CVE-2021-27380 (GCVE-0-2021-27380)
Vulnerability from cvelistv5
- CWE-787 - Out-of-bounds Write
| URL | Tags | ||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2020 |
Version: All versions < SE2020MP13 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.376Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Solid Edge SE2020",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c SE2020MP13"
}
]
},
{
"product": "Solid Edge SE2021",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c SE2021MP4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-08T19:47:16",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-27380",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Solid Edge SE2020",
"version": {
"version_data": [
{
"version_value": "All versions \u003c SE2020MP13"
}
]
}
},
{
"product_name": "Solid Edge SE2021",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c SE2021MP4"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-27380",
"datePublished": "2021-03-15T17:03:31",
"dateReserved": "2021-02-18T00:00:00",
"dateUpdated": "2024-08-03T20:48:16.376Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2021-27380\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-03-15T17:15:22.207\",\"lastModified\":\"2024-11-21T05:57:52.740\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP13), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP4). Las aplicaciones afectadas carecen de una comprobaci\u00f3n apropiada de los datos proporcionados por el usuario cuando se analizan archivos PAR. Esto podr\u00eda resultar en una escritura fuera de l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-12532)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"se2020\",\"matchCriteriaId\":\"7AF39DFE-A31B-4324-BB62-0B446ACA04B7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"07440B76-B975-4946-8A97-38C564D240E4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:*\",\"matchCriteriaId\":\"5F0A748E-BB6F-4604-8024-F50DC0C20EAF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack10:*:*:*:*:*:*\",\"matchCriteriaId\":\"F4F37267-6B37-46A4-B9F9-4264BEC922D1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack11:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB1DC54B-E715-4425-B6B6-900F2CFBCE03\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack12:*:*:*:*:*:*\",\"matchCriteriaId\":\"1CC1A49B-907A-4317-B7A7-4E85D9C0E386\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:*\",\"matchCriteriaId\":\"2F495722-39BD-4BA1-A643-C7D0BA81CC21\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:*\",\"matchCriteriaId\":\"7B776512-BF3D-4F70-BD58-AFF8E1B03EE2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:*\",\"matchCriteriaId\":\"99E05299-50FD-4292-9978-8E05C1483FE2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:*\",\"matchCriteriaId\":\"2447D05B-2634-4895-B7B0-6F7DBB9D2EC2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:*\",\"matchCriteriaId\":\"CBBD39F3-790F-4017-A57E-6EFC314F0557\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4387BFA-8A98-433E-9EF7-B29226C195A7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E380F66-C11C-472B-9B71-7CB4AF4FABDC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack9:*:*:*:*:*:*\",\"matchCriteriaId\":\"0CF4ACE1-B069-4007-8142-7F90015BBE9D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*\",\"matchCriteriaId\":\"49F5649A-349C-42C6-AFFF-CEE1ABC14E67\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*\",\"matchCriteriaId\":\"756343AA-DB57-40F7-94FA-84BFCDEB6159\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*\",\"matchCriteriaId\":\"36B0DD28-653E-4069-AB5A-38F8EFEB36CA\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
fkie_cve-2021-27380
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf | Patch, Vendor Advisory | |
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf | Patch, Vendor Advisory | |
| productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06 | Third Party Advisory, US Government Resource |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | solid_edge | * | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7AF39DFE-A31B-4324-BB62-0B446ACA04B7",
"versionEndExcluding": "se2020",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:*",
"matchCriteriaId": "07440B76-B975-4946-8A97-38C564D240E4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:*",
"matchCriteriaId": "5F0A748E-BB6F-4604-8024-F50DC0C20EAF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack10:*:*:*:*:*:*",
"matchCriteriaId": "F4F37267-6B37-46A4-B9F9-4264BEC922D1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack11:*:*:*:*:*:*",
"matchCriteriaId": "CB1DC54B-E715-4425-B6B6-900F2CFBCE03",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack12:*:*:*:*:*:*",
"matchCriteriaId": "1CC1A49B-907A-4317-B7A7-4E85D9C0E386",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:*",
"matchCriteriaId": "2F495722-39BD-4BA1-A643-C7D0BA81CC21",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:*",
"matchCriteriaId": "7B776512-BF3D-4F70-BD58-AFF8E1B03EE2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:*",
"matchCriteriaId": "99E05299-50FD-4292-9978-8E05C1483FE2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:*",
"matchCriteriaId": "2447D05B-2634-4895-B7B0-6F7DBB9D2EC2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:*",
"matchCriteriaId": "CBBD39F3-790F-4017-A57E-6EFC314F0557",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:*",
"matchCriteriaId": "B4387BFA-8A98-433E-9EF7-B29226C195A7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:*",
"matchCriteriaId": "9E380F66-C11C-472B-9B71-7CB4AF4FABDC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack9:*:*:*:*:*:*",
"matchCriteriaId": "0CF4ACE1-B069-4007-8142-7F90015BBE9D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*",
"matchCriteriaId": "39D237BD-EE55-4B40-ABC3-194C4BF7C6CD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*",
"matchCriteriaId": "49F5649A-349C-42C6-AFFF-CEE1ABC14E67",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*",
"matchCriteriaId": "756343AA-DB57-40F7-94FA-84BFCDEB6159",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*",
"matchCriteriaId": "36B0DD28-653E-4069-AB5A-38F8EFEB36CA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP13), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP4). Las aplicaciones afectadas carecen de una comprobaci\u00f3n apropiada de los datos proporcionados por el usuario cuando se analizan archivos PAR. Esto podr\u00eda resultar en una escritura fuera de l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-12532)"
}
],
