Summary
A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window.
Severity
7.3 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-02 13:48 UTC
CWE
- Insecure GUI
- CWE-317 - Cleartext Storage of Sensitive Information in GUI
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://support.lenovo.com/us/en/product_security… | x_refsource_MISC |
| https://www.infosec.tirol/cve-2022-0354/ | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Lenovo | System Update |
Affected:
various
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T23:25:40.291Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.infosec.tirol/cve-2022-0354/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-0354",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T13:48:54.060069Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-317",
"description": "CWE-317 Cleartext Storage of Sensitive Information in GUI",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T13:50:02.923Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "System Update",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Daniel Feichter (@VirtualAllocEx) at Infosec Tirol for reporting this issue."
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Insecure GUI",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-26T22:24:43.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.infosec.tirol/cve-2022-0354/"
}
],
"solutions": [
{
"lang": "en",
"value": "Follow Mitigation Strategy in LEN-76673."
}
],
"source": {
"advisory": "LEN-76673",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2022-0354",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "System Update",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "various"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Daniel Feichter (@VirtualAllocEx) at Infosec Tirol for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Insecure GUI"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-76673",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
},
{
"name": "https://www.infosec.tirol/cve-2022-0354/",
"refsource": "MISC",
"url": "https://www.infosec.tirol/cve-2022-0354/"
}
]
},
"solution": [
{
"lang": "en",
"value": "Follow Mitigation Strategy in LEN-76673."
}
],
"source": {
"advisory": "LEN-76673",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2022-0354",
"datePublished": "2022-04-22T20:30:47.000Z",
"dateReserved": "2022-01-24T00:00:00.000Z",
"dateUpdated": "2026-06-02T13:50:02.923Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-0354",
"date": "2026-09-18",
"epss": "0.00256",
"percentile": "0.17535"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:lenovo:system_update:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3BD6ED86-7797-4773-BC46-6A7190811322",
"versionEndExcluding": "2022-02-25",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."
},
{
"lang": "es",
"value": "Se ha informado de una vulnerabilidad en Lenovo System Update que podr\u00eda permitir a un usuario local con acceso interactivo al sistema la capacidad de ejecutar c\u00f3digo con altos privilegios s\u00f3lo durante la instalaci\u00f3n de un paquete de System Update publicado antes del 25-02-2022, que muestra una ventana de s\u00edmbolo del sistema"
}
],
"id": "CVE-2022-0354",
"lastModified": "2024-11-21T06:38:26.727",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.3,
"impactScore": 5.9,
"source": "psirt@lenovo.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-22T21:15:10.187",
"references": [
{
"source": "psirt@lenovo.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
},
{
"source": "psirt@lenovo.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.infosec.tirol/cve-2022-0354/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.infosec.tirol/cve-2022-0354/"
}
],
"sourceIdentifier": "psirt@lenovo.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"product": "System Update",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"source": "psirt@lenovo.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:lenovo:system_update:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3BD6ED86-7797-4773-BC46-6A7190811322",
"versionEndExcluding": "2022-02-25",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."
},
{
"lang": "es",
"value": "Se ha informado de una vulnerabilidad en Lenovo System Update que podr\u00eda permitir a un usuario local con acceso interactivo al sistema la capacidad de ejecutar c\u00f3digo con altos privilegios s\u00f3lo durante la instalaci\u00f3n de un paquete de System Update publicado antes del 25-02-2022, que muestra una ventana de s\u00edmbolo del sistema"
}
],
"id": "CVE-2022-0354",
"lastModified": "2026-06-17T04:20:26.943",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.3,
"impactScore": 5.9,
"source": "psirt@lenovo.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-0354",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T13:48:54.060069Z",
"version": "2.0.3"
}
}
]
},
"published": "2022-04-22T21:15:10.187",
"references": [
{
"source": "psirt@lenovo.com",
"tags": [
"Vendor Advisory"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
},
{
"source": "psirt@lenovo.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.infosec.tirol/cve-2022-0354/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.infosec.tirol/cve-2022-0354/"
}
],
"sourceIdentifier": "psirt@lenovo.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-317"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T23:25:40.291Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.infosec.tirol/cve-2022-0354/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-0354",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T13:48:54.060069Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-317",
"description": "CWE-317 Cleartext Storage of Sensitive Information in GUI",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T13:49:58.840Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "System Update",
"vendor": "Lenovo",
"versions": [
{
"status": "affected",
"version": "various"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lenovo thanks Daniel Feichter (@VirtualAllocEx) at Infosec Tirol for reporting this issue."
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Insecure GUI",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-26T22:24:43.000Z",
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.infosec.tirol/cve-2022-0354/"
}
],
"solutions": [
{
"lang": "en",
"value": "Follow Mitigation Strategy in LEN-76673."
}
],
"source": {
"advisory": "LEN-76673",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@lenovo.com",
"ID": "CVE-2022-0354",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "System Update",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "various"
}
]
}
}
]
},
"vendor_name": "Lenovo"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lenovo thanks Daniel Feichter (@VirtualAllocEx) at Infosec Tirol for reporting this issue."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Insecure GUI"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.lenovo.com/us/en/product_security/LEN-76673",
"refsource": "MISC",
"url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
},
{
"name": "https://www.infosec.tirol/cve-2022-0354/",
"refsource": "MISC",
"url": "https://www.infosec.tirol/cve-2022-0354/"
}
]
},
"solution": [
{
"lang": "en",
"value": "Follow Mitigation Strategy in LEN-76673."
}
],
"source": {
"advisory": "LEN-76673",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"assignerShortName": "lenovo",
"cveId": "CVE-2022-0354",
"datePublished": "2022-04-22T20:30:47.000Z",
"dateReserved": "2022-01-24T00:00:00.000Z",
"dateUpdated": "2026-06-02T13:50:02.923Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…