Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-25622 (GCVE-0-2022-25622)
Vulnerability from cvelistv5 – Published: 2022-04-12 00:00 – Updated: 2025-04-21 13:54- CWE-400 - Uncontrolled Resource Consumption
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:42:50.341Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-25622",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:29.985401Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:54:36.799Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CFU DIQ",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CFU PA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM 151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM 151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 MF HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN/2 HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN/3 HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.3",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/MF Coupler",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= 4.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 412-2 PN V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V10.1.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.5 SP1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G110M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.7.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G115D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.7.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G120 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.7 SP14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2.3.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2.3.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S110",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2 SP3 HF13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2.3.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S210 (6SL5...)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2 SP3 HF18",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS V90",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.04.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM 151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM 151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HCS4200 CIM4210",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HCS4200 CIM4210C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HCS4300 CIM4310",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET PN/PN Coupler",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= 4.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-14T10:26:55.984Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-25622",
"datePublished": "2022-04-12T00:00:00.000Z",
"dateReserved": "2022-02-21T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:54:36.799Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-25622",
"date": "2026-06-20",
"epss": "0.00818",
"percentile": "0.52362"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_cfu_diq_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CF0CF4BB-3200-4942-ADA2-120D348E03A4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_cfu_diq:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AF942F59-C13F-40FC-9601-2B4202677CC4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A5119182-CB31-466A-AB0F-7956C8B45AE0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B6C1E4CC-2657-4383-83D8-5C8F88B12755\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E4872DF2-8C81-45BA-A606-99D0A75464AC\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"602FB384-0DB2-488C-B3CC-96E3A2882976\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6668A57C-BC46-4008-B174-9E557946ACA2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1D082EB6-3C13-40C1-9949-179DC59037C1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_s7-400_pn\\\\/dp_v7_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EC44664E-830D-4122-A97A-1AFA61F5BBB5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_pn\\\\/dp_v7:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C48D93F2-FB6B-4D4D-84FB-3A7CDE89B727\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"18E1CA5D-3D7D-49D0-A417-235E2AF6075C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"926D9DCF-A7EA-416A-9A07-122D1FCA027B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_s7-410_v10_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"70A009DD-9D8A-4FF3-B65C-D1AF477D5CB5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-410_v10:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6F240847-0ADC-475C-BDDF-6483A8FF5602\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.0.0\", \"matchCriteriaId\": \"1ED5EE9B-B05A-4D2A-9FC6-0519E020FFB8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"01048F7F-9C5B-47C0-AE16-321FCA670F3D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3E2689E6-A204-4744-827E-EEFB11B7C334\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8DA1E7C4-6352-41A4-8A94-C24DDB456572\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2D9C7D4A-F989-4B01-8FFD-5B5859F42D43\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AE6AB995-D67B-43E5-B8FF-97C38D20CB10\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2E721F4E-2F84-496D-938D-A27F3E53E543\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CA5ADAB0-3985-4933-8CDD-D1546D8271CC\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:simit_simulation_platform:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7902D452-4DA8-420E-BD33-5FC112C2F5BE\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\\n\\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET200AL IM157-1 PN, SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/2 HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/3 HF (incl. variantes SIPLUS) variantes SIPLUS), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, DI 16x24VDC, M12-L, SIMATIC ET200ecoPN, DI 8x24VDC, M12-L, SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L, Acoplador SIMATIC PN/MF, Acoplador SIMATIC PN/PN, familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, familia de CPUs SIMATIC S7-300 (incl. CPUs ET200 relacionadas y variantes SIPLUS), familia de CPUs SIMATIC S7-400 H V6 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-410 V10 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-410 V8 (incl. variantes SIPLUS). variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX, SIMIT Simulation Platform, SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. variantes SIPLUS), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. variantes SIPLUS), SIMATIC S120 (incl. variantes SIPLUS). variantes SIPLUS), SINAMICS S150, SINAMICS S210, SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS HCS4200 CIM4210, SIPLUS HCS4200 CIM4210C, SIPLUS HCS4300 CIM4310, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP. La pila PROFINET (PNIO), cuando se integra con la pila IP de Interniche, maneja incorrectamente los recursos internos para los segmentos TCP en los que la longitud m\\u00ednima del TCP-Header es inferior a la definida. Esto podr\\u00eda permitir a un atacante crear una condici\\u00f3n de denegaci\\u00f3n de servicio para los servicios TCP en los dispositivos afectados mediante el env\\u00edo de segmentos TCP especialmente dise\\u00f1ados\"}]",
"id": "CVE-2022-25622",
"lastModified": "2024-11-21T06:52:27.700",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 1.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-04-12T09:15:14.483",
"references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-446448.html\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-446448.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-400\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-400\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-25622\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-04-12T09:15:14.483\",\"lastModified\":\"2024-11-21T06:52:27.700\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\\n\\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET200AL IM157-1 PN, SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/2 HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/3 HF (incl. variantes SIPLUS) variantes SIPLUS), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, DI 16x24VDC, M12-L, SIMATIC ET200ecoPN, DI 8x24VDC, M12-L, SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L, Acoplador SIMATIC PN/MF, Acoplador SIMATIC PN/PN, familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, familia de CPUs SIMATIC S7-300 (incl. CPUs ET200 relacionadas y variantes SIPLUS), familia de CPUs SIMATIC S7-400 H V6 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-410 V10 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-410 V8 (incl. variantes SIPLUS). variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX, SIMIT Simulation Platform, SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. variantes SIPLUS), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. variantes SIPLUS), SIMATIC S120 (incl. variantes SIPLUS). variantes SIPLUS), SINAMICS S150, SINAMICS S210, SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS HCS4200 CIM4210, SIPLUS HCS4200 CIM4210C, SIPLUS HCS4300 CIM4310, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP. La pila PROFINET (PNIO), cuando se integra con la pila IP de Interniche, maneja incorrectamente los recursos internos para los segmentos TCP en los que la longitud m\u00ednima del TCP-Header es inferior a la definida. Esto podr\u00eda permitir a un atacante crear una condici\u00f3n de denegaci\u00f3n de servicio para los servicios TCP en los dispositivos afectados mediante el env\u00edo de segmentos TCP especialmente dise\u00f1ados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cfu_diq_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CF0CF4BB-3200-4942-ADA2-120D348E03A4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cfu_diq:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AF942F59-C13F-40FC-9601-2B4202677CC4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A5119182-CB31-466A-AB0F-7956C8B45AE0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B6C1E4CC-2657-4383-83D8-5C8F88B12755\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E4872DF2-8C81-45BA-A606-99D0A75464AC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"602FB384-0DB2-488C-B3CC-96E3A2882976\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6668A57C-BC46-4008-B174-9E557946ACA2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D082EB6-3C13-40C1-9949-179DC59037C1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-400_pn\\\\/dp_v7_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC44664E-830D-4122-A97A-1AFA61F5BBB5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_pn\\\\/dp_v7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C48D93F2-FB6B-4D4D-84FB-3A7CDE89B727\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18E1CA5D-3D7D-49D0-A417-235E2AF6075C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"926D9DCF-A7EA-416A-9A07-122D1FCA027B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-410_v10_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"70A009DD-9D8A-4FF3-B65C-D1AF477D5CB5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-410_v10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F240847-0ADC-475C-BDDF-6483A8FF5602\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.0.0\",\"matchCriteriaId\":\"1ED5EE9B-B05A-4D2A-9FC6-0519E020FFB8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"01048F7F-9C5B-47C0-AE16-321FCA670F3D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3E2689E6-A204-4744-827E-EEFB11B7C334\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8DA1E7C4-6352-41A4-8A94-C24DDB456572\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2D9C7D4A-F989-4B01-8FFD-5B5859F42D43\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AE6AB995-D67B-43E5-B8FF-97C38D20CB10\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2E721F4E-2F84-496D-938D-A27F3E53E543\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CA5ADAB0-3985-4933-8CDD-D1546D8271CC\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simit_simulation_platform:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7902D452-4DA8-420E-BD33-5FC112C2F5BE\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-446448.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-446448.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
CERTFR-2022-AVI-329
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits SIEMENS. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance et un déni de service à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SINETPLAN toutes versions | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) V15 toutes versions | ||
| Siemens | N/A | SIMATIC WinAC RTX toutes versions | ||
| Siemens | N/A | SCALANCE X308-2M TS versions antérieures à V4.1.4 | ||
| Siemens | N/A | SICAM A8000 CP-8031 (6MF2803-1AA00) versions antérieures à V4.80 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) versions antérieures à V16 Update 5 | ||
| Siemens | N/A | SCALANCE X320-1 FE (6GK5320-1BD00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X308-2M PoE versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X304-2FE (6GK5304-2BD00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | Gamme SIMATIC S7-410 V8 (y compris variantes SIPLUS) toutes versions | ||
| Siemens | N/A | Gamme SIMATIC S7-400 H V6 (y compris variantes SIPLUS) versions antérieures à V6.0.10 | ||
| Siemens | N/A | SIMIT Simulation Platform toutes versions | ||
| Siemens | N/A | SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | Mendix Applications using Mendix 7 versions antérieures à V7.23.27 (ne corrige pas toutes les CVE) | ||
| Siemens | N/A | SIMATIC TDC CP51M1 toutes versions | ||
| Siemens | N/A | TIA Portal V15, V15.1, V16 et V17 | ||
| Siemens | N/A | SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | Gamme SIMATIC S7-400 PN/DP V7 (y compris variantes SIPLUS) toutes versions | ||
| Siemens | N/A | SCALANCE XR324-4M PoE TS versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC CFU DIQ (6ES7655-5PX31-1XX0) toutes versions | ||
| Siemens | N/A | SCALANCE X310 versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC CFU PA (6ES7655-5PX11-0XX0) toutes versions | ||
| Siemens | N/A | SCALANCE X307-2 EEC versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X408-2 (6GK5408-2FD00-2AA2) versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE XR324-4M EEC versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X307-3 versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X308-2LH+ versions antérieures à V4.1.4 | ||
| Siemens | N/A | Mendix Applications using Mendix 9 versions antérieures à V9.12.0 | ||
| Siemens | N/A | SCALANCE X310FE versions antérieures à V4.1.4 | ||
| Siemens | N/A | Gamme SIMATIC S7-1500 (y compris CPUs ET200 et variantes SIPLUS) versions antérieures à V2.0.0 | ||
| Siemens | N/A | SCALANCE X308-2 versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X308-2LD versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC Energy Manager PRO versions antérieures à V7.3 Update 1 | ||
| Siemens | N/A | Gamme SIMATIC S7-300 (y compris CPUs ET200 et variantes SIPLUS) toutes versions | ||
| Siemens | N/A | SIMATIC Energy Manager Basic versions antérieures à V7.3 Update 1 | ||
| Siemens | N/A | SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | SCALANCE XR324-12M TS versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) versions antérieures à V17 Update 2 | ||
| Siemens | N/A | Simcenter Femap versions antérieures à V2022.1. | ||
| Siemens | N/A | SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | SICAM A8000 CP-8050 (6MF2805-0AA00) versions antérieures à V4.80 | ||
| Siemens | N/A | SCALANCE X302-7 EEC versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X308-2M versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | Gamme SIMATIC S7-410 V10 (y compris variantes SIPLUS) toutes versions | ||
| Siemens | N/A | SCALANCE XR324-12M versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC TDC CPU555 toutes versions | ||
| Siemens | N/A | Mendix Applications using Mendix 8 versions antérieures à V8.18.14 (ne corrige pas toutes les CVE) | ||
| Siemens | N/A | SCALANCE X308-2LH versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC PCS neo (Administration Console) versions antérieures à V3.1 SP1 | ||
