CVE-2021-35082 (GCVE-0-2021-35082)
Vulnerability from cvelistv5 – Published: 2022-06-14 09:50 – Updated: 2024-08-04 00:33
VLAI?
Summary
Improper integrity check can lead to race condition between tasks PDCP and RRC? right after a valid RRC security mode command packet has been received in Snapdragon Industrial IOT
Severity ?
9.1 (Critical)
CWE
- Time-of-check Time-of-use Race Condition in Modem
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Qualcomm, Inc. | Snapdragon Industrial IOT |
Affected:
MDM9206, QCA9367, QCA9377
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:33:50.973Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.qualcomm.com/company/product-security/bulletins/may-2022-bulletin"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Snapdragon Industrial IOT",
"vendor": "Qualcomm, Inc.",
"versions": [
{
"status": "affected",
"version": "MDM9206, QCA9367, QCA9377"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper integrity check can lead to race condition between tasks PDCP and RRC? right after a valid RRC security mode command packet has been received in Snapdragon Industrial IOT"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Time-of-check Time-of-use Race Condition in Modem",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T09:50:52",
"orgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
"shortName": "qualcomm"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.qualcomm.com/company/product-security/bulletins/may-2022-bulletin"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "product-security@qualcomm.com",
"ID": "CVE-2021-35082",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Snapdragon Industrial IOT",
"version": {
"version_data": [
{
"version_value": "MDM9206, QCA9367, QCA9377"
}
]
}
}
]
},
"vendor_name": "Qualcomm, Inc."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper integrity check can lead to race condition between tasks PDCP and RRC? right after a valid RRC security mode command packet has been received in Snapdragon Industrial IOT"
}
]
},
"impact": {
"cvss": {
"baseScore": 9.1,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Time-of-check Time-of-use Race Condition in Modem"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.qualcomm.com/company/product-security/bulletins/may-2022-bulletin",
"refsource": "CONFIRM",
"url": "https://www.qualcomm.com/company/product-security/bulletins/may-2022-bulletin"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
"assignerShortName": "qualcomm",
"cveId": "CVE-2021-35082",
"datePublished": "2022-06-14T09:50:52",
"dateReserved": "2021-06-21T00:00:00",
"dateUpdated": "2024-08-04T00:33:50.973Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:qualcomm:mdm9206_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A960B86A-C397-4ACB-AEE6-55F316D32949\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:qualcomm:mdm9206:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D79B8959-3D1E-4B48-9181-D75FE90AAF98\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:qualcomm:qca9367_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2AD0E09B-92EC-4974-BC5F-66C3AAF586B1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:qualcomm:qca9367:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3FBA48AB-85F4-4D6C-B811-87756B80FFB8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:qualcomm:qca9377_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C4D2B46E-3996-42FD-B932-09E92C02EC8A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:qualcomm:qca9377:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"98E58C63-F253-4DCC-8A14-48FEB64B4C3D\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Improper integrity check can lead to race condition between tasks PDCP and RRC? right after a valid RRC security mode command packet has been received in Snapdragon Industrial IOT\"}, {\"lang\": \"es\", \"value\": \"Una comprobaci\\u00f3n inapropiada de la integridad puede conllevar a una condici\\u00f3n de carrera entre las tareas PDCP y RRC? justo despu\\u00e9s de que haya sido recibido un paquete de comando de modo de seguridad RRC v\\u00e1lido en Snapdragon Industrial IOT\"}]",
"id": "CVE-2021-35082",
"lastModified": "2024-11-21T06:11:50.190",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"product-security@qualcomm.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\", \"baseScore\": 9.1, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.2}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:C/I:C/A:C\", \"baseScore\": 9.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.6, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-06-14T10:15:16.123",
"references": "[{\"url\": \"https://www.qualcomm.com/company/product-security/bulletins/may-2022-bulletin\", \"source\": \"product-security@qualcomm.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.qualcomm.com/company/product-security/bulletins/may-2022-bulletin\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "product-security@qualcomm.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-367\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-35082\",\"sourceIdentifier\":\"product-security@qualcomm.com\",\"published\":\"2022-06-14T10:15:16.123\",\"lastModified\":\"2024-11-21T06:11:50.190\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper integrity check can lead to race condition between tasks PDCP and RRC? right after a valid RRC security mode command packet has been received in Snapdragon Industrial IOT\"},{\"lang\":\"es\",\"value\":\"Una comprobaci\u00f3n inapropiada de la integridad puede conllevar a una condici\u00f3n de carrera entre las tareas PDCP y RRC? justo despu\u00e9s de que haya sido recibido un paquete de comando de modo de seguridad RRC v\u00e1lido en Snapdragon Industrial IOT\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"product-security@qualcomm.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-367\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:qualcomm:mdm9206_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A960B86A-C397-4ACB-AEE6-55F316D32949\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:qualcomm:mdm9206:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D79B8959-3D1E-4B48-9181-D75FE90AAF98\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:qualcomm:qca9367_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2AD0E09B-92EC-4974-BC5F-66C3AAF586B1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:qualcomm:qca9367:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3FBA48AB-85F4-4D6C-B811-87756B80FFB8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:qualcomm:qca9377_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C4D2B46E-3996-42FD-B932-09E92C02EC8A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:qualcomm:qca9377:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"98E58C63-F253-4DCC-8A14-48FEB64B4C3D\"}]}]}],\"references\":[{\"url\":\"https://www.qualcomm.com/company/product-security/bulletins/may-2022-bulletin\",\"source\":\"product-security@qualcomm.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.qualcomm.com/company/product-security/bulletins/may-2022-bulletin\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.