GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2021-32010 (GCVE-0-2021-32010)

Vulnerability from cvelistv5 – Published: 2022-05-04 13:45 – Updated: 2024-08-03 23:17
VLAI
Title
Clients may connect to a GateManager with TLS 1.0
Summary
Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7.
CWE
  • CWE-326 - Inadequate Encryption Strength
References
Impacted products
Vendor Product Version CPE status
Secomea SiteManager Affected: All , < 9.7 (custom)
guessed Create a notification for this product.
Secomea LinkManager Affected: unspecified , < 9.7 (custom)
guessed Create a notification for this product.
Secomea GateManager Affected: unspecified , < 9.7 (custom)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:17:28.463Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.secomea.com/support/cybersecurity-advisory/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiteManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "LinkManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "GateManager",
          "vendor": "Secomea",
          "versions": [
            {
              "lessThan": "9.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326 Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-04T13:45:03.000Z",
        "orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
        "shortName": "Secomea"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.secomea.com/support/cybersecurity-advisory/"
        }
      ],
      "source": {
        "defect": [
          "RD-5699"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Clients may connect to a GateManager with TLS 1.0",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "VulnerabilityReporting@secomea.com",
          "ID": "CVE-2021-32010",
          "STATE": "PUBLIC",
          "TITLE": "Clients may connect to a GateManager with TLS 1.0"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiteManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "LinkManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "GateManager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Secomea"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-326 Inadequate Encryption Strength"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.secomea.com/support/cybersecurity-advisory/",
              "refsource": "MISC",
              "url": "https://www.secomea.com/support/cybersecurity-advisory/"
            }
          ]
        },
        "source": {
          "defect": [
            "RD-5699"
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
    "assignerShortName": "Secomea",
    "cveId": "CVE-2021-32010",
    "datePublished": "2022-05-04T13:45:03.000Z",
    "dateReserved": "2021-05-03T00:00:00.000Z",
    "dateUpdated": "2024-08-03T23:17:28.463Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-32010",
      "date": "2026-09-16",
      "epss": "0.00228",
      "percentile": "0.13664"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:sitemanager_1129_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"7129D184-BF8A-4458-BE20-14DB478B8306\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:sitemanager_1129:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"29BFC1D6-82B6-4E20-BBFB-63F33373D78B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:sitemanager_1139_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"1FB6241F-5E35-4635-87CA-69F9394E0969\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:sitemanager_1139:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"856E0FE1-D1FD-47A3-8DE0-A12F6FBD60E8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:sitemanager_1149_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"080C47BD-BF42-43DE-8C89-3A289CC3DF96\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:sitemanager_1149:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"060DA5EF-B6FE-4E02-B0A5-EAAF5CF5AC35\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:sitemanager_3329_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"5C657B3D-BEE4-4341-94F3-AC079FB2D0E4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:sitemanager_3329:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6ABE08F2-C6D0-4CA3-99F4-0654653E7BF3\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:sitemanager_3339_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"F45C7EB4-AE1A-42C1-8395-4C3FAC4F4DAF\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:sitemanager_3339:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FF64F7DA-FD12-4231-B792-EF8F79B587CF\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:sitemanager_3349_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"A875ACB6-F2BE-4513-9ECD-FDD0FC816618\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:sitemanager_3349:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8C7D7926-A5F5-46A1-A6B7-3C99130FA609\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:sitemanager_3529_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"6C00A040-6825-4F46-A0D6-DBBBD1CBF9F3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:sitemanager_3529:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5C5F7D37-729C-4969-9661-C933C9F16980\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:sitemanager_3539_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"F5B66D1E-202F-4C95-A3C0-5D705717C3EA\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:sitemanager_3539:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1D26BFEA-056C-4760-8D10-A0DF3677DAD1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:sitemanager_3549_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"1A2151C3-0AB1-4255-BCC9-EDD95E85C627\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:sitemanager_3549:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A05A3825-9C8E-43EF-A2DC-F0B06694CCCD\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:secomea:linkmanager:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"8D348764-B7BC-4C8D-BDA6-B42D0281BABC\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:gatemanager_4250_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"D3F34FFF-867B-40A3-9163-E0045B2EE092\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:gatemanager_4250:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0DB6136A-5440-4980-940D-CD178DC219B8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:gatemanager_4260_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"106CA21E-663A-4F1D-80AB-47BFC2EF6DBA\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:gatemanager_4260:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9B546E62-81BB-4ED8-87C9-41BD79484AD0\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:gatemanager_8250_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"E7EC4241-4AAA-4B94-A024-2533B114723A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:gatemanager_8250:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5089C475-2013-4DF6-AD1E-12F576ACAE8E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:secomea:gatemanager_9250_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.7.622134021\", \"matchCriteriaId\": \"A93F1AC2-ADD9-43C1-999F-E27FC588411F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:secomea:gatemanager_9250:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"68DE2092-2EA1-4D49-84EB-20BE2CD7B113\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad de la fuerza de encriptaci\\u00f3n inapropiada en la pila TLS de Secomea SiteManager, LinkManager y GateManager puede facilitar ataques de tipo man in the middle. Este problema afecta a: Secomea SiteManager Todas las versiones anteriores a 9.7. Secomea LinkManager versiones anteriores a 9.7. Las versiones de Secomea GateManager anteriores a 9.7\"}]",