"id": "CVE-2021-27380",
"lastModified": "2024-11-21T05:57:52.740",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-03-15T17:15:22.207",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
ICSA-21-103-06
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Trend Micro Zero Day Initiative",
"summary": "coordinated disclosure"
},
{
"organization": "Cybersecurity and Infrastructure Security Agency (CISA)",
"summary": "coordination efforts"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Siemens has released a new version for Solid Edge to fix multiple vulnerabilities that could be triggered when the application reads files in different file formats (PAR, DFT extensions). If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and potentially also to arbitrary code execution or data extraction on the target host system.\n\nSiemens recommends to update to the latest version and to avoid opening of untrusted files from unknown sources.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-574442: Multiple PAR and DFT File Parsing Vulnerabilities in Solid Edge - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-574442.json"
},
{
"category": "self",
"summary": "SSA-574442: Multiple PAR and DFT File Parsing Vulnerabilities in Solid Edge - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-574442.txt"
},
{
"category": "self",
"summary": "SSA-574442: Multiple PAR and DFT File Parsing Vulnerabilities in Solid Edge - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-103-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-103-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-103-06 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-103-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Solid Edge File Parsing (Update A)",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-103-06",
"initial_release_date": "2021-04-13T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-04-13T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2021-06-08T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Updated remediation for CVE-2020-26997, CVE-2021-25678 and CVE-2021-27382"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "3",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSE2020MP13",
"product": {
"name": "Solid Edge SE2020",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2020"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSE2020MP14",
"product": {
"name": "Solid Edge SE2020",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2020"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSE2021MP4",
"product": {
"name": "Solid Edge SE2021",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2021"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-26997",
"cwe": {
"id": "CWE-822",
"name": "Untrusted Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2020-26997 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-26997.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2020MP14 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2020-26997"
},
{
"cve": "CVE-2020-28385",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2020-28385 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28385.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2020-28385"
},
{
"cve": "CVE-2021-25678",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2021-25678 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25678.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2020MP14 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2021-25678"
},
{
"cve": "CVE-2021-27380",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2021-27380 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27380.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2021-27380"
},
{
"cve": "CVE-2021-27382",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2021-27382 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27382.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2020MP14 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2021-27382"
}
]
}
icsa-21-103-06
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Trend Micro Zero Day Initiative",
"summary": "coordinated disclosure"
},
{
"organization": "Cybersecurity and Infrastructure Security Agency (CISA)",
"summary": "coordination efforts"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Siemens has released a new version for Solid Edge to fix multiple vulnerabilities that could be triggered when the application reads files in different file formats (PAR, DFT extensions). If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and potentially also to arbitrary code execution or data extraction on the target host system.\n\nSiemens recommends to update to the latest version and to avoid opening of untrusted files from unknown sources.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-574442: Multiple PAR and DFT File Parsing Vulnerabilities in Solid Edge - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-574442.json"
},
{
"category": "self",
"summary": "SSA-574442: Multiple PAR and DFT File Parsing Vulnerabilities in Solid Edge - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-574442.txt"
},
{
"category": "self",
"summary": "SSA-574442: Multiple PAR and DFT File Parsing Vulnerabilities in Solid Edge - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-103-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-103-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-103-06 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-103-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Solid Edge File Parsing (Update A)",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-103-06",
"initial_release_date": "2021-04-13T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-04-13T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2021-06-08T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Updated remediation for CVE-2020-26997, CVE-2021-25678 and CVE-2021-27382"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "3",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSE2020MP13",
"product": {
"name": "Solid Edge SE2020",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2020"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSE2020MP14",
"product": {
"name": "Solid Edge SE2020",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2020"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSE2021MP4",
"product": {
"name": "Solid Edge SE2021",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2021"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-26997",
"cwe": {
"id": "CWE-822",