| Siemens | N/A | SCALANCE X307-3LD versions antérieures à V4.1.4 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SINETPLAN toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) V15 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinAC RTX toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2M TS versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM A8000 CP-8031 (6MF2803-1AA00) versions ant\u00e9rieures \u00e0 V4.80",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) versions ant\u00e9rieures \u00e0 V16 Update 5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X320-1 FE (6GK5320-1BD00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2M PoE versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X304-2FE (6GK5304-2BD00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-410 V8 (y compris variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-400 H V6 (y compris variantes SIPLUS) versions ant\u00e9rieures \u00e0 V6.0.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMIT Simulation Platform toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 7 versions ant\u00e9rieures \u00e0 V7.23.27 (ne corrige pas toutes les CVE)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CP51M1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Portal V15, V15.1, V16 et V17",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-400 PN/DP V7 (y compris variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-4M PoE TS versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CFU DIQ (6ES7655-5PX31-1XX0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X310 versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CFU PA (6ES7655-5PX11-0XX0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X307-2 EEC versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X408-2 (6GK5408-2FD00-2AA2) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-4M EEC versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X307-3 versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2LH+ versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 9 versions ant\u00e9rieures \u00e0 V9.12.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X310FE versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-1500 (y compris CPUs ET200 et variantes SIPLUS) versions ant\u00e9rieures \u00e0 V2.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2 versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2LD versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Energy Manager PRO versions ant\u00e9rieures \u00e0 V7.3 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-300 (y compris CPUs ET200 et variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Energy Manager Basic versions ant\u00e9rieures \u00e0 V7.3 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-12M TS versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) versions ant\u00e9rieures \u00e0 V17 Update 2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter Femap versions ant\u00e9rieures \u00e0 V2022.1.",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM A8000 CP-8050 (6MF2805-0AA00) versions ant\u00e9rieures \u00e0 V4.80",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X302-7 EEC versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2M versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-410 V10 (y compris variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-12M versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CPU555 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 8 versions ant\u00e9rieures \u00e0 V8.18.14 (ne corrige pas toutes les CVE)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2LH versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS neo (Administration Console) versions ant\u00e9rieures \u00e0 V3.1 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X307-3LD versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-27241",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27241"
},
{
"name": "CVE-2022-26380",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26380"
},
{
"name": "CVE-2022-27194",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27194"
},
{
"name": "CVE-2022-25754",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25754"
},
{
"name": "CVE-2022-28661",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28661"
},
{
"name": "CVE-2022-23448",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23448"
},
{
"name": "CVE-2022-25753",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25753"
},
{
"name": "CVE-2021-40368",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40368"
},
{
"name": "CVE-2022-26335",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26335"
},
{
"name": "CVE-2022-26334",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26334"
},
{
"name": "CVE-2022-23450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23450"
},
{
"name": "CVE-2022-28328",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28328"
},
{
"name": "CVE-2022-27481",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27481"
},
{
"name": "CVE-2022-25756",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25756"
},
{
"name": "CVE-2022-25751",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25751"
},
{
"name": "CVE-2022-28329",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28329"
},
{
"name": "CVE-2022-25650",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25650"
},
{
"name": "CVE-2022-28663",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28663"
},
{
"name": "CVE-2022-27480",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27480"
},
{
"name": "CVE-2022-28662",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28662"
},
{
"name": "CVE-2021-42029",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42029"
},
{
"name": "CVE-2022-25622",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25622"
},
{
"name": "CVE-2022-25752",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25752"
},
{
"name": "CVE-2022-25755",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25755"
},
{
"name": "CVE-2022-23449",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23449"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-329",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-04-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSIEMENS. Elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de\ncode arbitraire \u00e0 distance et un d\u00e9ni de service \u00e0 distance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits SIEMENS",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-446448 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-557541 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-557541.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-655554 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-655554.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-414513 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-414513.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-870917 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-870917.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-316850 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-316850.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-836527 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-836527.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-711829 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-711829.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-392912 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-392912.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-350757 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-350757.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-998762 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-998762.html"
}
]
}
CERTFR-2022-AVI-329
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits SIEMENS. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance et un déni de service à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SINETPLAN toutes versions | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) V15 toutes versions | ||
| Siemens | N/A | SIMATIC WinAC RTX toutes versions | ||
| Siemens | N/A | SCALANCE X308-2M TS versions antérieures à V4.1.4 | ||
| Siemens | N/A | SICAM A8000 CP-8031 (6MF2803-1AA00) versions antérieures à V4.80 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) versions antérieures à V16 Update 5 | ||
| Siemens | N/A | SCALANCE X320-1 FE (6GK5320-1BD00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X308-2M PoE versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X304-2FE (6GK5304-2BD00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | Gamme SIMATIC S7-410 V8 (y compris variantes SIPLUS) toutes versions | ||
| Siemens | N/A | Gamme SIMATIC S7-400 H V6 (y compris variantes SIPLUS) versions antérieures à V6.0.10 | ||
| Siemens | N/A | SIMIT Simulation Platform toutes versions | ||
| Siemens | N/A | SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | Mendix Applications using Mendix 7 versions antérieures à V7.23.27 (ne corrige pas toutes les CVE) | ||
| Siemens | N/A | SIMATIC TDC CP51M1 toutes versions | ||
| Siemens | N/A | TIA Portal V15, V15.1, V16 et V17 | ||
| Siemens | N/A | SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | Gamme SIMATIC S7-400 PN/DP V7 (y compris variantes SIPLUS) toutes versions | ||
| Siemens | N/A | SCALANCE XR324-4M PoE TS versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC CFU DIQ (6ES7655-5PX31-1XX0) toutes versions | ||
| Siemens | N/A | SCALANCE X310 versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC CFU PA (6ES7655-5PX11-0XX0) toutes versions | ||
| Siemens | N/A | SCALANCE X307-2 EEC versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X408-2 (6GK5408-2FD00-2AA2) versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE XR324-4M EEC versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X307-3 versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X308-2LH+ versions antérieures à V4.1.4 | ||
| Siemens | N/A | Mendix Applications using Mendix 9 versions antérieures à V9.12.0 | ||
| Siemens | N/A | SCALANCE X310FE versions antérieures à V4.1.4 | ||
| Siemens | N/A | Gamme SIMATIC S7-1500 (y compris CPUs ET200 et variantes SIPLUS) versions antérieures à V2.0.0 | ||
| Siemens | N/A | SCALANCE X308-2 versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X308-2LD versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC Energy Manager PRO versions antérieures à V7.3 Update 1 | ||
| Siemens | N/A | Gamme SIMATIC S7-300 (y compris CPUs ET200 et variantes SIPLUS) toutes versions | ||
| Siemens | N/A | SIMATIC Energy Manager Basic versions antérieures à V7.3 Update 1 | ||
| Siemens | N/A | SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | SCALANCE XR324-12M TS versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) versions antérieures à V17 Update 2 | ||
| Siemens | N/A | Simcenter Femap versions antérieures à V2022.1. | ||
| Siemens | N/A | SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | SICAM A8000 CP-8050 (6MF2805-0AA00) versions antérieures à V4.80 | ||
| Siemens | N/A | SCALANCE X302-7 EEC versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X308-2M versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | Gamme SIMATIC S7-410 V10 (y compris variantes SIPLUS) toutes versions | ||
| Siemens | N/A | SCALANCE XR324-12M versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC TDC CPU555 toutes versions | ||
| Siemens | N/A | Mendix Applications using Mendix 8 versions antérieures à V8.18.14 (ne corrige pas toutes les CVE) | ||
| Siemens | N/A | SCALANCE X308-2LH versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC PCS neo (Administration Console) versions antérieures à V3.1 SP1 | ||
| Siemens | N/A | SCALANCE X307-3LD versions antérieures à V4.1.4 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SINETPLAN toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) V15 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinAC RTX toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2M TS versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM A8000 CP-8031 (6MF2803-1AA00) versions ant\u00e9rieures \u00e0 V4.80",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) versions ant\u00e9rieures \u00e0 V16 Update 5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X320-1 FE (6GK5320-1BD00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2M PoE versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X304-2FE (6GK5304-2BD00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-410 V8 (y compris variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-400 H V6 (y compris variantes SIPLUS) versions ant\u00e9rieures \u00e0 V6.0.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMIT Simulation Platform toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 7 versions ant\u00e9rieures \u00e0 V7.23.27 (ne corrige pas toutes les CVE)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CP51M1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Portal V15, V15.1, V16 et V17",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-400 PN/DP V7 (y compris variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-4M PoE TS versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CFU DIQ (6ES7655-5PX31-1XX0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X310 versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CFU PA (6ES7655-5PX11-0XX0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X307-2 EEC versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X408-2 (6GK5408-2FD00-2AA2) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-4M EEC versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X307-3 versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2LH+ versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 9 versions ant\u00e9rieures \u00e0 V9.12.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X310FE versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-1500 (y compris CPUs ET200 et variantes SIPLUS) versions ant\u00e9rieures \u00e0 V2.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2 versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2LD versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Energy Manager PRO versions ant\u00e9rieures \u00e0 V7.3 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-300 (y compris CPUs ET200 et variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Energy Manager Basic versions ant\u00e9rieures \u00e0 V7.3 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-12M TS versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) versions ant\u00e9rieures \u00e0 V17 Update 2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter Femap versions ant\u00e9rieures \u00e0 V2022.1.",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM A8000 CP-8050 (6MF2805-0AA00) versions ant\u00e9rieures \u00e0 V4.80",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X302-7 EEC versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2M versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-410 V10 (y compris variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-12M versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CPU555 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 8 versions ant\u00e9rieures \u00e0 V8.18.14 (ne corrige pas toutes les CVE)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2LH versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS neo (Administration Console) versions ant\u00e9rieures \u00e0 V3.1 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X307-3LD versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-27241",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27241"
},
{
"name": "CVE-2022-26380",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26380"
},
{
"name": "CVE-2022-27194",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27194"
},
{
"name": "CVE-2022-25754",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25754"
},
{
"name": "CVE-2022-28661",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28661"
},
{
"name": "CVE-2022-23448",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23448"
},
{
"name": "CVE-2022-25753",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25753"
},
{
"name": "CVE-2021-40368",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40368"
},
{
"name": "CVE-2022-26335",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26335"
},
{
"name": "CVE-2022-26334",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26334"
},
{
"name": "CVE-2022-23450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23450"
},
{
"name": "CVE-2022-28328",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28328"
},
{
"name": "CVE-2022-27481",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27481"
},
{
"name": "CVE-2022-25756",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25756"
},
{
"name": "CVE-2022-25751",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25751"
},
{
"name": "CVE-2022-28329",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28329"
},
{
"name": "CVE-2022-25650",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25650"
},
{
"name": "CVE-2022-28663",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28663"
},
{
"name": "CVE-2022-27480",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27480"
},
{
"name": "CVE-2022-28662",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28662"
},
{
"name": "CVE-2021-42029",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42029"
},
{
"name": "CVE-2022-25622",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25622"
},
{
"name": "CVE-2022-25752",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25752"
},
{
"name": "CVE-2022-25755",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25755"
},
{
"name": "CVE-2022-23449",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23449"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-329",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-04-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSIEMENS. Elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de\ncode arbitraire \u00e0 distance et un d\u00e9ni de service \u00e0 distance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits SIEMENS",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-446448 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-557541 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-557541.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-655554 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-655554.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-414513 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-414513.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-870917 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-870917.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-316850 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-316850.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-836527 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-836527.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-711829 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-711829.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-392912 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-392912.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-350757 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-350757.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-998762 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-998762.html"
