CVE-2023-34316 (GCVE-0-2023-34316)
Vulnerability from cvelistv5
Published
2023-07-10 19:01
Modified
2025-01-27 16:20
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Summary
An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01 | Mitigation, Patch, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01 | Mitigation, Patch, Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Delta Electronics | Infrasuite Device Master |
Version: 0 < v1.0.7 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:10:06.493Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-34316", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-23T17:57:29.955732Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-23T17:59:29.374Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Infrasuite Device Master", "vendor": "Delta Electronics", "versions": [ { "lessThan": "v1.0.7", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "\u200bPiotr Bazydlo of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA." } ], "datePublic": "2023-06-29T17:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u200bAn attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents.\u003c/span\u003e" } ], "value": "\u200bAn attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-552", "description": "CWE-552 Files or Directories Accessible to External Parties", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-27T16:20:03.560Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003e\u200bDelta Electronics has provided a fix to these vulnerabilities. Users are encouraged to update to the latest version.\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u200bDelta Electronics InfraSuite Device Master: Update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.7(x64).exe\"\u003ev1.0.7\u003c/a\u003e.\u003c/li\u003e\u003c/ul\u003e" } ], "value": "\u200bDelta Electronics has provided a fix to these vulnerabilities. Users are encouraged to update to the latest version.\n\n * \u200bDelta Electronics InfraSuite Device Master: Update to v1.0.7 https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.7(x64).exe ." } ], "source": { "advisory": "ICSA-23-180-01", "discovery": "EXTERNAL" }, "title": "Delta Electronics InfraSuite Device Master Improper Access Control", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2023-34316", "datePublished": "2023-07-10T19:01:51.280Z", "dateReserved": "2023-06-06T14:32:07.393Z", "dateUpdated": "2025-01-27T16:20:03.560Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-34316\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2023-07-10T20:15:15.310\",\"lastModified\":\"2025-01-27T17:15:14.840\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\u200bAn attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-552\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.7\",\"matchCriteriaId\":\"120F164B-0D4F-4E78-93E2-02A65EB210BE\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Patch\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Patch\",\"Third Party Advisory\",\"US Government Resource\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T16:10:06.493Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-34316\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-23T17:57:29.955732Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-23T17:59:21.671Z\"}}], \"cna\": {\"title\": \"Delta Electronics InfraSuite Device Master Improper Access Control\", \"source\": {\"advisory\": \"ICSA-23-180-01\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"\\u200bPiotr Bazydlo of Trend Micro\\u2019s Zero Day Initiative reported these vulnerabilities to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Delta Electronics\", \"product\": \"Infrasuite Device Master\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"v1.0.7\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"\\u200bDelta Electronics has provided a fix to these vulnerabilities. Users are encouraged to update to the latest version.\\n\\n * \\u200bDelta Electronics InfraSuite Device Master: Update to v1.0.7 https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.7(x64).exe .\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003e\\u200bDelta Electronics has provided a fix to these vulnerabilities. Users are encouraged to update to the latest version.\u003c/p\u003e\u003cul\u003e\u003cli\u003e\\u200bDelta Electronics InfraSuite Device Master: Update to \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://datacenter-softwarecenter.deltaww.com/Download/UPS/Software/InfraSuite_Device_Master_1.0.7(x64).exe\\\"\u003ev1.0.7\u003c/a\u003e.\u003c/li\u003e\u003c/ul\u003e\", \"base64\": false}]}], \"datePublic\": \"2023-06-29T17:00:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-01\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\u200bAn attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\\u200bAn attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents.\u003c/span\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-552\", \"description\": \"CWE-552 Files or Directories Accessible to External Parties\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2025-01-27T16:20:03.560Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2023-34316\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-27T16:20:03.560Z\", \"dateReserved\": \"2023-06-06T14:32:07.393Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2023-07-10T19:01:51.280Z\", \"assignerShortName\": \"icscert\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…