFPID-0101", "CSAFPID-0102", "CSAFPID-0103", "CSAFPID-0104", "CSAFPID-0105", "CSAFPID-0106", "CSAFPID-0107", "CSAFPID-0108", "CSAFPID-0109", "CSAFPID-0110", "CSAFPID-0111", "CSAFPID-0112", "CSAFPID-0113", "CSAFPID-0114", "CSAFPID-0115", "CSAFPID-0116", "CSAFPID-0117", "CSAFPID-0118", "CSAFPID-0119", "CSAFPID-0120", "CSAFPID-0121", "CSAFPID-0122", "CSAFPID-0123", "CSAFPID-0124", "CSAFPID-0125", "CSAFPID-0126", "CSAFPID-0093", "CSAFPID-0094", "CSAFPID-0095", "CSAFPID-0096", "CSAFPID-0097", "CSAFPID-0098", "CSAFPID-0099", "CSAFPID-0100", "CSAFPID-0127", "CSAFPID-0128", "CSAFPID-0131", "CSAFPID-0132", "CSAFPID-0129", "CSAFPID-0130" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0050", "CSAFPID-0051", "CSAFPID-0065", "CSAFPID-0066", "CSAFPID-0069", "CSAFPID-0070", "CSAFPID-0071", "CSAFPID-0072", "CSAFPID-0073", "CSAFPID-0074", "CSAFPID-0077", "CSAFPID-0078" ] }, { "category": "vendor_fix", "details": "Update to V4.3.10 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0003", "CSAFPID-0005", "CSAFPID-0007", "CSAFPID-0011", "CSAFPID-0013", "CSAFPID-0009", "CSAFPID-0015", "CSAFPID-0017", "CSAFPID-0021", "CSAFPID-0079", "CSAFPID-0080", "CSAFPID-0083", "CSAFPID-0023", "CSAFPID-0025", "CSAFPID-0027", "CSAFPID-0035", "CSAFPID-0037", "CSAFPID-0085", "CSAFPID-0086", "CSAFPID-0088", "CSAFPID-0091", "CSAFPID-0039", "CSAFPID-0040", "CSAFPID-0042", "CSAFPID-0043", "CSAFPID-0048", "CSAFPID-0063", "CSAFPID-0064", "CSAFPID-0068", "CSAFPID-0075", "CSAFPID-0101", "CSAFPID-0102", "CSAFPID-0107", "CSAFPID-0109", "CSAFPID-0111", "CSAFPID-0115", "CSAFPID-0119", "CSAFPID-0123", "CSAFPID-0097" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972218/" }, { "category": "vendor_fix", "details": "Update to V4.3.10 or later version", "product_ids": [ "CSAFPID-0002", "CSAFPID-0004", "CSAFPID-0006", "CSAFPID-0008", "CSAFPID-0012", "CSAFPID-0014", "CSAFPID-0010", "CSAFPID-0016", "CSAFPID-0019", "CSAFPID-0022", "CSAFPID-0081", "CSAFPID-0082", "CSAFPID-0084", "CSAFPID-0024", "CSAFPID-0026", "CSAFPID-0028", "CSAFPID-0029", "CSAFPID-0031", "CSAFPID-0032", "CSAFPID-0033", "CSAFPID-0087", "CSAFPID-0089", "CSAFPID-0090", "CSAFPID-0092", "CSAFPID-0045", "CSAFPID-0046", "CSAFPID-0049", "CSAFPID-0052", "CSAFPID-0053", "CSAFPID-0054", "CSAFPID-0055", "CSAFPID-0056", "CSAFPID-0057", "CSAFPID-0058", "CSAFPID-0059", "CSAFPID-0060", "CSAFPID-0061", "CSAFPID-0067", "CSAFPID-0076", "CSAFPID-0104", "CSAFPID-0105", "CSAFPID-0108", "CSAFPID-0110", "CSAFPID-0113", "CSAFPID-0117", "CSAFPID-0121", "CSAFPID-0125", "CSAFPID-0099" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972218/" }, { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "CSAFPID-0018", "CSAFPID-0036", "CSAFPID-0038", "CSAFPID-0041", "CSAFPID-0044", "CSAFPID-0103", "CSAFPID-0112", "CSAFPID-0116", "CSAFPID-0120", "CSAFPID-0124