cve-2023-44315
Vulnerability from cvelistv5
Published
2023-10-10 10:21
Modified
2024-08-02 19:59
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SINEC NMS (All versions < V2.0). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could prepare a stored cross-site scripting (XSS) attack that may lead to unintentional modification of application data by legitimate users.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:59:52.165Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160243.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-160243.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SINEC NMS", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEC NMS (All versions \u003c V2.0). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could prepare a stored cross-site scripting (XSS) attack that may lead to unintentional modification of application data by legitimate users." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:04:29.466Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160243.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-160243.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-44315", "datePublished": "2023-10-10T10:21:41.852Z", "dateReserved": "2023-09-28T13:54:53.927Z", "dateUpdated": "2024-08-02T19:59:52.165Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-44315\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-10-10T11:15:12.993\",\"lastModified\":\"2024-11-21T08:25:39.047\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEC NMS (All versions \u003c V2.0). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could prepare a stored cross-site scripting (XSS) attack that may lead to unintentional modification of application data by legitimate users.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones \u0026lt; V2.0). La aplicaci\u00f3n afectada sanitiza incorrectamente ciertos datos de configuraci\u00f3n SNMP recuperados de los dispositivos monitorizados. Un atacante con acceso a un dispositivo monitorizado podr\u00eda preparar un ataque de Cross-Site Scripting (XSS) almacenado que puede llevar a la modificaci\u00f3n no intencionada de los datos de la aplicaci\u00f3n por parte de usuarios leg\u00edtimos.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":4.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.6,\"impactScore\":2.7},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.0\",\"matchCriteriaId\":\"A7F0A543-38E1-48B9-A984-259081E49EAA\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-160243.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-160243.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-160243.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-160243.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.