Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2021-34303 (GCVE-0-2021-34303)
Vulnerability from cvelistv5
- CWE-126 - Buffer Over-read
URL | Tags | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
Siemens | JT2Go |
Version: All versions < V13.2 |
|||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T00:05:52.529Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-848/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "JT2Go", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.2" } ] }, { "product": "Teamcenter Visualization", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.2" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-126", "description": "CWE-126: Buffer Over-read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-07-19T10:07:22", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-848/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-34303", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "JT2Go", "version": { "version_data": [ { "version_value": "All versions \u003c V13.2" } ] } }, { "product_name": "Teamcenter Visualization", "version": { "version_data": [ { "version_value": "All versions \u003c V13.2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-126: Buffer Over-read" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-848/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-848/" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-34303", "datePublished": "2021-07-13T11:03:20", "dateReserved": "2021-06-08T00:00:00", "dateUpdated": "2024-08-04T00:05:52.529Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-34303\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-07-13T11:15:11.137\",\"lastModified\":\"2024-11-21T06:10:07.167\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2), Teamcenter Visualization (Todas las versiones anteriores a V13.2). La biblioteca Tiff_Loader.dll de las aplicaciones afectadas no comprueba apropiadamente los datos proporcionados por el usuario cuando se analizan los archivos TIFF. Esto podr\u00eda resultar en una lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante podr\u00eda aprovechar esta vulnerabilidad para filtrar informaci\u00f3n en el contexto del proceso actual. (ZDI-CAN-13198)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-126\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0\",\"matchCriteriaId\":\"CAFFF33E-9758-4C92-B2BF-2CF0E2EA6217\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0\",\"matchCriteriaId\":\"6C391214-6E11-4196-BF69-5327069864D8\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-848/\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-848/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
gsd-2021-34303
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2021-34303", "description": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198)", "id": "GSD-2021-34303" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-34303" ], "details": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198)", "id": "GSD-2021-34303", "modified": "2023-12-13T01:23:14.196141Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-34303", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "JT2Go", "version": { "version_data": [ { "version_value": "All versions \u003c V13.2" } ] } }, { "product_name": "Teamcenter Visualization", "version": { "version_data": [ { "version_value": "All versions \u003c V13.2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-126: Buffer Over-read" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-848/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-848/" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.2.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.2.0", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-34303" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-125" } ] } ] }, "references": { "reference_data": [ { "name": "N/A", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-848/", "refsource": "MISC", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-848/" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6 } }, "lastModifiedDate": "2022-10-07T20:48Z", "publishedDate": "2021-07-13T11:15Z" } } }
ghsa-pwwx-gm9f-wfwx
Vulnerability from github
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198)
{ "affected": [], "aliases": [ "CVE-2021-34303" ], "database_specific": { "cwe_ids": [ "CWE-125", "CWE-126", "CWE-20" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-07-13T11:15:00Z", "severity": "MODERATE" }, "details": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198)", "id": "GHSA-pwwx-gm9f-wfwx", "modified": "2022-10-08T00:00:18Z", "published": "2022-05-24T19:07:41Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-34303" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "type": "WEB", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-848" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "type": "CVSS_V3" } ] }
CERTFR-2021-AVI-518
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | SIMIT Simulation Platform toutes les versions | ||
Siemens | N/A | JT Utilities toutes les versions antérieures à 13.0.2.0 | ||
Siemens | N/A | SICAM 230 toutes les versions | ||
Siemens | N/A | Development/Evaluation Kits for PROFINET IO:DK Standard Ethernet Controller, EK-ERTEC 200 ET EK-ERTEC 200P toutes les versions | ||
Siemens | N/A | TIM 1531 IRC (incl. SIPLUS NET variants) toutes les versions antérieures à 2.2 | ||
Siemens | N/A | SINEC INS toutes les versions | ||
Siemens | N/A | Les produits Teamcenter, pour plus d'informations veuillez-vous référer aux avis éditeurs | ||
Siemens | N/A | Les produits SINAMICS, pour plus d'informations veuillez-vous référer aux avis éditeurs | ||
Siemens | N/A | SIMOCODE proV PROFINET toutes les versions antérieures à 2.1.3 | ||
Siemens | N/A | SOFTNET-IE PNIO toutes les versions | ||
Siemens | N/A | PSS CAPE Protection Simulation Platform:CAPE 14 installé avant le 16 juin | ||
Siemens | N/A | SINEMA Server V14.0.2.x | ||
Siemens | N/A | Les produits SINUMERIK, pour plus d'informations veuillez-vous référer aux avis éditeurs | ||
Siemens | N/A | JT2Go toutes les versions antérieures à 13.2 | ||
Siemens | N/A | Les produits Mendix, pour plus d'informations veuillez-vous référer aux avis éditeurs | ||
