GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2022-37012 (GCVE-0-2022-37012)

Vulnerability from cvelistv5 – Published: 2023-03-29 00:00 – Updated: 2025-02-18 19:34
VLAI
Summary
This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-18 19:34 UTC
CWE
  • CWE-911 - Improper Update of Reference Count
Assigner
Impacted products
Vendor Product Version CPE status
Unified Automation OPC UA C++ Demo Server Affected: 1.7.6-537
guessed Create a notification for this product.
Credits
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:21:32.458Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1030/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-37012",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T19:34:15.764429Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T19:34:23.714Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OPC UA C++ Demo Server",
          "vendor": "Unified Automation",
          "versions": [
            {
              "status": "affected",
              "version": "1.7.6-537"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "20urdjk"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-911",
              "description": "CWE-911: Improper Update of Reference Count",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-29T00:00:00.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-22-1030/"
        },
        {
          "url": "https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2022-37012",
    "datePublished": "2023-03-29T00:00:00.000Z",
    "dateReserved": "2022-07-28T00:00:00.000Z",
    "dateUpdated": "2025-02-18T19:34:23.714Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-37012",
      "date": "2026-09-16",
      "epss": "0.0178",
      "percentile": "0.77126"
    },
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:unified-automation:opc_ua_c\\\\+\\\\+_demo_server:1.7.6.537:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"389A3E3E-164D-44D8-95DF-DD21308ACA35\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927.\"}]",
      "id": "CVE-2022-37012",
      "lastModified": "2024-11-21T07:14:16.950",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV30\": [{\"source\": \"zdi-disclosures@trendmicro.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
      "published": "2023-03-29T19:15:12.827",
      "references": "[{\"url\": \"https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt\", \"source\": \"zdi-disclosures@trendmicro.com\", \"tags\": [\"Release Notes\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-22-1030/\", \"source\": \"zdi-disclosures@trendmicro.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Release Notes\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-22-1030/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}]",
      "sourceIdentifier": "zdi-disclosures@trendmicro.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"zdi-disclosures@trendmicro.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-911\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-37012\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2023-03-29T19:15:12.827\",\"lastModified\":\"2026-06-17T04:54:27.880\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927.\"}],\"affected\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"affectedData\":[{\"vendor\":\"Unified Automation\",\"product\":\"OPC UA C++ Demo Server\",\"versions\":[{\"version\":\"1.7.6-537\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2025-02-18T19:34:15.764429Z\",\"id\":\"CVE-2022-37012\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"yes\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-911\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:unified-automation:opc_ua_c\\\\+\\\\+_demo_server:1.7.6.537:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"389A3E3E-164D-44D8-95DF-DD21308ACA35\"}]}]}],\"references\":[{\"url\":\"https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt\",\"source\":\"zdi-disclosures@trendmicro.com\",\"tags\":[\"Release Notes\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-22-1030/\",\"source\":\"zdi-disclosures@trendmicro.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Release Notes\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-22-1030/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}",
    "redhat_vex": {
      "current_release_date": "2025-05-29T02:59:55+00:00",
      "cve": "CVE-2022-37012",
      "id": "CVE-2022-37012",
      "initial_release_date": "2022-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2022-37012",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-37012.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-22-1030/\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T10:21:32.458Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-37012\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-18T19:34:15.764429Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-18T19:34:12.716Z\"}}], \"cna\": {\"credits\": [{\"lang\": \"en\", \"value\": \"20urdjk\"}], \"metrics\": [{\"cvssV3_0\": {\"scope\": \"UNCHANGED\", \"version\": \"3.0\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}], \"affected\": [{\"vendor\": \"Unified Automation\", \"product\": \"OPC UA C++ Demo Server\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.7.6-537\"}]}], \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-22-1030/\"}, {\"url\": \"https://documentation.unified-automation.com/uasdkcpp/1.7.7/CHANGELOG.txt\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Unified Automation OPC UA C++ Demo Server 1.7.6-537. Authentication is not required to exploit this vulnerability. The specific flaw exists within the OpcUa_SecureListener_ProcessSessionCallRequest method. A crafted OPC UA message can force the server to incorrectly update a reference count. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-16927.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-911\", \"description\": \"CWE-911: Improper Update of Reference Count\"}]}], \"providerMetadata\": {\"orgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"shortName\": \"zdi\", \"dateUpdated\": \"2023-03-29T00:00:00.000Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-37012\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-18T19:34:23.714Z\", \"dateReserved\": \"2022-07-28T00:00:00.000Z\", \"assignerOrgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"datePublished\": \"2023-03-29T00:00:00.000Z\", \"assignerShortName\": \"zdi\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…