Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2023-28832 (GCVE-0-2023-28832)
Vulnerability from cvelistv5
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Cloud Connect 7 CC712 |
Version: All versions >= V2.0 < V2.1 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T13:51:38.923Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28832",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-28T18:42:31.147318Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-28T18:42:40.340Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Cloud Connect 7 CC712",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.0 \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Cloud Connect 7 CC716",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.0 \u003c V2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-09T11:51:28.740Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-28832",
"datePublished": "2023-05-09T11:51:28.740Z",
"dateReserved": "2023-03-24T15:17:33.934Z",
"dateUpdated": "2025-01-28T18:42:40.340Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2023-28832\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-05-09T13:15:17.373\",\"lastModified\":\"2024-11-21T07:56:06.930\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk1411-1ac00_firmware:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A1F685FA-A737-4D3D-AF47-837D30EBD898\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk1411-1ac00:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A62A87CC-250C-469E-9D2C-187271020EE6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:6gk1411-5ac00_firmware:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CAD8CE67-41F5-4673-BC79-EF290971FF20\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:6gk1411-5ac00:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7804B194-FECA-4D73-9D49-4B7E8FD49258\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T13:51:38.923Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-28832\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-28T18:42:31.147318Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-28T18:42:36.586Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SIMATIC Cloud Connect 7 CC712\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003e= V2.0 \u003c V2.1\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Cloud Connect 7 CC716\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003e= V2.0 \u003c V2.1\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2023-05-09T11:51:28.740Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-28832\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-28T18:42:40.340Z\", \"dateReserved\": \"2023-03-24T15:17:33.934Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2023-05-09T11:51:28.740Z\", \"assignerShortName\": \"siemens\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
icsa-23-131-04
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SIMATIC Cloud Connect 7 contains multiple vulnerabilities that could allow an attacker to impact its confidentiality, integrity and availability.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-555292: Security Vulnerabilities Fixed in SIMATIC Cloud Connect 7 V2.1 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-555292.json"
},
{
"category": "self",
"summary": "SSA-555292: Security Vulnerabilities Fixed in SIMATIC Cloud Connect 7 V2.1 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-555292.html"
},
{
"category": "self",
"summary": "SSA-555292: Security Vulnerabilities Fixed in SIMATIC Cloud Connect 7 V2.1 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
},
{
"category": "self",
"summary": "SSA-555292: Security Vulnerabilities Fixed in SIMATIC Cloud Connect 7 V2.1 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-555292.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-131-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-131-04.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-131-04 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC Cloud Connect 7",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-131-04",
"initial_release_date": "2023-05-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-05-09T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=V2.0\u003cV2.1",
"product": {
"name": "SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"model_numbers": [
"6GK1411-1AC00"
]
}
}
},
{
"category": "product_version_range",
"name": "\u003cV2.1",
"product": {
"name": "SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)",
"product_id": "CSAFPID-0002",
"product_identification_helper": {
"model_numbers": [
"6GK1411-1AC00"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=V2.0\u003cV2.1",
"product": {
"name": "SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)",
"product_id": "CSAFPID-0003",
"product_identification_helper": {
"model_numbers": [
"6GK1411-5AC00"
]
}
}
},
{
"category": "product_version_range",
"name": "\u003cV2.1",
"product": {
"name": "SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)",