", "CSAFPID-0093", "CSAFPID-0094", "CSAFPID-0095", "CSAFPID-0096", "CSAFPID-0098", "CSAFPID-0127", "CSAFPID-0131", "CSAFPID-0132", "CSAFPID-0129", "CSAFPID-0130" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "CSAFPID-0020", "CSAFPID-0030", "CSAFPID-0034", "CSAFPID-0047", "CSAFPID-0062", "CSAFPID-0106", "CSAFPID-0114", "CSAFPID-0118", "CSAFPID-0122", "CSAFPID-0126", "CSAFPID-0100", "CSAFPID-0128" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "workaround", "details": "For CVE-2023-52237, CVE-2023-52238: Disable the webserver if not required on the affected systems. Restrict the access to Port 80/tcp and 443/tcp to trusted IP address only", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0079", "CSAFPID-0080", "CSAFPID-0081", "CSAFPID-0082", "CSAFPID-0083", "CSAFPID-0084", "CSAFPID-0023", "CSAFPID-0024", "CSAFPID-0025", "CSAFPID-0026", "CSAFPID-0027", "CSAFPID-0028", "CSAFPID-0029", "CSAFPID-0030", "CSAFPID-0031", "CSAFPID-0032", "CSAFPID-0033", "CSAFPID-0034", "CSAFPID-0035", "CSAFPID-0036", "CSAFPID-0037", "CSAFPID-0038", "CSAFPID-0085", "CSAFPID-0086", "CSAFPID-0087", "CSAFPID-0088", "CSAFPID-0089", "CSAFPID-0090", "CSAFPID-0091", "CSAFPID-0092", "CSAFPID-0039", "CSAFPID-0040", "CSAFPID-0041", "CSAFPID-0042", "CSAFPID-0043", "CSAFPID-0044", "CSAFPID-0045", "CSAFPID-0046", "CSAFPID-0047", "CSAFPID-0048", "CSAFPID-0049", "CSAFPID-0050", "CSAFPID-0051", "CSAFPID-0052", "CSAFPID-0053", "CSAFPID-0054", "CSAFPID-0055", "CSAFPID-0056", "CSAFPID-0057", "CSAFPID-0058", "CSAFPID-0059", "CSAFPID-0060", "CSAFPID-0061", "CSAFPID-0062", "CSAFPID-0063", "CSAFPID-0064", "CSAFPID-0065", "CSAFPID-0066", "CSAFPID-0067", "CSAFPID-0068", "CSAFPID-0069", "CSAFPID-0070", "CSAFPID-0071", "CSAFPID-0072", "CSAFPID-0073", "CSAFPID-0074", "CSAFPID-0075", "CSAFPID-0076", "CSAFPID-0077", "CSAFPID-0078", "CSAFPID-0101", "CSAFPID-0102", "CSAFPID-0103", "CSAFPID-0104", "CSAFPID-0105", "CSAFPID-0106", "CSAFPID-0107", "CSAFPID-0108", "CSAFPID-0109", "CSAFPID-0110", "CSAFPID-0111", "CSAFPID-0112", "CSAFPID-0113", "CSAFPID-0114", "CSAFPID-0115", "CSAFPID-0116", "CSAFPID-0117", "CSAFPID-0118", "CSAFPID-0119", "CSAFPID-0120", "CSAFPID-0121", "CSAFPID-0122", "CSAFPID-0123", "CSAFPID-0124", "CSAFPID-0125", "CSAFPID-0126", "CSAFPID-0093", "CSAFPID-0094", "CSAFPID-0095", "CSAFPID-0096", "CSAFPID-0097", "CSAFPID-0098", "CSAFPID-0099", "CSAFPID-0100", "CSAFPID-0127", "CSAFPID-0128", "CSAFPID-0131", "CSAFPID-0132", "CSAFPID-0129", "CSAFPID-0130" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0011", "CSAFPID-0012", "CSAFPID-0013", "CSAFPID-0014", "CSAFPID-0009", "CSAFPID-0010", "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0017", "CSAFPID-0018", "CSAFPID-0019", "CSAFPID-0020", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0079", "CSAFPID-0080", "CSAFPID-0081", "CSAFPID-0082", "CSAFPID-0083", "CSAFPID-0084", "CSAFPID-0023", "CSAFPID-0024", "CSAFPID-0025", "CSAFPID-0026", "CSAFPID-0027", "CSAFPID-0028", "CSAFPID-0029", "CSAFPID-0030", "CSAFPID-0031", "CSAFPID-0032", "CSAFPID-0033", "CSAFPID-0034", "CSAFPID-0035", "CSAFPID-0036", "CSAFPID-0037", "CSAFPID-0038", "CSAFPID-0085", "CSAFPID-0086", "CSAFPID-0087", "CSAFPID-0088", "CSAFPID-0089", "CSAFPID-0090", "CSAFPID-0091", "CSAFPID-0092", "CSAFPID-0039", "CSAFPID-0040", "CSAFPID-0041", "CSAFPID-0042", "CSAFPID-0043", "CSAFPID-0044", "CSAFPID-0045", "CSAFPID-0046", "CSAFPID-0047", "CSAFPID-0048", "CSAFPID-0049", "CSAFPID-0050", "CSAFPID-0051", "CSAFPID-0052", "CSAFPID-0053", "CSAFPID-0054", "CSAFPID-0055", "CSAFPID-0056", "CSAFPID-0057", "CSAFPID-0058", "CSAFPID-0059", "CSAFPID-0060", "CSAFPID-0061", "CSAFPID-0062", "CSAFPID-0063", "CSAFPID-0064", "CSAFPID-0065", "CSAFPID-0066", "CSAFPID-0067", "CSAFPID-0068", "CSAFPID-0069", "CSAFPID-0070", "CSAFPID-0071", "CSAFPID-0072", "CSAFPID-0073", "CSAFPID-0074", "CSAFPID-0075", "CSAFPID-0076", "CSAFPID-0077", "CSAFPID-0078", "CSAFPID-0101", "CSAFPID-0102", "CSAFPID-0103", "CSAFPID-0104", "CSAFPID-0105", "CSAFPID-0106", "CSAFPID-0107", "CSAFPID-0108", "CSAFPID-0109", "CSAFPID-0110", "CSAFPID-0111", "CSAFPID-0112", "CSAFPID-0113", "CSAFPID-0114", "CSAFPID-0115", "CSAFPID-0116", "CSAFPID-0117", "CSAFPID-0118", "CSAFPID-0119", "CSAFPID-0120", "CSAFPID-0121", "CSAFPID-0122", "CSAFPID-0123", "CSAFPID-0124", "CSAFPID-0125", "CSAFPID-0126", "CSAFPID-0093", "CSAFPID-0094", "CSAFPID-0095", "CSAFPID-0096", "CSAFPID-0097", "CSAFPID-0098", "CSAFPID-0099", "CSAFPID-0100", "CSAFPID-0127", "CSAFPID-0128", "CSAFPID-0131", "CSAFPID-0132", "CSAFPID-0129", "CSAFPID-0130" ] } ], "title": "CVE-2023-52237" }, { "cve": "CVE-2023-52238", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0131", "CSAFPID-0132" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "CSAFPID-0131", "CSAFPID-0132" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "workaround", "details": "For CVE-2023-52237, CVE-2023-52238: Disable the webserver if not required on the affected systems. Restrict the access to Port 80/tcp and 443/tcp to trusted IP address only", "product_ids": [ "CSAFPID-0131", "CSAFPID-0132" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0131", "CSAFPID-0132" ] } ], "title": "CVE-2023-52238" }, { "cve": "CVE-2024-38278", "cwe": { "id": "CWE-266", "name": "Incorrect Privilege Assignment" }, "notes": [ { "category": "summary", "text": "The affected products with IP forwarding enabled wrongly make available certain remote services in non-managed VLANs, even if these services are not intentionally activated. An attacker could leverage this vulnerability to create a remote shell to the affected system.