}
]
}
{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Siemens AG",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "- (SIMATIC ET 200ecoPN), - (SIMATIC S7-1500 CPU family), - (SIMATIC WinAC RTX 2010), - (SIMATIC S7-300 CPU family), - (SINAMICS S110), - (SIMATIC ET 200MP IM155-5 PN HF), - (SIMATIC ET 200SP IM 155-6 PN HA), - (SIMATIC ET 200SP IM155-6 PN HF), - (SIMATIC PN/PN Coupler), - (SINAMICS G150), - (SINAMICS S150), - (SIMATIC ET200AL IM 157-1 PN), - (SIMATIC CFU PA), - (SIMATIC CFU DIQ), - (SIMATIC ET 200SP IM 155-6 PN/2 HF), - (SIMATIC ET 200SP IM 155-6 PN/3 HF), - (SIMATIC PN/MF Coupler), - (Siemens SIMATIC S7-400), - (SIMATIC S7-410), - (SIMATIC TDC CP51M1), - (SIMATIC TDC CPU555), - (SIMIT), - (SINAMICS DCM), - (SINAMICS G110M), - (SINAMICS G120), - (SINAMICS G130), - (SINAMICS S120), - (SINAMICS S210), - (SINAMICS V90), - (SIPLUS HCS4200 CIM4210), - (SIPLUS HCS4200 CIM4210C), - (SIPLUS HCS4300 CIM4310), - (SIPLUS NET PN/PN Coupler)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u041a\u043e\u043c\u043f\u0435\u043d\u0441\u0438\u0440\u0443\u044e\u0449\u0438\u0435 \u043c\u0435\u0440\u044b:\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0442\u044c \u0434\u043e\u0441\u0442\u0443\u043f \u043a \u043f\u043e\u0440\u0442\u0443 102/tcp;\n- \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432 \u043c\u0435\u0436\u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u044d\u043a\u0440\u0430\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f;\n- \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u0443\u0441\u0442\u0440\u043e\u0439\u0441\u0442\u0432 \u043a \u0441\u0435\u0442\u044f\u043c \u043e\u0431\u0449\u0435\u0433\u043e \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u044f (\u0418\u043d\u0442\u0435\u0440\u043d\u0435\u0442);\n- \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0435\u0442\u0438 \u0441 \u0446\u0435\u043b\u044c\u044e \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043e\u0431\u043e\u0440\u0443\u0434\u043e\u0432\u0430\u043d\u0438\u044e \u0438\u0437 \u0434\u0440\u0443\u0433\u0438\u0445 \u043f\u043e\u0434\u0441\u0435\u0442\u0435\u0439.",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "12.04.2022",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "13.07.2022",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "13.07.2022",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2022-04330",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2022-25622",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u0435\u0442",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "SIMATIC ET 200ecoPN, SIMATIC S7-1500 CPU family, SIMATIC WinAC RTX 2010, SIMATIC S7-300 CPU family, SINAMICS S110, SIMATIC ET 200MP IM155-5 PN HF, SIMATIC ET 200SP IM 155-6 PN HA, SIMATIC ET 200SP IM155-6 PN HF, SIMATIC PN/PN Coupler, SINAMICS G150, SINAMICS S150, SIMATIC ET200AL IM 157-1 PN, SIMATIC CFU PA, SIMATIC CFU DIQ, SIMATIC ET 200SP IM 155-6 PN/2 HF, SIMATIC ET 200SP IM 155-6 PN/3 HF, SIMATIC PN/MF Coupler, Siemens SIMATIC S7-400, SIMATIC S7-410, SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMIT, SINAMICS DCM, SINAMICS G110M, SINAMICS G120, SINAMICS G130, SINAMICS S120, SINAMICS S210, SINAMICS V90, SIPLUS HCS4200 CIM4210, SIPLUS HCS4200 CIM4210C, SIPLUS HCS4300 CIM4310, SIPLUS NET PN/PN Coupler",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0441\u043b\u0443\u0436\u0431 TCP \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f Siemens, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u0439 \u0440\u0430\u0441\u0445\u043e\u0434 \u0440\u0435\u0441\u0443\u0440\u0441\u0430 (\u00ab\u0418\u0441\u0442\u043e\u0449\u0435\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u0430\u00bb) (CWE-400)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0441\u043b\u0443\u0436\u0431 TCP \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f Siemens \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u043a\u043e\u043d\u0442\u0440\u043e\u043b\u0438\u0440\u0443\u0435\u043c\u044b\u043c \u0440\u0430\u0441\u0445\u043e\u0434\u043e\u043c \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0451\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043c\u0435\u0440\u044b",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u0418\u0441\u0447\u0435\u0440\u043f\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f, \u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f, \u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430, \u041f\u041e \u0441\u0435\u0442\u0435\u0432\u043e\u0433\u043e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430, \u0421\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f, \u041c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0439 \u043a\u043e\u0434",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-400",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 5)\n\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 5,3)"
}
厂商已发布了漏洞修复程序,请及时关注更新: https://www.siemens.com/
| Name | ['SIEMENS SIMATIC S7-300 CPU family null', 'Siemens SIMATIC S7-1500 CPU family', 'SIEMENS SIMATIC TDC CP51M1', 'Siemens SIMATIC TDC CPU555', 'Siemens SIMIT Simulation Platform', 'Siemens SIMATIC CFU DIQ', 'Siemens SIMATIC CFU PA', 'Siemens SIMATIC S7-400 H V6 CPU family <6.0.10', 'Siemens SIMATIC S7-400 PN/DP V7 CPU family', 'Siemens SIMATIC S7-410 V8 CPU family', 'Siemens SIMATIC S7-410 V10 CPU family', 'Siemens SIMATIC WinAC RTX'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2022-25622"
}
},
"description": "SIMATIC S7-400 CPU\u7cfb\u5217\u4ea7\u54c1\u4e13\u4e3a\u5de5\u4e1a\u73af\u5883\u4e2d\u7684\u8fc7\u7a0b\u63a7\u5236\u800c\u8bbe\u8ba1\u3002SIMATIC S7-300 CPU\u7cfb\u5217\u4ea7\u54c1\u4e13\u4e3a\u5de5\u4e1a\u73af\u5883\u4e2d\u7684\u79bb\u6563\u548c\u8fde\u7eed\u63a7\u5236\u800c\u8bbe\u8ba1\u3002SIMATIC S7-1500 CPU\u7cfb\u5217\u4ea7\u54c1\u4e13\u4e3a\u5de5\u4e1a\u73af\u5883\u4e2d\u7684\u79bb\u6563\u548c\u8fde\u7eed\u63a7\u5236\u800c\u8bbe\u8ba1\u3002SIMATIC Compact Field Unit (SIMATIC CFU)\u662f\u4e00\u79cd\u667a\u80fd\u73b0\u573a\u5206\u914d\u5668\u3002SIMATIC ET 200\u63a5\u53e3\u6a21\u5757\u7528\u4e8e\u901a\u8fc7PROFINET\u5c06\u73b0\u573a\u8bbe\u5907\uff08IO \u8bbe\u5907\uff09\u8fde\u63a5\u5230\u63a7\u5236\u5668\u3002SIMATIC TDC\u662f\u7528\u4e8e\u9a71\u52a8\u3001\u63a7\u5236\u548c\u6280\u672f\u4efb\u52a1\u7684\u591a\u5904\u7406\u5668\u81ea\u52a8\u5316\u7cfb\u7edf\u3002SIMATIC WinAC RTX\u662f\u7528\u4e8e\u57fa\u4e8ePC\u7684\u81ea\u52a8\u5316\u89e3\u51b3\u65b9\u6848\u7684SIMATIC\u8f6f\u4ef6\u63a7\u5236\u5668\u3002SIPLUSextreme\u4ea7\u54c1\u4e13\u4e3a\u5728\u6781\u7aef\u6761\u4ef6\u4e0b\u53ef\u9760\u8fd0\u884c\u800c\u8bbe\u8ba1\u3002SIMIT Simluation Platform\u5141\u8bb8\u5bf9\u5de5\u5382\u8bbe\u7f6e\u8fdb\u884c\u4eff\u771f\uff0c\u4ee5\u4fbf\u5728\u65e9\u671f\u89c4\u5212\u9636\u6bb5\u9884\u6d4b\u6545\u969c\u3002\n\nSiemens PROFINET Stack Integrated on Interniche Stack\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u672a\u6b63\u786e\u5904\u7406\u5185\u90e8\u6700\u5c0fTCP-Header\u957f\u5ea6\u5c0f\u4e8e\u5b9a\u4e49\u7684TCP\u6bb5\u7684\u8d44\u6e90\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u901a\u8fc7\u53d1\u9001\u7279\u5236\u7684TCP\u6bb5\u6765\u4e3a\u53d7\u5f71\u54cd\u8bbe\u5907\u4e0a\u7684TCP\u670d\u52a1\u521b\u5efa\u62d2\u7edd\u670d\u52a1\u6761\u4ef6\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://www.siemens.com/",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2022-28496",
"openTime": "2022-04-13",
"patchDescription": "SIMATIC S7-400 CPU\u7cfb\u5217\u4ea7\u54c1\u4e13\u4e3a\u5de5\u4e1a\u73af\u5883\u4e2d\u7684\u8fc7\u7a0b\u63a7\u5236\u800c\u8bbe\u8ba1\u3002SIMATIC S7-300 CPU\u7cfb\u5217\u4ea7\u54c1\u4e13\u4e3a\u5de5\u4e1a\u73af\u5883\u4e2d\u7684\u79bb\u6563\u548c\u8fde\u7eed\u63a7\u5236\u800c\u8bbe\u8ba1\u3002SIMATIC S7-1500 CPU\u7cfb\u5217\u4ea7\u54c1\u4e13\u4e3a\u5de5\u4e1a\u73af\u5883\u4e2d\u7684\u79bb\u6563\u548c\u8fde\u7eed\u63a7\u5236\u800c\u8bbe\u8ba1\u3002SIMATIC Compact Field Unit (SIMATIC CFU)\u662f\u4e00\u79cd\u667a\u80fd\u73b0\u573a\u5206\u914d\u5668\u3002SIMATIC ET 200\u63a5\u53e3\u6a21\u5757\u7528\u4e8e\u901a\u8fc7PROFINET\u5c06\u73b0\u573a\u8bbe\u5907\uff08IO \u8bbe\u5907\uff09\u8fde\u63a5\u5230\u63a7\u5236\u5668\u3002SIMATIC TDC\u662f\u7528\u4e8e\u9a71\u52a8\u3001\u63a7\u5236\u548c\u6280\u672f\u4efb\u52a1\u7684\u591a\u5904\u7406\u5668\u81ea\u52a8\u5316\u7cfb\u7edf\u3002SIMATIC WinAC RTX\u662f\u7528\u4e8e\u57fa\u4e8ePC\u7684\u81ea\u52a8\u5316\u89e3\u51b3\u65b9\u6848\u7684SIMATIC\u8f6f\u4ef6\u63a7\u5236\u5668\u3002SIPLUSextreme\u4ea7\u54c1\u4e13\u4e3a\u5728\u6781\u7aef\u6761\u4ef6\u4e0b\u53ef\u9760\u8fd0\u884c\u800c\u8bbe\u8ba1\u3002SIMIT Simluation Platform\u5141\u8bb8\u5bf9\u5de5\u5382\u8bbe\u7f6e\u8fdb\u884c\u4eff\u771f\uff0c\u4ee5\u4fbf\u5728\u65e9\u671f\u89c4\u5212\u9636\u6bb5\u9884\u6d4b\u6545\u969c\u3002\r\n\r\nSiemens PROFINET Stack Integrated on Interniche Stack\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u672a\u6b63\u786e\u5904\u7406\u5185\u90e8\u6700\u5c0fTCP-Header\u957f\u5ea6\u5c0f\u4e8e\u5b9a\u4e49\u7684TCP\u6bb5\u7684\u8d44\u6e90\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u901a\u8fc7\u53d1\u9001\u7279\u5236\u7684TCP\u6bb5\u6765\u4e3a\u53d7\u5f71\u54cd\u8bbe\u5907\u4e0a\u7684TCP\u670d\u52a1\u521b\u5efa\u62d2\u7edd\u670d\u52a1\u6761\u4ef6\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens PROFINET Stack Integrated on Interniche Stack\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"SIEMENS SIMATIC S7-300 CPU family null",
"Siemens SIMATIC S7-1500 CPU family",
"SIEMENS SIMATIC TDC CP51M1",
"Siemens SIMATIC TDC CPU555",
"Siemens SIMIT Simulation Platform",
"Siemens SIMATIC CFU DIQ",
"Siemens SIMATIC CFU PA",
"Siemens SIMATIC S7-400 H V6 CPU family \u003c6.0.10",
"Siemens SIMATIC S7-400 PN/DP V7 CPU family",
"Siemens SIMATIC S7-410 V8 CPU family",
"Siemens SIMATIC S7-410 V10 CPU family",
"Siemens SIMATIC WinAC RTX"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf",
"serverity": "\u4e2d",
"submitTime": "2022-04-13",
"title": "Siemens PROFINET Stack Integrated on Interniche Stack\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e"
}
FKIE_CVE-2022-25622
Vulnerability from fkie_nvd - Published: 2022-04-12 09:15 - Updated: 2026-06-17 04:337.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CFU DIQ",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CFU PA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM 151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200S IM 151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 MF HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN/2 HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN/3 HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.3",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.1.2",
"status": "affected",
"version": "V5.1.1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/MF Coupler",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= 4.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 412-2 PN V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V10.1.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.5 SP1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G110M",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.7.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G115D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.7.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G120 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.7 SP14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2.3.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2.3.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S110",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2 SP3 HF13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2.3.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S210 (6SL5...)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.2 SP3 HF18",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS V90",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.04.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM 151-8 PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200S IM 151-8F PN/DP CPU",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V4.2.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HCS4200 CIM4210",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HCS4200 CIM4210C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HCS4300 CIM4310",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET PN/PN Coupler",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= 4.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.3.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.19"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "productcert@siemens.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cfu_diq_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CF0CF4BB-3200-4942-ADA2-120D348E03A4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cfu_diq:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AF942F59-C13F-40FC-9601-2B4202677CC4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A5119182-CB31-466A-AB0F-7956C8B45AE0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B6C1E4CC-2657-4383-83D8-5C8F88B12755",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E4872DF2-8C81-45BA-A606-99D0A75464AC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
"matchCriteriaId": "602FB384-0DB2-488C-B3CC-96E3A2882976",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6668A57C-BC46-4008-B174-9E557946ACA2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1D082EB6-3C13-40C1-9949-179DC59037C1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v7_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EC44664E-830D-4122-A97A-1AFA61F5BBB5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp_v7:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C48D93F2-FB6B-4D4D-84FB-3A7CDE89B727",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "18E1CA5D-3D7D-49D0-A417-235E2AF6075C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*",
"matchCriteriaId": "926D9DCF-A7EA-416A-9A07-122D1FCA027B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-410_v10_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "70A009DD-9D8A-4FF3-B65C-D1AF477D5CB5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-410_v10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F240847-0ADC-475C-BDDF-6483A8FF5602",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1ED5EE9B-B05A-4D2A-9FC6-0519E020FFB8",
"versionEndExcluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*",
"matchCriteriaId": "01048F7F-9C5B-47C0-AE16-321FCA670F3D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3E2689E6-A204-4744-827E-EEFB11B7C334",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8DA1E7C4-6352-41A4-8A94-C24DDB456572",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2D9C7D4A-F989-4B01-8FFD-5B5859F42D43",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE6AB995-D67B-43E5-B8FF-97C38D20CB10",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2E721F4E-2F84-496D-938D-A27F3E53E543",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simit_simulation_platform:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7902D452-4DA8-420E-BD33-5FC112C2F5BE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET200AL IM157-1 PN, SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/2 HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/3 HF (incl. variantes SIPLUS) variantes SIPLUS), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, DI 16x24VDC, M12-L, SIMATIC ET200ecoPN, DI 8x24VDC, M12-L, SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L, Acoplador SIMATIC PN/MF, Acoplador SIMATIC PN/PN, familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, familia de CPUs SIMATIC S7-300 (incl. CPUs ET200 relacionadas y variantes SIPLUS), familia de CPUs SIMATIC S7-400 H V6 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-410 V10 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-410 V8 (incl. variantes SIPLUS). variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX, SIMIT Simulation Platform, SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. variantes SIPLUS), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. variantes SIPLUS), SIMATIC S120 (incl. variantes SIPLUS). variantes SIPLUS), SINAMICS S150, SINAMICS S210, SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS HCS4200 CIM4210, SIPLUS HCS4200 CIM4210C, SIPLUS HCS4300 CIM4310, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP. La pila PROFINET (PNIO), cuando se integra con la pila IP de Interniche, maneja incorrectamente los recursos internos para los segmentos TCP en los que la longitud m\u00ednima del TCP-Header es inferior a la definida. Esto podr\u00eda permitir a un atacante crear una condici\u00f3n de denegaci\u00f3n de servicio para los servicios TCP en los dispositivos afectados mediante el env\u00edo de segmentos TCP especialmente dise\u00f1ados"
}
],
"id": "CVE-2022-25622",
"lastModified": "2026-06-17T04:33:47.293",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-25622",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:12:29.985401Z",
"version": "2.0.3"
}
}
]
},
"published": "2022-04-12T09:15:14.483",
"references": [
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
},
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-PGXC-2Q22-7C2F
Vulnerability from github – Published: 2022-04-13 00:00 – Updated: 2024-05-14 18:30A vulnerability has been identified in SIMATIC CFU DIQ (All versions), SIMATIC CFU PA (All versions), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.0.0), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.10), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (All versions), SIMIT Simulation Platform (All versions). The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