"name": "Untrusted Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2020-26997 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-26997.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2020MP14 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2020-26997"
},
{
"cve": "CVE-2020-28385",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2020-28385 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28385.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2020-28385"
},
{
"cve": "CVE-2021-25678",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2021-25678 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25678.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2020MP14 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2021-25678"
},
{
"cve": "CVE-2021-27380",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2021-27380 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27380.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0003"
]
}
],
"title": "CVE-2021-27380"
},
{
"cve": "CVE-2021-27382",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2021-27382 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27382.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2020MP14 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2021-27382"
}
]
}
ICSA-21-068-09
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
},
{
"organization": "Trend Micro Zero Day Initiative",
"summary": "coordinated disclosure"
},
{
"organization": "Cybersecurity and Infrastructure Security Agency (CISA)",
"summary": "coordination efforts"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Siemens has released new versions for Solid Edge to fix multiple vulnerabilities that could be triggered when the application reads files in different file formats (PAR, DFT, XML extensions). If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and potentially also to arbitrary code execution or data extraction on the target host system.\n\nSiemens recommends to update to the latest version and to avoid opening of untrusted files from unknown sources. Please refer to SSA-574442 for further information regarding latest version update.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-715184.json"
},
{
"category": "self",
"summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-715184.txt"
},
{
"category": "self",
"summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-068-09 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-068-09.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-068-09 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-068-09"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Solid Edge File Parsing",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-068-09",
"initial_release_date": "2021-03-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-03-09T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2021-04-13T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Included fix information for CVE-2020-28385 and CVE-2021-27380, and reference to new advisory SSA-574442"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "3",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSE2020MP13",
"product": {
"name": "Solid Edge SE2020",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2020"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSE2021MP3",
"product": {
"name": "Solid Edge SE2021",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2021"
},
{
"branches": [
{
"category": "product_version_range",
"name": "SE2021MP3",
"product": {
"name": "Solid Edge SE2021",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2021"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-28385",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2020-28385 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28385.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP3 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2020-28385"
},
{
"cve": "CVE-2020-28387",
"cwe": {
"id": "CWE-611",
"name": "Improper Restriction of XML External Entity Reference"
},
"notes": [
{
"category": "summary",
"text": "When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2020-28387 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28387.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP3 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2020-28387"
},
{
"cve": "CVE-2021-27380",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2021-27380 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27380.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP3 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2021-27380"
},
{
"cve": "CVE-2021-27381",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2021-27381 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27381.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP3 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-27381"
}
]
}
icsa-21-068-09
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
},
{
"organization": "Trend Micro Zero Day Initiative",
"summary": "coordinated disclosure"
},
{
"organization": "Cybersecurity and Infrastructure Security Agency (CISA)",
"summary": "coordination efforts"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Siemens has released new versions for Solid Edge to fix multiple vulnerabilities that could be triggered when the application reads files in different file formats (PAR, DFT, XML extensions). If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and potentially also to arbitrary code execution or data extraction on the target host system.\n\nSiemens recommends to update to the latest version and to avoid opening of untrusted files from unknown sources. Please refer to SSA-574442 for further information regarding latest version update.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-715184.json"
},
{
"category": "self",
"summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-715184.txt"
},
{
"category": "self",
"summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-068-09 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-068-09.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-068-09 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-068-09"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens Solid Edge File Parsing",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-068-09",
