Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-29801 (GCVE-0-2022-29801)
Vulnerability from cvelistv5
- CWE-611 - Improper Restriction of XML External Entity Reference
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Teamcenter V12.4 |
Version: All versions < V12.4.0.13 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T06:33:42.535Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Teamcenter V12.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V12.4.0.13"
}
]
},
{
"product": "Teamcenter V13.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.0.0.9"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611: Improper Restriction of XML External Entity Reference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:17:39",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-29801",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Teamcenter V12.4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V12.4.0.13"
}
]
}
},
{
"product_name": "Teamcenter V13.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.0.0.9"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-611: Improper Restriction of XML External Entity Reference"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-29801",
"datePublished": "2022-05-10T09:47:13",
"dateReserved": "2022-04-25T00:00:00",
"dateUpdated": "2024-08-03T06:33:42.535Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2022-29801\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-05-20T13:15:15.877\",\"lastModified\":\"2024-11-21T06:59:42.700\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Teamcenter V12.4 (Todas las versiones anteriores a V12.4.0.13), Teamcenter V13.0 (Todas las versiones anteriores a V13.0.0.9). La aplicaci\u00f3n contiene una vulnerabilidad de inyecci\u00f3n de entidades externas XML (XXE). Esto podr\u00eda permitir a un atacante ver archivos en el sistema de archivos del servidor de aplicaciones\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-611\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-611\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.4.0.13\",\"matchCriteriaId\":\"955EB695-37D8-40DB-9867-B2007B9EA53D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.0\",\"versionEndExcluding\":\"13.0.0.9\",\"matchCriteriaId\":\"C0EDF96B-DF5B-4A9E-A70E-FD3EEE8067CD\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
CERTFR-2022-AVI-435
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
- SICAM P850 versions antérieures à 3.00
- Simcenter Femap versions antérieures à 2022.2
- SIMATIC NET PC Software versions 14.x antérieures à 14 SP1 Update 14
- SIMATIC NET PC Software versions 17.x antérieures à 17 SP1
- SIMATIC Process Historian OPC UA Server versions antérieures à 2020 SP1
- SIMATIC WinCC versions 7.5.x antérieures à V7.5 SP2 Update 8
- SIMATIC CP 442-1 RNA versions antérieures à 1.5.18
- SIMATIC CP 443-1 RNA versions antérieures à 1.5.18
- JT2Go versions antérieures à 13.3.0.3
- Teamcenter Visualization versions 13.3.x antérieures à 13.3.0.3
- Teamcenter Visualization versions 14.0.x antérieures à 14.0.0.1
- Desigo DXR2 versions antérieures à 01.21.142.5-22