"product_id": "CSAFPID-0004",
"product_identification_helper": {
"model_numbers": [
"6GK1411-5AC00"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-28832",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-28832"
},
{
"cve": "CVE-2023-29103",
"cwe": {
"id": "CWE-259",
"name": "Use of Hard-coded Password"
},
"notes": [
{
"category": "summary",
"text": "The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected data.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2023-29103"
},
{
"cve": "CVE-2023-29104",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to overwrite any file the Linux user `ccuser` has write access to, or to download any file the Linux user `ccuser` has read-only access to.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.0,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-29104"
},
{
"cve": "CVE-2023-29105",
"cwe": {
"id": "CWE-544",
"name": "Missing Standardized Error Handling Mechanism"
},
"notes": [
{
"category": "summary",
"text": "The affected device is vulnerable to a denial of service while parsing a random (non-JSON) MQTT payload. This could allow an attacker who can manipulate the communication between the MQTT broker and the affected device to cause a denial of service (DoS).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2023-29105"
},
{
"cve": "CVE-2023-29106",
"cwe": {
"id": "CWE-200",
"name": "Exposure of Sensitive Information to an Unauthorized Actor"
},
"notes": [
{
"category": "summary",
"text": "The export endpoint is accessible via REST API without authentication. This could allow an unauthenticated remote attacker to download the files available via the endpoint.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-29106"
},
{
"cve": "CVE-2023-29107",
"cwe": {
"id": "CWE-552",
"name": "Files or Directories Accessible to External Parties"
},
"notes": [
{
"category": "summary",
"text": "The export endpoint discloses some undocumented files. This could allow an unauthenticated remote attacker to gain access to additional information resources.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-29107"
},
{
"cve": "CVE-2023-29128",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.8,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-29128"
}
]
}
ICSA-23-131-04
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SIMATIC Cloud Connect 7 contains multiple vulnerabilities that could allow an attacker to impact its confidentiality, integrity and availability.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-555292: Security Vulnerabilities Fixed in SIMATIC Cloud Connect 7 V2.1 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-555292.json"
},
{
"category": "self",
"summary": "SSA-555292: Security Vulnerabilities Fixed in SIMATIC Cloud Connect 7 V2.1 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-555292.html"
},
{
"category": "self",
"summary": "SSA-555292: Security Vulnerabilities Fixed in SIMATIC Cloud Connect 7 V2.1 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
},
{
"category": "self",
"summary": "SSA-555292: Security Vulnerabilities Fixed in SIMATIC Cloud Connect 7 V2.1 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-555292.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-131-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-131-04.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-131-04 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC Cloud Connect 7",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-131-04",
"initial_release_date": "2023-05-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-05-09T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=V2.0\u003cV2.1",
"product": {
"name": "SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"model_numbers": [
"6GK1411-1AC00"
]
}
}
},
{
"category": "product_version_range",
"name": "\u003cV2.1",
"product": {
"name": "SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)",
"product_id": "CSAFPID-0002",
"product_identification_helper": {
"model_numbers": [
"6GK1411-1AC00"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003e=V2.0\u003cV2.1",
"product": {
"name": "SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)",
"product_id": "CSAFPID-0003",
"product_identification_helper": {
"model_numbers": [
"6GK1411-5AC00"
]
}
}
},
{
"category": "product_version_range",
"name": "\u003cV2.1",
"product": {
"name": "SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)",
"product_id": "CSAFPID-0004",
"product_identification_helper": {
"model_numbers": [
"6GK1411-5AC00"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-28832",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-28832"
},
{
"cve": "CVE-2023-29103",
"cwe": {
"id": "CWE-259",
"name": "Use of Hard-coded Password"
},
"notes": [
{
"category": "summary",
"text": "The affected device uses a hard-coded password to protect the diagnostic files. This could allow an authenticated attacker to access protected data.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2023-29103"
},
{
