Summary
A vulnerability has been identified in Solid Edge (All Versions < SE2022MP9). The affected application contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17627)
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-258115.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-258115.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | Solid Edge |
Version: All Versions < SE2022MP9 |
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T10:37:42.243Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_transferred", ], url: "https://cert-portal.siemens.com/productcert/pdf/ssa-258115.pdf", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "Solid Edge", vendor: "Siemens", versions: [ { status: "affected", version: "All Versions < SE2022MP9", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in Solid Edge (All Versions < SE2022MP9). The affected application contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17627)", }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-122", description: "CWE-122: Heap-based Buffer Overflow", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2022-10-11T00:00:00", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/pdf/ssa-258115.pdf", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2022-37864", datePublished: "2022-10-11T00:00:00", dateReserved: "2022-08-08T00:00:00", dateUpdated: "2024-08-03T10:37:42.243Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { nvd: "{\"cve\":{\"id\":\"CVE-2022-37864\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-10-11T11:15:10.233\",\"lastModified\":\"2024-11-21T07:15:17.167\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Solid Edge (All Versions < SE2022MP9). The affected application contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17627)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Solid Edge (todas las versiones anteriores a SE2022MP9). La aplicación afectada contiene una escritura fuera de límites más allá del búfer de longitud fija en la región heap de la memoria mientras analiza archivos DWG especialmente diseñados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual. (ZDI-CAN-17627)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-122\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"07440B76-B975-4946-8A97-38C564D240E4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:*\",\"matchCriteriaId\":\"5F0A748E-BB6F-4604-8024-F50DC0C20EAF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:*\",\"matchCriteriaId\":\"2F495722-39BD-4BA1-A643-C7D0BA81CC21\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:*\",\"matchCriteriaId\":\"7B776512-BF3D-4F70-BD58-AFF8E1B03EE2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:*\",\"matchCriteriaId\":\"99E05299-50FD-4292-9978-8E05C1483FE2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:*\",\"matchCriteriaId\":\"2447D05B-2634-4895-B7B0-6F7DBB9D2EC2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:*\",\"matchCriteriaId\":\"CBBD39F3-790F-4017-A57E-6EFC314F0557\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4387BFA-8A98-433E-9EF7-B29226C195A7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E380F66-C11C-472B-9B71-7CB4AF4FABDC\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-258115.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-258115.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}", }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.