CVE-2021-36178 (GCVE-0-2021-36178)
Vulnerability from cvelistv5
Published
2021-10-06 09:18
Modified
2024-10-25 13:49
CWE
  • Information disclosure
Summary
A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup.
Impacted products
Vendor Product Version
Fortinet Fortinet FortiSDNConnector Version: FortiSDNConnector 1.1.7, 1.1.6, 1.1.5, 1.1.4, 1.1.3, 1.1.2, 1.1.1, 1.1.0, 1.0.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:47:43.943Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://fortiguard.com/advisory/FG-IR-20-183"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-36178",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T13:58:14.516117Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-25T13:49:37.371Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Fortinet FortiSDNConnector",
          "vendor": "Fortinet",
          "versions": [
            {
              "status": "affected",
              "version": "FortiSDNConnector 1.1.7, 1.1.6, 1.1.5, 1.1.4, 1.1.3, 1.1.2, 1.1.1, 1.1.0, 1.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitCodeMaturity": "FUNCTIONAL",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "remediationLevel": "NOT_DEFINED",
            "reportConfidence": "NOT_DEFINED",
            "scope": "UNCHANGED",
            "temporalScore": 4.2,
            "temporalSeverity": "MEDIUM",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:F/RL:X/RC:X",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information disclosure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-10-06T09:18:12",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://fortiguard.com/advisory/FG-IR-20-183"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@fortinet.com",
          "ID": "CVE-2021-36178",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Fortinet FortiSDNConnector",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "FortiSDNConnector 1.1.7, 1.1.6, 1.1.5, 1.1.4, 1.1.3, 1.1.2, 1.1.1, 1.1.0, 1.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fortinet"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "availabilityImpact": "None",
            "baseScore": 4.2,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "integrityImpact": "None",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "userInteraction": "None",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:F/RL:X/RC:X",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information disclosure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://fortiguard.com/advisory/FG-IR-20-183",
              "refsource": "CONFIRM",
              "url": "https://fortiguard.com/advisory/FG-IR-20-183"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2021-36178",
    "datePublished": "2021-10-06T09:18:12",
    "dateReserved": "2021-07-06T00:00:00",
    "dateUpdated": "2024-10-25T13:49:37.371Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-36178\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2021-10-06T10:15:07.977\",\"lastModified\":\"2024-11-21T06:13:15.880\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup.\"},{\"lang\":\"es\",\"value\":\"Una protecci\u00f3n insuficiente de las credenciales en Fortinet FortiSDNConnector versi\u00f3n 1.1.7 y por debajo, permite a un atacante divulgar informaci\u00f3n de credenciales de dispositivos de terceros por medio de la b\u00fasqueda en la p\u00e1gina de configuraci\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-522\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortisdnconnector:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.1.8\",\"matchCriteriaId\":\"3AE6C99E-9DC8-411A-85A7-38FF390D0944\"}]}]}],\"references\":[{\"url\":\"https://fortiguard.com/advisory/FG-IR-20-183\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://fortiguard.com/advisory/FG-IR-20-183\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://fortiguard.com/advisory/FG-IR-20-183\", \"tags\": [\"x_refsource_CONFIRM\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T00:47:43.943Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2021-36178\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-23T13:58:14.516117Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-23T13:59:22.390Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:F/RL:X/RC:X\", \"temporalScore\": 4.2, \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"remediationLevel\": \"NOT_DEFINED\", \"reportConfidence\": \"NOT_DEFINED\", \"temporalSeverity\": \"MEDIUM\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"exploitCodeMaturity\": \"FUNCTIONAL\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Fortinet\", \"product\": \"Fortinet FortiSDNConnector\", \"versions\": [{\"status\": \"affected\", \"version\": \"FortiSDNConnector 1.1.7, 1.1.6, 1.1.5, 1.1.4, 1.1.3, 1.1.2, 1.1.1, 1.1.0, 1.0.0\"}]}], \"references\": [{\"url\": \"https://fortiguard.com/advisory/FG-IR-20-183\", \"tags\": [\"x_refsource_CONFIRM\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"Information disclosure\"}]}], \"providerMetadata\": {\"orgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"shortName\": \"fortinet\", \"dateUpdated\": \"2021-10-06T09:18:12\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"scope\": \"Unchanged\", \"version\": \"3.1\", \"baseScore\": 4.2, \"attackVector\": \"Network\", \"baseSeverity\": \"Medium\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:F/RL:X/RC:X\", \"integrityImpact\": \"None\", \"userInteraction\": \"None\", \"attackComplexity\": \"Low\", \"availabilityImpact\": \"None\", \"privilegesRequired\": \"Low\", \"confidentialityImpact\": \"Low\"}}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"FortiSDNConnector 1.1.7, 1.1.6, 1.1.5, 1.1.4, 1.1.3, 1.1.2, 1.1.1, 1.1.0, 1.0.0\"}]}, \"product_name\": \"Fortinet FortiSDNConnector\"}]}, \"vendor_name\": \"Fortinet\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://fortiguard.com/advisory/FG-IR-20-183\", \"name\": \"https://fortiguard.com/advisory/FG-IR-20-183\", \"refsource\": \"CONFIRM\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"Information disclosure\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2021-36178\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"psirt@fortinet.com\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2021-36178\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-25T13:49:37.371Z\", \"dateReserved\": \"2021-07-06T00:00:00\", \"assignerOrgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"datePublished\": \"2021-10-06T09:18:12\", \"assignerShortName\": \"fortinet\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…