Summary
A stack overflow vulnerability exists in the upnpd service in Netgear EX6100v1 201.0.2.28, CAX80 2.1.2.6, and DC112A 1.0.0.62, which may lead to the execution of arbitrary code without authentication.
References
{ containers: { adp: [ { providerMetadata: { dateUpdated: "2024-08-03T04:13:57.024Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://www.netgear.com/about/security/", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://kb.netgear.com/000064615/Security-Advisory-for-Pre-Authentication-Command-Injection-on-EX6100v1-and-Pre-Authentication-Stack-Overflow-on-Multiple-Products-PSV-2021-0282-PSV-2021-0288", }, { tags: [ "x_refsource_MISC", "x_transferred", ], url: "https://github.com/doudoudedi/Netgear_product_stack_overflow/blob/main/NETGEAR%20EX%20series%20upnpd%20stack_overflow.md", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { product: "n/a", vendor: "n/a", versions: [ { status: "affected", version: "n/a", }, ], }, ], descriptions: [ { lang: "en", value: "A stack overflow vulnerability exists in the upnpd service in Netgear EX6100v1 201.0.2.28, CAX80 2.1.2.6, and DC112A 1.0.0.62, which may lead to the execution of arbitrary code without authentication.", }, ], problemTypes: [ { descriptions: [ { description: "n/a", lang: "en", type: "text", }, ], }, ], providerMetadata: { dateUpdated: "2022-03-18T10:12:57", orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca", shortName: "mitre", }, references: [ { tags: [ "x_refsource_MISC", ], url: "https://www.netgear.com/about/security/", }, { tags: [ "x_refsource_MISC", ], url: "https://kb.netgear.com/000064615/Security-Advisory-for-Pre-Authentication-Command-Injection-on-EX6100v1-and-Pre-Authentication-Stack-Overflow-on-Multiple-Products-PSV-2021-0282-PSV-2021-0288", }, { tags: [ "x_refsource_MISC", ], url: "https://github.com/doudoudedi/Netgear_product_stack_overflow/blob/main/NETGEAR%20EX%20series%20upnpd%20stack_overflow.md", }, ], x_legacyV4Record: { CVE_data_meta: { ASSIGNER: "cve@mitre.org", ID: "CVE-2022-24655", STATE: "PUBLIC", }, affects: { vendor: { vendor_data: [ { product: { product_data: [ { product_name: "n/a", version: { version_data: [ { version_value: "n/a", }, ], }, }, ], }, vendor_name: "n/a", }, ], }, }, data_format: "MITRE", data_type: "CVE", data_version: "4.0", description: { description_data: [ { lang: "eng", value: "A stack overflow vulnerability exists in the upnpd service in Netgear EX6100v1 201.0.2.28, CAX80 2.1.2.6, and DC112A 1.0.0.62, which may lead to the execution of arbitrary code without authentication.", }, ], }, problemtype: { problemtype_data: [ { description: [ { lang: "eng", value: "n/a", }, ], }, ], }, references: { reference_data: [ { name: "https://www.netgear.com/about/security/", refsource: "MISC", url: "https://www.netgear.com/about/security/", }, { name: "https://kb.netgear.com/000064615/Security-Advisory-for-Pre-Authentication-Command-Injection-on-EX6100v1-and-Pre-Authentication-Stack-Overflow-on-Multiple-Products-PSV-2021-0282-PSV-2021-0288", refsource: "MISC", url: "https://kb.netgear.com/000064615/Security-Advisory-for-Pre-Authentication-Command-Injection-on-EX6100v1-and-Pre-Authentication-Stack-Overflow-on-Multiple-Products-PSV-2021-0282-PSV-2021-0288", }, { name: "https://github.com/doudoudedi/Netgear_product_stack_overflow/blob/main/NETGEAR%20EX%20series%20upnpd%20stack_overflow.md", refsource: "MISC", url: "https://github.com/doudoudedi/Netgear_product_stack_overflow/blob/main/NETGEAR%20EX%20series%20upnpd%20stack_overflow.md", }, ], }, }, }, }, cveMetadata: { assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca", assignerShortName: "mitre", cveId: "CVE-2022-24655", datePublished: "2022-03-18T10:12:57", dateReserved: "2022-02-07T00:00:00", dateUpdated: "2024-08-03T04:13:57.024Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { nvd: "{\"cve\":{\"id\":\"CVE-2022-24655\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-03-18T11:15:08.010\",\"lastModified\":\"2024-11-21T06:50:48.120\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A stack overflow vulnerability exists in the upnpd service in Netgear EX6100v1 201.0.2.28, CAX80 2.1.2.6, and DC112A 1.0.0.62, which may lead to the execution of arbitrary code without authentication.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad de desbordamiento de pila en el servicio upnpd de Netgear EX6100v1 versión 201.0.2.28, CAX80 versión 2.1.2.6 y DC112A versión 1.0.0.62, que puede conllevar a una ejecución de código arbitrario sin autenticación\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6100_firmware:201.0.2.28:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"37A39F3F-B85E-4BB3-BA63-5CB0602F5550\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AB84CD03-765C-4D4F-A176-364F8E72A4E7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A858641D-FD51-4A0C-B09B-A72DA47B6961\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3186CC67-B567-4A0C-BD2C-0433716FBD1B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:cax80_firmware:2.1.2.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"28C36F9E-A167-4D47-9146-BE00629E2549\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:cax80:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"673A83EA-E359-4629-8B20-5382C15260B2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:dc112a_firmware:1.0.0.62:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8421345C-55A1-49B3-9A2F-B9D231BBBE4C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F87FFC46-137D-45B8-B437-F15565FB33D0\"}]}]}],\"references\":[{\"url\":\"https://github.com/doudoudedi/Netgear_product_stack_overflow/blob/main/NETGEAR%20EX%20series%20upnpd%20stack_overflow.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://kb.netgear.com/000064615/Security-Advisory-for-Pre-Authentication-Command-Injection-on-EX6100v1-and-Pre-Authentication-Stack-Overflow-on-Multiple-Products-PSV-2021-0282-PSV-2021-0288\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.netgear.com/about/security/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://github.com/doudoudedi/Netgear_product_stack_overflow/blob/main/NETGEAR%20EX%20series%20upnpd%20stack_overflow.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://kb.netgear.com/000064615/Security-Advisory-for-Pre-Authentication-Command-Injection-on-EX6100v1-and-Pre-Authentication-Stack-Overflow-on-Multiple-Products-PSV-2021-0282-PSV-2021-0288\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.netgear.com/about/security/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.