cve-2023-49130
Vulnerability from cvelistv5
Published
2024-01-09 10:00
Modified
2024-08-02 21:46
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Solid Edge SE2023 |
Version: All versions < V223.0 Update 10 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:46:29.185Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Solid Edge SE2023", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V223.0 Update 10" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-824", "description": "CWE-824: Access of Uninitialized Pointer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T10:00:04.164Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-49130", "datePublished": "2024-01-09T10:00:04.164Z", "dateReserved": "2023-11-22T14:50:33.103Z", "dateUpdated": "2024-08-02T21:46:29.185Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-49130\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-01-09T10:15:19.053\",\"lastModified\":\"2024-11-21T08:32:53.767\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Solid Edge SE2023 (All versions \u003c V223.0 Update 10). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Solid Edge SE2023 (todas las versiones \"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-824\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"223.0\",\"matchCriteriaId\":\"6708C521-2523-4FFE-8D66-01386DF0FAAF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"E0ADA2C0-4AA2-4FDB-AB71-2C905106A68F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*\",\"matchCriteriaId\":\"619B13A0-ADF3-4CC9-A5BD-6C99AE369D43\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*\",\"matchCriteriaId\":\"E4C4B3EA-853A-4C75-AA5F-319E2802A722\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*\",\"matchCriteriaId\":\"28C04B66-7E6F-49E6-B7A9-E7357ADE5936\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*\",\"matchCriteriaId\":\"99A72C67-00A3-499A-9DDC-73AD29672A08\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C7B34D6-925F-4DB9-8418-962F35FE11C6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*\",\"matchCriteriaId\":\"211C7830-D4B9-4315-BDE8-F108FF6A609C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*\",\"matchCriteriaId\":\"52647713-2F45-4D35-B31A-5BB2E15175EF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*\",\"matchCriteriaId\":\"4378378B-BAEA-4200-9336-936835322DF6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*\",\"matchCriteriaId\":\"57968030-2B5F-41C1-B8B4-2405C84E3A06\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-589891.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.