{
"affected": [],
"aliases": [
"CVE-2022-25622"
],
"database_specific": {
"cwe_ids": [
"CWE-400"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-04-12T09:15:00Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in SIMATIC CFU DIQ (All versions), SIMATIC CFU PA (All versions), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.0.0), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions \u003c V6.0.10), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (All versions), SIMIT Simulation Platform (All versions). The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.",
"id": "GHSA-pgxc-2q22-7c2f",
"modified": "2024-05-14T18:30:33Z",
"published": "2022-04-13T00:00:33Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-25622"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2022-25622
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-25622",
"description": "A vulnerability has been identified in SIMATIC CFU DIQ (All versions), SIMATIC CFU PA (All versions), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.0.0), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions \u003c V6.0.10), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (All versions), SIMIT Simulation Platform (All versions). The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.",
"id": "GSD-2022-25622"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-25622"
],
"details": "A vulnerability has been identified in SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200AL IM157-1 PN, SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L, SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L, SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, DI 16x24VDC, M12-L, SIMATIC ET200ecoPN, DI 8x24VDC, M12-L, SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L, SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC PN/MF Coupler, SIMATIC PN/PN Coupler, SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. SIPLUS variants), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. SIPLUS variants), SINAMICS S150, SINAMICS S210, SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS HCS4200 CIM4210, SIPLUS HCS4200 CIM4210C, SIPLUS HCS4300 CIM4310, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.",
"id": "GSD-2022-25622",
"modified": "2023-12-13T01:19:27.147327Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-25622",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC CFU DIQ",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC CFU PA",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC ET 200S IM151-8 PN/DP CPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC ET 200S IM151-8F PN/DP CPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC ET200AL IM157-1 PN",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V5.1.1"
}
]
}
},
{
"product_name": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V5.1.1"
}
]
}
},
{
"product_name": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V5.1.1"
},
{
"version_affected": "=",
"version_value": "All versions \u003e= V5.1.1"
}
]
}
},
{
"product_name": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V5.1.1"
}
]
}
},
{
"product_name": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V5.1.1"
}
]
}
},
{
"product_name": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V5.1.1"
}
]
}
},
{
"product_name": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V5.1.1"
}
]
}
},
{
"product_name": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V5.1.1"
}
]
}
},
{
"product_name": "SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V4.2"
}
]
}
},
{
"product_name": "SIMATIC ET200SP IM155-6 MF HF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V4.2"
}
]
}
},
{
"product_name": "SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V4.2"
}
]
}
},
{
"product_name": "SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= V4.2"
}
]
}
},
{
"product_name": "SIMATIC PN/MF Coupler",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC PN/PN Coupler",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= 4.2"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.0.0"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU 314C-2 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.3.19"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU 315-2 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU 315F-2 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU 315T-3 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU 317-2 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU 317F-2 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU 317T-3 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU 319-3 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU 319F-3 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIMATIC S7-400 CPU 412-2 PN V7",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V6.0.10"
}
]
}
},
{
"product_name": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V10.1.1"
}
]
}
},
{
"product_name": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V8.2.3"
}
]
}
},
{
"product_name": "SIMATIC TDC CP51M1",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V1.1.10"
}
]
}
},
{
"product_name": "SIMATIC TDC CPU555",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V1.2.1"
}
]
}
},
{
"product_name": "SIMATIC WinAC RTX 2010",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC WinAC RTX F 2010",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINAMICS DCM",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions with Ethernet interface"
}
]
}
},
{
"product_name": "SINAMICS G110M",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.7.14 with Ethernet interface"
}
]
}
},
{
"product_name": "SINAMICS G115D",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.7.14 with Ethernet interface"
}
]
}
},
{
"product_name": "SINAMICS G120 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V4.7.14 with Ethernet interface"
}
]
}
},
{
"product_name": "SINAMICS G130",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V5.2.3.13"
}
]
}
},
{
"product_name": "SINAMICS G150",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V5.2.3.13"
}
]
}
},
{
"product_name": "SINAMICS S110",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions with Ethernet interface"
}
]
}
},
{
"product_name": "SINAMICS S120 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V5.2.3.13"
}
]
}
},
{
"product_name": "SINAMICS S150",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V5.2.3.13"
}
]
}
},
{
"product_name": "SINAMICS S210",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINAMICS V90",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions with Ethernet interface"
}
]
}
},
{
"product_name": "SIPLUS ET 200S IM151-8 PN/DP CPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIPLUS ET 200S IM151-8F PN/DP CPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIPLUS HCS4200 CIM4210",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIPLUS HCS4200 CIM4210C",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIPLUS HCS4300 CIM4310",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIPLUS NET PN/PN Coupler",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003e= 4.2"
}
]
}
},
{
"product_name": "SIPLUS S7-300 CPU 314C-2 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.3.19"
}
]
}
},
{
"product_name": "SIPLUS S7-300 CPU 315-2 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIPLUS S7-300 CPU 315F-2 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIPLUS S7-300 CPU 317-2 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIPLUS S7-300 CPU 317F-2 PN/DP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V3.2.19"
}
]
}
},
{
"product_name": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200AL IM157-1 PN, SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L, SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L, SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, DI 16x24VDC, M12-L, SIMATIC ET200ecoPN, DI 8x24VDC, M12-L, SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L, SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC PN/MF Coupler, SIMATIC PN/PN Coupler, SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. SIPLUS variants), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. SIPLUS variants), SINAMICS S150, SINAMICS S210, SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS HCS4200 CIM4210, SIPLUS HCS4200 CIM4210C, SIPLUS HCS4300 CIM4310, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments."
}
]
},
"impact": {
"cvss": [
{
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-400",
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_cfu_diq_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_cfu_diq:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v7_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp_v7:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v10_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v10:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simit_simulation_platform:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-25622"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200AL IM157-1 PN, SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L, SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L, SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, DI 16x24VDC, M12-L, SIMATIC ET200ecoPN, DI 8x24VDC, M12-L, SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L, SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC PN/MF Coupler, SIMATIC PN/PN Coupler, SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. SIPLUS variants), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. SIPLUS variants), SINAMICS S150, SINAMICS S210, SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS HCS4200 CIM4210, SIPLUS HCS4200 CIM4210C, SIPLUS HCS4300 CIM4310, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2023-07-11T10:15Z",
"publishedDate": "2022-04-12T09:15Z"
}
}
}
ICSA-22-104-06
Vulnerability from csaf_cisa - Published: 2022-04-12 00:00 - Updated: 2025-01-14 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC CFU DIQ (6ES7655-5PX31-1XX0)
Siemens / SIMATIC CFU DIQ (6ES7655-5PX31-1XX0)
|
6ES7655-5PX31-1XX0
|
vers:all/<V2.0.0 |
Mitigation
Vendor Fix
|
|
SIMATIC CFU PA (6ES7655-5PX11-0XX0)
Siemens / SIMATIC CFU PA (6ES7655-5PX11-0XX0)
|
6ES7655-5PX11-0XX0
|
vers:all/<V2.0.0 |
Mitigation
Vendor Fix
|
|
SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)
Siemens / SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)
|
6ES7157-1AB00-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)
Siemens / SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)
|
6ES7155-5AA00-0AC0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)
Siemens / SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)
|
6ES7154-8AB01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)
Siemens / SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)
|
6ES7154-8FB01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)
Siemens / SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)
|
6ES7154-8FX00-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)
Siemens / SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)
|
6ES7151-8AB01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)
Siemens / SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)
|
6ES7151-8FB01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0)
Siemens / SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0)
|
6ES7155-6MU00-0CN0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)
Siemens / SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)
Siemens / SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)
|
6ES7155-6AU00-0CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0)
Siemens / SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0)
|
6ES7155-6AU01-0CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0)
Siemens / SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0)
|
6ES7155-6AU30-0CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0)
Siemens / SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0)
|
6ES7144-6JF00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0)
Siemens / SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0)
|
6ES7148-6JE00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0)
Siemens / SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0)
|
6ES7148-6JG00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0)
Siemens / SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0)
|
6ES7148-6JJ00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0)
Siemens / SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0)
|
6ES7141-6BH00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0)
Siemens / SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0)
|
6ES7141-6BG00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0)
Siemens / SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0)
|
6ES7143-6BH00-0BB0
|
vers:all/>=V5.1.1|<V5.1.3 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0)
Siemens / SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0)
|
6ES7142-6BG00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0)
Siemens / SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0)
|
6ES7142-6BR00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0)
Siemens / SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0)
|
6ES7158-3MU10-0XA0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0)
Siemens / SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0)
|
6ES7158-3AD10-0XA0
|
vers:all/>=4.2 |
Mitigation
No Fix Planned
|
|
SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
Siemens / SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
|
vers:all/<V2.0.0 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)
Siemens / SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)
|
6ES7314-6EH04-0AB0
|
vers:all/<V3.3.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)
Siemens / SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)
|
6ES7315-2EH14-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)
Siemens / SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)
|
6ES7315-2FJ14-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)
Siemens / SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)
|
6ES7315-7TJ10-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)
Siemens / SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)
|
6ES7317-2EK14-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)
Siemens / SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)
|
6ES7317-2FK14-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)
Siemens / SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)
|
6ES7317-7TK10-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)
Siemens / SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)
|
6ES7317-7UL10-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)
Siemens / SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)
|
6ES7318-3EL01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)
Siemens / SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)
|
6ES7318-3FL01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0)
Siemens / SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0)
|
6ES7412-2EK07-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0)
Siemens / SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0)
|
6ES7414-3EM07-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0)
Siemens / SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0)
|
6ES7414-3FM07-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0)
Siemens / SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0)
|
6ES7416-3ES07-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0)
Siemens / SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0)
|
6ES7416-3FS07-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)
Siemens / SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)
|
vers:all/<V6.0.10 |
Mitigation
Vendor Fix
|
|
|
SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)
Siemens / SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)
|
vers:all/<V10.1.1 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)
Siemens / SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)
|
vers:all/<V8.2.3 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC TDC CP51M1
Siemens / SIMATIC TDC CP51M1
|
vers:all/<V1.1.10 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC TDC CPU555
Siemens / SIMATIC TDC CPU555
|
vers:all/<V1.2.1 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)
Siemens / SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)
|
6ES7671-0RC08-0YA0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)
Siemens / SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)
|
6ES7671-1RC08-0YA0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SINAMICS DCM
Siemens / SINAMICS DCM
|
<V1.5_SP1_with_Ethernet_interface |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS G110M
Siemens / SINAMICS G110M
|
vers:all/<V4.7.14 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS G115D
Siemens / SINAMICS G115D
|
vers:all/<V4.7.14 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS G120 (incl. SIPLUS variants)
Siemens / SINAMICS G120 (incl. SIPLUS variants)
|
<V4.7_SP14_with_Ethernet_interface |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS G130
Siemens / SINAMICS G130
|
vers:all/<V5.2.3.13 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS G150
Siemens / SINAMICS G150
|
vers:all/<V5.2.3.13 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS S110
Siemens / SINAMICS S110
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SINAMICS S120 (incl. SIPLUS variants)
Siemens / SINAMICS S120 (incl. SIPLUS variants)
|
<V5.2_SP3_HF13 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS S150
Siemens / SINAMICS S150
|
vers:all/<V5.2.3.13 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS S210 (6SL5...)