Siemens | N/A | SIMOCODE proV Ethernet/IP toutes les versions antérieures à 1.1.3 | ||
Siemens | N/A | SINEC NMS:V1.0 SP1, V1.0 SP1 antérieures à version V1.0 SP2 | ||
Siemens | N/A | Les produits SCALANCE, pour plus d'informations veuillez-vous référer aux avis éditeurs | ||
Siemens | N/A | TIA Administrator toutes les versions | ||
Siemens | N/A | RWG1.M12D toutes les versions | ||
Siemens | N/A | Solid Edge SE2021 toutes les versions antérieures à SE2021MP5 | ||
Siemens | N/A | RWG1.M12 toutes les versions | ||
Siemens | N/A | Les produits SIMATIC, pour plus d'informations veuillez-vous référer aux avis éditeurs | ||
Siemens | N/A | RWG1.M8 toutes les versions | ||
Siemens | N/A | Les produits RUGGEDCOM, pour plus d'informations veuillez-vous référer aux avis éditeurs | ||
Siemens | N/A | SINEC PNI toutes les versions | ||
Siemens | N/A | SINEMA Remote Connect Server toutes les versions |
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "SIMIT Simulation Platform toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "JT Utilities toutes les versions ant\u00e9rieures \u00e0 13.0.2.0", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SICAM 230 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Development/Evaluation Kits for PROFINET IO:DK Standard Ethernet Controller, EK-ERTEC 200 ET EK-ERTEC 200P toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIM 1531 IRC (incl. SIPLUS NET variants) toutes les versions ant\u00e9rieures \u00e0 2.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEC INS toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Les produits Teamcenter, pour plus d\u0027informations veuillez-vous r\u00e9f\u00e9rer aux avis \u00e9diteurs", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Les produits SINAMICS, pour plus d\u0027informations veuillez-vous r\u00e9f\u00e9rer aux avis \u00e9diteurs", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMOCODE proV PROFINET toutes les versions ant\u00e9rieures \u00e0 2.1.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SOFTNET-IE PNIO toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "PSS CAPE Protection Simulation Platform:CAPE 14 install\u00e9 avant le 16 juin", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEMA Server V14.0.2.x", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Les produits SINUMERIK, pour plus d\u0027informations veuillez-vous r\u00e9f\u00e9rer aux avis \u00e9diteurs", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "JT2Go toutes les versions ant\u00e9rieures \u00e0 13.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Les produits Mendix, pour plus d\u0027informations veuillez-vous r\u00e9f\u00e9rer aux avis \u00e9diteurs", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMOCODE proV Ethernet/IP toutes les versions ant\u00e9rieures \u00e0 1.1.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEC NMS:V1.0 SP1, V1.0 SP1 ant\u00e9rieures \u00e0 version V1.0 SP2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Les produits SCALANCE, pour plus d\u0027informations veuillez-vous r\u00e9f\u00e9rer aux avis \u00e9diteurs", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TIA Administrator toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RWG1.M12D toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Solid Edge SE2021 toutes les versions ant\u00e9rieures \u00e0 SE2021MP5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RWG1.M12 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Les produits SIMATIC, pour plus d\u0027informations veuillez-vous r\u00e9f\u00e9rer aux avis \u00e9diteurs", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "RWG1.M8 toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Les produits RUGGEDCOM, pour plus d\u0027informations veuillez-vous r\u00e9f\u00e9rer aux avis \u00e9diteurs", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEC PNI toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINEMA Remote Connect Server toutes les versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2021-34320", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34320" }, { "name": "CVE-2021-34300", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34300" }, { "name": "CVE-2015-8011", "url": "https://www.cve.org/CVERecord?id=CVE-2015-8011" }, { "name": "CVE-2021-34331", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34331" }, { "name": "CVE-2021-34297", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34297" }, { "name": "CVE-2021-31893", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31893" }, { "name": "CVE-2021-34324", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34324" }, { "name": "CVE-2021-34316", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34316" }, { "name": "CVE-2021-34292", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34292" }, { "name": "CVE-2021-33713", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33713" }, { "name": "CVE-2021-31892", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31892" }, { "name": "CVE-2021-34307", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34307" }, { "name": "CVE-2021-34310", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34310" }, { "name": "CVE-2021-34299", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34299" }, { "name": "CVE-2021-33715", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33715" }, { "name": "CVE-2021-34293", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34293" }, { "name": "CVE-2021-34302", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34302" }, { "name": "CVE-2021-34309", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34309" }, { "name": "CVE-2021-34301", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34301" }, { "name": "CVE-2021-34305", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34305" }, { "name": "CVE-2021-34313", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34313" }, { "name": "CVE-2021-33718", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33718" }, { "name": "CVE-2021-25671", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25671" }, { "name": "CVE-2021-29998", "url": "https://www.cve.org/CVERecord?id=CVE-2021-29998" }, { "name": "CVE-2021-34330", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34330" }, { "name": "CVE-2021-34319", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34319" }, { "name": "CVE-2021-3449", "url": "https://www.cve.org/CVERecord?id=CVE-2021-3449" }, { "name": "CVE-2021-31895", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31895" }, { "name": "CVE-2020-15782", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15782" }, { "name": "CVE-2021-34333", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34333" }, { "name": "CVE-2021-34308", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34308" }, { "name": "CVE-2021-34317", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34317" }, { "name": "CVE-2021-34321", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34321" }, { "name": "CVE-2021-20094", "url": "https://www.cve.org/CVERecord?id=CVE-2021-20094" }, { "name": "CVE-2021-20093", "url": "https://www.cve.org/CVERecord?id=CVE-2021-20093" }, { "name": "CVE-2021-34295", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34295" }, { "name": "CVE-2020-27827", "url": "https://www.cve.org/CVERecord?id=CVE-2020-27827" }, { "name": "CVE-2021-34328", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34328" }, { "name": "CVE-2021-34326", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34326" }, { "name": "CVE-2021-34318", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34318" }, { "name": "CVE-2021-34315", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34315" }, { "name": "CVE-2021-34327", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34327" }, { "name": "CVE-2020-26147", "url": "https://www.cve.org/CVERecord?id=CVE-2020-26147" }, { "name": "CVE-2021-34322", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34322" }, { "name": "CVE-2021-34304", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34304" }, { "name": "CVE-2021-34314", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34314" }, { "name": "CVE-2020-28400", "url": "https://www.cve.org/CVERecord?id=CVE-2020-28400" }, { "name": "CVE-2021-34311", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34311" }, { "name": "CVE-2021-33714", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33714" }, { "name": "CVE-2021-34296", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34296" }, { "name": "CVE-2021-31894", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31894" }, { "name": "CVE-2021-33710", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33710" }, { "name": "CVE-2021-34312", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34312" }, { "name": "CVE-2021-34329", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34329" }, { "name": "CVE-2021-34303", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34303" }, { "name": "CVE-2021-34306", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34306" }, { "name": "CVE-2021-34298", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34298" }, { "name": "CVE-2021-34291", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34291" }, { "name": "CVE-2021-33709", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33709" }, { "name": "CVE-2021-34325", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34325" }, { "name": "CVE-2021-34332", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34332" }, { "name": "CVE-2021-34323", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34323" }, { "name": "CVE-2021-34294", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34294" }, { "name": "CVE-2021-33711", "url": "https://www.cve.org/CVERecord?id=CVE-2021-33711" } ], "initial_release_date": "2021-07-13T00:00:00", "last_revision_date": "2021-07-13T00:00:00", "links": [], "reference": "CERTFR-2021-AVI-518", "revisions": [ { "description": "Version initiale", "revision_date": "2021-07-13T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Injection de code indirecte \u00e0 distance (XSS)" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-641963 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-641963.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-729965 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-560465 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-560465.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-772220 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-434536 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434536.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-209268 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-209268.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-173615 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-675303 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-434535 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434535.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-599968 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-622535 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622535.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-941426 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-941426.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-661034 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-373591 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-373591.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-352521 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352521.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-913875 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-483182 du 13 juillet 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" } ] }
icsa-21-194-15