"cve": "CVE-2023-29104",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to overwrite any file the Linux user `ccuser` has write access to, or to download any file the Linux user `ccuser` has read-only access to.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.0,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-29104"
},
{
"cve": "CVE-2023-29105",
"cwe": {
"id": "CWE-544",
"name": "Missing Standardized Error Handling Mechanism"
},
"notes": [
{
"category": "summary",
"text": "The affected device is vulnerable to a denial of service while parsing a random (non-JSON) MQTT payload. This could allow an attacker who can manipulate the communication between the MQTT broker and the affected device to cause a denial of service (DoS).",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004"
]
}
],
"title": "CVE-2023-29105"
},
{
"cve": "CVE-2023-29106",
"cwe": {
"id": "CWE-200",
"name": "Exposure of Sensitive Information to an Unauthorized Actor"
},
"notes": [
{
"category": "summary",
"text": "The export endpoint is accessible via REST API without authentication. This could allow an unauthenticated remote attacker to download the files available via the endpoint.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-29106"
},
{
"cve": "CVE-2023-29107",
"cwe": {
"id": "CWE-552",
"name": "Files or Directories Accessible to External Parties"
},
"notes": [
{
"category": "summary",
"text": "The export endpoint discloses some undocumented files. This could allow an unauthenticated remote attacker to gain access to additional information resources.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-29107"
},
{
"cve": "CVE-2023-29128",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V2.1 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109818318/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.8,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2023-29128"
}
]
}
gsd-2023-28832
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2023-28832",
"id": "GSD-2023-28832"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-28832"
],
"details": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.",
"id": "GSD-2023-28832",
"modified": "2023-12-13T01:20:48.762851Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2023-28832",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC Cloud Connect 7 CC712",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V2.0 \u003c V2.1"
}
]
}
},
{
"product_name": "SIMATIC Cloud Connect 7 CC716",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V2.0 \u003c V2.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
]
},
"impact": {
"cvss": [
{
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-77",
"lang": "eng",
"value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:6gk1411-1ac00_firmware:2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:6gk1411-1ac00:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:6gk1411-5ac00_firmware:2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:6gk1411-5ac00:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2023-28832"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf",
"refsource": "MISC",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-05-15T18:49Z",
"publishedDate": "2023-05-09T13:15Z"
}
}
}
CERTFR-2023-AVI-0370
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service, une atteinte à l'intégrité des données, un contournement de la politique de sécurité, une atteinte à la confidentialité des données, un déni de service à distance et une exécution de code arbitraire.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0) versions antérieures à V7.0.3 | ||
| Siemens | N/A | Siveillance Video 2022 R1 versions antérieures à V22.1 HotfixRev7 | ||
| Siemens | N/A | Siveillance Video 2021 R1 versions antérieures à V21.1 HotfixRev12 | ||
| Siemens | N/A | SCALANCE LPE9403 (6GK5998-3GS00-2AC2) versions antérieures à V2.1 | ||
| Siemens | N/A | Siveillance Video 2022 R2 versions antérieures à V22.2 HotfixRev5 | ||
| Siemens | N/A | SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0) toutes versions | ||
| Siemens | N/A | SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0) versions antérieures à V7.0.3 | ||
| Siemens | N/A | SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0) versions antérieures à V7.0.3 | ||
| Siemens | N/A | SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0) toutes versions | ||
| Siemens | N/A | Siveillance Video 2020 R3 versions antérieures à V20.3 HotfixRev12 | ||
| Siemens | N/A | Siveillance Video 2022 R3 versions antérieures à V22.3 HotfixRev2 | ||
| Siemens | N/A | Siveillance Video 2023 R1 versions antérieures à V23.1 HotfixRev1 | ||
| Siemens | N/A | Siveillance Video 2020 R2 versions antérieures à V20.2 HotfixRev14 | ||
| Siemens | N/A | Siveillance Video 2021 R2 versions antérieures à V21.2 HotfixRev8 | ||
| Siemens | N/A | SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00) versions V2.x versions antérieures à V2.1 | ||