"initial_release_date": "2021-03-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-03-09T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2021-04-13T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Included fix information for CVE-2020-28385 and CVE-2021-27380, and reference to new advisory SSA-574442"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "3",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSE2020MP13",
"product": {
"name": "Solid Edge SE2020",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2020"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cSE2021MP3",
"product": {
"name": "Solid Edge SE2021",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2021"
},
{
"branches": [
{
"category": "product_version_range",
"name": "SE2021MP3",
"product": {
"name": "Solid Edge SE2021",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2021"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-28385",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2020-28385 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28385.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP3 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2020-28385"
},
{
"cve": "CVE-2020-28387",
"cwe": {
"id": "CWE-611",
"name": "Improper Restriction of XML External Entity Reference"
},
"notes": [
{
"category": "summary",
"text": "When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2020-28387 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28387.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP3 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2020-28387"
},
{
"cve": "CVE-2021-27380",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"summary": "CVE-2021-27380 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27380.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP3 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP4 or later version",
"product_ids": [
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"title": "CVE-2021-27380"
},
{
"cve": "CVE-2021-27381",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2021-27381 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27381.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to SE2020MP13 or later version",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to SE2021MP3 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in Solid Edge",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-27381"
}
]
}
CERTFR-2021-AVI-176
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SENTRON PAC3200 versions antérieures à 2.4.7 | ||
| Siemens | N/A | SENTRON 3VA COM100/800, 3VA DSP800, PAC2200 toutes versions | ||
| Siemens | N/A | SCALANCE XM400 et XR500 versions antérieures à 6.2 | ||
| Siemens | N/A | SIMATIC S7-PLCSIM version 5.4 | ||
| Siemens | N/A | RUGGEDCOM RM1224, SCALANCE M-800 et Scalance S615 versions 4.3 et ultérieures | ||
| Siemens | N/A | SENTRON PAC3220 versions antérieures à 3.2.0 | ||
| Siemens | N/A | module Mendix Forgot Password versions antérieures à 3.2.1 | ||
| Siemens | N/A | SIMATIC NET CM 1542-1 toutes versions | ||
| Siemens | N/A | Solid Edge SE2020 versions antérieures à SE2020MP13 | ||
| Siemens | N/A | SINEMA remote connect server versions antérieures à 3.0 | ||
| Siemens | N/A | SCALANCE SC-600 versions antérieures à 2.1.3 | ||
| Siemens | N/A | LOGO! 8 BM toutes versions (y compris les versions SIPLUS) | ||
| Siemens | N/A | PLUSCONTROL 1st Gen toutes versions | ||
| Siemens | N/A | SENTRON PAC4200 versions antérieures à 2.3.0 | ||
| Siemens | N/A | Luxion KeyShot versions antérieures à 10.1 | ||
| Siemens | N/A | SCALANCE X300WG et Xx200 versions antérieures à 4.1 | ||
| Siemens | N/A | SIMATIC MV400 versions antérieures à 7.0.6 | ||
| Siemens | N/A | Solid Edge SE2021 versions antérieures à SE2021MP3 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SENTRON PAC3200 versions ant\u00e9rieures \u00e0 2.4.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON 3VA COM100/800, 3VA DSP800, PAC2200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM400 et XR500 versions ant\u00e9rieures \u00e0 6.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-PLCSIM version 5.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RM1224, SCALANCE M-800 et Scalance S615 versions 4.3 et ult\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON PAC3220 versions ant\u00e9rieures \u00e0 3.2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "module Mendix Forgot Password versions ant\u00e9rieures \u00e0 3.2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CM 1542-1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2020 versions ant\u00e9rieures \u00e0 SE2020MP13",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA remote connect server versions ant\u00e9rieures \u00e0 3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC-600 versions ant\u00e9rieures \u00e0 2.1.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO! 8 BM toutes versions (y compris les versions SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PLUSCONTROL 1st Gen toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON PAC4200 versions ant\u00e9rieures \u00e0 2.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Luxion KeyShot versions ant\u00e9rieures \u00e0 10.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X300WG et Xx200 versions ant\u00e9rieures \u00e0 4.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV400 versions ant\u00e9rieures \u00e0 7.0.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2021 versions ant\u00e9rieures \u00e0 SE2021MP3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-25667",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25667"
},
{
"name": "CVE-2020-28388",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28388"
},
{
"name": "CVE-2021-27381",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27381"
},
{
"name": "CVE-2021-25673",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25673"
},
{
"name": "CVE-2020-28387",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28387"
},
{
"name": "CVE-2020-25241",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25241"
},
{
"name": "CVE-2021-22647",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22647"
},
{
"name": "CVE-2021-22643",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22643"
},
{
"name": "CVE-2021-25672",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25672"
},
{
"name": "CVE-2021-27380",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27380"
},
{
"name": "CVE-2021-22649",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22649"
},
{
"name": "CVE-2021-22651",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22651"
},
{
"name": "CVE-2021-25676",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25676"
},
{