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Brian Gorenc", "Mat Powell" ], "organization": "Trend Micro Zero Day Initiative", "summary": "reporting these vulnerabilities to CISA" }, { "names": [ "garmin", "xina1i" ], "organization": "SecZone", "summary": "reporting these vulnerabilities to CISA" }, { "names": [ "Tran Van Khang - khangkito" ], "organization": "VinCSS", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "summary", "text": "Brian Gorenc and Mat Powell of Trend Micro Zero Day Initiative; garmin and xina1i at SecZone; and Tran Van Khang - khangkito (VinCSS) working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.", "title": "Summary" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "CISAservicedesk@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-194-15 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-194-15.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-194-15 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-194-15" } ], "title": "ICSA-21-194-15_Siemens JT2Go and Teamcenter Visualization", "tracking": { "current_release_date": "2021-07-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA USCert CSAF Generator", "version": "1" } }, "id": "ICSA-21-194-15", "initial_release_date": "2021-07-13T00:00:00.000000Z", "revision_history": [ { "date": "2021-07-13T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-194-15 Siemens JT2Go and Teamcenter Visualization" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 13.2", "product": { "name": "Teamcenter Visualization: All versions prior to v13.2", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Teamcenter Visualization" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 13.2", "product": { "name": "JT2Go: All versions prior to v13.2", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "JT2Go" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-34333", "cwe": { "id": "CWE-415", "name": "Double Free" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in a double free of an allocated buffer that leads to a crash. An attacker could leverage this vulnerability to cause denial-of-service condition.CVE-2021-34333 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34333" }, { "cve": "CVE-2021-34332", "cwe": { "id": "CWE-835", "name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in an infinite loop condition that leads to a denial-of-service condition. An attacker could leverage this vulnerability to consume excessive resources.CVE-2021-34332 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34332" }, { "cve": "CVE-2021-34331", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34331 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34331" }, { "cve": "CVE-2021-34330", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34330 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34330" }, { "cve": "CVE-2021-34329", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code. The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34329 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34329" }, { "cve": "CVE-2021-34328", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34328 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34328" }, { "cve": "CVE-2021-34327", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing ASM files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34327 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34327" }, { "cve": "CVE-2021-34326", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. CVE-2021-34326 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34326" }, { "cve": "CVE-2021-34325", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. CVE-2021-34325 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34325" }, { "cve": "CVE-2021-34324", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. CVE-2021-34324 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34324" }, { "cve": "CVE-2021-34323", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. CVE-2021-34323 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34323" }, { "cve": "CVE-2021-34322", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The JPEG2K_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. CVE-2021-34322 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34322" }, { "cve": "CVE-2021-34321", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The VisDraw.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34321 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34321" }, { "cve": "CVE-2021-34320", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34320 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34320" }, { "cve": "CVE-2021-34319", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34319 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34319 " }, { "cve": "CVE-2021-34318", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34318 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34318" }, { "cve": "CVE-2021-34317", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCX files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34317 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34317" }, { "cve": "CVE-2021-34316", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The DL180CoolType.dll library in affected applications lacks proper validation of user-supplied data when parsing PDF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34316 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34316" }, { "cve": "CVE-2021-34315", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34315 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34315" }, { "cve": "CVE-2021-34314", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34314 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34314 " }, { "cve": "CVE-2021-34313", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34313 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34313" }, { "cve": "CVE-2021-34312", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34312 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34312" }, { "cve": "CVE-2021-34311", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Mono_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34311 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34311" }, { "cve": "CVE-2021-34310", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34310 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34310" }, { "cve": "CVE-2021-34309", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34309 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34309" }, { "cve": "CVE-2021-34308", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34308 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34308" }, { "cve": "CVE-2021-34307", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34307 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34307" }, { "cve": "CVE-2021-34306", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34306 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34306" }, { "cve": "CVE-2021-34305", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34305 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34305" }, { "cve": "CVE-2021-34304", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34304 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34304" }, { "cve": "CVE-2021-34303", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34303 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34303" }, { "cve": "CVE-2021-34302", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34302 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34302" }, { "cve": "CVE-2021-34301", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing BMP files. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34301 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34301" }, { "cve": "CVE-2021-34300", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34300 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34300" }, { "cve": "CVE-2021-34299", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34299 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34299" }, { "cve": "CVE-2021-34298", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing BMP files. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34298 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34298" }, { "cve": "CVE-2021-34297", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34297 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34297" }, { "cve": "CVE-2021-34296", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34296 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34296" }, { "cve": "CVE-2021-34295", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34295 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34295" }, { "cve": "CVE-2021-34294", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34294 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34294" }, { "cve": "CVE-2021-34293", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34293 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34293" }, { "cve": "CVE-2021-34292", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34292 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34292" }, { "cve": "CVE-2021-34291", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34291 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34291" } ] }
ICSA-21-194-15
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Brian Gorenc", "Mat Powell" ], "organization": "Trend Micro Zero Day Initiative", "summary": "reporting these vulnerabilities to CISA" }, { "names": [ "garmin", "xina1i" ], "organization": "SecZone", "summary": "reporting these vulnerabilities to CISA" }, { "names": [ "Tran Van Khang - khangkito" ], "organization": "VinCSS", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "summary", "text": "Brian Gorenc and Mat Powell of Trend Micro Zero Day Initiative; garmin and xina1i at SecZone; and Tran Van Khang - khangkito (VinCSS) working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.", "title": "Summary" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "CISAservicedesk@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-194-15 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-194-15.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-194-15 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-194-15" } ], "title": "ICSA-21-194-15_Siemens JT2Go and Teamcenter Visualization", "tracking": { "current_release_date": "2021-07-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA USCert CSAF Generator", "version": "1" } }, "id": "ICSA-21-194-15", "initial_release_date": "2021-07-13T00:00:00.000000Z", "revision_history": [ { "date": "2021-07-13T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-194-15 Siemens JT2Go and Teamcenter Visualization" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 13.2", "product": { "name": "Teamcenter Visualization: All versions prior to v13.2", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Teamcenter Visualization" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 13.2", "product": { "name": "JT2Go: All versions prior to v13.2", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "JT2Go" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-34333", "cwe": { "id": "CWE-415", "name": "Double Free" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in a double free of an allocated buffer that leads to a crash. An attacker could leverage this vulnerability to cause denial-of-service condition.CVE-2021-34333 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34333" }, { "cve": "CVE-2021-34332", "cwe": { "id": "CWE-835", "name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. A malformed input file could result in an infinite loop condition that leads to a denial-of-service condition. An attacker could leverage this vulnerability to consume excessive resources.CVE-2021-34332 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34332" }, { "cve": "CVE-2021-34331", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34331 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34331" }, { "cve": "CVE-2021-34330", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34330 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34330" }, { "cve": "CVE-2021-34329", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code. The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34329 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34329" }, { "cve": "CVE-2021-34328", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34328 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34328" }, { "cve": "CVE-2021-34327", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing ASM files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34327 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34327" }, { "cve": "CVE-2021-34326", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. CVE-2021-34326 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34326" }, { "cve": "CVE-2021-34325", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. CVE-2021-34325 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34325" }, { "cve": "CVE-2021-34324", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. CVE-2021-34324 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34324" }, { "cve": "CVE-2021-34323", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. CVE-2021-34323 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34323" }, { "cve": "CVE-2021-34322", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The JPEG2K_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. CVE-2021-34322 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34322" }, { "cve": "CVE-2021-34321", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The VisDraw.