Siemens / SINAMICS S210 (6SL5...)
|
<V5.2_SP3_HF18 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS V90
Siemens / SINAMICS V90
|
vers:all/<V1.04.04 |
Mitigation
Vendor Fix
fix
|
|
|
SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)
Siemens / SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)
|
6AG1155-5AA00-2AC0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)
Siemens / SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)
|
6AG1155-5AA00-7AC0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)
Siemens / SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)
|
6AG2155-5AA00-1AC0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)
Siemens / SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)
|
6AG1151-8AB01-7AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)
Siemens / SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)
|
6AG1151-8FB01-2AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)
|
6AG1155-6AU00-2CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)
|
6AG1155-6AU00-4CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0)
|
6AG1155-6AU01-2CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0)
|
6AG1155-6AU01-7CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)
|
6AG2155-6AU00-1CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0)
|
6AG2155-6AU01-1CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0)
|
6AG2155-6AU01-4CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0)
Siemens / SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0)
|
6BK1942-1AA00-0AA0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1)
Siemens / SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1)
|
6BK1942-1AA00-0AA1
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0)
Siemens / SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0)
|
6BK1943-1AA00-0AA0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0)
Siemens / SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0)
|
6AG2158-3AD10-4XA0
|
vers:all/>=4.2 |
Mitigation
No Fix Planned
|
|
SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)
Siemens / SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)
|
6AG1314-6EH04-7AB0
|
vers:all/<V3.3.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)
Siemens / SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)
|
6AG1315-2EH14-7AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)
Siemens / SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)
|
6AG1315-2FJ14-2AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)
Siemens / SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)
|
6AG1317-2EK14-7AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)
Siemens / SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)
|
6AG1317-2FK14-2AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0)
Siemens / SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0)
|
6AG1414-3EM07-7AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0)
Siemens / SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0)
|
6AG1416-3ES07-7AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-446448: Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-446448.json"
},
{
"category": "self",
"summary": "SSA-446448: Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-104-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-104-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-22-104-06 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens PROFINET Stack Integrated on Interniche Stack",
"tracking": {
"current_release_date": "2025-01-14T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-22-104-06",
"initial_release_date": "2022-04-12T00:00:00.000000Z",
"revision_history": [
{
"date": "2022-04-12T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2022-06-14T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added ET200SP/MP/AL/EcoPN, PN/xx Coupler, SIPLUS HCS4x00 and SINAMICS products to the list of affected products"
},
{
"date": "2022-07-12T00:00:00.000000Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added SINAMICS S110/V90/DCM products to the list of affected products. Additional details added to SINAMICS affected versions"
},
{
"date": "2022-08-09T00:00:00.000000Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added fix for SIMATIC S7-410 CPU family"
},
{
"date": "2022-10-11T00:00:00.000000Z",
"legacy_version": "1.4",
"number": "5",
"summary": "Added fix for SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants); removed SIMIT Simulation Platform as not affected"
},
{
"date": "2022-12-13T00:00:00.000000Z",
"legacy_version": "1.5",
"number": "6",
"summary": "Added fix for SIMATIC S7-410 V10 CPU family and SIMATIC TDC"
},
{
"date": "2023-01-10T00:00:00.000000Z",
"legacy_version": "1.6",
"number": "7",
"summary": "No fix planned for SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), added fix for SINAMICS S120 (incl. SIPLUS variants)"
},
{
"date": "2023-02-14T00:00:00.000000Z",
"legacy_version": "1.7",
"number": "8",
"summary": "Added additional SIMATIC ET200ecoPN products (CM 4x IO-Link, M12-L / CM 8x IO-Link, M12-L / AI 8xRTD/TC, M12-L) to the list of affected products"
},
{
"date": "2023-04-11T00:00:00.000000Z",
"legacy_version": "1.8",
"number": "9",
"summary": "Added fix for SINAMICS G130, G150, S150"
},
{
"date": "2023-07-11T00:00:00.000000Z",
"legacy_version": "1.9",
"number": "10",
"summary": "Added fix for SINAMICS G110M, G115D, G120; Expanded SIMATIC S7-400 V7 CPU family to individual products and MLFBs; clarified that no fix is planned for SIMATIC S7-400 PN/DP V7 CPUs, while other S7-400 V7 CPUs are not affected"
},
{
"date": "2024-05-14T00:00:00.000000Z",
"legacy_version": "2.0",
"number": "11",
"summary": "Added fix for several SIMATIC ET200ecoPN devices"
},
{
"date": "2024-06-11T00:00:00.000000Z",
"legacy_version": "2.1",
"number": "12",
"summary": "Added fix for SINAMICS S210, SIMATIC CFU DIQ and SIMATIC CFU PA"
},
{
"date": "2024-07-09T00:00:00.000000Z",
"legacy_version": "2.2",
"number": "13",
"summary": "Added fix for SINAMICS DCM and SINAMICS V90; clarified that no fix is planned for SINAMICS S110; listed affected products individually instead of product families (e.g., for SIMATIC ET 200AL/MP/SP/pro IM families); added affected SIPLUS devices (e.g., SIPLUS ET 200xx IM)"
},
{
"date": "2025-01-14T00:00:00.000000Z",
"legacy_version": "2.3",
"number": "14",
"summary": "Added fix for SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0) and SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0)"
}
],
"status": "final",
"version": "14"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.0.0",
"product": {
"name": "SIMATIC CFU DIQ (6ES7655-5PX31-1XX0)",
"product_id": "CSAFPID-0001",
"product_identification_helper": {
"model_numbers": [
"6ES7655-5PX31-1XX0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC CFU DIQ (6ES7655-5PX31-1XX0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.0.0",
"product": {
"name": "SIMATIC CFU PA (6ES7655-5PX11-0XX0)",
"product_id": "CSAFPID-0002",
"product_identification_helper": {
"model_numbers": [
"6ES7655-5PX11-0XX0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC CFU PA (6ES7655-5PX11-0XX0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0)",
"product_id": "CSAFPID-0003",
"product_identification_helper": {
"model_numbers": [
"6ES7144-6JF00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0)",
"product_id": "CSAFPID-0004",
"product_identification_helper": {
"model_numbers": [
"6ES7148-6JE00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0)",
"product_id": "CSAFPID-0005",
"product_identification_helper": {
"model_numbers": [
"6ES7148-6JG00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0)",
"product_id": "CSAFPID-0006",
"product_identification_helper": {
"model_numbers": [
"6ES7148-6JJ00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0)",
"product_id": "CSAFPID-0007",
"product_identification_helper": {
"model_numbers": [
"6ES7141-6BG00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0)",
"product_id": "CSAFPID-0008",
"product_identification_helper": {
"model_numbers": [
"6ES7141-6BH00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.3",
"product": {
"name": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0)",
"product_id": "CSAFPID-0009",
"product_identification_helper": {
"model_numbers": [
"6ES7143-6BH00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0)",
"product_id": "CSAFPID-0010",
"product_identification_helper": {
"model_numbers": [
"6ES7142-6BG00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0)",
"product_id": "CSAFPID-0011",
"product_identification_helper": {
"model_numbers": [
"6ES7142-6BR00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)",
"product_id": "CSAFPID-0012",
"product_identification_helper": {
"model_numbers": [
"6ES7157-1AB00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)",
"product_id": "CSAFPID-0013",
"product_identification_helper": {
"model_numbers": [
"6ES7155-5AA00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)",
"product_id": "CSAFPID-0014",
"product_identification_helper": {
"model_numbers": [
"6ES7154-8AB01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)",
"product_id": "CSAFPID-0015",
"product_identification_helper": {
"model_numbers": [
"6ES7154-8FB01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)",
"product_id": "CSAFPID-0016",
"product_identification_helper": {
"model_numbers": [
"6ES7154-8FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)",
"product_id": "CSAFPID-0017",
"product_identification_helper": {
"model_numbers": [
"6ES7151-8AB01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)",
"product_id": "CSAFPID-0018",
"product_identification_helper": {
"model_numbers": [
"6ES7151-8FB01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0)",
"product_id": "CSAFPID-0019",
"product_identification_helper": {
"model_numbers": [
"6ES7155-6MU00-0CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
"product_id": "CSAFPID-0020"
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)",
"product_id": "CSAFPID-0021",
"product_identification_helper": {
"model_numbers": [
"6ES7155-6AU00-0CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0)",
"product_id": "CSAFPID-0022",
"product_identification_helper": {
"model_numbers": [
"6ES7155-6AU01-0CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0)",
"product_id": "CSAFPID-0023",
"product_identification_helper": {
"model_numbers": [
"6ES7155-6AU30-0CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0)",
"product_id": "CSAFPID-0024",
"product_identification_helper": {
"model_numbers": [
"6ES7158-3MU10-0XA0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=4.2",
"product": {
"name": "SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0)",
"product_id": "CSAFPID-0025",
"product_identification_helper": {
"model_numbers": [
"6ES7158-3AD10-0XA0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.3.19",
"product": {
"name": "SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)",
"product_id": "CSAFPID-0026",
"product_identification_helper": {
"model_numbers": [
"6ES7314-6EH04-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)",
"product_id": "CSAFPID-0027",
"product_identification_helper": {
"model_numbers": [
"6ES7315-2EH14-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)",
"product_id": "CSAFPID-0028",
"product_identification_helper": {
"model_numbers": [
"6ES7315-2FJ14-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)",
"product_id": "CSAFPID-0029",
"product_identification_helper": {
"model_numbers": [
"6ES7315-7TJ10-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)",
"product_id": "CSAFPID-0030",
"product_identification_helper": {
"model_numbers": [
"6ES7317-2EK14-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)",
"product_id": "CSAFPID-0031",
"product_identification_helper": {
"model_numbers": [
"6ES7317-2FK14-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)",
"product_id": "CSAFPID-0032",
"product_identification_helper": {
"model_numbers": [
"6ES7317-7TK10-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)",
"product_id": "CSAFPID-0033",
"product_identification_helper": {
"model_numbers": [
"6ES7317-7UL10-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)",
"product_id": "CSAFPID-0034",
"product_identification_helper": {
"model_numbers": [
"6ES7318-3EL01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)",
"product_id": "CSAFPID-0035",
"product_identification_helper": {
"model_numbers": [
"6ES7318-3FL01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0)",
"product_id": "CSAFPID-0036",
"product_identification_helper": {
"model_numbers": [
"6ES7412-2EK07-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0)",
"product_id": "CSAFPID-0037",
"product_identification_helper": {
"model_numbers": [
"6ES7414-3EM07-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0)",
"product_id": "CSAFPID-0038",
"product_identification_helper": {
"model_numbers": [
"6ES7414-3FM07-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0)",
"product_id": "CSAFPID-0039",
"product_identification_helper": {
"model_numbers": [
"6ES7416-3ES07-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0)",
"product_id": "CSAFPID-0040",
"product_identification_helper": {
"model_numbers": [
"6ES7416-3FS07-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV6.0.10",
"product": {
"name": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"product_id": "CSAFPID-0041"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV8.2.3",
"product": {
"name": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
"product_id": "CSAFPID-0042"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV10.1.1",
"product": {
"name": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)",
"product_id": "CSAFPID-0043"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.0.0",
"product": {
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"product_id": "CSAFPID-0044"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV1.1.10",
"product": {
"name": "SIMATIC TDC CP51M1",
"product_id": "CSAFPID-0045"
}
}
],
"category": "product_name",
"name": "SIMATIC TDC CP51M1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV1.2.1",
"product": {
"name": "SIMATIC TDC CPU555",
"product_id": "CSAFPID-0046"
}
}
],
"category": "product_name",
"name": "SIMATIC TDC CPU555"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)",
"product_id": "CSAFPID-0047",
"product_identification_helper": {
"model_numbers": [
"6ES7671-0RC08-0YA0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)",
"product_id": "CSAFPID-0048",
"product_identification_helper": {
"model_numbers": [
"6ES7671-1RC08-0YA0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV1.5_SP1_with_Ethernet_interface",
"product": {
"name": "SINAMICS DCM",
"product_id": "CSAFPID-0049"
}
}
],
"category": "product_name",
"name": "SINAMICS DCM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV4.7.14",
"product": {
"name": "SINAMICS G110M",
"product_id": "CSAFPID-0050"
}
}
],
"category": "product_name",
"name": "SINAMICS G110M"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV4.7.14",
"product": {
"name": "SINAMICS G115D",
"product_id": "CSAFPID-0051"
}
}
],
"category": "product_name",
"name": "SINAMICS G115D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV4.7_SP14_with_Ethernet_interface",
"product": {
"name": "SINAMICS G120 (incl. SIPLUS variants)",
"product_id": "CSAFPID-0052"
}
}
],
"category": "product_name",
"name": "SINAMICS G120 (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.2.3.13",
"product": {
"name": "SINAMICS G130",
"product_id": "CSAFPID-0053"
}
}
],
"category": "product_name",
"name": "SINAMICS G130"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.2.3.13",
"product": {
"name": "SINAMICS G150",
"product_id": "CSAFPID-0054"
}
}
],
"category": "product_name",
"name": "SINAMICS G150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS S110",
"product_id": "CSAFPID-0055"
}
}
],
"category": "product_name",
"name": "SINAMICS S110"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2_SP3_HF13",
"product": {
"name": "SINAMICS S120 (incl. SIPLUS variants)",
"product_id": "CSAFPID-0056"
}
}
],
"category": "product_name",
"name": "SINAMICS S120 (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.2.3.13",
"product": {
"name": "SINAMICS S150",
"product_id": "CSAFPID-0057"
}
}
],
"category": "product_name",
"name": "SINAMICS S150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV5.2_SP3_HF18",
"product": {
"name": "SINAMICS S210 (6SL5...)",
"product_id": "CSAFPID-0058"
}
}
],
"category": "product_name",
"name": "SINAMICS S210 (6SL5...)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV1.04.04",
"product": {
"name": "SINAMICS V90",
"product_id": "CSAFPID-0059"
}
}
],
"category": "product_name",
"name": "SINAMICS V90"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)",
"product_id": "CSAFPID-0060",
"product_identification_helper": {
"model_numbers": [
"6AG1155-5AA00-2AC0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)",
"product_id": "CSAFPID-0061",
"product_identification_helper": {
"model_numbers": [
"6AG1155-5AA00-7AC0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)",
"product_id": "CSAFPID-0062",
"product_identification_helper": {
"model_numbers": [
"6AG2155-5AA00-1AC0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)",
"product_id": "CSAFPID-0063",
"product_identification_helper": {
"model_numbers": [
"6AG1151-8AB01-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)",
"product_id": "CSAFPID-0064",
"product_identification_helper": {
"model_numbers": [
"6AG1151-8FB01-2AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)",
"product_id": "CSAFPID-0065",
"product_identification_helper": {
"model_numbers": [
"6AG1155-6AU00-2CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)",