      "id": "CVE-2021-32010",
      "lastModified": "2024-11-21T06:06:42.393",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"VulnerabilityReporting@secomea.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L\", \"baseScore\": 5.6, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 3.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2022-05-04T14:15:07.967",
      "references": "[{\"url\": \"https://www.secomea.com/support/cybersecurity-advisory/\", \"source\": \"VulnerabilityReporting@secomea.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.secomea.com/support/cybersecurity-advisory/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "VulnerabilityReporting@secomea.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"VulnerabilityReporting@secomea.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-326\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-326\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-32010\",\"sourceIdentifier\":\"VulnerabilityReporting@secomea.com\",\"published\":\"2022-05-04T14:15:07.967\",\"lastModified\":\"2024-11-21T06:06:42.393\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de la fuerza de encriptaci\u00f3n inapropiada en la pila TLS de Secomea SiteManager, LinkManager y GateManager puede facilitar ataques de tipo man in the middle. Este problema afecta a: Secomea SiteManager Todas las versiones anteriores a 9.7. Secomea LinkManager versiones anteriores a 9.7. Las versiones de Secomea GateManager anteriores a 9.7\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":5.6,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.2,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"VulnerabilityReporting@secomea.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-326\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-326\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:sitemanager_1129_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"7129D184-BF8A-4458-BE20-14DB478B8306\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:sitemanager_1129:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"29BFC1D6-82B6-4E20-BBFB-63F33373D78B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:sitemanager_1139_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"1FB6241F-5E35-4635-87CA-69F9394E0969\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:sitemanager_1139:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"856E0FE1-D1FD-47A3-8DE0-A12F6FBD60E8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:sitemanager_1149_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"080C47BD-BF42-43DE-8C89-3A289CC3DF96\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:sitemanager_1149:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"060DA5EF-B6FE-4E02-B0A5-EAAF5CF5AC35\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:sitemanager_3329_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"5C657B3D-BEE4-4341-94F3-AC079FB2D0E4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:sitemanager_3329:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6ABE08F2-C6D0-4CA3-99F4-0654653E7BF3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:sitemanager_3339_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"F45C7EB4-AE1A-42C1-8395-4C3FAC4F4DAF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:sitemanager_3339:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FF64F7DA-FD12-4231-B792-EF8F79B587CF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:sitemanager_3349_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"A875ACB6-F2BE-4513-9ECD-FDD0FC816618\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:sitemanager_3349:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8C7D7926-A5F5-46A1-A6B7-3C99130FA609\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:sitemanager_3529_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"6C00A040-6825-4F46-A0D6-DBBBD1CBF9F3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:sitemanager_3529:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C5F7D37-729C-4969-9661-C933C9F16980\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:sitemanager_3539_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"F5B66D1E-202F-4C95-A3C0-5D705717C3EA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:sitemanager_3539:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D26BFEA-056C-4760-8D10-A0DF3677DAD1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:sitemanager_3549_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"1A2151C3-0AB1-4255-BCC9-EDD95E85C627\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:sitemanager_3549:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A05A3825-9C8E-43EF-A2DC-F0B06694CCCD\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:secomea:linkmanager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"8D348764-B7BC-4C8D-BDA6-B42D0281BABC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:gatemanager_4250_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"D3F34FFF-867B-40A3-9163-E0045B2EE092\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:gatemanager_4250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0DB6136A-5440-4980-940D-CD178DC219B8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:gatemanager_4260_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"106CA21E-663A-4F1D-80AB-47BFC2EF6DBA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:gatemanager_4260:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9B546E62-81BB-4ED8-87C9-41BD79484AD0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:gatemanager_8250_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"E7EC4241-4AAA-4B94-A024-2533B114723A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:gatemanager_8250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5089C475-2013-4DF6-AD1E-12F576ACAE8E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:secomea:gatemanager_9250_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.7.622134021\",\"matchCriteriaId\":\"A93F1AC2-ADD9-43C1-999F-E27FC588411F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:secomea:gatemanager_9250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68DE2092-2EA1-4D49-84EB-20BE2CD7B113\"}]}]}],\"references\":[{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/\",\"source\":\"VulnerabilityReporting@secomea.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.secomea.com/support/cybersecurity-advisory/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "redhat_vex": {
      "current_release_date": "2026-03-27T14:05:03+00:00",
      "cve": "CVE-2021-32010",
      "id": "CVE-2021-32010",
      "initial_release_date": "2021-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Clients may connect to a GateManager with TLS 1.0",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-32010.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…