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34321 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34321" }, { "cve": "CVE-2021-34320", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Jt981.dll library in affected applications lacks proper validation of user-supplied data when parsing JT files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34320 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34320" }, { "cve": "CVE-2021-34319", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34319 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34319 " }, { "cve": "CVE-2021-34318", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34318 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34318" }, { "cve": "CVE-2021-34317", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCX files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34317 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34317" }, { "cve": "CVE-2021-34316", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The DL180CoolType.dll library in affected applications lacks proper validation of user-supplied data when parsing PDF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34316 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34316" }, { "cve": "CVE-2021-34315", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34315 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34315" }, { "cve": "CVE-2021-34314", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing SGI files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34314 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34314 " }, { "cve": "CVE-2021-34313", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34313 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34313" }, { "cve": "CVE-2021-34312", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34312 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34312" }, { "cve": "CVE-2021-34311", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Mono_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34311 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34311" }, { "cve": "CVE-2021-34310", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34310 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34310" }, { "cve": "CVE-2021-34309", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34309 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34309" }, { "cve": "CVE-2021-34308", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34308 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34308" }, { "cve": "CVE-2021-34307", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34307 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34307" }, { "cve": "CVE-2021-34306", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34306 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34306" }, { "cve": "CVE-2021-34305", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34305 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34305" }, { "cve": "CVE-2021-34304", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34304 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34304" }, { "cve": "CVE-2021-34303", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34303 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34303" }, { "cve": "CVE-2021-34302", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34302 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34302" }, { "cve": "CVE-2021-34301", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing BMP files. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34301 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34301" }, { "cve": "CVE-2021-34300", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds write past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34300 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34300" }, { "cve": "CVE-2021-34299", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process.CVE-2021-34299 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34299" }, { "cve": "CVE-2021-34298", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data prior to performing further free operations on an object when parsing BMP files. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34298 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34298" }, { "cve": "CVE-2021-34297", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34297 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34297" }, { "cve": "CVE-2021-34296", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The BMP_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing BMP files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34296 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34296" }, { "cve": "CVE-2021-34295", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34295 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34295" }, { "cve": "CVE-2021-34294", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34294 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34294" }, { "cve": "CVE-2021-34293", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34293 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34293" }, { "cve": "CVE-2021-34292", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out-of-bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34292 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34292" }, { "cve": "CVE-2021-34291", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "The Gif_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing GIF files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.CVE-2021-34291 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens Operational Guidelines for Industrial Security, and to follow the recommendations in the product manuals.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://cert-portal.siemens.com/operational-guidelines-industrial-security.pdf" }, { "category": "mitigation", "details": "JT2Go: Update to v13.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "mitigation", "details": "Teamcenter Visualization: Update to v13.2 (login required)", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ], "url": "https://support.sw.siemens.com/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-34291" } ] }
