Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2021-25675 (GCVE-0-2021-25675)
Vulnerability from cvelistv5
- CWE-369 - Divide By Zero
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | SIMATIC S7-PLCSIM V5.4 |
Version: All versions |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:11:28.318Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC S7-PLCSIM V5.4",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-369",
"description": "CWE-369: Divide By Zero",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-15T17:03:31",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-25675",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC S7-PLCSIM V5.4",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-369: Divide By Zero"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-25675",
"datePublished": "2021-03-15T17:03:31",
"dateReserved": "2021-01-21T00:00:00",
"dateUpdated": "2024-08-03T20:11:28.318Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2021-25675\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-03-15T17:15:22.003\",\"lastModified\":\"2024-11-21T05:55:16.547\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC S7-PLCSIM versi\u00f3n V5.4 (todas las versiones).\u0026#xa0;Un atacante con acceso local al sistema podr\u00eda causar una condici\u00f3n de Denegaci\u00f3n de Servicio en la aplicaci\u00f3n cuando es usada para abrir un archivo especialmente dise\u00f1ado.\u0026#xa0;Como consecuencia, podr\u00eda ocurrir una operaci\u00f3n de divisi\u00f3n por cero y causar a la aplicaci\u00f3n finalizar inesperadamente y deba reiniciarse para restaurar el servicio\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":2.1,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-369\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_s7-plcsim:5.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F5964421-8D14-4D38-B36A-EFC0E676BE65\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
icsa-21-068-01
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from a Siemens ProductCERT\u0027s advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-256092: Multiple local Denial-of-Service Vulnerabilities in SIMATIC S7-PLCSIM\n V5.4 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-256092.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-068-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-068-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-068-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-068-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC S7-PLCSIM",
"tracking": {
"current_release_date": "2021-03-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-068-01",
"initial_release_date": "2021-03-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-03-09T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Siemens SIMATIC S7-PLCSIM V5.4: All versions",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-PLCSIM V5.4"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-25673",
"cwe": {
"id": "CWE-835",
"name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to project files on the engineering station to trusted users.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Only use project files from trusted sources.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-25673"
},
{
"cve": "CVE-2021-25674",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to project files on the engineering station to trusted users.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Only use project files from trusted sources.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-25674"
},
{
"cve": "CVE-2021-25675",
"cwe": {
"id": "CWE-369",
"name": "Divide By Zero"
},
"notes": [
{
"category": "summary",
"text": "An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to project files on the engineering station to trusted users.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Only use project files from trusted sources.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-25675"
}
]
}
ICSA-21-068-01
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.",
"title": "General Recommendations"
},
{
"category": "general",
"text": "Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from a Siemens ProductCERT\u0027s advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-256092: Multiple local Denial-of-Service Vulnerabilities in SIMATIC S7-PLCSIM\n V5.4 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-256092.html"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-068-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-068-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-068-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-068-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC S7-PLCSIM",
"tracking": {
"current_release_date": "2021-03-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-068-01",
"initial_release_date": "2021-03-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-03-09T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Siemens SIMATIC S7-PLCSIM V5.4: All versions",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-PLCSIM V5.4"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-25673",
"cwe": {
"id": "CWE-835",
"name": "Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to project files on the engineering station to trusted users.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Only use project files from trusted sources.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-25673"
},
{
"cve": "CVE-2021-25674",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to project files on the engineering station to trusted users.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Only use project files from trusted sources.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-25674"
},
{
"cve": "CVE-2021-25675",
"cwe": {
"id": "CWE-369",
"name": "Divide By Zero"
},
"notes": [
{
"category": "summary",
"text": "An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Restrict access to project files on the engineering station to trusted users.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Only use project files from trusted sources.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:W/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2021-25675"
}
]
}
CERTFR-2021-AVI-176
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SENTRON PAC3200 versions antérieures à 2.4.7 | ||
| Siemens | N/A | SENTRON 3VA COM100/800, 3VA DSP800, PAC2200 toutes versions | ||
| Siemens | N/A | SCALANCE XM400 et XR500 versions antérieures à 6.2 | ||
| Siemens | N/A | SIMATIC S7-PLCSIM version 5.4 | ||
| Siemens | N/A | RUGGEDCOM RM1224, SCALANCE M-800 et Scalance S615 versions 4.3 et ultérieures | ||
| Siemens | N/A | SENTRON PAC3220 versions antérieures à 3.2.0 | ||
| Siemens | N/A | module Mendix Forgot Password versions antérieures à 3.2.1 | ||
| Siemens | N/A | SIMATIC NET CM 1542-1 toutes versions | ||
| Siemens | N/A | Solid Edge SE2020 versions antérieures à SE2020MP13 | ||
| Siemens | N/A | SINEMA remote connect server versions antérieures à 3.0 | ||
| Siemens | N/A | SCALANCE SC-600 versions antérieures à 2.1.3 | ||
| Siemens | N/A | LOGO! 8 BM toutes versions (y compris les versions SIPLUS) | ||
| Siemens | N/A | PLUSCONTROL 1st Gen toutes versions | ||
| Siemens | N/A | SENTRON PAC4200 versions antérieures à 2.3.0 | ||
| Siemens | N/A | Luxion KeyShot versions antérieures à 10.1 | ||
| Siemens | N/A | SCALANCE X300WG et Xx200 versions antérieures à 4.1 | ||
| Siemens | N/A | SIMATIC MV400 versions antérieures à 7.0.6 | ||