- Desigo PXC3 versions antérieures à 01.21.142.4-18
- Desigo PXC4 versions antérieures à 02.20.142.10-10884
- Desigo PXC5 versions antérieures à 02.20.142.10-10884
- RUGGEDCOM RM1224 LTE(4G) EU et RM1224 LTE(4G) NAM versions antérieures à 7.1
- SCALANCE M804PB, M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2), M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2), M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2), M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2), M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), M874-2 (6GK5874-2AA00-2AA2), M874-3 (6GK5874-3AA00-2AA2), M876-3 (EVDO) (6GK5876-3AA02-2BA2), M876-3 (ROK) (6GK5876-3AA02-2EA2), M876-4 (EU) (6GK5876-4AA00-2BA2), M876-4 (NAM) (6GK5876-4AA00-2DA2), MUM856-1 (EU) (6GK5856-2EA00-3DA1), MUM856-1 (RoW) (6GK5856-2EA00-3AA1) et S615 (6GK5615-0AA00-2AA2) versions antérieures à 7.1
- SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) versions antérieures à 3.0.22
- SIMATIC RTU3010C (6NH3112-0BA00-0XX0), RTU3030C (6NH3112-3BA00-0XX0), RTU3031C (6NH3112-3BB00-0XX0) et RTU3041C (6NH3112-4BB00-0XX0) versions antérieures à 5.0.14
- SIPLUS NET CP 1543-1 versions antérieures à 3.0.22
- OpenV2G versions antérieures à 0.9.5
- Teamcenter versions 12.4.x antérieures à 12.4.0.13
- Teamcenter versions 13.0.x antérieures à 13.0.0.9
- Teamcenter versions 13.2.x antérieures à 13.2.0.8
- Teamcenter versions 13.3.x antérieures à 13.3.0.3
- SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0), RF610R ETSI (6GT2811-6BC10-0AA0), RF610R FCC (6GT2811-6BC10-1AA0), RF615R CMIIT (6GT2811-6CC10-2AA0), RF615R ETSI (6GT2811-6CC10-0AA0), RF615R FCC (6GT2811-6CC10-1AA0), RF650R ARIB (6GT2811-6AB20-4AA0), RF650R CMIIT (6GT2811-6AB20-2AA0), RF650R ETSI (6GT2811-6AB20-0AA0), RF650R FCC (6GT2811-6AB20-1AA0), RF680R ARIB (6GT2811-6AA10-4AA0), RF680R CMIIT (6GT2811-6AA10-2AA0), RF680R ETSI (6GT2811-6AA10-0AA0), RF680R FCC (6GT2811-6AA10-1AA0), RF685R ARIB (6GT2811-6CA10-4AA0), RF685R CMIIT (6GT2811-6CA10-2AA0), RF685R ETSI (6GT2811-6CA10-0AA0) et RF685R FCC (6GT2811-6CA10-1AA0) versions 3.0.x antérieures à 4.0
- SIMATIC RF166C (6GT2002-0EE20), RF185C (6GT2002-0JE10), RF186C (6GT2002-0JE20), RF186CI (6GT2002-0JE50), RF188C (6GT2002-0JE40) et RF188CI (6GT2002-0JE60) versions 1.1.x antérieures à 1.3.2
- SIMATIC RF360R (6GT2801-5BA30) versions antérieures à 2.0
En fonction de la vulnérabilité, l'éditeur ne prévoit pas de correctif de sécurité pour les produits suivants :
- SITOP Manager toutes versions
- TeleControl Server Basic versions 3.x
- SIMATIC NET PC Software versions 15.x
- SIMATIC NET PC Software versions 16.x
- SIMATIC WinCC versions 16.x
- SIMATIC WinCC versions 17.x
- SIMATIC WinCC Runtime Professional toutes versions
- SIMATIC WinCC Unified Scada Runtime toutes versions
- SIMATIC PCS 7 versions 9.0.x et antérieures
- SIMATIC PCS 7 versions 9.1.x
- LOGO! CMR family toutes versions
- SIMATIC CP 1545-1 (6GK7545-1GX00-0XE0) toutes versions
- Teamcenter versions 13.1.x
- Teamcenter versions 14.0.x
Se référer aux mesures de contournement listées dans les avis de l'éditeur.
