CVE-2022-43376 (GCVE-0-2022-43376)
Vulnerability from cvelistv5 – Published: 2023-04-18 19:55 – Updated: 2025-02-05 20:05
VLAI
EPSS
VEX
Summary
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site
Scripting') vulnerability exists that could cause code and session manipulation when malicious
code is inserted into the browser.
Affected Products: NetBotz 4 - 355/450/455/550/570 (V4.7.0
and prior)
Severity
7.6 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-05 19:50 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Schneider Electric | NetBotz 4 - 355/450/455/550/570 |
Affected:
V4.7.0 and prior
|
guessed |
Date Public
2022-11-08 08:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:32:58.339Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43376",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:50:33.636877Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:05:07.304Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "NetBotz 4 - 355/450/455/550/570",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "V4.7.0 and prior"
}
]
}
],
"datePublic": "2022-11-08T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause code and session manipulation when malicious\ncode is inserted into the browser.\n\n Affected Products: NetBotz 4 - 355/450/455/550/570\u0026nbsp;(V4.7.0\n\n and prior)"
}
],
"value": "\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause code and session manipulation when malicious\ncode is inserted into the browser.\n\n Affected Products: NetBotz 4 - 355/450/455/550/570\u00a0(V4.7.0\n\n and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-18T19:55:07.347Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-43376",
"datePublished": "2023-04-18T19:55:07.347Z",
"dateReserved": "2022-10-17T16:42:12.652Z",
"dateUpdated": "2025-02-05T20:05:07.304Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-43376",
"date": "2026-09-22",
"epss": "0.00379",
"percentile": "0.31855"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:netbotz_355_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49CC6F3B-4CA5-423A-BBCD-B06823117557",
"versionEndIncluding": "4.7.0",
"versionStartIncluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:netbotz_355:-:*:*:*:*:*:*:*",
"matchCriteriaId": "77F177F5-1863-4AF9-81A8-1044ECBD7984",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:netbotz_450_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5D19ED56-46B2-49F4-931C-15CA50D17AAA",
"versionEndIncluding": "4.7.0",
"versionStartIncluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:netbotz_450:-:*:*:*:*:*:*:*",
"matchCriteriaId": "19C9F31A-BFF1-4BE4-86C4-D3B3578152A0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:netbotz_455_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FC27E834-8A75-4F2F-A300-2990AF2796A5",
"versionEndIncluding": "4.7.0",
"versionStartIncluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:netbotz_455:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C41630CB-CE60-4979-A0F9-5F66C5C69629",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:netbotz_550_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F3A7BE2F-9AFD-4524-97DE-45855381A3D5",
"versionEndIncluding": "4.7.0",
"versionStartIncluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:netbotz_550:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C55DCA01-8401-4002-8692-F26B7A50BCA9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:netbotz_570_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "62990842-7902-4AF0-99EE-31188AACCA5A",
"versionEndIncluding": "4.7.0",
"versionStartIncluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:netbotz_570:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3307CFF4-C9A5-40D4-9B1A-B8D06839BC75",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause code and session manipulation when malicious\ncode is inserted into the browser.\n\n Affected Products: NetBotz 4 - 355/450/455/550/570\u00a0(V4.7.0\n\n and prior)"
}
],
"id": "CVE-2022-43376",
"lastModified": "2024-11-21T07:26:21.757",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 4.7,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-04-18T20:15:10.297",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "NetBotz 4 - 355/450/455/550/570",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "V4.7.0 and prior"
}
]
}
],
"source": "cybersecurity@se.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:netbotz_355_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49CC6F3B-4CA5-423A-BBCD-B06823117557",
"versionEndIncluding": "4.7.0",
"versionStartIncluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:netbotz_355:-:*:*:*:*:*:*:*",
"matchCriteriaId": "77F177F5-1863-4AF9-81A8-1044ECBD7984",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:netbotz_450_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5D19ED56-46B2-49F4-931C-15CA50D17AAA",
"versionEndIncluding": "4.7.0",
"versionStartIncluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:netbotz_450:-:*:*:*:*:*:*:*",
"matchCriteriaId": "19C9F31A-BFF1-4BE4-86C4-D3B3578152A0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:netbotz_455_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FC27E834-8A75-4F2F-A300-2990AF2796A5",
"versionEndIncluding": "4.7.0",
"versionStartIncluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:netbotz_455:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C41630CB-CE60-4979-A0F9-5F66C5C69629",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:netbotz_550_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F3A7BE2F-9AFD-4524-97DE-45855381A3D5",
"versionEndIncluding": "4.7.0",
"versionStartIncluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:netbotz_550:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C55DCA01-8401-4002-8692-F26B7A50BCA9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:netbotz_570_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "62990842-7902-4AF0-99EE-31188AACCA5A",
"versionEndIncluding": "4.7.0",
"versionStartIncluding": "4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:netbotz_570:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3307CFF4-C9A5-40D4-9B1A-B8D06839BC75",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause code and session manipulation when malicious\ncode is inserted into the browser.\n\n Affected Products: NetBotz 4 - 355/450/455/550/570\u00a0(V4.7.0\n\n and prior)"
}
],
"id": "CVE-2022-43376",
"lastModified": "2026-06-17T05:06:23.813",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 4.7,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-43376",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:50:33.636877Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-04-18T20:15:10.297",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-29T02:58:31+00:00",
"cve": "CVE-2022-43376",
"id": "CVE-2022-43376",
"initial_release_date": "2022-11-08T08:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2022-43376",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-43376.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:32:58.339Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43376",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:50:33.636877Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T19:50:35.220Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "NetBotz 4 - 355/450/455/550/570",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "V4.7.0 and prior"
}
]
}
],
"datePublic": "2022-11-08T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause code and session manipulation when malicious\ncode is inserted into the browser.\n\n Affected Products: NetBotz 4 - 355/450/455/550/570\u0026nbsp;(V4.7.0\n\n and prior)"
}
],
"value": "\n\n\nA CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\nScripting\u0027) vulnerability exists that could cause code and session manipulation when malicious\ncode is inserted into the browser.\n\n Affected Products: NetBotz 4 - 355/450/455/550/570\u00a0(V4.7.0\n\n and prior)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-18T19:55:07.347Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-312-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-312-01-NetBotz_4_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-43376",
"datePublished": "2023-04-18T19:55:07.347Z",
"dateReserved": "2022-10-17T16:42:12.652Z",
"dateUpdated": "2025-02-05T20:05:07.304Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…