CVE-2022-32985 (GCVE-0-2022-32985)

Vulnerability from cvelistv5 – Published: 2022-07-17 22:48 – Updated: 2024-08-03 07:54
VLAI?
Summary
libnx_apl.so on Nexans FTTO GigaSwitch before 6.02N and 7.x before 7.02 implements a Backdoor Account for SSH logins on port 50200 or 50201.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:54:03.446Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.nexans.de/de/products/Data-Network-Solutions/Industrial-and-office-switches.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://sec-consult.com/vulnerability-lab/advisory/hardcoded-backdoor-user-outdated-software-components-nexans-ftto-gigaswitch/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "libnx_apl.so on Nexans FTTO GigaSwitch before 6.02N and 7.x before 7.02 implements a Backdoor Account for SSH logins on port 50200 or 50201."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-17T22:48:58.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.nexans.de/de/products/Data-Network-Solutions/Industrial-and-office-switches.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://sec-consult.com/vulnerability-lab/advisory/hardcoded-backdoor-user-outdated-software-components-nexans-ftto-gigaswitch/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-32985",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "libnx_apl.so on Nexans FTTO GigaSwitch before 6.02N and 7.x before 7.02 implements a Backdoor Account for SSH logins on port 50200 or 50201."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.nexans.de/de/products/Data-Network-Solutions/Industrial-and-office-switches.html",
              "refsource": "MISC",
              "url": "https://www.nexans.de/de/products/Data-Network-Solutions/Industrial-and-office-switches.html"
            },
            {
              "name": "https://sec-consult.com/vulnerability-lab/advisory/hardcoded-backdoor-user-outdated-software-components-nexans-ftto-gigaswitch/",
              "refsource": "MISC",
              "url": "https://sec-consult.com/vulnerability-lab/advisory/hardcoded-backdoor-user-outdated-software-components-nexans-ftto-gigaswitch/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-32985",
    "datePublished": "2022-07-17T22:48:58.000Z",
    "dateReserved": "2022-06-10T00:00:00.000Z",
    "dateUpdated": "2024-08-03T07:54:03.446Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-32985",
      "date": "2026-05-08",
      "epss": "0.00614",
      "percentile": "0.69975"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_641_desk_v5_sfp-vi_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"F130901E-4D8F-4036-BB59-78A5A09A4B38\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_641_desk_v5_sfp-vi_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"5FBE97B6-6B70-4F20-B4E2-984872B9851F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_641_desk_v5_sfp-vi:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"01E53A0B-FDEF-4AB5-AFC8-E32F5FDF7E1A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_642_desk_v5_sfp-2vi_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"DCAB8644-7C58-4447-B9CF-F89114CF09FF\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_642_desk_v5_sfp-2vi_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"E6D07D42-0290-437F-AC78-B601B793DE42\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_642_desk_v5_sfp-2vi:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6AE029D9-A834-4F8E-9D31-2995CD662A30\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_2tp\\\\(pd-f\\\\+\\\\)_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"FD36F20F-657B-40B9-A0BE-BC618925DD03\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_2tp\\\\(pd-f\\\\+\\\\)_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"1B4FEBD1-5DF2-4A41-97DB-6D1BDF7F6C7B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_v5_2tp\\\\(pd-f\\\\+\\\\)_sfp-vi_54vdc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"26DC7E05-780F-4619-B9CA-791F8A800CB5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_2tp\\\\(pse\\\\+\\\\)_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"3A06836D-0277-42FB-89A7-F447A8965949\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_2tp\\\\(pse\\\\+\\\\)_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"3E9D8E02-2F9B-4162-AA10-5DDF737E2917\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_v5_2tp\\\\(pse\\\\+\\\\)_sfp-vi_54vdc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2EC7A7E6-8372-4524-A670-D25F72DC2136\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_2tp_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"FA8E1089-06DF-4037-A64A-62605B85BAAB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_2tp_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"8307E535-1C06-4F95-B5C0-E05607EC40CB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_v5_2tp_sfp-vi_54vdc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D2505199-CA23-4240-AB85-61A871D61A57\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_sfp-2vi_230vac_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"254E133B-73D6-44F5-80FF-42292F0DC2E2\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_sfp-2vi_230vac_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"07DC03AC-D4AC-472D-9AFB-6EB88762FC5A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_v5_sfp-2vi_230vac:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1597D8F8-7997-4CFE-AA01-F973894745C6\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"378B152F-C30A-4CE2-927E-B6568BB319C7\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"A7ED3A23-42FF-46E7-86A5-449E86126F2D