| Siemens | N/A | SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) versions V2.x versions antérieures à V2.1 | ||
| Siemens | N/A | SINEC NMS versions antérieures à V1.0.3.1 | ||
| Siemens | N/A | SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0) versions antérieures à V7.0.3 | ||
| Siemens | N/A | SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0) toutes versions | ||
| Siemens | N/A | SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0) versions antérieures à V7.0.3 | ||
| Siemens | N/A | Solid Edge SE2023 versions antérieures à VX.223.0 Update 3 |
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0) versions ant\u00e9rieures \u00e0 V7.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video 2022 R1 versions ant\u00e9rieures \u00e0 V22.1 HotfixRev7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video 2021 R1 versions ant\u00e9rieures \u00e0 V21.1 HotfixRev12",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE LPE9403 (6GK5998-3GS00-2AC2) versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video 2022 R2 versions ant\u00e9rieures \u00e0 V22.2 HotfixRev5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0) versions ant\u00e9rieures \u00e0 V7.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0) versions ant\u00e9rieures \u00e0 V7.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video 2020 R3 versions ant\u00e9rieures \u00e0 V20.3 HotfixRev12",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video 2022 R3 versions ant\u00e9rieures \u00e0 V22.3 HotfixRev2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video 2023 R1 versions ant\u00e9rieures \u00e0 V23.1 HotfixRev1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video 2020 R2 versions ant\u00e9rieures \u00e0 V20.2 HotfixRev14",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video 2021 R2 versions ant\u00e9rieures \u00e0 V21.2 HotfixRev8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00) versions V2.x versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) versions V2.x versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEC NMS versions ant\u00e9rieures \u00e0 V1.0.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0) versions ant\u00e9rieures \u00e0 V7.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0) versions ant\u00e9rieures \u00e0 V7.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2023 versions ant\u00e9rieures \u00e0 VX.223.0 Update 3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-35252",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35252"
},
{
"name": "CVE-2022-35260",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35260"
},
{
"name": "CVE-2023-28832",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28832"
},
{
"name": "CVE-2023-0973",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0973"
},
{
"name": "CVE-2023-29105",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29105"
},
{
"name": "CVE-2023-29128",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29128"
},
{
"name": "CVE-2022-42916",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42916"
},
{
"name": "CVE-2023-27407",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27407"
},
{
"name": "CVE-2023-29104",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29104"
},
{
"name": "CVE-2023-27409",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27409"
},
{
"name": "CVE-2022-43552",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43552"
},
{
"name": "CVE-2019-10936",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10936"
},
{
"name": "CVE-2023-30985",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30985"
},
{
"name": "CVE-2023-30899",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30899"
},
{
"name": "CVE-2023-29107",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29107"
},
{
"name": "CVE-2022-42915",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42915"
},
{
"name": "CVE-2022-32221",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32221"
},
{
"name": "CVE-2022-40674",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40674"
},
{
"name": "CVE-2022-43551",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43551"
},
{
"name": "CVE-2022-47522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47522"
},
{
"name": "CVE-2022-43680",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43680"
},
{
"name": "CVE-2023-27410",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27410"
},
{
"name": "CVE-2023-29106",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29106"
},
{
"name": "CVE-2023-30986",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30986"
},
{
"name": "CVE-2023-30898",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30898"
},
{
"name": "CVE-2023-27408",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27408"
},
{
"name": "CVE-2023-29103",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29103"
}
],
"initial_release_date": "2023-05-10T00:00:00",
"last_revision_date": "2023-05-10T00:00:00",
"links": [],