cnvd-2021-53358
Vulnerability from cnvd
厂商已发布了漏洞修复程序,请及时关注更新: https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf
Name | ['SIEMENS JT2Go <13.2', 'SIEMENS Teamcenter Visualization <13.2'] |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2021-34303", "cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2021-34303" } }, "description": "Siemens Jt2go\u548cSiemens Teamcenter Visualization\u90fd\u662f\u5fb7\u56fdSiemens\u516c\u53f8\u7684\u4ea7\u54c1\u3002Siemens Jt2go\u662f\u4e00\u6b3eJT\u6587\u4ef6\u67e5\u770b\u5668\u3002Siemens Teamcenter Visualization\u662f\u4e00\u4e2a\u53ef\u4e3a\u8bbe\u8ba12D\u30013D\u573a\u666f\u63d0\u4f9b\u56e2\u961f\u534f\u4f5c\u529f\u80fd\u7684\u8f6f\u4ef6\u3002\n\nSiemens JT2Go 13.2\u4e4b\u524d\u7248\u672c\u548cTeamcenter Visualization 13.2\u4e4b\u524d\u7248\u672c\u5b58\u5728\u7f13\u51b2\u533a\u8fc7\u8bfb\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8eTiff_Loader.dll\u5e93\u5728\u89e3\u6790TIFF\u6587\u4ef6\u65f6\u672a\u80fd\u6b63\u786e\u9a8c\u8bc1\u7528\u6237\u63d0\u4f9b\u7684\u6570\u636e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6cc4\u6f0f\u4fe1\u606f\u3002", "formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2021-53358", "openTime": "2021-07-22", "patchDescription": "Siemens Jt2go\u548cSiemens Teamcenter Visualization\u90fd\u662f\u5fb7\u56fdSiemens\u516c\u53f8\u7684\u4ea7\u54c1\u3002Siemens Jt2go\u662f\u4e00\u6b3eJT\u6587\u4ef6\u67e5\u770b\u5668\u3002Siemens Teamcenter Visualization\u662f\u4e00\u4e2a\u53ef\u4e3a\u8bbe\u8ba12D\u30013D\u573a\u666f\u63d0\u4f9b\u56e2\u961f\u534f\u4f5c\u529f\u80fd\u7684\u8f6f\u4ef6\u3002\r\n\r\nSiemens JT2Go 13.2\u4e4b\u524d\u7248\u672c\u548cTeamcenter Visualization 13.2\u4e4b\u524d\u7248\u672c\u5b58\u5728\u7f13\u51b2\u533a\u8fc7\u8bfb\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8eTiff_Loader.dll\u5e93\u5728\u89e3\u6790TIFF\u6587\u4ef6\u65f6\u672a\u80fd\u6b63\u786e\u9a8c\u8bc1\u7528\u6237\u63d0\u4f9b\u7684\u6570\u636e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6cc4\u6f0f\u4fe1\u606f\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens Jt2go\u548cSiemens Teamcenter Visualization\u7f13\u51b2\u533a\u8fc7\u8bfb\u6f0f\u6d1e\uff08CNVD-2021-53358\uff09\u7684\u8865\u4e01", "products": { "product": [ "SIEMENS JT2Go \u003c13.2", "SIEMENS Teamcenter Visualization \u003c13.2" ] }, "referenceLink": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-15", "serverity": "\u4e2d", "submitTime": "2021-07-14", "title": "Siemens Jt2go\u548cSiemens Teamcenter Visualization\u7f13\u51b2\u533a\u8fc7\u8bfb\u6f0f\u6d1e\uff08CNVD-2021-53358\uff09" }
fkie_cve-2021-34303
Vulnerability from fkie_nvd
URL | Tags | ||
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf | Vendor Advisory | |
productcert@siemens.com | https://www.zerodayinitiative.com/advisories/ZDI-21-848/ | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-848/ | Third Party Advisory, VDB Entry |
Vendor | Product | Version | |
---|---|---|---|
siemens | jt2go | * | |
siemens | teamcenter_visualization | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "matchCriteriaId": "CAFFF33E-9758-4C92-B2BF-2CF0E2EA6217", "versionEndExcluding": "13.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C391214-6E11-4196-BF69-5327069864D8", "versionEndExcluding": "13.2.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198)" }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2), Teamcenter Visualization (Todas las versiones anteriores a V13.2). La biblioteca Tiff_Loader.dll de las aplicaciones afectadas no comprueba apropiadamente los datos proporcionados por el usuario cuando se analizan los archivos TIFF. Esto podr\u00eda resultar en una lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante podr\u00eda aprovechar esta vulnerabilidad para filtrar informaci\u00f3n en el contexto del proceso actual. (ZDI-CAN-13198)" } ], "id": "CVE-2021-34303", "lastModified": "2024-11-21T06:10:07.167", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-07-13T11:15:11.137", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-848/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-848/" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-126" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
var-202107-1398
Vulnerability from variot
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198). JT2Go and Teamcenter Visualization There are input validation and out-of-bounds read vulnerabilities. Zero Day Initiative To this vulnerability ZDI-CAN-13198 Was numbered.Information may be obtained. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of TIFF files