"name": "CVE-2021-25674",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25674"
},
{
"name": "CVE-2021-22645",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22645"
},
{
"name": "CVE-2019-3823",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-3823"
},
{
"name": "CVE-2020-28385",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28385"
},
{
"name": "CVE-2019-10926",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10926"
},
{
"name": "CVE-2020-13987",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13987"
},
{
"name": "CVE-2020-27632",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27632"
},
{
"name": "CVE-2020-25239",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25239"
},
{
"name": "CVE-2020-25236",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25236"
},
{
"name": "CVE-2021-25675",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25675"
},
{
"name": "CVE-2020-25240",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25240"
},
{
"name": "CVE-2019-10925",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10925"
},
{
"name": "CVE-2020-17437",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-17437"
}
],
"initial_release_date": "2021-03-10T00:00:00",
"last_revision_date": "2021-03-10T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-176",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-03-10T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-599268 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599268.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-979775 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-541018 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-715184 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-936080 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-936080.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-231216 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-231216.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-783481 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-296266 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-296266.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-731317 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731317.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-256092 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-344238 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-917115 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917115.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-816980 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
}
]
}
CERTFR-2021-AVI-255
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | LOGO! Soft Comfort toutes versions | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2019 R2 | ||
| Siemens | N/A | Solid Edge SE2021 versions antérieures à SE2021MP4 | ||
| Siemens | N/A | SIMATIC NET CP 443-1 Advanced (incl. SIPLUSvariants) versions antérieures à V3.2.9 | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2019 R3 | ||
| Siemens | N/A | Nucleus NET versions antérieures à 5.2 | ||
| Siemens | N/A | TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUSNET variants) versions antérieures à V2.6.0 | ||
| Siemens | N/A | SiNVR/SiVMS Video Server toutes versions | ||
| Siemens | N/A | Nucleus RTOS versions contenant le module DNS affecté | ||
| Siemens | N/A | SIMATIC NET CP 343-1 Advanced (incl. SIPLUSvariants) versions antérieures à V3.0.44 | ||
| Siemens | N/A | Solid Edge SE2020 toutes versions | ||
| Siemens | N/A | SIMATIC NET CP 343-1 Lean (incl. SIPLUS vari-ants) versions antérieures à V3.1.1 | ||
| Siemens | N/A | SIMATIC NET CP 443-5 Basic (incl. SIPLUS vari-ants) toutes versions | ||
| Siemens | N/A | Opcenter Quality versions antérieures à 12.2 | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2019 R1 | ||
| Siemens | N/A | SIMATIC NET CP 443-5 Extended toutes versions | ||
| Siemens | N/A | VSTAR versions contenant le module DNS affecté | ||
| Siemens | N/A | Control Center Server (CCS) toutes versions | ||
| Siemens | N/A | TIM 4R-IE (incl. SIPLUS NET variants) toutes versions | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2020 R1 | ||
| Siemens | N/A | SINEMA Remote Connect Server versions antérieures à 3.0 | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2020 R2 | ||
| Siemens | N/A | SIMATIC NET CP 343-1 Standard (incl. SIPLUSvariants) versions antérieures à V3.1.1 | ||
| Siemens | N/A | SIMATIC NET CP 443-1 Standard (incl. SIPLUSvariants) versions antérieures à V3.2.9 | ||
| Siemens | N/A | SIMATIC NET CP 342-5 (incl. SIPLUS variants) toutes versions | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2018 R2 | ||
| Siemens | N/A | Nucleus ReadyStart toutes versions | ||
| Siemens | N/A | Nucleus 4 versions antérieures à 4.1.0 | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2018 R3 | ||
| Siemens | N/A | QMS Automotive versions antérieures à 12.30 | ||
| Siemens | N/A | Tecnomatix RobotExpert versions antérieures à 16.1 | ||
| Siemens | N/A | TIM 3V-IE DNP3 (incl. SIPLUS NET variants) versions antérieures à V3.1.0 | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2020 R3 | ||
| Siemens | N/A | Nucleus Source Code versions contenant le module DNS affecté | ||
| Siemens | N/A | TIM 4R-IE DNP3 (incl. SIPLUS NET variants) toutes versions | ||
| Siemens | N/A | SIMOTICS CONNECT 400 toutes verions |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "LOGO! Soft Comfort toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2019 R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2021 versions ant\u00e9rieures \u00e0 SE2021MP4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 443-1 Advanced (incl. SIPLUSvariants) versions ant\u00e9rieures \u00e0 V3.2.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2019 R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus NET versions ant\u00e9rieures \u00e0 5.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUSNET variants) versions ant\u00e9rieures \u00e0 V2.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiNVR/SiVMS Video Server toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus RTOS versions contenant le module DNS affect\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 343-1 Advanced (incl. SIPLUSvariants) versions ant\u00e9rieures \u00e0 V3.0.44",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2020 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 343-1 Lean (incl. SIPLUS vari-ants) versions ant\u00e9rieures \u00e0 V3.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 443-5 Basic (incl. SIPLUS vari-ants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Opcenter Quality versions ant\u00e9rieures \u00e0 12.