"reference": "CERTFR-2023-AVI-0370",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-05-10T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eles produits Siemens\u003c/span\u003e. Elles permettent \u00e0 un\nattaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un\nd\u00e9ni de service, une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es, un\ncontournement de la politique de s\u00e9curit\u00e9, une atteinte \u00e0 la\nconfidentialit\u00e9 des donn\u00e9es, un d\u00e9ni de service \u00e0 distance et une\nex\u00e9cution de code arbitraire.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-789345 du 09 mai 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-516174.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-325383 du 09 mai 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-789345.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-516174 du 09 mai 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-555292.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-932528 du 09 mai 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-892048.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-892048 du 09 mai 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-325383.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-555292 du 09 mai 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-932528.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-473245 du 08 octobre 2019",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html"
}
]
}
ghsa-p96q-9p2w-4j2c
Vulnerability from github
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
{
"affected": [],
"aliases": [
"CVE-2023-28832"
],
"database_specific": {
"cwe_ids": [
"CWE-77"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-05-09T13:15:17Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.",
"id": "GHSA-p96q-9p2w-4j2c",
"modified": "2024-04-04T03:55:15Z",
"published": "2023-05-09T15:30:32Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-28832"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
cnvd-2023-35774
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/html/ssa-555292.html
| Name | ['Siemens SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00) >= V2.0,< V2.1', 'Siemens SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) >= V2.0,< V2.1'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2023-28832"
}
},
"description": "SIMATIC Cloud Connect 7\u662f\u4e00\u79cd\u7269\u8054\u7f51\u7f51\u5173\uff0c\u7528\u4e8e\u5c06\u53ef\u7f16\u7a0b\u903b\u8f91\u63a7\u5236\u5668\u8fde\u63a5\u5230\u4e91\u670d\u52a1\uff0c\u5e76\u5141\u8bb8\u5c06\u73b0\u573a\u8bbe\u5907\u4e0eOPC UA\u670d\u52a1\u5668\u63a5\u53e3\u8fde\u63a5\u4e3aOPC UA\u5ba2\u6237\u7aef\u3002\n\nSiemens SIMATIC Cloud Connect 7\u5b58\u5728\u547d\u4ee4\u6ce8\u5165\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u4ee5root\u6743\u9650\u6267\u884c\u4efb\u610f\u4ee3\u7801\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-555292.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2023-35774",
"openTime": "2023-05-10",
"patchDescription": "SIMATIC Cloud Connect 7\u662f\u4e00\u79cd\u7269\u8054\u7f51\u7f51\u5173\uff0c\u7528\u4e8e\u5c06\u53ef\u7f16\u7a0b\u903b\u8f91\u63a7\u5236\u5668\u8fde\u63a5\u5230\u4e91\u670d\u52a1\uff0c\u5e76\u5141\u8bb8\u5c06\u73b0\u573a\u8bbe\u5907\u4e0eOPC UA\u670d\u52a1\u5668\u63a5\u53e3\u8fde\u63a5\u4e3aOPC UA\u5ba2\u6237\u7aef\u3002\r\n\r\nSiemens SIMATIC Cloud Connect 7\u5b58\u5728\u547d\u4ee4\u6ce8\u5165\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u4ee5root\u6743\u9650\u6267\u884c\u4efb\u610f\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens SIMATIC Cloud Connect 7\u547d\u4ee4\u6ce8\u5165\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Siemens SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00) \u003e= V2.0\uff0c\u003c V2.1",
"Siemens SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) \u003e= V2.0\uff0c\u003c V2.1"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-555292.html",
"serverity": "\u9ad8",
"submitTime": "2023-05-10",
"title": "Siemens SIMATIC Cloud Connect 7\u547d\u4ee4\u6ce8\u5165\u6f0f\u6d1e"
}
fkie_cve-2023-28832
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf | Patch, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | 6gk1411-1ac00_firmware | 2.0 | |
| siemens | 6gk1411-1ac00 | - | |
| siemens | 6gk1411-5ac00_firmware | 2.0 | |
| siemens | 6gk1411-5ac00 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6gk1411-1ac00_firmware:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "A1F685FA-A737-4D3D-AF47-837D30EBD898",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6gk1411-1ac00:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A62A87CC-250C-469E-9D2C-187271020EE6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:6gk1411-5ac00_firmware:2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "CAD8CE67-41F5-4673-BC79-EF290971FF20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:6gk1411-5ac00:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7804B194-FECA-4D73-9D49-4B7E8FD49258",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges."
