cve-2022-43990
Vulnerability from cvelistv5
Published
2022-11-01 00:00
Modified
2024-08-03 13:47
Severity ?
Summary
Password recovery vulnerability in SICK SIM1012 Partnumber 1098146 with firmware version <2.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.2.0 as soon as possible (available in SICK Support Portal).
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:47:04.621Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://sick.com/psirt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SICK SIM1012",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Partnumber 1098146 with firmware version \u003c 2.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Password recovery vulnerability in SICK SIM1012 Partnumber 1098146 with firmware version \u003c2.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version \u003e= 2.2.0 as soon as possible (available in SICK Support Portal)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-16T00:00:00",
        "orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
        "shortName": "SICK AG"
      },
      "references": [
        {
          "url": "https://sick.com/psirt"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
    "assignerShortName": "SICK AG",
    "cveId": "CVE-2022-43990",
    "datePublished": "2022-11-01T00:00:00",
    "dateReserved": "2022-10-28T00:00:00",
    "dateUpdated": "2024-08-03T13:47:04.621Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-43990\",\"sourceIdentifier\":\"psirt@sick.de\",\"published\":\"2022-11-01T21:15:12.037\",\"lastModified\":\"2024-11-21T07:27:29.280\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Password recovery vulnerability in SICK SIM1012 Partnumber 1098146 with firmware version \u003c2.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version \u003e= 2.2.0 as soon as possible (available in SICK Support Portal).\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de recuperaci\u00f3n de contrase\u00f1a en SICK SIM1012 Partnumber 1098146 con versi\u00f3n de firmware \u0026lt;2.2.0, permite a un atacante remoto sin privilegios obtener acceso al nivel de usuario definido como RecoverableUserLevel invocando el m\u00e9todo del mecanismo de recuperaci\u00f3n de contrase\u00f1a. Esto conduce a un aumento de sus privilegios en el sistema y, por lo tanto, afecta la integridad de la confidencialidad y la disponibilidad del sistema. Un atacante puede esperar un \u00e9xito repetible si explota la vulnerabilidad. La soluci\u00f3n recomendada es actualizar el firmware a una versi\u00f3n \u0026gt;= 2.2.0 lo antes posible (disponible en el Portal de Soporte de SICK).\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":3.4}]},\"weaknesses\":[{\"source\":\"psirt@sick.de\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:sick:sim1012-0p0g200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.2.0\",\"matchCriteriaId\":\"9DEC7FF9-A5FA-4A40-B8A1-E0A3568D6939\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:sick:sim1012-0p0g200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F9A757D0-FA59-4F71-95B9-2F1E2B991867\"}]}]}],\"references\":[{\"url\":\"https://sick.com/psirt\",\"source\":\"psirt@sick.de\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://sick.com/psirt\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.