Show details on source website{ "affected_products": { "_id": null, "data": [ { "_id": null, "model": "jt2go", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "13.2.0" }, { "_id": null, "model": "teamcenter visualization", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "13.2.0" }, { "_id": null, "model": "teamcenter visualization", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "13.2" }, { "_id": null, "model": "jt2go", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "_id": null, "model": "jt2go", "scope": null, "trust": 0.7, "vendor": "siemens", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-848" }, { "db": "JVNDB", "id": "JVNDB-2021-009335" }, { "db": "NVD", "id": "CVE-2021-34303" } ] }, "configurations": { "_id": null, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.2.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.2.0", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-34303" } ] }, "credits": { "_id": null, "data": "xina1i at SecZone", "sources": [ { "db": "ZDI", "id": "ZDI-21-848" } ], "trust": 0.7 }, "cve": "CVE-2021-34303", "cvss": { "_id": null, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-34303", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-34303", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "NONE", "baseScore": 3.3, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "exploitabilityScore": 1.8, "id": "CVE-2021-34303", "impactScore": 1.4, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-34303", "trust": 1.8, "value": "MEDIUM" }, { "author": "ZDI", "id": "CVE-2021-34303", "trust": 0.7, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202107-878", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-34303", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-848" }, { "db": "VULMON", "id": "CVE-2021-34303" }, { "db": "JVNDB", "id": "JVNDB-2021-009335" }, { "db": "NVD", "id": "CVE-2021-34303" }, { "db": "CNNVD", "id": "CNNVD-202107-878" } ] }, "description": { "_id": null, "data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13198). JT2Go and Teamcenter Visualization There are input validation and out-of-bounds read vulnerabilities. Zero Day Initiative To this vulnerability ZDI-CAN-13198 Was numbered.Information may be obtained. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of TIFF files", "sources": [ { "db": "NVD", "id": "CVE-2021-34303" }, { "db": "JVNDB", "id": "JVNDB-2021-009335" }, { "db": "ZDI", "id": "ZDI-21-848" }, { "db": "VULMON", "id": "CVE-2021-34303" } ], "trust": 2.34 }, "external_ids": { "_id": null, "data": [ { "db": "NVD", "id": "CVE-2021-34303", "trust": 4.0 }, { "db": "ZDI", "id": "ZDI-21-848", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-483182", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2021-009335", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-13198", "trust": 0.7 }, { "db": "ICS CERT", "id": "ICSA-21-194-15", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202107-878", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-34303", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-848" }, { "db": "VULMON", "id": "CVE-2021-34303" }, { "db": "JVNDB", "id": "JVNDB-2021-009335" }, { "db": "NVD", "id": "CVE-2021-34303" }, { "db": "CNNVD", "id": "CNNVD-202107-878" } ] }, "id": "VAR-202107-1398", "iot": { "_id": null, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.15799868 }, "last_update_date": "2023-12-18T10:56:41.086000Z", "patch": { "_id": null, "data": [ { "title": "SSA-483182", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "title": "", "trust": 0.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-15https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "title": "Siemens Jt2go and Siemens Teamcenter Visualization Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=156571" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=aa85c53444a3e0726ddb55922c9060c8" }, { "title": "", "trust": 0.1, "url": "https://github.com/live-hack-cve/cve-2021-34303 " } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-848" }, { "db": "VULMON", "id": "CVE-2021-34303" }, { "db": "JVNDB", "id": "JVNDB-2021-009335" }, { "db": "CNNVD", "id": "CNNVD-202107-878" } ] }, "problemtype_data": { "_id": null, "data": [ { "problemtype": "CWE-125", "trust": 1.0 }, { "problemtype": "Out-of-bounds read (CWE-125) [NVD Evaluation ]", "trust": 0.8 }, { "problemtype": " Incorrect input confirmation (CWE-20) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009335" }, { "db": "NVD", "id": "CVE-2021-34303" } ] }, "references": { "_id": null, "data": [ { "trust": 3.2, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-848/" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-34303" }, { "trust": 0.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-15https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-15" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/125.html" }, { "trust": 0.1, "url": "https://github.com/live-hack-cve/cve-2021-34303" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-848" }, { "db": "VULMON", "id": "CVE-2021-34303" }, { "db": "JVNDB", "id": "JVNDB-2021-009335" }, { "db": "NVD", "id": "CVE-2021-34303" }, { "db": "CNNVD", "id": "CNNVD-202107-878" } ] }, "sources": { "_id": null, "data": [ { "db": "ZDI", "id": "ZDI-21-848", "ident": null }, { "db": "VULMON", "id": "CVE-2021-34303", "ident": null }, { "db": "JVNDB", "id": "JVNDB-2021-009335", "ident": null }, { "db": "NVD", "id": "CVE-2021-34303", "ident": null }, { "db": "CNNVD", "id": "CNNVD-202107-878", "ident": null } ] }, "sources_release_date": { "_id": null, "data": [ { "date": "2021-07-19T00:00:00", "db": "ZDI", "id": "ZDI-21-848", "ident": null }, { "date": "2021-07-13T00:00:00", "db": "VULMON", "id": "CVE-2021-34303", "ident": null }, { "date": "2022-04-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-009335", "ident": null }, { "date": "2021-07-13T11:15:11.137000", "db": "NVD", "id": "CVE-2021-34303", "ident": null }, { "date": "2021-07-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-878", "ident": null } ] }, "sources_update_date": { "_id": null, "data": [ { "date": "2021-07-19T00:00:00", "db": "ZDI", "id": "ZDI-21-848", "ident": null }, { "date": "2022-10-07T00:00:00", "db": "VULMON", "id": "CVE-2021-34303", "ident": null }, { "date": "2022-04-20T09:00:00", "db": "JVNDB", "id": "JVNDB-2021-009335", "ident": null }, { "date": "2022-10-07T20:48:00.843000", "db": "NVD", "id": "CVE-2021-34303", "ident": null }, { "date": "2022-10-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-878", "ident": null } ] }, "threat_type": { "_id": null, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-878" } ], "trust": 0.6 }, "title": { "_id": null, "data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Input confirmation vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009335" } ], "trust": 0.8 }, "type": { "_id": null, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-878" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.