"product_id": "CSAFPID-0066",
"product_identification_helper": {
"model_numbers": [
"6AG1155-6AU00-4CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0)",
"product_id": "CSAFPID-0067",
"product_identification_helper": {
"model_numbers": [
"6AG1155-6AU01-2CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0)",
"product_id": "CSAFPID-0068",
"product_identification_helper": {
"model_numbers": [
"6AG1155-6AU01-7CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)",
"product_id": "CSAFPID-0069",
"product_identification_helper": {
"model_numbers": [
"6AG2155-6AU00-1CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0)",
"product_id": "CSAFPID-0070",
"product_identification_helper": {
"model_numbers": [
"6AG2155-6AU01-1CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0)",
"product_id": "CSAFPID-0071",
"product_identification_helper": {
"model_numbers": [
"6AG2155-6AU01-4CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0)",
"product_id": "CSAFPID-0072",
"product_identification_helper": {
"model_numbers": [
"6BK1942-1AA00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1)",
"product_id": "CSAFPID-0073",
"product_identification_helper": {
"model_numbers": [
"6BK1942-1AA00-0AA1"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0)",
"product_id": "CSAFPID-0074",
"product_identification_helper": {
"model_numbers": [
"6BK1943-1AA00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=4.2",
"product": {
"name": "SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0)",
"product_id": "CSAFPID-0075",
"product_identification_helper": {
"model_numbers": [
"6AG2158-3AD10-4XA0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.3.19",
"product": {
"name": "SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)",
"product_id": "CSAFPID-0076",
"product_identification_helper": {
"model_numbers": [
"6AG1314-6EH04-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)",
"product_id": "CSAFPID-0077",
"product_identification_helper": {
"model_numbers": [
"6AG1315-2EH14-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)",
"product_id": "CSAFPID-0078",
"product_identification_helper": {
"model_numbers": [
"6AG1315-2FJ14-2AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)",
"product_id": "CSAFPID-0079",
"product_identification_helper": {
"model_numbers": [
"6AG1317-2EK14-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)",
"product_id": "CSAFPID-0080",
"product_identification_helper": {
"model_numbers": [
"6AG1317-2FK14-2AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0)",
"product_id": "CSAFPID-0081",
"product_identification_helper": {
"model_numbers": [
"6AG1414-3EM07-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0)",
"product_id": "CSAFPID-0082",
"product_identification_helper": {
"model_numbers": [
"6AG1416-3ES07-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-25622",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0044",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0043",
"CSAFPID-0042",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Limit access to port 102/tcp to trusted users and systems only",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0044",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0043",
"CSAFPID-0042",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0055",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0081",
"CSAFPID-0082"
]
},
{
"category": "vendor_fix",
"details": "Update to V1.04.04 or later version",
"product_ids": [
"CSAFPID-0059"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109746210/"
},
{
"category": "vendor_fix",
"details": "Update to V1.1.10 or later version",
"product_ids": [
"CSAFPID-0045"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/27049282/"
},
{
"category": "vendor_fix",
"details": "Update to V1.2.1 or later version",
"product_ids": [
"CSAFPID-0046"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109740119/"
},
{
"category": "vendor_fix",
"details": "Update to V1.5 SP1 or later version",
"product_ids": [
"CSAFPID-0049"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/44029688/"
},
{
"category": "vendor_fix",
"details": "Update to V2.0.0 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to V4.7.14 or later version",
"product_ids": [
"CSAFPID-0050",
"CSAFPID-0051"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817231/"
},
{
"category": "vendor_fix",
"details": "Update to V4.7 SP14 or later version",
"product_ids": [
"CSAFPID-0052"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817231/"
},
{
"category": "vendor_fix",
"details": "Update to V5.1.2 or later version",
"product_ids": [
"CSAFPID-0005"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.1.2 or later version",
"product_ids": [
"CSAFPID-0003",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0010",
"CSAFPID-0011"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.1.2 or later version",
"product_ids": [
"CSAFPID-0004"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.1.2 or later version",
"product_ids": [
"CSAFPID-0006"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.1.3 or later version",
"product_ids": [
"CSAFPID-0009"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.2 SP3 HF13 or later version",
"product_ids": [
"CSAFPID-0056"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109780844/"
},
{
"category": "vendor_fix",
"details": "Update to V5.2.3.13 or later version",
"product_ids": [
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0057"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109764679/"
},
{
"category": "vendor_fix",
"details": "Update to V5.2 SP3 HF18 or later version",
"product_ids": [
"CSAFPID-0058"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945645/"
},
{
"category": "vendor_fix",
"details": "Update to V6.0.10 or later version",
"product_ids": [
"CSAFPID-0041"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.2.3 or later version",
"product_ids": [
"CSAFPID-0042"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109476571/"
},
{
"category": "vendor_fix",
"details": "Update to V2.0.0 or later version",
"product_ids": [
"CSAFPID-0044"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109478459/"
},
{
"category": "vendor_fix",
"details": "Update to V10.1.1 or later version",
"product_ids": [
"CSAFPID-0043"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109773044/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0027",
"CSAFPID-0077"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/40360647/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0030",
"CSAFPID-0079"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/40362228/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0034"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/44442927/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0035"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/44443101/"
},
{
"category": "vendor_fix",
"details": "Update to V3.3.19 or later version",
"product_ids": [
"CSAFPID-0026",
"CSAFPID-0076"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/51466769/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0028",
"CSAFPID-0078"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/40944925/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0031",
"CSAFPID-0080"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/40945128/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0032"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/85059804/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0029"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/85049260/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0033"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/85063017/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0017",
"CSAFPID-0063"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/47353723/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0018",
"CSAFPID-0064"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/47354354/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0014"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/47354502/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0015"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/47354578/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"CSAFPID-0016"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/62612377/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0012",
"CSAFPID-0013",
"CSAFPID-0014",
"CSAFPID-0015",
"CSAFPID-0016",
"CSAFPID-0017",
"CSAFPID-0018",
"CSAFPID-0019",
"CSAFPID-0020",
"CSAFPID-0021",
"CSAFPID-0022",
"CSAFPID-0023",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005",
"CSAFPID-0006",
"CSAFPID-0008",
"CSAFPID-0007",
"CSAFPID-0009",
"CSAFPID-0010",
"CSAFPID-0011",
"CSAFPID-0024",
"CSAFPID-0025",
"CSAFPID-0044",
"CSAFPID-0026",
"CSAFPID-0027",
"CSAFPID-0028",
"CSAFPID-0029",
"CSAFPID-0030",
"CSAFPID-0031",
"CSAFPID-0032",
"CSAFPID-0033",
"CSAFPID-0034",
"CSAFPID-0035",
"CSAFPID-0036",
"CSAFPID-0037",
"CSAFPID-0038",
"CSAFPID-0039",
"CSAFPID-0040",
"CSAFPID-0041",
"CSAFPID-0043",
"CSAFPID-0042",
"CSAFPID-0045",
"CSAFPID-0046",
"CSAFPID-0047",
"CSAFPID-0048",
"CSAFPID-0049",
"CSAFPID-0050",
"CSAFPID-0051",
"CSAFPID-0052",
"CSAFPID-0053",
"CSAFPID-0054",
"CSAFPID-0055",
"CSAFPID-0056",
"CSAFPID-0057",
"CSAFPID-0058",
"CSAFPID-0059",
"CSAFPID-0060",
"CSAFPID-0061",
"CSAFPID-0062",
"CSAFPID-0063",
"CSAFPID-0064",
"CSAFPID-0065",
"CSAFPID-0066",
"CSAFPID-0067",
"CSAFPID-0068",
"CSAFPID-0069",
"CSAFPID-0070",
"CSAFPID-0071",
"CSAFPID-0072",
"CSAFPID-0073",
"CSAFPID-0074",
"CSAFPID-0075",
"CSAFPID-0076",
"CSAFPID-0077",
"CSAFPID-0078",
"CSAFPID-0079",
"CSAFPID-0080",
"CSAFPID-0081",
"CSAFPID-0082"
]
}
],
"title": "CVE-2022-25622"
}
]
}
SSA-446448
Vulnerability from csaf_siemens - Published: 2022-04-12 00:00 - Updated: 2025-01-14 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC CFU DIQ (6ES7655-5PX31-1XX0)
Siemens / SIMATIC CFU DIQ (6ES7655-5PX31-1XX0)
|
6ES7655-5PX31-1XX0
|
vers:all/<V2.0.0 |
Mitigation
Vendor Fix
|
|
SIMATIC CFU PA (6ES7655-5PX11-0XX0)
Siemens / SIMATIC CFU PA (6ES7655-5PX11-0XX0)
|
6ES7655-5PX11-0XX0
|
vers:all/<V2.0.0 |
Mitigation
Vendor Fix
|
|
SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)
Siemens / SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)
|
6ES7157-1AB00-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)
Siemens / SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)
|
6ES7155-5AA00-0AC0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)
Siemens / SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)
|
6ES7154-8AB01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)
Siemens / SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)
|
6ES7154-8FB01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)
Siemens / SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)
|
6ES7154-8FX00-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)
Siemens / SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)
|
6ES7151-8AB01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)
Siemens / SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)
|
6ES7151-8FB01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0)
Siemens / SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0)
|
6ES7155-6MU00-0CN0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)
Siemens / SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)
Siemens / SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)
|
6ES7155-6AU00-0CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0)
Siemens / SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0)
|
6ES7155-6AU01-0CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0)
Siemens / SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0)
|
6ES7155-6AU30-0CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0)
Siemens / SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0)
|
6ES7144-6JF00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0)
Siemens / SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0)
|
6ES7148-6JE00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0)
Siemens / SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0)
|
6ES7148-6JG00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0)
Siemens / SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0)
|
6ES7148-6JJ00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0)
Siemens / SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0)
|
6ES7141-6BH00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0)
Siemens / SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0)
|
6ES7141-6BG00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0)
Siemens / SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0)
|
6ES7143-6BH00-0BB0
|
vers:all/>=V5.1.1|<V5.1.3 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0)
Siemens / SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0)
|
6ES7142-6BG00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0)
Siemens / SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0)
|
6ES7142-6BR00-0BB0
|
vers:all/>=V5.1.1|<V5.1.2 |
Mitigation
Vendor Fix
|
|
SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0)
Siemens / SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0)
|
6ES7158-3MU10-0XA0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0)
Siemens / SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0)
|
6ES7158-3AD10-0XA0
|
vers:all/>=4.2 |
Mitigation
No Fix Planned
|
|
SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
Siemens / SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
|
vers:all/<V2.0.0 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)
Siemens / SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)
|
6ES7314-6EH04-0AB0
|
vers:all/<V3.3.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)
Siemens / SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)
|
6ES7315-2EH14-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)
Siemens / SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)
|
6ES7315-2FJ14-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)
Siemens / SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)
|
6ES7315-7TJ10-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)
Siemens / SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)
|
6ES7317-2EK14-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)
Siemens / SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)
|
6ES7317-2FK14-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)
Siemens / SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)
|
6ES7317-7TK10-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)
Siemens / SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)
|
6ES7317-7UL10-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)
Siemens / SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)
|
6ES7318-3EL01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)
Siemens / SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)
|
6ES7318-3FL01-0AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0)
Siemens / SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0)
|
6ES7412-2EK07-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0)
Siemens / SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0)
|
6ES7414-3EM07-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0)
Siemens / SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0)
|
6ES7414-3FM07-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0)
Siemens / SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0)
|
6ES7416-3ES07-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0)
Siemens / SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0)
|
6ES7416-3FS07-0AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)
Siemens / SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)
|
vers:all/<V6.0.10 |
Mitigation
Vendor Fix
|
|
|
SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)
Siemens / SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)
|
vers:all/<V10.1.1 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)
Siemens / SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)
|
vers:all/<V8.2.3 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC TDC CP51M1
Siemens / SIMATIC TDC CP51M1
|
vers:all/<V1.1.10 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC TDC CPU555
Siemens / SIMATIC TDC CPU555
|
vers:all/<V1.2.1 |
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)
Siemens / SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)
|
6ES7671-0RC08-0YA0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)
Siemens / SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)
|
6ES7671-1RC08-0YA0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SINAMICS DCM
Siemens / SINAMICS DCM
|
All versions < V1.5 SP1 with Ethernet interface |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS G110M
Siemens / SINAMICS G110M
|
vers:all/<V4.7.14 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS G115D
Siemens / SINAMICS G115D
|
vers:all/<V4.7.14 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS G120 (incl. SIPLUS variants)
Siemens / SINAMICS G120 (incl. SIPLUS variants)
|
All versions < V4.7 SP14 with Ethernet interface |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS G130
Siemens / SINAMICS G130
|
vers:all/<V5.2.3.13 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS G150
Siemens / SINAMICS G150
|
vers:all/<V5.2.3.13 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS S110
Siemens / SINAMICS S110
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
SINAMICS S120 (incl. SIPLUS variants)
Siemens / SINAMICS S120 (incl. SIPLUS variants)
|
All versions < V5.2 SP3 HF13 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS S150
Siemens / SINAMICS S150
|
vers:all/<V5.2.3.13 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS S210 (6SL5...)
