GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2021-36178 (GCVE-0-2021-36178)

Vulnerability from cvelistv5 – Published: 2021-10-06 09:18 – Updated: 2024-10-25 13:49
VLAI
Summary
A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-23 13:58 UTC
CWE
  • Information disclosure
References
URL Tags
https://fortiguard.com/advisory/FG-IR-20-183 x_refsource_CONFIRM
Impacted products
Vendor Product Version CPE status
Fortinet Fortinet FortiSDNConnector Affected: FortiSDNConnector 1.1.7, 1.1.6, 1.1.5, 1.1.4, 1.1.3, 1.1.2, 1.1.1, 1.1.0, 1.0.0
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:47:43.943Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://fortiguard.com/advisory/FG-IR-20-183"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-36178",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T13:58:14.516117Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-25T13:49:37.371Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Fortinet FortiSDNConnector",
          "vendor": "Fortinet",
          "versions": [
            {
              "status": "affected",
              "version": "FortiSDNConnector 1.1.7, 1.1.6, 1.1.5, 1.1.4, 1.1.3, 1.1.2, 1.1.1, 1.1.0, 1.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitCodeMaturity": "FUNCTIONAL",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "remediationLevel": "NOT_DEFINED",
            "reportConfidence": "NOT_DEFINED",
            "scope": "UNCHANGED",
            "temporalScore": 4.2,
            "temporalSeverity": "MEDIUM",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:F/RL:X/RC:X",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Information disclosure",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-10-06T09:18:12.000Z",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://fortiguard.com/advisory/FG-IR-20-183"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@fortinet.com",
          "ID": "CVE-2021-36178",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Fortinet FortiSDNConnector",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "FortiSDNConnector 1.1.7, 1.1.6, 1.1.5, 1.1.4, 1.1.3, 1.1.2, 1.1.1, 1.1.0, 1.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fortinet"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "availabilityImpact": "None",
            "baseScore": 4.2,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "integrityImpact": "None",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "userInteraction": "None",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:F/RL:X/RC:X",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Information disclosure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://fortiguard.com/advisory/FG-IR-20-183",
              "refsource": "CONFIRM",
              "url": "https://fortiguard.com/advisory/FG-IR-20-183"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2021-36178",
    "datePublished": "2021-10-06T09:18:12.000Z",
    "dateReserved": "2021-07-06T00:00:00.000Z",
    "dateUpdated": "2024-10-25T13:49:37.371Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-36178",
      "date": "2026-09-16",
      "epss": "0.00613",
      "percentile": "0.47718"
    },
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:fortinet:fortisdnconnector:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.1.8\", \"matchCriteriaId\": \"3AE6C99E-9DC8-411A-85A7-38FF390D0944\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup.\"}, {\"lang\": \"es\", \"value\": \"Una protecci\\u00f3n insuficiente de las credenciales en Fortinet FortiSDNConnector versi\\u00f3n 1.1.7 y por debajo, permite a un atacante divulgar informaci\\u00f3n de credenciales de dispositivos de terceros por medio de la b\\u00fasqueda en la p\\u00e1gina de configuraci\\u00f3n\"}]",
      "id": "CVE-2021-36178",
      "lastModified": "2024-11-21T06:13:15.880",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"psirt@fortinet.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\", \"baseScore\": 4.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 1.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:N/A:N\", \"baseScore\": 4.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-10-06T10:15:07.977",
      "references": "[{\"url\": \"https://fortiguard.com/advisory/FG-IR-20-183\", \"source\": \"psirt@fortinet.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://fortiguard.com/advisory/FG-IR-20-183\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "psirt@fortinet.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-522\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-36178\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2021-10-06T10:15:07.977\",\"lastModified\":\"2024-11-21T06:13:15.880\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup.\"},{\"lang\":\"es\",\"value\":\"Una protecci\u00f3n insuficiente de las credenciales en Fortinet FortiSDNConnector versi\u00f3n 1.1.7 y por debajo, permite a un atacante divulgar informaci\u00f3n de credenciales de dispositivos de terceros por medio de la b\u00fasqueda en la p\u00e1gina de configuraci\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-522\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortisdnconnector:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.1.8\",\"matchCriteriaId\":\"3AE6C99E-9DC8-411A-85A7-38FF390D0944\"}]}]}],\"references\":[{\"url\":\"https://fortiguard.com/advisory/FG-IR-20-183\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://fortiguard.com/advisory/FG-IR-20-183\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "redhat_vex": {
      "current_release_date": "2026-03-27T13:49:46+00:00",
      "cve": "CVE-2021-36178",
      "id": "CVE-2021-36178",
      "initial_release_date": "2021-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2021-36178",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-36178.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://fortiguard.com/advisory/FG-IR-20-183\", \"tags\": [\"x_refsource_CONFIRM\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T00:47:43.943Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2021-36178\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-23T13:58:14.516117Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-23T13:59:22.390Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:F/RL:X/RC:X\", \"temporalScore\": 4.2, \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"remediationLevel\": \"NOT_DEFINED\", \"reportConfidence\": \"NOT_DEFINED\", \"temporalSeverity\": \"MEDIUM\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"exploitCodeMaturity\": \"FUNCTIONAL\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Fortinet\", \"product\": \"Fortinet FortiSDNConnector\", \"versions\": [{\"status\": \"affected\", \"version\": \"FortiSDNConnector 1.1.7, 1.1.6, 1.1.5, 1.1.4, 1.1.3, 1.1.2, 1.1.1, 1.1.0, 1.0.0\"}]}], \"references\": [{\"url\": \"https://fortiguard.com/advisory/FG-IR-20-183\", \"tags\": [\"x_refsource_CONFIRM\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"Information disclosure\"}]}], \"providerMetadata\": {\"orgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"shortName\": \"fortinet\", \"dateUpdated\": \"2021-10-06T09:18:12.000Z\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"scope\": \"Unchanged\", \"version\": \"3.1\", \"baseScore\": 4.2, \"attackVector\": \"Network\", \"baseSeverity\": \"Medium\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:F/RL:X/RC:X\", \"integrityImpact\": \"None\", \"userInteraction\": \"None\", \"attackComplexity\": \"Low\", \"availabilityImpact\": \"None\", \"privilegesRequired\": \"Low\", \"confidentialityImpact\": \"Low\"}}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"FortiSDNConnector 1.1.7, 1.1.6, 1.1.5, 1.1.4, 1.1.3, 1.1.2, 1.1.1, 1.1.0, 1.0.0\"}]}, \"product_name\": \"Fortinet FortiSDNConnector\"}]}, \"vendor_name\": \"Fortinet\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://fortiguard.com/advisory/FG-IR-20-183\", \"name\": \"https://fortiguard.com/advisory/FG-IR-20-183\", \"refsource\": \"CONFIRM\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A insufficiently protected credentials in Fortinet FortiSDNConnector version 1.1.7 and below allows attacker to disclose third-party devices credential information via configuration page lookup.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"Information disclosure\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2021-36178\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"psirt@fortinet.com\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2021-36178\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-25T13:49:37.371Z\", \"dateReserved\": \"2021-07-06T00:00:00.000Z\", \"assignerOrgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"datePublished\": \"2021-10-06T09:18:12.000Z\", \"assignerShortName\": \"fortinet\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…