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2019 R1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 443-5 Extended toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "VSTAR versions contenant le module DNS affect\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Control Center Server (CCS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 4R-IE (incl. SIPLUS NET variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2020 R1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA Remote Connect Server versions ant\u00e9rieures \u00e0 3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2020 R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 343-1 Standard (incl. SIPLUSvariants) versions ant\u00e9rieures \u00e0 V3.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 443-1 Standard (incl. SIPLUSvariants) versions ant\u00e9rieures \u00e0 V3.2.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 342-5 (incl. SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2018 R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus ReadyStart toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus 4 versions ant\u00e9rieures \u00e0 4.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2018 R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "QMS Automotive versions ant\u00e9rieures \u00e0 12.30",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix RobotExpert versions ant\u00e9rieures \u00e0 16.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 3V-IE DNP3 (incl. SIPLUS NET variants) versions ant\u00e9rieures \u00e0 V3.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2020 R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus Source Code versions contenant le module DNS affect\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 4R-IE DNP3 (incl. SIPLUS NET variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTICS CONNECT 400 toutes verions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-27009",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27009"
},
{
"name": "CVE-2015-7855",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7855"
},
{
"name": "CVE-2019-18339",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18339"
},
{
"name": "CVE-2016-1547",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-1547"
},
{
"name": "CVE-2015-7973",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7973"
},
{
"name": "CVE-2016-4953",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-4953"
},
{
"name": "CVE-2021-27389",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27389"
},
{
"name": "CVE-2021-27382",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27382"
},
{
"name": "CVE-2020-27736",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27736"
},
{
"name": "CVE-2021-27380",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27380"
},
{
"name": "CVE-2015-5219",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-5219"
},
{
"name": "CVE-2016-1550",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-1550"
},
{
"name": "CVE-2015-7977",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7977"
},
{
"name": "CVE-2015-7705",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7705"
},
{
"name": "CVE-2021-27392",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27392"
},
{
"name": "CVE-2019-19956",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19956"
},
{
"name": "CVE-2021-25663",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25663"
},
{
"name": "CVE-2020-15795",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-15795"
},
{
"name": "CVE-2015-8138",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-8138"
},
{
"name": "CVE-2016-4954",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-4954"
},
{
"name": "CVE-2021-25664",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25664"
},
{
"name": "CVE-2020-25243",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25243"
},
{
"name": "CVE-2015-7974",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7974"
},
{
"name": "CVE-2015-8214",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-8214"
},
{
"name": "CVE-2019-19299",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19299"
},
{
"name": "CVE-2020-28385",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28385"
},
{
"name": "CVE-2021-25678",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25678"
},
{
"name": "CVE-2020-7595",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7595"
},
{
"name": "CVE-2021-27393",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27393"
},
{
"name": "CVE-2020-25244",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25244"
},
{
"name": "CVE-2019-18340",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18340"
},
{
"name": "CVE-2021-25670",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25670"
},
{
"name": "CVE-2015-7979",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7979"
},
{
"name": "CVE-2015-7871",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7871"
},
{
"name": "CVE-2020-27738",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27738"
},
{
"name": "CVE-2019-19298",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19298"
},
{
"name": "CVE-2020-26997",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26997"
},
{
"name": "CVE-2019-19291",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19291"
},
{
"name": "CVE-2020-27737",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27737"
},
{
"name": "CVE-2019-19297",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19297"
},
{
"name": "CVE-2016-1548",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-1548"
},
{
"name": "CVE-2021-25677",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25677"
},
{
"name": "CVE-2019-19296",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19296"
}
],
"initial_release_date": "2021-04-14T00:00:00",