| Vendor | Product | Description |
|---|
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cul\u003e \u003cli\u003eSICAM P850 versions ant\u00e9rieures \u00e0 3.00\u003c/li\u003e \u003cli\u003eSimcenter Femap versions ant\u00e9rieures \u00e0 2022.2\u003c/li\u003e \u003cli\u003eSIMATIC NET PC Software versions 14.x ant\u00e9rieures \u00e0 14 SP1 Update 14\u003c/li\u003e \u003cli\u003eSIMATIC NET PC Software versions 17.x ant\u00e9rieures \u00e0 17 SP1\u003c/li\u003e \u003cli\u003eSIMATIC Process Historian OPC UA Server versions ant\u00e9rieures \u00e0 2020 SP1\u003c/li\u003e \u003cli\u003eSIMATIC WinCC versions 7.5.x ant\u00e9rieures \u00e0 V7.5 SP2 Update 8\u003c/li\u003e \u003cli\u003eSIMATIC CP 442-1 RNA versions ant\u00e9rieures \u00e0 1.5.18\u003c/li\u003e \u003cli\u003eSIMATIC CP 443-1 RNA versions ant\u00e9rieures \u00e0 1.5.18\u003c/li\u003e \u003cli\u003eJT2Go versions ant\u00e9rieures \u00e0 13.3.0.3\u003c/li\u003e \u003cli\u003eTeamcenter Visualization versions 13.3.x ant\u00e9rieures \u00e0 13.3.0.3\u003c/li\u003e \u003cli\u003eTeamcenter Visualization versions 14.0.x ant\u00e9rieures \u00e0 14.0.0.1\u003c/li\u003e \u003cli\u003eDesigo DXR2 versions ant\u00e9rieures \u00e0 01.21.142.5-22\u003c/li\u003e \u003cli\u003eDesigo PXC3 versions ant\u00e9rieures \u00e0 01.21.142.4-18\u003c/li\u003e \u003cli\u003eDesigo PXC4 versions ant\u00e9rieures \u00e0 02.20.142.10-10884\u003c/li\u003e \u003cli\u003eDesigo PXC5 versions ant\u00e9rieures \u00e0 02.20.142.10-10884\u003c/li\u003e \u003cli\u003eRUGGEDCOM RM1224 LTE(4G) EU et RM1224 LTE(4G) NAM versions ant\u00e9rieures \u00e0 7.1\u003c/li\u003e \u003cli\u003eSCALANCE M804PB, M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2), M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2), M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2), M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2), M826-2 SHDSL-Router (6GK5826-2AB00-2AB2), M874-2 (6GK5874-2AA00-2AA2), M874-3 (6GK5874-3AA00-2AA2), M876-3 (EVDO) (6GK5876-3AA02-2BA2), M876-3 (ROK) (6GK5876-3AA02-2EA2), M876-4 (EU) (6GK5876-4AA00-2BA2), M876-4 (NAM) (6GK5876-4AA00-2DA2), MUM856-1 (EU) (6GK5856-2EA00-3DA1), MUM856-1 (RoW) (6GK5856-2EA00-3AA1) et S615 (6GK5615-0AA00-2AA2) versions ant\u00e9rieures \u00e0 7.1\u003c/li\u003e \u003cli\u003eSIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) versions ant\u00e9rieures \u00e0 3.0.22\u003c/li\u003e \u003cli\u003eSIMATIC RTU3010C (6NH3112-0BA00-0XX0), RTU3030C (6NH3112-3BA00-0XX0), RTU3031C (6NH3112-3BB00-0XX0) et RTU3041C (6NH3112-4BB00-0XX0) versions ant\u00e9rieures \u00e0 5.0.14\u003c/li\u003e \u003cli\u003eSIPLUS NET CP 1543-1 versions ant\u00e9rieures \u00e0 3.0.22\u003c/li\u003e \u003cli\u003eOpenV2G versions ant\u00e9rieures \u00e0 0.9.5\u003c/li\u003e \u003cli\u003eTeamcenter versions 12.4.x ant\u00e9rieures \u00e0 12.4.0.13\u003c/li\u003e \u003cli\u003eTeamcenter versions 13.0.x ant\u00e9rieures \u00e0 13.0.0.9\u003c/li\u003e \u003cli\u003eTeamcenter versions 13.2.x ant\u00e9rieures \u00e0 13.2.0.8\u003c/li\u003e \u003cli\u003eTeamcenter versions 13.3.x ant\u00e9rieures \u00e0 13.3.0.3\u003c/li\u003e \u003cli\u003eSIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0), RF610R ETSI (6GT2811-6BC10-0AA0), RF610R FCC (6GT2811-6BC10-1AA0), RF615R CMIIT (6GT2811-6CC10-2AA0), RF615R ETSI (6GT2811-6CC10-0AA0), RF615R FCC (6GT2811-6CC10-1AA0), RF650R ARIB (6GT2811-6AB20-4AA0), RF650R CMIIT (6GT2811-6AB20-2AA0), RF650R ETSI (6GT2811-6AB20-0AA0), RF650R FCC (6GT2811-6AB20-1AA0), RF680R ARIB (6GT2811-6AA10-4AA0), RF680R CMIIT (6GT2811-6AA10-2AA0), RF680R ETSI (6GT2811-6AA10-0AA0), RF680R FCC (6GT2811-6AA10-1AA0), RF685R ARIB (6GT2811-6CA10-4AA0), RF685R CMIIT (6GT2811-6CA10-2AA0), RF685R ETSI (6GT2811-6CA10-0AA0) et RF685R FCC (6GT2811-6CA10-1AA0) versions 3.0.x ant\u00e9rieures \u00e0 4.0\u003c/li\u003e \u003cli\u003eSIMATIC RF166C (6GT2002-0EE20), RF185C (6GT2002-0JE10), RF186C (6GT2002-0JE20), RF186CI (6GT2002-0JE50), RF188C (6GT2002-0JE40) et RF188CI (6GT2002-0JE60) versions 1.1.x ant\u00e9rieures \u00e0 1.3.2\u003c/li\u003e \u003cli\u003eSIMATIC RF360R (6GT2801-5BA30) versions ant\u00e9rieures \u00e0 2.0\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eEn fonction de la vuln\u00e9rabilit\u00e9, l\u0027\u00e9diteur ne pr\u00e9voit pas de correctif de s\u00e9curit\u00e9 pour les produits suivants :\u003c/p\u003e \u003cul\u003e \u003cli\u003eSITOP Manager toutes versions\u003c/li\u003e \u003cli\u003eTeleControl Server Basic versions 3.x\u003c/li\u003e \u003cli\u003eSIMATIC NET PC Software versions 15.x\u003c/li\u003e \u003cli\u003eSIMATIC NET PC Software versions 16.x\u003c/li\u003e \u003cli\u003eSIMATIC WinCC versions 16.x\u003c/li\u003e \u003cli\u003eSIMATIC WinCC versions 17.x\u003c/li\u003e \u003cli\u003eSIMATIC WinCC Runtime Professional toutes versions\u003c/li\u003e \u003cli\u003eSIMATIC WinCC Unified Scada Runtime toutes versions\u003c/li\u003e \u003cli\u003eSIMATIC PCS 7 versions 9.0.x et ant\u00e9rieures\u003c/li\u003e \u003cli\u003eSIMATIC PCS 7 versions 9.1.x\u003c/li\u003e \u003cli\u003eLOGO! CMR family toutes versions\u003c/li\u003e \u003cli\u003eSIMATIC CP 1545-1 (6GK7545-1GX00-0XE0) toutes versions\u003c/li\u003e \u003cli\u003eTeamcenter versions 13.1.x\u003c/li\u003e \u003cli\u003eTeamcenter versions 14.0.x\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eSe r\u00e9f\u00e9rer aux mesures de contournement list\u00e9es dans les avis de l\u0027\u00e9diteur.\u003c/p\u003e ",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-27653",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27653"