}
],
"id": "CVE-2023-28832",
"lastModified": "2024-11-21T07:56:06.930",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Primary"
}
]
},
"published": "2023-05-09T13:15:17.373",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
var-202305-0430
Vulnerability from variot
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. Siemens' 6gk1411-1ac00 firmware and 6gk1411-5ac00 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices to be interfaced with OPC UA servers as OPC UA clients
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202305-0430",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "6gk1411-1ac00",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "2.0"
},
{
"model": "6gk1411-5ac00",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "2.0"
},
{
"model": "6gk1411-5ac00",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "6gk1411-1ac00",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic cloud connect cc716",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7\u003e=v2.0,\u003cv2.1"
},
{
"model": "simatic cloud connect cc712",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7\u003e=v2.0,\u003cv2.1"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-35774"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-009653"
},
{
"db": "NVD",
"id": "CVE-2023-28832"
}
]
},
"cve": "CVE-2023-28832",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-35774",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"id": "CVE-2023-28832",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.2,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2023-009653",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2023-28832",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2023-009653",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-35774",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202305-650",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-35774"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-009653"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-650"
},
{
"db": "NVD",
"id": "CVE-2023-28832"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions \u003e= V2.0 \u003c V2.1), SIMATIC Cloud Connect 7 CC716 (All versions \u003e= V2.0 \u003c V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. Siemens\u0027 6gk1411-1ac00 firmware and 6gk1411-5ac00 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SIMATIC Cloud Connect 7 is an IoT gateway for connecting programmable logic controllers to cloud services and allows field devices to be interfaced with OPC UA servers as OPC UA clients",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-28832"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-009653"
},
{
"db": "CNVD",
"id": "CNVD-2023-35774"
},
{
"db": "VULMON",
"id": "CVE-2023-28832"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-28832",
"trust": 3.9
},
{
"db": "SIEMENS",
"id": "SSA-555292",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU98195668",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-131-04",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-009653",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-35774",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202305-650",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-28832",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-35774"
},
{
"db": "VULMON",
"id": "CVE-2023-28832"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-009653"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-650"
},
{
"db": "NVD",
"id": "CVE-2023-28832"
}
]
},
"id": "VAR-202305-0430",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-35774"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-35774"
}
]
},
"last_update_date": "2024-08-14T12:04:34.126000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens SIMATIC Cloud Connect 7 Command Injection Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/424686"
},
{
"title": "Siemens SIMATIC Cloud Connect Fixes for command injection vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=237051"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-35774"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-650"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "Command injection (CWE-77) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-009653"
},
{
"db": "NVD",
"id": "CVE-2023-28832"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555292.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-28832"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu98195668/"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-131-04"
},
{
"trust": 0.6,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-555292.html"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-28832/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/77.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-35774"
},
{
"db": "VULMON",
"id": "CVE-2023-28832"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-009653"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-650"
},
{
"db": "NVD",
"id": "CVE-2023-28832"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-35774"
},
{
"db": "VULMON",
"id": "CVE-2023-28832"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-009653"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-650"
},
{
"db": "NVD",
"id": "CVE-2023-28832"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-05-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-35774"
},
{
"date": "2023-05-09T00:00:00",
"db": "VULMON",
"id": "CVE-2023-28832"
},
{
"date": "2023-12-06T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-009653"
},
{
"date": "2023-05-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202305-650"
},
{
"date": "2023-05-09T13:15:17.373000",
"db": "NVD",
"id": "CVE-2023-28832"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-05-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-35774"
},
{
"date": "2023-05-09T00:00:00",
"db": "VULMON",
"id": "CVE-2023-28832"
},
{
"date": "2023-12-06T05:17:00",
"db": "JVNDB",
"id": "JVNDB-2023-009653"
},
{
"date": "2023-05-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202305-650"
},
{
"date": "2023-05-15T18:49:38.067000",
"db": "NVD",
"id": "CVE-2023-28832"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202305-650"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a06gk1411-1ac00\u00a0 firmware and \u00a06gk1411-5ac00\u00a0 Command injection vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-009653"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202305-650"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.