"last_revision_date": "2021-04-14T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-255",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-04-14T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service et un\ncontournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-788287 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-788287.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-248289 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-853866 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853866.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-185699 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-983300 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-983300.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-844761 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-163226 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-163226.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-763427 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-763427.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-497656 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-497656.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-761617 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-669158 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-574442 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-705111 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-292794 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-292794.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-761844 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
]
}
ghsa-pfjr-ff58-8j7x
Vulnerability from github
A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3), Solid Edge SE2021 (SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)
{
"affected": [],
"aliases": [
"CVE-2021-27380"
],
"database_specific": {
"cwe_ids": [
"CWE-787"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-03-15T17:15:00Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3), Solid Edge SE2021 (SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)",
"id": "GHSA-pfjr-ff58-8j7x",
"modified": "2022-05-24T17:44:35Z",
"published": "2022-05-24T17:44:35Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-27380"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"type": "WEB",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
],
"schema_version": "1.4.0",
"severity": []
}
gsd-2021-27380
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2021-27380",
"description": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)",
"id": "GSD-2021-27380"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-27380"
],
"details": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)",
"id": "GSD-2021-27380",
"modified": "2023-12-13T01:23:36.220762Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-27380",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Solid Edge SE2020",
"version": {
"version_data": [
{
"version_value": "All versions \u003c SE2020MP13"
}
]
}
},
{
"product_name": "Solid Edge SE2021",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c SE2021MP4"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "se2020",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack10:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack11:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack12:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack9:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-27380"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
"refsource": "CONFIRM",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
"refsource": "CONFIRM",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2021-12-10T21:32Z",
"publishedDate": "2021-03-15T17:15Z"
}
}
}
var-202103-1585
Vulnerability from variot
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532). Zero Day Initiative To this vulnerability ZDI-CAN-12532 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files
Show details on source website{
"affected_products": {
"_id": null,
"data": [
{
"_id": null,
"model": "solid edge",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "se2021"
},
{
"_id": null,
"model": "solid edge",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "se2020"
},
{
"_id": null,
"model": "solid edge",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "se2020"
},
{
"_id": null,
"model": "solid edge",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "se2021mp4"
},
{
"_id": null,
"model": "solid edge",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "se2020mp13"
},
{
"_id": null,
"model": "solid edge",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"_id": null,
"model": "solid edge viewer",
"scope": null,
"trust": 0.7,
"vendor": "siemens",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-274"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004476"
},
{
"db": "NVD",
"id": "CVE-2021-27380"
}
]
},
"configurations": {
"_id": null,
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "se2020",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack10:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack11:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack12:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack9:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-27380"
}
]
},
"credits": {
"_id": null,
"data": "Francis Provencher {PRL}",
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-274"
}
],
"trust": 0.7
},
"cve": "CVE-2021-27380",
"cvss": {
"_id": null,
"data": [
{
"cvssV2": [
{
"acInsufInfo": null,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "CVE-2021-27380",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "MEDIUM",
"trust": 1.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2021-27380",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-27380",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2021-27380",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-27380",
"trust": 1.8,
"value": "High"
},
{
"author": "ZDI",
"id": "CVE-2021-27380",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202103-697",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2021-27380",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-274"
},
{
"db": "VULMON",
"id": "CVE-2021-27380"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004476"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-697"
},
{
"db": "NVD",
"id": "CVE-2021-27380"
}
]
},
"description": {
"_id": null,
"data": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532). Zero Day Initiative To this vulnerability ZDI-CAN-12532 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-27380"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004476"
},
{
"db": "ZDI",
"id": "ZDI-21-274"
},
{
"db": "VULMON",
"id": "CVE-2021-27380"
}
],
"trust": 2.34
},
"external_ids": {
"_id": null,
"data": [
{
"db": "NVD",
"id": "CVE-2021-27380",
"trust": 3.2
},
{
"db": "ICS CERT",
"id": "ICSA-21-103-06",
"trust": 2.5
},
{
"db": "SIEMENS",
"id": "SSA-574442",
"trust": 1.7
},
{
"db": "SIEMENS",
"id": "SSA-715184",
"trust": 1.7
},
{
"db": "ZDI",
"id": "ZDI-21-274",
"trust": 1.4
},
{
"db": "JVN",
