CVE-2023-4857 (GCVE-0-2023-4857)
Vulnerability from cvelistv5 – Published: 2024-04-15 18:00 – Updated: 2024-08-02 07:38
VLAI
EPSS
VEX
Summary
An authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-09 17:28 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
Impacted products
3 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Lenovo | SMM, SMM2, FPC |
Affected:
various
|
guessed | |
| lenovo | fan_power_controller |
Affected:
0 , < fhet62a-3.50
(custom)
cpe:2.3:a:lenovo:fan_power_controller:*:*:*:*:*:*:*:* |
||
| lenovo | system_management_module_firmware |
Affected:
1.24 , < tesm40b-1.27
(custom)
cpe:2.3:o:lenovo:system_management_module_firmware:1.24:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:lenovo:fan_power_controller:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "fan_power_controller",
"vendor": "lenovo",
"versions": [
{
"lessThan": "fhet62a-3.50",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:lenovo:system_management_module_firmware:1.24:*:*:*:*:*:*:*"
],
"defaultStatus": "affected",
"product": "system_management_module_firmware",
"vendor": "lenovo",
"versions": [
{
"lessThan": "tesm40b-1.27",
"status": "affected",
"version": "1.24",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4857",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T17:28:48.672549Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T19:59:02.276Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:38:00.772Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-140420"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SMM, SMM2, FPC",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information.\u003c/span\u003e\n\n"
}
],
"value": "\nAn authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-15T18:00:03.660Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-140420"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nUpdate \n\nSMM/SMM2 or FPC\n\n to the version (or newer) indicated for your model in the advisory: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.lenovo.com/us/en/product_security/LEN-140420\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-140420\u003c/a\u003e\u0026nbsp; \u0026nbsp;\n\n\u003cbr\u003e"
}
],
"value": "\nUpdate \n\nSMM/SMM2 or FPC\n\n to the version (or newer) indicated for your model in the advisory: https://support.lenovo.com/us/en/product_security/LEN-140420 \u00a0 \u00a0\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2023-4857",
"datePublished": "2024-04-15T18:00:03.660Z",
"dateReserved": "2023-09-08T19:23:06.855Z",
"dateUpdated": "2024-08-02T07:38:00.772Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-4857",
"date": "2026-09-30",
"epss": "0.0053",
"percentile": "0.42643"
},
"fkie_nvd": {
"descriptions": [
{
"lang": "en",
"value": "\nAn authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information.\n\n"
},
{
"lang": "es",
"value": "Se identific\u00f3 una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n en SMM/SMM2 y FPC que podr\u00eda permitir a un usuario autenticado ejecutar ciertas llamadas IPMI que podr\u00edan provocar la exposici\u00f3n de informaci\u00f3n limitada del sistema."
}
],
"id": "CVE-2023-4857",
"lastModified": "2024-11-21T08:36:07.400",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "psirt@lenovo.com",
"type": "Secondary"
}
]
},
"published": "2024-04-15T18:15:09.640",
"references": [
{
"source": "psirt@lenovo.com",
"url": "https://support.lenovo.com/us/en/product_security/LEN-140420"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://support.lenovo.com/us/en/product_security/LEN-140420"
}
],
"sourceIdentifier": "psirt@lenovo.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "psirt@lenovo.com",
"type": "Secondary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "SMM, SMM2, FPC",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"source": "psirt@lenovo.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:lenovo:fan_power_controller:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "fan_power_controller",
"vendor": "lenovo",
"versions": [
{
"lessThan": "fhet62a-3.50",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:lenovo:system_management_module_firmware:1.24:*:*:*:*:*:*:*"
],
"defaultStatus": "affected",
"product": "system_management_module_firmware",
"vendor": "lenovo",
"versions": [
{
"lessThan": "tesm40b-1.27",
"status": "affected",
"version": "1.24",
"versionType": "custom"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nAn authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information.\n\n"
},
{
"lang": "es",
"value": "Se identific\u00f3 una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n en SMM/SMM2 y FPC que podr\u00eda permitir a un usuario autenticado ejecutar ciertas llamadas IPMI que podr\u00edan provocar la exposici\u00f3n de informaci\u00f3n limitada del sistema."
}
],
"id": "CVE-2023-4857",
"lastModified": "2026-06-17T06:38:45.820",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "psirt@lenovo.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-4857",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T17:28:48.672549Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-04-15T18:15:09.640",
"references": [
{
"source": "psirt@lenovo.com",
"url": "https://support.lenovo.com/us/en/product_security/LEN-140420"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://support.lenovo.com/us/en/product_security/LEN-140420"
}
],
"sourceIdentifier": "psirt@lenovo.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "psirt@lenovo.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-29T00:21:57+00:00",
"cve": "CVE-2023-4857",
"id": "CVE-2023-4857",
"initial_release_date": "2023-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2023-4857",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-4857.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:38:00.772Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-140420"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:lenovo:fan_power_controller:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "fan_power_controller",
"vendor": "lenovo",
"versions": [
{
"lessThan": "fhet62a-3.50",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:lenovo:system_management_module_firmware:1.24:*:*:*:*:*:*:*"
],
"defaultStatus": "affected",
"product": "system_management_module_firmware",
"vendor": "lenovo",
"versions": [
{
"lessThan": "tesm40b-1.27",
"status": "affected",
"version": "1.24",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-4857",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T17:28:48.672549Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T17:35:25.658Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SMM, SMM2, FPC",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information.\u003c/span\u003e\n\n"
}
],
"value": "\nAn authentication bypass vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user to execute certain IPMI calls that could lead to exposure of limited system information.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-15T18:00:03.660Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"url": "https://support.lenovo.com/us/en/product_security/LEN-140420"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nUpdate \n\nSMM/SMM2 or FPC\n\n to the version (or newer) indicated for your model in the advisory: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.lenovo.com/us/en/product_security/LEN-140420\"\u003ehttps://support.lenovo.com/us/en/product_security/LEN-140420\u003c/a\u003e\u0026nbsp; \u0026nbsp;\n\n\u003cbr\u003e"
}
],
"value": "\nUpdate \n\nSMM/SMM2 or FPC\n\n to the version (or newer) indicated for your model in the advisory: https://support.lenovo.com/us/en/product_security/LEN-140420 \u00a0 \u00a0\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2023-4857",
"datePublished": "2024-04-15T18:00:03.660Z",
"dateReserved": "2023-09-08T19:23:06.855Z",
"dateUpdated": "2024-08-02T07:38:00.772Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…