CVE-2022-36955 (GCVE-0-2022-36955)
Vulnerability from cvelistv5
Published
2022-07-27 20:58
Modified
2024-08-03 10:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
In Veritas NetBackup, an attacker with unprivileged local access to a NetBackup Client may send specific commands to escalate their privileges. This affects 8.0 through 8.1.2, 8.2, 8.3 through 8.3.0.2, 9.x through 9.0.0.1, and 9.1.x through 9.1.0.1.
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:21:32.411Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.veritas.com/content/support/en_US/security/VTS22-008#Issue2"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Veritas NetBackup, an attacker with unprivileged local access to a NetBackup Client may send specific commands to escalate their privileges. This affects 8.0 through 8.1.2, 8.2, 8.3 through 8.3.0.2, 9.x through 9.0.0.1, and 9.1.x through 9.1.0.1."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AC:L/AV:L/A:H/C:H/I:H/PR:N/S:U/UI:R",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-27T20:58:09",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.veritas.com/content/support/en_US/security/VTS22-008#Issue2"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-36955",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Veritas NetBackup, an attacker with unprivileged local access to a NetBackup Client may send specific commands to escalate their privileges. This affects 8.0 through 8.1.2, 8.2, 8.3 through 8.3.0.2, 9.x through 9.0.0.1, and 9.1.x through 9.1.0.1."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AC:L/AV:L/A:H/C:H/I:H/PR:N/S:U/UI:R",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.veritas.com/content/support/en_US/security/VTS22-008#Issue2",
"refsource": "MISC",
"url": "https://www.veritas.com/content/support/en_US/security/VTS22-008#Issue2"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-36955",
"datePublished": "2022-07-27T20:58:09",
"dateReserved": "2022-07-27T00:00:00",
"dateUpdated": "2024-08-03T10:21:32.411Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2022-36955\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-07-27T21:15:09.190\",\"lastModified\":\"2024-11-21T07:14:08.953\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Veritas NetBackup, an attacker with unprivileged local access to a NetBackup Client may send specific commands to escalate their privileges. This affects 8.0 through 8.1.2, 8.2, 8.3 through 8.3.0.2, 9.x through 9.0.0.1, and 9.1.x through 9.1.0.1.\"},{\"lang\":\"es\",\"value\":\"En Veritas NetBackup, un atacante con acceso local no privilegiado a un Cliente NetBackup puede enviar comandos espec\u00edficos para escalar sus privilegios. Esto afecta a versiones 8.0 hasta 8.1.2, 8.2, 8.3 hasta 8.3.0.2, 9.x hasta 9.0.0.1 y 9.1.x hasta 9.1.0.1\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.5,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:veritas:netbackup:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.0\",\"versionEndIncluding\":\"8.1.2\",\"matchCriteriaId\":\"3DC735CA-9312-4C5C-8FD1-8821A423B19E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:veritas:netbackup:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.3.0.0\",\"versionEndIncluding\":\"8.3.0.2\",\"matchCriteriaId\":\"3564F63C-D9E3-429A-BCBA-2F29FBEB3C3F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:veritas:netbackup:8.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3678D77D-D641-47C6-92BA-FE124D645F47\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:veritas:netbackup:9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E3A9DC13-0464-4507-A5A2-91BEF7E55AA1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:veritas:netbackup:9.1.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1F3A7C9B-44E3-4DEF-B0CE-DC2F00564F61\"}]}]}],\"references\":[{\"url\":\"https://www.veritas.com/content/support/en_US/security/VTS22-008#Issue2\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.veritas.com/content/support/en_US/security/VTS22-008#Issue2\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…