Siemens / SINAMICS S210 (6SL5...)
|
All versions < V5.2 SP3 HF18 |
Mitigation
Vendor Fix
fix
|
|
|
SINAMICS V90
Siemens / SINAMICS V90
|
vers:all/<V1.04.04 |
Mitigation
Vendor Fix
fix
|
|
|
SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)
Siemens / SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)
|
6AG1155-5AA00-2AC0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)
Siemens / SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)
|
6AG1155-5AA00-7AC0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)
Siemens / SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)
|
6AG2155-5AA00-1AC0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)
Siemens / SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)
|
6AG1151-8AB01-7AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)
Siemens / SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)
|
6AG1151-8FB01-2AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)
|
6AG1155-6AU00-2CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)
|
6AG1155-6AU00-4CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0)
|
6AG1155-6AU01-2CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0)
|
6AG1155-6AU01-7CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)
|
6AG2155-6AU00-1CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0)
|
6AG2155-6AU01-1CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0)
Siemens / SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0)
|
6AG2155-6AU01-4CN0
|
vers:all/>=V4.2.0 |
Mitigation
No Fix Planned
|
|
SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0)
Siemens / SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0)
|
6BK1942-1AA00-0AA0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1)
Siemens / SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1)
|
6BK1942-1AA00-0AA1
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0)
Siemens / SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0)
|
6BK1943-1AA00-0AA0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0)
Siemens / SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0)
|
6AG2158-3AD10-4XA0
|
vers:all/>=4.2 |
Mitigation
No Fix Planned
|
|
SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)
Siemens / SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)
|
6AG1314-6EH04-7AB0
|
vers:all/<V3.3.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)
Siemens / SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)
|
6AG1315-2EH14-7AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)
Siemens / SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)
|
6AG1315-2FJ14-2AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)
Siemens / SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)
|
6AG1317-2EK14-7AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)
Siemens / SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)
|
6AG1317-2FK14-2AB0
|
vers:all/<V3.2.19 |
Mitigation
Vendor Fix
fix
|
|
SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0)
Siemens / SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0)
|
6AG1414-3EM07-7AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
|
SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0)
Siemens / SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0)
|
6AG1416-3ES07-7AB0
|
vers:all/* |
Mitigation
No Fix Planned
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, contains a vulnerability that could allow an attacker to cause a denial of service condition on affected industrial products.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-446448: Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
},
{
"category": "self",
"summary": "SSA-446448: Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-446448.json"
}
],
"title": "SSA-446448: Denial of Service Vulnerability in PROFINET Stack Integrated on Interniche Stack",
"tracking": {
"current_release_date": "2025-01-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-446448",
"initial_release_date": "2022-04-12T00:00:00Z",
"revision_history": [
{
"date": "2022-04-12T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2022-06-14T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added ET200SP/MP/AL/EcoPN, PN/xx Coupler, SIPLUS HCS4x00 and SINAMICS products to the list of affected products"
},
{
"date": "2022-07-12T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added SINAMICS S110/V90/DCM products to the list of affected products. Additional details added to SINAMICS affected versions"
},
{
"date": "2022-08-09T00:00:00Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added fix for SIMATIC S7-410 CPU family"
},
{
"date": "2022-10-11T00:00:00Z",
"legacy_version": "1.4",
"number": "5",
"summary": "Added fix for SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants); removed SIMIT Simulation Platform as not affected"
},
{
"date": "2022-12-13T00:00:00Z",
"legacy_version": "1.5",
"number": "6",
"summary": "Added fix for SIMATIC S7-410 V10 CPU family and SIMATIC TDC"
},
{
"date": "2023-01-10T00:00:00Z",
"legacy_version": "1.6",
"number": "7",
"summary": "No fix planned for SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), added fix for SINAMICS S120 (incl. SIPLUS variants)"
},
{
"date": "2023-02-14T00:00:00Z",
"legacy_version": "1.7",
"number": "8",
"summary": "Added additional SIMATIC ET200ecoPN products (CM 4x IO-Link, M12-L / CM 8x IO-Link, M12-L / AI 8xRTD/TC, M12-L) to the list of affected products"
},
{
"date": "2023-04-11T00:00:00Z",
"legacy_version": "1.8",
"number": "9",
"summary": "Added fix for SINAMICS G130, G150, S150"
},
{
"date": "2023-07-11T00:00:00Z",
"legacy_version": "1.9",
"number": "10",
"summary": "Added fix for SINAMICS G110M, G115D, G120; Expanded SIMATIC S7-400 V7 CPU family to individual products and MLFBs; clarified that no fix is planned for SIMATIC S7-400 PN/DP V7 CPUs, while other S7-400 V7 CPUs are not affected"
},
{
"date": "2024-05-14T00:00:00Z",
"legacy_version": "2.0",
"number": "11",
"summary": "Added fix for several SIMATIC ET200ecoPN devices"
},
{
"date": "2024-06-11T00:00:00Z",
"legacy_version": "2.1",
"number": "12",
"summary": "Added fix for SINAMICS S210, SIMATIC CFU DIQ and SIMATIC CFU PA"
},
{
"date": "2024-07-09T00:00:00Z",
"legacy_version": "2.2",
"number": "13",
"summary": "Added fix for SINAMICS DCM and SINAMICS V90; clarified that no fix is planned for SINAMICS S110; listed affected products individually instead of product families (e.g., for SIMATIC ET 200AL/MP/SP/pro IM families); added affected SIPLUS devices (e.g., SIPLUS ET 200xx IM)"
},
{
"date": "2025-01-14T00:00:00Z",
"legacy_version": "2.3",
"number": "14",
"summary": "Added fix for SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0) and SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0)"
}
],
"status": "interim",
"version": "14"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.0.0",
"product": {
"name": "SIMATIC CFU DIQ (6ES7655-5PX31-1XX0)",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"6ES7655-5PX31-1XX0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC CFU DIQ (6ES7655-5PX31-1XX0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.0.0",
"product": {
"name": "SIMATIC CFU PA (6ES7655-5PX11-0XX0)",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"6ES7655-5PX11-0XX0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC CFU PA (6ES7655-5PX11-0XX0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0)",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"6ES7144-6JF00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0)",
"product_id": "4",
"product_identification_helper": {
"model_numbers": [
"6ES7148-6JE00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0)",
"product_id": "5",
"product_identification_helper": {
"model_numbers": [
"6ES7148-6JG00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0)",
"product_id": "6",
"product_identification_helper": {
"model_numbers": [
"6ES7148-6JJ00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0)",
"product_id": "7",
"product_identification_helper": {
"model_numbers": [
"6ES7141-6BG00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0)",
"product_id": "8",
"product_identification_helper": {
"model_numbers": [
"6ES7141-6BH00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.3",
"product": {
"name": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0)",
"product_id": "9",
"product_identification_helper": {
"model_numbers": [
"6ES7143-6BH00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0)",
"product_id": "10",
"product_identification_helper": {
"model_numbers": [
"6ES7142-6BG00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V5.1.1|\u003cV5.1.2",
"product": {
"name": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0)",
"product_id": "11",
"product_identification_helper": {
"model_numbers": [
"6ES7142-6BR00-0BB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)",
"product_id": "12",
"product_identification_helper": {
"model_numbers": [
"6ES7157-1AB00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)",
"product_id": "13",
"product_identification_helper": {
"model_numbers": [
"6ES7155-5AA00-0AC0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)",
"product_id": "14",
"product_identification_helper": {
"model_numbers": [
"6ES7154-8AB01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)",
"product_id": "15",
"product_identification_helper": {
"model_numbers": [
"6ES7154-8FB01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)",
"product_id": "16",
"product_identification_helper": {
"model_numbers": [
"6ES7154-8FX00-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)",
"product_id": "17",
"product_identification_helper": {
"model_numbers": [
"6ES7151-8AB01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)",
"product_id": "18",
"product_identification_helper": {
"model_numbers": [
"6ES7151-8FB01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0)",
"product_id": "19",
"product_identification_helper": {
"model_numbers": [
"6ES7155-6MU00-0CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
"product_id": "20"
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)",
"product_id": "21",
"product_identification_helper": {
"model_numbers": [
"6ES7155-6AU00-0CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0)",
"product_id": "22",
"product_identification_helper": {
"model_numbers": [
"6ES7155-6AU01-0CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0)",
"product_id": "23",
"product_identification_helper": {
"model_numbers": [
"6ES7155-6AU30-0CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0)",
"product_id": "24",
"product_identification_helper": {
"model_numbers": [
"6ES7158-3MU10-0XA0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=4.2",
"product": {
"name": "SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0)",
"product_id": "25",
"product_identification_helper": {
"model_numbers": [
"6ES7158-3AD10-0XA0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.3.19",
"product": {
"name": "SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)",
"product_id": "26",
"product_identification_helper": {
"model_numbers": [
"6ES7314-6EH04-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)",
"product_id": "27",
"product_identification_helper": {
"model_numbers": [
"6ES7315-2EH14-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)",
"product_id": "28",
"product_identification_helper": {
"model_numbers": [
"6ES7315-2FJ14-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)",
"product_id": "29",
"product_identification_helper": {
"model_numbers": [
"6ES7315-7TJ10-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)",
"product_id": "30",
"product_identification_helper": {
"model_numbers": [
"6ES7317-2EK14-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)",
"product_id": "31",
"product_identification_helper": {
"model_numbers": [
"6ES7317-2FK14-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)",
"product_id": "32",
"product_identification_helper": {
"model_numbers": [
"6ES7317-7TK10-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)",
"product_id": "33",
"product_identification_helper": {
"model_numbers": [
"6ES7317-7UL10-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)",
"product_id": "34",
"product_identification_helper": {
"model_numbers": [
"6ES7318-3EL01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)",
"product_id": "35",
"product_identification_helper": {
"model_numbers": [
"6ES7318-3FL01-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0)",
"product_id": "36",
"product_identification_helper": {
"model_numbers": [
"6ES7412-2EK07-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0)",
"product_id": "37",
"product_identification_helper": {
"model_numbers": [
"6ES7414-3EM07-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0)",
"product_id": "38",
"product_identification_helper": {
"model_numbers": [
"6ES7414-3FM07-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0)",
"product_id": "39",
"product_identification_helper": {
"model_numbers": [
"6ES7416-3ES07-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0)",
"product_id": "40",
"product_identification_helper": {
"model_numbers": [
"6ES7416-3FS07-0AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV6.0.10",
"product": {
"name": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"product_id": "41"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV8.2.3",
"product": {
"name": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
"product_id": "42"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV10.1.1",
"product": {
"name": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)",
"product_id": "43"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2.0.0",
"product": {
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"product_id": "44"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV1.1.10",
"product": {
"name": "SIMATIC TDC CP51M1",
"product_id": "45"
}
}
],
"category": "product_name",
"name": "SIMATIC TDC CP51M1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV1.2.1",
"product": {
"name": "SIMATIC TDC CPU555",
"product_id": "46"
}
}
],
"category": "product_name",
"name": "SIMATIC TDC CPU555"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)",
"product_id": "47",
"product_identification_helper": {
"model_numbers": [
"6ES7671-0RC08-0YA0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)",
"product_id": "48",
"product_identification_helper": {
"model_numbers": [
"6ES7671-1RC08-0YA0"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V1.5 SP1 with Ethernet interface",
"product": {
"name": "SINAMICS DCM",
"product_id": "49"
}
}
],
"category": "product_name",
"name": "SINAMICS DCM"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV4.7.14",
"product": {
"name": "SINAMICS G110M",
"product_id": "50"
}
}
],
"category": "product_name",
"name": "SINAMICS G110M"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV4.7.14",
"product": {
"name": "SINAMICS G115D",
"product_id": "51"
}
}
],
"category": "product_name",
"name": "SINAMICS G115D"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V4.7 SP14 with Ethernet interface",
"product": {
"name": "SINAMICS G120 (incl. SIPLUS variants)",
"product_id": "52"
}
}
],
"category": "product_name",
"name": "SINAMICS G120 (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.2.3.13",
"product": {
"name": "SINAMICS G130",
"product_id": "53"
}
}
],
"category": "product_name",
"name": "SINAMICS G130"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.2.3.13",
"product": {
"name": "SINAMICS G150",
"product_id": "54"
}
}
],
"category": "product_name",
"name": "SINAMICS G150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS S110",
"product_id": "55"
}
}
],
"category": "product_name",
"name": "SINAMICS S110"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V5.2 SP3 HF13",
"product": {
"name": "SINAMICS S120 (incl. SIPLUS variants)",
"product_id": "56"
}
}
],
"category": "product_name",
"name": "SINAMICS S120 (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.2.3.13",
"product": {
"name": "SINAMICS S150",
"product_id": "57"
}
}
],
"category": "product_name",
"name": "SINAMICS S150"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V5.2 SP3 HF18",
"product": {
"name": "SINAMICS S210 (6SL5...)",
"product_id": "58"
}
}
],
"category": "product_name",
"name": "SINAMICS S210 (6SL5...)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV1.04.04",
"product": {
"name": "SINAMICS V90",
"product_id": "59"
}
}
],
"category": "product_name",
"name": "SINAMICS V90"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)",
"product_id": "60",
"product_identification_helper": {
"model_numbers": [
"6AG1155-5AA00-2AC0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)",
"product_id": "61",
"product_identification_helper": {
"model_numbers": [
"6AG1155-5AA00-7AC0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)",
"product_id": "62",
"product_identification_helper": {
"model_numbers": [
"6AG2155-5AA00-1AC0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)",
"product_id": "63",
"product_identification_helper": {
"model_numbers": [
"6AG1151-8AB01-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)",
"product_id": "64",
"product_identification_helper": {
"model_numbers": [
"6AG1151-8FB01-2AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)",
"product_id": "65",
"product_identification_helper": {
"model_numbers": [
"6AG1155-6AU00-2CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)",
"product_id": "66",
"product_identification_helper": {
"model_numbers": [
"6AG1155-6AU00-4CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0)",
"product_id": "67",
"product_identification_helper": {
"model_numbers": [
"6AG1155-6AU01-2CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0)",
"product_id": "68",
"product_identification_helper": {
"model_numbers": [
"6AG1155-6AU01-7CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)",
"product_id": "69",
"product_identification_helper": {
"model_numbers": [
"6AG2155-6AU00-1CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0)",
"product_id": "70",
"product_identification_helper": {
"model_numbers": [
"6AG2155-6AU01-1CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=V4.2.0",
"product": {
"name": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0)",
"product_id": "71",
"product_identification_helper": {
"model_numbers": [
"6AG2155-6AU01-4CN0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0)",
"product_id": "72",
"product_identification_helper": {
"model_numbers": [
"6BK1942-1AA00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1)",
"product_id": "73",
"product_identification_helper": {
"model_numbers": [
"6BK1942-1AA00-0AA1"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0)",
"product_id": "74",
"product_identification_helper": {
"model_numbers": [
"6BK1943-1AA00-0AA0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003e=4.2",
"product": {
"name": "SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0)",
"product_id": "75",
"product_identification_helper": {
"model_numbers": [
"6AG2158-3AD10-4XA0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.3.19",
"product": {
"name": "SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)",
"product_id": "76",
"product_identification_helper": {
"model_numbers": [
"6AG1314-6EH04-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)",
"product_id": "77",
"product_identification_helper": {
"model_numbers": [
"6AG1315-2EH14-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)",
"product_id": "78",
"product_identification_helper": {
"model_numbers": [
"6AG1315-2FJ14-2AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)",
"product_id": "79",
"product_identification_helper": {
"model_numbers": [
"6AG1317-2EK14-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV3.2.19",
"product": {
"name": "SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)",
"product_id": "80",