"id": "JVNVU93441670",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU96269392",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004476",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-12532",
"trust": 0.7
},
{
"db": "AUSCERT",
"id": "ESB-2021.1244",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2021.0854",
"trust": 0.6
},
{
"db": "ICS CERT",
"id": "ICSA-21-068-09",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202103-697",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2021-27380",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-274"
},
{
"db": "VULMON",
"id": "CVE-2021-27380"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004476"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-697"
},
{
"db": "NVD",
"id": "CVE-2021-27380"
}
]
},
"id": "VAR-202103-1585",
"iot": {
"_id": null,
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.19128205
},
"last_update_date": "2022-05-04T06:53:34.594000Z",
"patch": {
"_id": null,
"data": [
{
"title": "SSA-574442 Siemens\u00a0Security\u00a0Advisory",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"title": "Siemens has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-09"
},
{
"title": "Siemens Security Advisories: Siemens Security Advisory",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=1b3f65b08c80e38048cc09f548b68a84"
},
{
"title": "Siemens Security Advisories: Siemens Security Advisory",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=eaf7ce45c295beb8a23b24ef0efbaa1c"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-274"
},
{
"db": "VULMON",
"id": "CVE-2021-27380"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004476"
}
]
},
"problemtype_data": {
"_id": null,
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [ Other ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004476"
},
{
"db": "NVD",
"id": "CVE-2021-27380"
}
]
},
"references": {
"_id": null,
"data": [
{
"trust": 3.1,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
},
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-27380"
},
{
"trust": 1.3,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-09"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu93441670/"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu96269392/"
},
{
"trust": 0.7,
"url": "https://www.zerodayinitiative.com/advisories/zdi-21-274/"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.1244"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.0854"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-574442.txt"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-274"
},
{
"db": "VULMON",
"id": "CVE-2021-27380"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004476"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-697"
},
{
"db": "NVD",
"id": "CVE-2021-27380"
}
]
},
"sources": {
"_id": null,
"data": [
{
"db": "ZDI",
"id": "ZDI-21-274",
"ident": null
},
{
"db": "VULMON",
"id": "CVE-2021-27380",
"ident": null
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004476",
"ident": null
},
{
"db": "CNNVD",
"id": "CNNVD-202103-697",
"ident": null
},
{
"db": "NVD",
"id": "CVE-2021-27380",
"ident": null
}
]
},
"sources_release_date": {
"_id": null,
"data": [
{
"date": "2021-03-11T00:00:00",
"db": "ZDI",
"id": "ZDI-21-274",
"ident": null
},
{
"date": "2021-03-15T00:00:00",
"db": "VULMON",
"id": "CVE-2021-27380",
"ident": null
},
{
"date": "2021-11-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-004476",
"ident": null
},
{
"date": "2021-03-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-697",
"ident": null
},
{
"date": "2021-03-15T17:15:00",
"db": "NVD",
"id": "CVE-2021-27380",
"ident": null
}
]
},
"sources_update_date": {
"_id": null,
"data": [
{
"date": "2021-03-11T00:00:00",
"db": "ZDI",
"id": "ZDI-21-274",
"ident": null
},
{
"date": "2021-04-22T00:00:00",
"db": "VULMON",
"id": "CVE-2021-27380",
"ident": null
},
{
"date": "2021-11-22T09:03:00",
"db": "JVNDB",
"id": "JVNDB-2021-004476",
"ident": null
},
{
"date": "2021-06-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-697",
"ident": null
},
{
"date": "2021-12-10T21:32:00",
"db": "NVD",
"id": "CVE-2021-27380",
"ident": null
}
]
},
"threat_type": {
"_id": null,
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-697"
}
],
"trust": 0.6
},
"title": {
"_id": null,
"data": "Solid\u00a0Edge\u00a0 Out-of-bounds Vulnerability in Microsoft",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004476"
}
],
"trust": 0.8
},
"type": {
"_id": null,
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-697"
}
],
"trust": 0.6
}
}
cnvd-2021-16439
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf
| Name | Siemens Solid Edge SE2021 SE2021MP3 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2021-27380"
}
},
"description": "Siemens Solid Edge\u662f\u5fb7\u56fdSiemens\u516c\u53f8\u7684\u4e00\u6b3e\u4e09\u7ef4CAD\u8f6f\u4ef6\u3002\u8be5\u8f6f\u4ef6\u53ef\u7528\u4e8e\u96f6\u4ef6\u8bbe\u8ba1\u3001\u88c5\u914d\u8bbe\u8ba1\u3001\u94a3\u91d1\u8bbe\u8ba1\u3001\u710a\u63a5\u8bbe\u8ba1\u7b49\u884c\u4e1a\u3002\n\nSiemens Solid Edge\u5b58\u5728\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\u3002\u8be5\u6f0f\u6d1e\u662f\u7531\u4e8e\u53d7\u5f71\u54cd\u7684\u5e94\u7528\u7a0b\u5e8f\u5728\u89e3\u6790PAR\u6587\u4ef6\u65f6\u7f3a\u5c11\u5bf9\u7528\u6237\u63d0\u4f9b\u7684\u6570\u636e\u7684\u6b63\u786e\u9a8c\u8bc1\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6b64\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-16439",
"openTime": "2021-03-11",
"patchDescription": "Siemens Solid Edge\u662f\u5fb7\u56fdSiemens\u516c\u53f8\u7684\u4e00\u6b3e\u4e09\u7ef4CAD\u8f6f\u4ef6\u3002\u8be5\u8f6f\u4ef6\u53ef\u7528\u4e8e\u96f6\u4ef6\u8bbe\u8ba1\u3001\u88c5\u914d\u8bbe\u8ba1\u3001\u94a3\u91d1\u8bbe\u8ba1\u3001\u710a\u63a5\u8bbe\u8ba1\u7b49\u884c\u4e1a\u3002\r\n\r\nSiemens Solid Edge\u5b58\u5728\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\u3002\u8be5\u6f0f\u6d1e\u662f\u7531\u4e8e\u53d7\u5f71\u54cd\u7684\u5e94\u7528\u7a0b\u5e8f\u5728\u89e3\u6790PAR\u6587\u4ef6\u65f6\u7f3a\u5c11\u5bf9\u7528\u6237\u63d0\u4f9b\u7684\u6570\u636e\u7684\u6b63\u786e\u9a8c\u8bc1\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6b64\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens Solid Edge\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\uff08CNVD-2021-16439\uff09\u7684\u8865\u4e01",
"products": {
"product": "Siemens Solid Edge SE2021 SE2021MP3"
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
"serverity": "\u9ad8",
"submitTime": "2021-03-09",
"title": "Siemens Solid Edge\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\uff08CNVD-2021-16439\uff09"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.