},
{
"name": "CVE-2022-24043",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24043"
},
{
"name": "CVE-2022-29879",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29879"
},
{
"name": "CVE-2022-24044",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24044"
},
{
"name": "CVE-2022-24041",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24041"
},
{
"name": "CVE-2022-27242",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27242"
},
{
"name": "CVE-2021-22901",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22901"
},
{
"name": "CVE-2022-24290",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24290"
},
{
"name": "CVE-2022-29880",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29880"
},
{
"name": "CVE-2022-24045",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24045"
},
{
"name": "CVE-2022-29882",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29882"
},
{
"name": "CVE-2022-24039",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24039"
},
{
"name": "CVE-2022-24042",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24042"
},
{
"name": "CVE-2021-22924",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22924"
},
{
"name": "CVE-2022-29033",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29033"
},
{
"name": "CVE-2022-24040",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24040"
},
{
"name": "CVE-2022-24287",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24287"
},
{
"name": "CVE-2021-41545",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41545"
},
{
"name": "CVE-2022-29873",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29873"
},
{
"name": "CVE-2022-29801",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29801"
},
{
"name": "CVE-2021-40142",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40142"
},
{
"name": "CVE-2022-29874",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29874"
},
{
"name": "CVE-2022-27640",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27640"
},
{
"name": "CVE-2022-29876",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29876"
},
{
"name": "CVE-2022-29877",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29877"
},
{
"name": "CVE-2021-45117",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-45117"
},
{
"name": "CVE-2022-29029",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29029"
},
{
"name": "CVE-2022-29881",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29881"
},
{
"name": "CVE-2022-29032",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29032"
},
{
"name": "CVE-2022-29872",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29872"
},
{
"name": "CVE-2022-29878",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29878"
},
{
"name": "CVE-2021-31340",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31340"
},
{
"name": "CVE-2022-29031",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29031"
},
{
"name": "CVE-2022-29030",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29030"
},
{
"name": "CVE-2022-29028",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29028"
},
{
"name": "CVE-2022-29883",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29883"
}
],
"initial_release_date": "2022-05-10T00:00:00",
"last_revision_date": "2022-05-10T00:00:00",
"links": [],
"reference": "CERTFR-2022-AVI-435",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-05-10T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-736385 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-736385.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-732250 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-732250.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-321292 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-321292.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-787292 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-787292.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-162616 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-162616.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-553086 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-553086.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-480937 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-480937.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-626968 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-626968.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-363107 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-363107.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-789162 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-789162.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-165073 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-165073.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-662649 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-662649.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-285795 du 10 mai 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-285795.html"