"product_identification_helper": {
"model_numbers": [
"6AG1317-2FK14-2AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0)",
"product_id": "81",
"product_identification_helper": {
"model_numbers": [
"6AG1414-3EM07-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0)",
"product_id": "82",
"product_identification_helper": {
"model_numbers": [
"6AG1416-3ES07-7AB0"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-25622",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"3",
"4",
"5",
"6",
"8",
"7",
"9",
"10",
"11",
"24",
"25",
"44",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"43",
"42",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Limit access to port 102/tcp to trusted users and systems only",
"product_ids": [
"1",
"2",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"3",
"4",
"5",
"6",
"8",
"7",
"9",
"10",
"11",
"24",
"25",
"44",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"43",
"42",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"12",
"13",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"36",
"37",
"38",
"39",
"40",
"47",
"48",
"55",
"60",
"61",
"62",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"81",
"82"
]
},
{
"category": "vendor_fix",
"details": "Update to V1.04.04 or later version",
"product_ids": [
"59"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109746210/"
},
{
"category": "vendor_fix",
"details": "Update to V1.1.10 or later version",
"product_ids": [
"45"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/27049282/"
},
{
"category": "vendor_fix",
"details": "Update to V1.2.1 or later version",
"product_ids": [
"46"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109740119/"
},
{
"category": "vendor_fix",
"details": "Update to V1.5 SP1 or later version",
"product_ids": [
"49"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/44029688/"
},
{
"category": "vendor_fix",
"details": "Update to V2.0.0 or later version",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V4.7.14 or later version",
"product_ids": [
"50",
"51"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817231/"
},
{
"category": "vendor_fix",
"details": "Update to V4.7 SP14 or later version",
"product_ids": [
"52"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817231/"
},
{
"category": "vendor_fix",
"details": "Update to V5.1.2 or later version",
"product_ids": [
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.1.2 or later version",
"product_ids": [
"3",
"8",
"7",
"10",
"11"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.1.2 or later version",
"product_ids": [
"4"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.1.2 or later version",
"product_ids": [
"6"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.1.3 or later version",
"product_ids": [
"9"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.2 SP3 HF13 or later version",
"product_ids": [
"56"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109780844/"
},
{
"category": "vendor_fix",
"details": "Update to V5.2.3.13 or later version",
"product_ids": [
"53",
"54",
"57"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109764679/"
},
{
"category": "vendor_fix",
"details": "Update to V5.2 SP3 HF18 or later version",
"product_ids": [
"58"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109945645/"
},
{
"category": "vendor_fix",
"details": "Update to V6.0.10 or later version",
"product_ids": [
"41"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.2.3 or later version",
"product_ids": [
"42"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109476571/"
},
{
"category": "vendor_fix",
"details": "Update to V2.0.0 or later version",
"product_ids": [
"44"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109478459/"
},
{
"category": "vendor_fix",
"details": "Update to V10.1.1 or later version",
"product_ids": [
"43"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109773044/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"27",
"77"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/40360647/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"30",
"79"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/40362228/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"34"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/44442927/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"35"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/44443101/"
},
{
"category": "vendor_fix",
"details": "Update to V3.3.19 or later version",
"product_ids": [
"26",
"76"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/51466769/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"28",
"78"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/40944925/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"31",
"80"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/40945128/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"32"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/85059804/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"29"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/85049260/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"33"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/85063017/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"17",
"63"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/47353723/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"18",
"64"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/47354354/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"14"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/47354502/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"15"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/47354578/"
},
{
"category": "vendor_fix",
"details": "Update to V3.2.19 or later version",
"product_ids": [
"16"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/62612377/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"3",
"4",
"5",
"6",
"8",
"7",
"9",
"10",
"11",
"24",
"25",
"44",
"26",
"27",
"28",
"29",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"38",
"39",
"40",
"41",
"43",
"42",
"45",
"46",
"47",
"48",
"49",
"50",
"51",
"52",
"53",
"54",
"55",
"56",
"57",
"58",
"59",
"60",
"61",
"62",
"63",
"64",
"65",
"66",
"67",
"68",
"69",
"70",
"71",
"72",
"73",
"74",
"75",
"76",
"77",
"78",
"79",
"80",
"81",
"82"
]
}
],
"title": "CVE-2022-25622"
}
]
}
VAR-202204-0684
Vulnerability from variot - Updated: 2024-06-11 22:49A vulnerability has been identified in SIMATIC CFU DIQ (6ES7655-5PX31-1XX0), SIMATIC CFU PA (6ES7655-5PX11-0XX0), SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0), SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0), SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. SIPLUS variants), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. SIPLUS variants), SINAMICS S150, SINAMICS S210 (6SL5...), SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0), SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1), SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0), SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0), SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0). The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.
This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments. simatic cfu diq firmware, SIMATIC CFU PA firmware, SIMATIC S7-300 CPU Multiple Siemens products such as firmware contain a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state. The SIMATIC S7-400 CPU family is designed for process control in industrial environments. The SIMATIC S7-300 CPU family is designed for discrete and continuous control in industrial environments. The SIMATIC S7-1500 CPU family is designed for discrete and continuous control in industrial environments. The SIMATIC Compact Field Unit (SIMATIC CFU) is an intelligent field distributor. The SIMATIC ET 200 interface module is used to connect field devices (IO devices) to the controller via PROFINET. SIMATIC TDC is a multiprocessor automation system for drive, control and technical tasks. SIMATIC WinAC RTX is the SIMATIC software controller for PC-based automation solutions. SIPLUSextreme products are designed for reliable operation under extreme conditions. The SIMIT Simulation Platform allows the simulation of plant setups to predict failures at an early planning stage.
A denial of service vulnerability exists in Siemens PROFINET Stack Integrated on Interniche Stack. A vulnerability has been identified in SIMATIC CFU DIQ (All versions), SIMATIC CFU PA (All versions), SIMATIC S7-1500 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (All versions), SIMIT Simulation Platform (All versions)
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202204-0684",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic s7-1500 cpu",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2.0.0"
},
{
"model": "simatic tdc cpu555",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic cfu diq",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic s7-410 v10",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic cfu pa",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic tdc cp51m1",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic s7-300 cpu",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simit simulation platform",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic winac rtx",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic s7-410 v8",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic s7-400h v6",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic s7-400 pn\\/dp v7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic s7-410 v10",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic cfu diq",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-400 pn/dp v7",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-1500 cpu",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-410 v8",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic cfu pa",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-300 cpu",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic tdc cp51m1",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic tdc cpu555",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-400h v6",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simit simulation platform",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic winac rtx",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-300 cpu family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic s7-1500 cpu family",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic tdc cp51m1",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic tdc cpu555",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simit simulation platform",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic cfu diq",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic cfu pa",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic s7-400 h cpu family",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v6\u003c6.0.10"
},
{
"model": "simatic s7-400 pn/dp cpu family",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v7"
},
{
"model": "simatic s7-410 cpu family",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v8"
},
{
"model": "simatic s7-410 cpu family",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v10"
},
{
"model": "simatic winac rtx",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28496"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-008398"
},
{
"db": "NVD",
"id": "CVE-2022-25622"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_cfu_diq_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_cfu_diq:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v7_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp_v7:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-410_v10_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-410_v10:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simit_simulation_platform:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-25622"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens reported this vulnerability to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-2940"
}
],
"trust": 0.6
},
"cve": "CVE-2022-25622",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.0,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-25622",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-28496",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-25622",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-25622",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2022-25622",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2022-28496",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202204-2940",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2022-25622",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28496"
},
{
"db": "VULMON",
"id": "CVE-2022-25622"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-008398"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2940"
},
{
"db": "NVD",
"id": "CVE-2022-25622"
},
{
"db": "NVD",
"id": "CVE-2022-25622"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC CFU DIQ (6ES7655-5PX31-1XX0), SIMATIC CFU PA (6ES7655-5PX11-0XX0), SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0), SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES7414-3FM07-0AB0), SIMATIC S7-400 CPU 416-3 PN/DP V7 (6ES7416-3ES07-0AB0), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (6ES7416-3FS07-0AB0), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. SIPLUS variants), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. SIPLUS variants), SINAMICS S150, SINAMICS S210 (6SL5...), SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS HCS4200 CIM4210 (6BK1942-1AA00-0AA0), SIPLUS HCS4200 CIM4210C (6BK1942-1AA00-0AA1), SIPLUS HCS4300 CIM4310 (6BK1943-1AA00-0AA0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0), SIPLUS S7-400 CPU 414-3 PN/DP V7 (6AG1414-3EM07-7AB0), SIPLUS S7-400 CPU 416-3 PN/DP V7 (6AG1416-3ES07-7AB0). The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. \n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments. simatic cfu diq firmware, SIMATIC CFU PA firmware, SIMATIC S7-300 CPU Multiple Siemens products such as firmware contain a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state. The SIMATIC S7-400 CPU family is designed for process control in industrial environments. The SIMATIC S7-300 CPU family is designed for discrete and continuous control in industrial environments. The SIMATIC S7-1500 CPU family is designed for discrete and continuous control in industrial environments. The SIMATIC Compact Field Unit (SIMATIC CFU) is an intelligent field distributor. The SIMATIC ET 200 interface module is used to connect field devices (IO devices) to the controller via PROFINET. SIMATIC TDC is a multiprocessor automation system for drive, control and technical tasks. SIMATIC WinAC RTX is the SIMATIC software controller for PC-based automation solutions. SIPLUSextreme products are designed for reliable operation under extreme conditions. The SIMIT Simulation Platform allows the simulation of plant setups to predict failures at an early planning stage. \n\r\n\r\nA denial of service vulnerability exists in Siemens PROFINET Stack Integrated on Interniche Stack. A vulnerability has been identified in SIMATIC CFU DIQ (All versions), SIMATIC CFU PA (All versions), SIMATIC S7-1500 CPU family (incl. SIPLUS variants) (All versions), SIMATIC TDC CP51M1 (All versions), SIMATIC TDC CPU555 (All versions), SIMATIC WinAC RTX (All versions), SIMIT Simulation Platform (All versions)",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-25622"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-008398"
},
{
"db": "CNVD",
"id": "CNVD-2022-28496"
},
{
"db": "VULMON",
"id": "CVE-2022-25622"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-25622",
"trust": 3.9
},
{
"db": "SIEMENS",
"id": "SSA-446448",
"trust": 3.1
},
{
"db": "ICS CERT",
"id": "ICSA-22-104-06",
"trust": 1.5
},
{
"db": "JVN",
"id": "JVNVU91165555",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-008398",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-28496",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2022.1713",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2022042008",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2940",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-25622",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28496"
},
{
"db": "VULMON",
"id": "CVE-2022-25622"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-008398"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2940"
},
{
"db": "NVD",
"id": "CVE-2022-25622"
}
]
},
"id": "VAR-202204-0684",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28496"
}
],
"trust": 1.3449991391666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28496"
}
]
},
"last_update_date": "2024-06-11T22:49:09.624000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens PROFINET Stack Integrated on Interniche Stack Denial of Service Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/329201"
},
{
"title": "Multiple Siemens SIMATIC Product resource management error vulnerability fixes",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=245481"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28496"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2940"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-400",
"trust": 1.0
},
{
"problemtype": "Resource exhaustion (CWE-400) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-008398"
},
{
"db": "NVD",
"id": "CVE-2022-25622"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91165555/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-25622"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-06"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/simatic-denial-of-service-via-profinet-interniche-ip-stack-38018"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-06"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-25622/"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2022.1713"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022042008"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/400.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-06"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-28496"
},
{
"db": "VULMON",
"id": "CVE-2022-25622"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-008398"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2940"
},
{
"db": "NVD",
"id": "CVE-2022-25622"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-28496"
},
{
"db": "VULMON",
"id": "CVE-2022-25622"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-008398"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2940"
},
{
"db": "NVD",
"id": "CVE-2022-25622"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-28496"
},
{
"date": "2022-04-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-25622"
},
{
"date": "2023-07-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-008398"
},
{
"date": "2022-04-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-2940"
},
{
"date": "2022-04-12T09:15:14.483000",
"db": "NVD",
"id": "CVE-2022-25622"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-28496"
},
{
"date": "2022-04-22T00:00:00",
"db": "VULMON",
"id": "CVE-2022-25622"
},
{
"date": "2023-07-26T08:25:00",
"db": "JVNDB",
"id": "JVNDB-2022-008398"
},
{
"date": "2023-07-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-2940"
},
{
"date": "2024-06-11T09:15:10.623000",
"db": "NVD",
"id": "CVE-2022-25622"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-2940"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Resource Exhaustion Vulnerability in Multiple Siemens Products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-008398"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "resource management error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-2940"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.