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0018", "CSAFPID-0020", "CSAFPID-0030", "CSAFPID-0034", "CSAFPID-0036", "CSAFPID-0038", "CSAFPID-0041", "CSAFPID-0044", "CSAFPID-0047", "CSAFPID-0062", "CSAFPID-0103", "CSAFPID-0106", "CSAFPID-0112", "CSAFPID-0114", "CSAFPID-0116", "CSAFPID-0118", "CSAFPID-0120", "CSAFPID-0122", "CSAFPID-0124", "CSAFPID-0126", "CSAFPID-0093", "CSAFPID-0094", "CSAFPID-0095", "CSAFPID-0096", "CSAFPID-0098", "CSAFPID-0100", "CSAFPID-0127", "CSAFPID-0128", "CSAFPID-0131", "CSAFPID-0132", "CSAFPID-0129", "CSAFPID-0130" ] }, "remediations": [ { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "CSAFPID-0018", "CSAFPID-0036", "CSAFPID-0038", "CSAFPID-0041", "CSAFPID-0044", "CSAFPID-0103", "CSAFPID-0112", "CSAFPID-0116", "CSAFPID-0120", "CSAFPID-0124", "CSAFPID-0093", "CSAFPID-0094", "CSAFPID-0095", "CSAFPID-0096", "CSAFPID-0098", "CSAFPID-0127", "CSAFPID-0131", "CSAFPID-0132", "CSAFPID-0129", "CSAFPID-0130" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "CSAFPID-0020", "CSAFPID-0030", "CSAFPID-0034", "CSAFPID-0047", "CSAFPID-0062", "CSAFPID-0106", "CSAFPID-0114", "CSAFPID-0118", "CSAFPID-0122", "CSAFPID-0126", "CSAFPID-0100", "CSAFPID-0128" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "workaround", "details": "For CVE-2024-38278: Disable the IP Forwarding if not required on the affected system. Also note, the IP forwarding is disabled by default", "product_ids": [ "CSAFPID-0018", "CSAFPID-0020", "CSAFPID-0030", "CSAFPID-0034", "CSAFPID-0036", "CSAFPID-0038", "CSAFPID-0041", "CSAFPID-0044", "CSAFPID-0047", "CSAFPID-0062", "CSAFPID-0103", "CSAFPID-0106", "CSAFPID-0112", "CSAFPID-0114", "CSAFPID-0116", "CSAFPID-0118", "CSAFPID-0120", "CSAFPID-0122", "CSAFPID-0124", "CSAFPID-0126", "CSAFPID-0093", "CSAFPID-0094", "CSAFPID-0095", "CSAFPID-0096", "CSAFPID-0098", "CSAFPID-0100", "CSAFPID-0127", "CSAFPID-0128", "CSAFPID-0131", "CSAFPID-0132", "CSAFPID-0129", "CSAFPID-0130" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0018", "CSAFPID-0020", "CSAFPID-0030", "CSAFPID-0034", "CSAFPID-0036", "CSAFPID-0038", "CSAFPID-0041", "CSAFPID-0044", "CSAFPID-0047", "CSAFPID-0062", "CSAFPID-0103", "CSAFPID-0106", "CSAFPID-0112", "CSAFPID-0114", "CSAFPID-0116", "CSAFPID-0118", "CSAFPID-0120", "CSAFPID-0122", "CSAFPID-0124", "CSAFPID-0126", "CSAFPID-0093", "CSAFPID-0094", "CSAFPID-0095", "CSAFPID-0096", "CSAFPID-0098", "CSAFPID-0100", "CSAFPID-0127", "CSAFPID-0128", "CSAFPID-0131", "CSAFPID-0132", "CSAFPID-0129", "CSAFPID-0130" ] } ], "title": "CVE-2024-38278" }, { "cve": "CVE-2024-39675", "cwe": { "id": "CWE-497", "name": "Exposure of Sensitive System Information to an Unauthorized Control Sphere" }, "notes": [ { "category": "summary", "text": "In some configurations the affected products wrongly enable the Modbus service in non-managed VLANS. Only serial devices are affected by this vulnerability.