}
]
}
gsd-2022-29801
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2022-29801",
"description": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.",
"id": "GSD-2022-29801"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-29801"
],
"details": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.",
"id": "GSD-2022-29801",
"modified": "2023-12-13T01:19:41.783157Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-29801",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Teamcenter V12.4",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V12.4.0.13"
}
]
}
},
{
"product_name": "Teamcenter V13.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.0.0.9"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-611: Improper Restriction of XML External Entity Reference"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "12.4.0.13",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "13.0.0.9",
"versionStartIncluding": "13.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-29801"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-611"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2023-02-23T18:00Z",
"publishedDate": "2022-05-20T13:15Z"
}
}
}
ghsa-h2jw-98ww-486c
Vulnerability from github
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.
{
"affected": [],
"aliases": [
"CVE-2022-29801"
],
"database_specific": {
"cwe_ids": [
"CWE-611"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-05-20T13:15:00Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.",
"id": "GHSA-h2jw-98ww-486c",
"modified": "2022-05-27T00:00:24Z",
"published": "2022-05-21T00:00:56Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-29801"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"type": "CVSS_V3"
}
]
}
cnvd-2022-37370
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/html/ssa-789162.html
| Name | ['Siemens Teamcenter < V12.4.0.13', 'Siemens Teamcenter < V13.0.0.9'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2022-29801"
}
},
"description": "Siemens Teamcenter\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u5957\u4ea7\u54c1\u751f\u547d\u5468\u671f\u7ba1\u7406\u8ba1\u7b97\u673a\u8f6f\u4ef6\u5e94\u7528\u7a0b\u5e8f\u3002\n\nSiemens Teamcenter\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u67e5\u770b\u5e94\u7528\u670d\u52a1\u5668\u6587\u4ef6\u7cfb\u7edf\u4e0a\u7684\u6587\u4ef6\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-789162.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2022-37370",
"openTime": "2022-05-16",
"patchDescription": "Siemens Teamcenter\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u5957\u4ea7\u54c1\u751f\u547d\u5468\u671f\u7ba1\u7406\u8ba1\u7b97\u673a\u8f6f\u4ef6\u5e94\u7528\u7a0b\u5e8f\u3002\r\n\r\nSiemens Teamcenter\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u67e5\u770b\u5e94\u7528\u670d\u52a1\u5668\u6587\u4ef6\u7cfb\u7edf\u4e0a\u7684\u6587\u4ef6\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens Teamcenter XML\u5916\u90e8\u5b9e\u4f53\u6ce8\u5165\uff08XXE\uff09\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Siemens Teamcenter \u003c V12.4.0.13",
"Siemens Teamcenter \u003c V13.0.0.9"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-789162.html",
"serverity": "\u4e2d",
"submitTime": "2022-05-11",
"title": "Siemens Teamcenter XML\u5916\u90e8\u5b9e\u4f53\u6ce8\u5165\uff08XXE\uff09\u6f0f\u6d1e"
}
icsa-22-132-16
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
},
{
"names": [
"Han Lee"
],
"organization": "Apple Information Security",
"summary": "reporting the vulnerabilities"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Teamcenter is affected by XML External Entity Injection (XXE,\nCVE-2022-29801) and a stack based buffer overflow vulnerability\n(CVE-2022-24290). XXE impacts only Teamcenter versions before V13.1.\nSiemens has released updates for the affected products and recommends\nto update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-789162.json"
},
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-789162.txt"
},
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-132-16 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-132-16.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-132-16 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-132-16"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Teamcenter",
"tracking": {
"current_release_date": "2022-08-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-22-132-16",
"initial_release_date": "2022-05-10T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-05-10T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2022-06-14T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for Teamcenter version line V13.1"
