CVE-2023-4542 (GCVE-0-2023-4542)
Vulnerability from cvelistv5 – Published: 2023-08-25 21:31 – Updated: 2024-08-02 07:31
VLAI
KEVintel KEV
Title
D-Link DAR-8000-10 sys1.php os command injection
Summary
A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
6.3 (Medium)
6.3 (Medium)
CWE
- CWE-78 - OS Command Injection
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.238047 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.238047 | signaturepermissions-required |
| https://github.com/PumpkinBridge/cve/blob/main/rce.md | exploit |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| D-Link | DAR-8000-10 |
Affected:
20230809
|
Credits
KEVintel KEV
Known Exploited Vulnerability - GCVE BCP-07 Compliant
KEV entry ID: 32827687-d52a-4aed-8afe-f20d40e1a688
Exploited: Yes
Timestamps
First Seen: 2026-03-19
Asserted: 2026-03-19
Scope
Notes: KEVIntel entry: D-Link DAR-8000-10 sys1.php os command injection | Affected: D-Link / DAR-8000-10 | CVSS: 6.3 (MEDIUM) | Used in malware: unknown | Not yet in CISA KEV: True
Evidence
Type: Public Report
Signal: Successful Exploitation
Confidence: 70%
Source: kevintel
Details
| Feed | KEVIntel (kevintel.com) |
|---|---|
| Title | D-Link DAR-8000-10 sys1.php os command injection |
| Vendor | D-Link |
| Product | DAR-8000-10 |
| Added Date | 2026-03-19T00:00:00.000Z |
| Cvss Score | 6.3 |
| Epss Score | None |
| Cvss Severity | MEDIUM |
| Epss Percentile | None |
| Used In Malware | unknown |
| Ahead Of Cisa Kev | None |
| Not Yet In Cisa Kev | True |
References
Created: 2026-06-19 12:45 UTC
| Updated: 2026-06-19 12:45 UTC
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:31:06.464Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.238047"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.238047"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/PumpkinBridge/cve/blob/main/rce.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DAR-8000-10",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "20230809"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "analyst",
"value": "PumkinBridge (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in D-Link DAR-8000-10 bis 20230809 ausgemacht. Sie wurde als kritisch eingestuft. Es geht dabei um eine nicht klar definierte Funktion der Datei /app/sys1.php. Durch das Manipulieren des Arguments cmd mit der Eingabe id mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-24T14:48:55.188Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.238047"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.238047"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/PumpkinBridge/cve/blob/main/rce.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2023-08-25T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2023-08-25T00:00:00.000Z",
"value": "CVE reserved"
},
{
"lang": "en",
"time": "2023-08-25T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2023-09-20T12:46:37.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-8000-10 sys1.php os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2023-4542",
"datePublished": "2023-08-25T21:31:04.605Z",
"dateReserved": "2023-08-25T15:18:48.598Z",
"dateUpdated": "2024-08-02T07:31:06.464Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-4542",
"date": "2026-06-19",
"epss": "0.86533",
"percentile": "0.99712"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dlink:dar-8000-10_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2023-08-09\", \"matchCriteriaId\": \"5D24E42C-A511-4AB7-A6AC-D6036869B481\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dlink:dar-8000-10:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D44DF047-CB1C-47CE-AC33-60F8859F242F\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}]",
"id": "CVE-2023-4542",
"lastModified": "2024-11-21T08:35:22.903",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P\", \"baseScore\": 6.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2023-08-25T22:15:11.457",
"references": "[{\"url\": \"https://github.com/PumpkinBridge/cve/blob/main/rce.md\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?ctiid.238047\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Permissions Required\", \"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?id.238047\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://github.com/PumpkinBridge/cve/blob/main/rce.md\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?ctiid.238047\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Permissions Required\", \"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?id.238047\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cna@vuldb.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-4542\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2023-08-25T22:15:11.457\",\"lastModified\":\"2024-11-21T08:35:22.903\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was found in D-Link DAR-8000-10 up to 20230809. It has been classified as critical. This affects an unknown part of the file /app/sys1.php. The manipulation of the argument cmd with the input id leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-238047. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dlink:dar-8000-10_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2023-08-09\",\"matchCriteriaId\":\"5D24E42C-A511-4AB7-A6AC-D6036869B481\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dlink:dar-8000-10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D44DF047-CB1C-47CE-AC33-60F8859F242F\"}]}]}],\"references\":[{\"url\":\"https://github.com/PumpkinBridge/cve/blob/main/rce.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.238047\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?id.238047\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://github.com/PumpkinBridge/cve/blob/main/rce.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.238047\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Permissions Required\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?id.238047\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…