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023", "CSAFPID-0024", "CSAFPID-0025", "CSAFPID-0026", "CSAFPID-0027", "CSAFPID-0028", "CSAFPID-0029", "CSAFPID-0030", "CSAFPID-0031", "CSAFPID-0032", "CSAFPID-0033", "CSAFPID-0034", "CSAFPID-0035", "CSAFPID-0036", "CSAFPID-0037", "CSAFPID-0038", "CSAFPID-0064", "CSAFPID-0065", "CSAFPID-0066", "CSAFPID-0067", "CSAFPID-0068", "CSAFPID-0069", "CSAFPID-0070", "CSAFPID-0071" ] }, "remediations": [ { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "CSAFPID-0065", "CSAFPID-0066", "CSAFPID-0069", "CSAFPID-0070", "CSAFPID-0071" ] }, { "category": "vendor_fix", "details": "Update to V4.3.10 or later version", "product_ids": [ "CSAFPID-0015", "CSAFPID-0021", "CSAFPID-0023", "CSAFPID-0025", "CSAFPID-0027", "CSAFPID-0035", "CSAFPID-0037", "CSAFPID-0064", "CSAFPID-0068" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972218/" }, { "category": "vendor_fix", "details": "Update to V4.3.10 or later version", "product_ids": [ "CSAFPID-0016", "CSAFPID-0022", "CSAFPID-0024", "CSAFPID-0026", "CSAFPID-0028", "CSAFPID-0029", "CSAFPID-0031", "CSAFPID-0032", "CSAFPID-0033", "CSAFPID-0067" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972218/" }, { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "CSAFPID-0036", "CSAFPID-0038" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "vendor_fix", "details": "Update to V5.9.0 or later version", "product_ids": [ "CSAFPID-0030", "CSAFPID-0034" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109972217/" }, { "category": "workaround", "details": "For CVE-2024-39675: Disable the Modbus Server if not required on the affected system. Restrict the access to Port 502/tcp to trusted IP address only. Also note, Modbus is disabled by default", "product_ids": [ "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023", "CSAFPID-0024", "CSAFPID-0025", "CSAFPID-0026", "CSAFPID-0027", "CSAFPID-0028", "CSAFPID-0029", "CSAFPID-0030", "CSAFPID-0031", "CSAFPID-0032", "CSAFPID-0033", "CSAFPID-0034", "CSAFPID-0035", "CSAFPID-0036", "CSAFPID-0037", "CSAFPID-0038", "CSAFPID-0064", "CSAFPID-0065", "CSAFPID-0066", "CSAFPID-0067", "CSAFPID-0068", "CSAFPID-0069", "CSAFPID-0070", "CSAFPID-0071" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0015", "CSAFPID-0016", "CSAFPID-0021", "CSAFPID-0022", "CSAFPID-0023", "CSAFPID-0024", "CSAFPID-0025", "CSAFPID-0026", "CSAFPID-0027", "CSAFPID-0028", "CSAFPID-0029", "CSAFPID-0030", "CSAFPID-0031", "CSAFPID-0032", "CSAFPID-0033", "CSAFPID-0034", "CSAFPID-0035", "CSAFPID-0036", "CSAFPID-0037", "CSAFPID-0038", "CSAFPID-0064", "CSAFPID-0065", "CSAFPID-0066", "CSAFPID-0067", "CSAFPID-0068", "CSAFPID-0069", "CSAFPID-0070", "CSAFPID-0071" ] } ], "title": "CVE-2024-39675" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.