},
{
"date": "2022-08-09T00:00:00.000000Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added fix for Teamcenter version line V14.0"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV12.4.0.13",
"product": {
"name": "Teamcenter V12.4",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Teamcenter V12.4"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.0.0.9",
"product": {
"name": "Teamcenter V13.0",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Teamcenter V13.1",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.2.0.8",
"product": {
"name": "Teamcenter V13.2",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.3.0.3",
"product": {
"name": "Teamcenter V13.3",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV14.0.0.2",
"product": {
"name": "Teamcenter V14.0",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "Teamcenter V14.0"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-24290",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.13 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.0.0.9 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.0.9 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.8 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.3.0.3 or later version",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V14.0.0.2 or later version",
"product_ids": [
"CSAFPID-0006"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-24290"
},
{
"cve": "CVE-2022-29801",
"cwe": {
"id": "CWE-611",
"name": "Improper Restriction of XML External Entity Reference"
},
"notes": [
{
"category": "summary",
"text": "The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an\r\nattacker to view files on the application server filesystem.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.13 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.0.0.9 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2022-29801"
}
]
}
ICSA-22-132-16
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
},
{
"names": [
"Han Lee"
],
"organization": "Apple Information Security",
"summary": "reporting the vulnerabilities"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Teamcenter is affected by XML External Entity Injection (XXE,\nCVE-2022-29801) and a stack based buffer overflow vulnerability\n(CVE-2022-24290). XXE impacts only Teamcenter versions before V13.1.\nSiemens has released updates for the affected products and recommends\nto update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-789162.json"
},
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-789162.txt"
},
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-132-16 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-132-16.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-132-16 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-132-16"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Teamcenter",
"tracking": {
"current_release_date": "2022-08-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-22-132-16",
"initial_release_date": "2022-05-10T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-05-10T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2022-06-14T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for Teamcenter version line V13.1"
},
{
"date": "2022-08-09T00:00:00.000000Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added fix for Teamcenter version line V14.0"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV12.4.0.13",
"product": {
"name": "Teamcenter V12.4",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Teamcenter V12.4"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.0.0.9",
"product": {
"name": "Teamcenter V13.0",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Teamcenter V13.1",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.2.0.8",
"product": {
"name": "Teamcenter V13.2",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.3.0.3",
"product": {
"name": "Teamcenter V13.3",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV14.0.0.2",
"product": {
"name": "Teamcenter V14.0",
"product_id": "CSAFPID-0006"
}
}
],
"category": "product_name",
"name": "Teamcenter V14.0"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-24290",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.13 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.0.0.9 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.0.9 or later version",
"product_ids": [
"CSAFPID-0003"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.8 or later version",
"product_ids": [
"CSAFPID-0004"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.3.0.3 or later version",
"product_ids": [
"CSAFPID-0005"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V14.0.0.2 or later version",
"product_ids": [
"CSAFPID-0006"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006"
]
}
],
"title": "CVE-2022-24290"
},
{
"cve": "CVE-2022-29801",
"cwe": {
"id": "CWE-611",
"name": "Improper Restriction of XML External Entity Reference"
},
"notes": [
{
"category": "summary",