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DBDD9F34-59FB-48B1-A7AB-CA4149BFF294\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_ind_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"399951C7-0507-4A6A-93BB-E395B30C20F9\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_ind_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"AC63EDA8-7F04-4BB1-B697-7393F7A95BCC\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_ind:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A366AC40-7F7C-473D-9CC2-CED9768BDA3D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_med_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"2EA2A765-1CE5-4C18-A32F-B02FDCBAF93B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_med_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"3E813952-F099-46D3-B042-5C3099745EF4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_med:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"23ED5429-62BF-442D-A99A-B98EA8AFF063\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"B490CF52-7C24-4D21-9451-AB85C3BEC82B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"03163410-20A5-45CB-BBF4-D7ED19AB452F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"33EB6A88-9015-4F2D-A820-E982016B3F9F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_ind_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"4CD0607F-8124-4478-A550-6E19C8CA2948\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_ind_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"4B00F440-6229-4C48-89FA-F32CCEB16877\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_ind:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"59BFE60D-A94C-4C86-9D60-FED3694CCE1B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_med_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"3B6720C6-3BFA-4990-B285-F3B56C452274\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_med_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"1795910D-46E2-44E9-AA4A-4C5F8B85079A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_med:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1A723AEC-BD82-437D-B35E-E15F440A56E6\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-vi_230vac_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.02n\", \"matchCriteriaId\": \"EBE47298-6058-4086-BD59-B5AC3115029D\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-vi_230vac_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0\", \"versionEndExcluding\": \"7.02\", \"matchCriteriaId\": \"F7B4CA67-58AB-4B69-A80C-4C828D0D8D4D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nexans:gigaswitch_v5_tp_sfp-vi_230vac:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"98ACC6A5-5030-40DA-8D0E-C0AFF94D3748\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"libnx_apl.so on Nexans FTTO GigaSwitch before 6.02N and 7.x before 7.02 implements a Backdoor Account for SSH logins on port 50200 or 50201.\"}, {\"lang\": \"es\", \"value\": \"El archivo libnx_apl.so en Nexans FTTO GigaSwitch versiones anteriores a 6.02N y versiones 7.x anteriores a 7.02, implementa una cuenta de puerta trasera para los inicios de sesi\\u00f3n SSH en el puerto 50200 o 50201\"}]",
      "id": "CVE-2022-32985",
      "lastModified": "2024-11-21T07:07:21.563",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
      "published": "2022-07-17T23:15:09.060",
      "references": "[{\"url\": \"https://sec-consult.com/vulnerability-lab/advisory/hardcoded-backdoor-user-outdated-software-components-nexans-ftto-gigaswitch/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://www.nexans.de/de/products/Data-Network-Solutions/Industrial-and-office-switches.html\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://sec-consult.com/vulnerability-lab/advisory/hardcoded-backdoor-user-outdated-software-components-nexans-ftto-gigaswitch/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://www.nexans.de/de/products/Data-Network-Solutions/Industrial-and-office-switches.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-798\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-32985\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-07-17T23:15:09.060\",\"lastModified\":\"2024-11-21T07:07:21.563\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"libnx_apl.so on Nexans FTTO GigaSwitch before 6.02N and 7.x before 7.02 implements a Backdoor Account for SSH logins on port 50200 or 50201.\"},{\"lang\":\"es\",\"value\":\"El archivo libnx_apl.so en Nexans FTTO GigaSwitch versiones anteriores a 6.02N y versiones 7.x anteriores a 7.02, implementa una cuenta de puerta trasera para los inicios de sesi\u00f3n SSH en el puerto 50200 o 50201\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_641_desk_v5_sfp-vi_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"F130901E-4D8F-4036-BB59-78A5A09A4B38\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_641_desk_v5_sfp-vi_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"5FBE97B6-6B70-4F20-B4E2-984872B9851F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_641_desk_v5_sfp-vi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"01E53A0B-FDEF-4AB5-AFC8-E32F5FDF7E1A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_642_desk_v5_sfp-2vi_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"DCAB8644-7C58-4447-B9CF-F89114CF09FF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_642_desk_v5_sfp-2vi_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"E6D07D42-0290-437F-AC78-B601B793DE42\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_642_desk_v5_sfp-2vi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6AE029D9-A834-4F8E-9D31