Summary
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Parasolid V35.0 |
Version: All versions < V35.0.262 |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T20:21:16.597Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-45601", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-09-19T14:07:38.593206Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-19T14:07:50.300Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Parasolid V35.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V35.0.262" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V35.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V35.1.250" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V36.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V36.0.169" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2201", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2201.0009" } ] }, { "defaultStatus": "unknown", "product": "Tecnomatix Plant Simulation V2302", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2302.0003" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.262), Parasolid V35.1 (All versions \u003c V35.1.250), Parasolid V36.0 (All versions \u003c V36.0.169), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0009), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:21:47.253Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-45601", "datePublished": "2023-10-10T10:21:47.253Z", "dateReserved": "2023-10-09T09:36:15.785Z", "dateUpdated": "2024-09-19T14:07:50.300Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-45601\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-10-10T11:15:13.247\",\"lastModified\":\"2024-11-21T08:27:02.457\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.262), Parasolid V35.1 (All versions \u003c V35.1.250), Parasolid V36.0 (All versions \u003c V36.0.169), Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0009), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Parasolid V35.0 (Todas las versiones \u0026lt; V35.0.262), \\nParasolid V35.1 (Todas las versiones \u0026lt; V35.1.250), \\nParasolid V36.0 (Todas las versiones \u0026lt; V36.0.169), \\nTecnomatix Plant Simulation V2201 ( Todas las versiones \u0026lt; V2201.0009),\\nTecnomatix Plant Simulator V2302 (Todas las versiones \u0026lt; V2302.0003). \\nLas aplicaciones afectadas contienen una vulnerabilidad de desbordamiento de pila al analizar archivos IGS especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-21290)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.0\",\"versionEndExcluding\":\"35.0.262\",\"matchCriteriaId\":\"1C96074D-757B-4A3F-8B04-504D52DBE0EE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.1\",\"versionEndExcluding\":\"35.1.250\",\"matchCriteriaId\":\"78258279-F7F6-4057-8AE2-AF64387B04BB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"36.0\",\"versionEndExcluding\":\"36.0.169\",\"matchCriteriaId\":\"97086FB9-6392-4B6D-8CD4-EA780AE4DD05\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2201\",\"versionEndExcluding\":\"2201.0009\",\"matchCriteriaId\":\"ECCC6F17-BB3D-4FD0-B277-5DD86EB4C9F7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2302\",\"versionEndExcluding\":\"2302.0003\",\"matchCriteriaId\":\"C29307AD-B728-41D3-9D57-FD5D1D51ACFA\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.