"text": "The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an\r\nattacker to view files on the application server filesystem.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.13 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.0.0.9 or later version",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2022-29801"
}
]
}
ssa-789162
Vulnerability from csaf_siemens
Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Teamcenter is affected by XML External Entity Injection (XXE,\nCVE-2022-29801) and a stack based buffer overflow vulnerability\n(CVE-2022-24290). XXE impacts only Teamcenter versions before V13.1.\nSiemens has released updates for the affected products and recommends\nto update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
},
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-789162.txt"
},
{
"category": "self",
"summary": "SSA-789162: Vulnerabilities in Teamcenter - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-789162.json"
}
],
"title": "SSA-789162: Vulnerabilities in Teamcenter",
"tracking": {
"current_release_date": "2022-08-09T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-789162",
"initial_release_date": "2022-05-10T00:00:00Z",
"revision_history": [
{
"date": "2022-05-10T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2022-06-14T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for Teamcenter version line V13.1"
},
{
"date": "2022-08-09T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added fix for Teamcenter version line V14.0"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V12.4.0.13",
"product": {
"name": "Teamcenter V12.4",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Teamcenter V12.4"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.0.0.9",
"product": {
"name": "Teamcenter V13.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Teamcenter V13.1",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.2.0.8",
"product": {
"name": "Teamcenter V13.2",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13.3.0.3",
"product": {
"name": "Teamcenter V13.3",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Teamcenter V13.3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V14.0.0.2",
"product": {
"name": "Teamcenter V14.0",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Teamcenter V14.0"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-24290",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The tcserver.exe binary in affected applications is vulnerable to a stack overflow condition during the parsing of user input that may lead the binary to crash.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.13 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.0.0.9 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.1.0.9 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.8 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.3.0.3 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V14.0.0.2 or later version",
"product_ids": [
"6"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2022-24290"
},
{
"cve": "CVE-2022-29801",
"cwe": {
"id": "CWE-611",
"name": "Improper Restriction of XML External Entity Reference"
},
"notes": [
{
"category": "summary",
"text": "The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an\r\nattacker to view files on the application server filesystem.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Harden the application\u2019s host to prevent local access by untrusted\npersonnel",
"product_ids": [
"1",
"2"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V12.4.0.13 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V13.0.0.9 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2022-29801"
}
]
}
fkie_cve-2022-29801
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf | Patch, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | teamcenter | * | |
| siemens | teamcenter | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"matchCriteriaId": "955EB695-37D8-40DB-9867-B2007B9EA53D",
"versionEndExcluding": "12.4.0.13",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C0EDF96B-DF5B-4A9E-A70E-FD3EEE8067CD",
"versionEndExcluding": "13.0.0.9",
"versionStartIncluding": "13.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V12.4 (All versions \u003c V12.4.0.13), Teamcenter V13.0 (All versions \u003c V13.0.0.9). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Teamcenter V12.4 (Todas las versiones anteriores a V12.4.0.13), Teamcenter V13.0 (Todas las versiones anteriores a V13.0.0.9). La aplicaci\u00f3n contiene una vulnerabilidad de inyecci\u00f3n de entidades externas XML (XXE). Esto podr\u00eda permitir a un atacante ver archivos en el sistema de archivos del servidor de aplicaciones"
}
],
"id": "CVE-2022-29801",
"lastModified": "2024-11-21T06:59:42.700",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-05-20T13:15:15.877",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789162.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-611"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-611"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.