-2995CD662A30\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_2tp\\\\(pd-f\\\\+\\\\)_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"FD36F20F-657B-40B9-A0BE-BC618925DD03\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_2tp\\\\(pd-f\\\\+\\\\)_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"1B4FEBD1-5DF2-4A41-97DB-6D1BDF7F6C7B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_v5_2tp\\\\(pd-f\\\\+\\\\)_sfp-vi_54vdc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"26DC7E05-780F-4619-B9CA-791F8A800CB5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_2tp\\\\(pse\\\\+\\\\)_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"3A06836D-0277-42FB-89A7-F447A8965949\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_2tp\\\\(pse\\\\+\\\\)_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"3E9D8E02-2F9B-4162-AA10-5DDF737E2917\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_v5_2tp\\\\(pse\\\\+\\\\)_sfp-vi_54vdc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2EC7A7E6-8372-4524-A670-D25F72DC2136\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_2tp_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"FA8E1089-06DF-4037-A64A-62605B85BAAB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_2tp_sfp-vi_54vdc_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"8307E535-1C06-4F95-B5C0-E05607EC40CB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_v5_2tp_sfp-vi_54vdc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2505199-CA23-4240-AB85-61A871D61A57\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_sfp-2vi_230vac_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"254E133B-73D6-44F5-80FF-42292F0DC2E2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_sfp-2vi_230vac_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"07DC03AC-D4AC-472D-9AFB-6EB88762FC5A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_v5_sfp-2vi_230vac:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1597D8F8-7997-4CFE-AA01-F973894745C6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"378B152F-C30A-4CE2-927E-B6568BB319C7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"A7ED3A23-42FF-46E7-86A5-449E86126F2D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DBDD9F34-59FB-48B1-A7AB-CA4149BFF294\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_ind_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"399951C7-0507-4A6A-93BB-E395B30C20F9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_ind_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"AC63EDA8-7F04-4BB1-B697-7393F7A95BCC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_ind:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A366AC40-7F7C-473D-9CC2-CED9768BDA3D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_med_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"2EA2A765-1CE5-4C18-A32F-B02FDCBAF93B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_med_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"3E813952-F099-46D3-B042-5C3099745EF4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_v5_tp\\\\(pse\\\\+\\\\)_sfp-2vi_54vdc_med:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"23ED5429-62BF-442D-A99A-B98EA8AFF063\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"B490CF52-7C24-4D21-9451-AB85C3BEC82B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"03163410-20A5-45CB-BBF4-D7ED19AB452F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33EB6A88-9015-4F2D-A820-E982016B3F9F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_ind_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"4CD0607F-8124-4478-A550-6E19C8CA2948\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_ind_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"4B00F440-6229-4C48-89FA-F32CCEB16877\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_ind:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"59BFE60D-A94C-4C86-9D60-FED3694CCE1B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_med_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"3B6720C6-3BFA-4990-B285-F3B56C452274\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_med_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"1795910D-46E2-44E9-AA4A-4C5F8B85079A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_v5_tp_sfp-2vi_54vdc_med:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1A723AEC-BD82-437D-B35E-E15F440A56E6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-vi_230vac_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.02n\",\"matchCriteriaId\":\"EBE47298-6058-4086-BD59-B5AC3115029D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nexans:gigaswitch_v5_tp_sfp-vi_230vac_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndExcluding\":\"7.02\",\"matchCriteriaId\":\"F7B4CA67-58AB-4B69-A80C-4C828D0D8D4D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nexans:gigaswitch_v5_tp_sfp-vi_230vac:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"98ACC6A5-5030-40DA-8D0E-C0AFF94D3748\"}]}]}],\"references\":[{\"url\":\"https://sec-consult.com/vulnerability-lab/advisory/hardcoded-backdoor-user-outdated-software-components-nexans-ftto-gigaswitch/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.nexans.de/de/products/Data-Network-Solutions/Industrial-and-office-switches.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://sec-consult.com/vulnerability-lab/advisory/hardcoded-backdoor-user-outdated-software-components-nexans-ftto-gigaswitch/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.nexans.de/de/products/Data-Network-Solutions/Industrial-and-office-switches.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…