| Siemens | N/A | Solid Edge SE2021 versions antérieures à SE2021MP3 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SENTRON PAC3200 versions ant\u00e9rieures \u00e0 2.4.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON 3VA COM100/800, 3VA DSP800, PAC2200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM400 et XR500 versions ant\u00e9rieures \u00e0 6.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-PLCSIM version 5.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RM1224, SCALANCE M-800 et Scalance S615 versions 4.3 et ult\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON PAC3220 versions ant\u00e9rieures \u00e0 3.2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "module Mendix Forgot Password versions ant\u00e9rieures \u00e0 3.2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CM 1542-1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2020 versions ant\u00e9rieures \u00e0 SE2020MP13",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA remote connect server versions ant\u00e9rieures \u00e0 3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC-600 versions ant\u00e9rieures \u00e0 2.1.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO! 8 BM toutes versions (y compris les versions SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PLUSCONTROL 1st Gen toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON PAC4200 versions ant\u00e9rieures \u00e0 2.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Luxion KeyShot versions ant\u00e9rieures \u00e0 10.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X300WG et Xx200 versions ant\u00e9rieures \u00e0 4.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV400 versions ant\u00e9rieures \u00e0 7.0.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2021 versions ant\u00e9rieures \u00e0 SE2021MP3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-25667",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25667"
},
{
"name": "CVE-2020-28388",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28388"
},
{
"name": "CVE-2021-27381",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27381"
},
{
"name": "CVE-2021-25673",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25673"
},
{
"name": "CVE-2020-28387",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28387"
},
{
"name": "CVE-2020-25241",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25241"
},
{
"name": "CVE-2021-22647",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22647"
},
{
"name": "CVE-2021-22643",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22643"
},
{
"name": "CVE-2021-25672",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25672"
},
{
"name": "CVE-2021-27380",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27380"
},
{
"name": "CVE-2021-22649",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22649"
},
{
"name": "CVE-2021-22651",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22651"
},
{
"name": "CVE-2021-25676",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25676"
},
{
"name": "CVE-2021-25674",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25674"
},
{
"name": "CVE-2021-22645",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22645"
},
{
"name": "CVE-2019-3823",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-3823"
},
{
"name": "CVE-2020-28385",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28385"
},
{
"name": "CVE-2019-10926",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10926"
},
{
"name": "CVE-2020-13987",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13987"
},
{
"name": "CVE-2020-27632",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27632"
},
{
"name": "CVE-2020-25239",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25239"
},
{
"name": "CVE-2020-25236",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25236"
},
{
"name": "CVE-2021-25675",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25675"
},
{
"name": "CVE-2020-25240",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25240"
},
{
"name": "CVE-2019-10925",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10925"
},
{
"name": "CVE-2020-17437",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-17437"
}
],
"initial_release_date": "2021-03-10T00:00:00",
"last_revision_date": "2021-03-10T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-176",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-03-10T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-599268 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599268.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-979775 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-541018 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-715184 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-936080 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-936080.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-231216 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-231216.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-783481 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-296266 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-296266.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-731317 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731317.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-256092 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-344238 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-917115 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917115.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-816980 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
}
]
}
gsd-2021-25675
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2021-25675",
"description": "A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service.",
"id": "GSD-2021-25675"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-25675"
],
"details": "A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service.",
"id": "GSD-2021-25675",
"modified": "2023-12-13T01:23:21.418450Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-25675",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC S7-PLCSIM V5.4",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-369: Divide By Zero"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_s7-plcsim:5.4:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-25675"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-369"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 2.1,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "LOW",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6
}
},
"lastModifiedDate": "2021-03-18T17:16Z",
"publishedDate": "2021-03-15T17:15Z"
}
}
}
fkie_cve-2021-25675
Vulnerability from fkie_nvd
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | simatic_s7-plcsim | 5.4 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim:5.4:*:*:*:*:*:*:*",
"matchCriteriaId": "F5964421-8D14-4D38-B36A-EFC0E676BE65",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC S7-PLCSIM versi\u00f3n V5.4 (todas las versiones).\u0026#xa0;Un atacante con acceso local al sistema podr\u00eda causar una condici\u00f3n de Denegaci\u00f3n de Servicio en la aplicaci\u00f3n cuando es usada para abrir un archivo especialmente dise\u00f1ado.\u0026#xa0;Como consecuencia, podr\u00eda ocurrir una operaci\u00f3n de divisi\u00f3n por cero y causar a la aplicaci\u00f3n finalizar inesperadamente y deba reiniciarse para restaurar el servicio"
}
],
"id": "CVE-2021-25675",
"lastModified": "2024-11-21T05:55:16.547",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 2.1,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-03-15T17:15:22.003",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-369"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
cnvd-2021-16445
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf
| Name | Siemens SIMATIC S7-PLCSIM 5.4 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2021-25675"
}
},
"description": "SIMATIC S7-PLCSIM V5.4\u662f\u4e00\u4e2aWindows\u5e94\u7528\u7a0b\u5e8f\uff0c\u5b83\u6a21\u62df\u7528\u6237\u7a0b\u5e8f\u7684\u6267\u884c\uff0c\u7528\u4e8e\u6a21\u62df\u6a21\u62dfS7-300 CPU\u3001S7-400 CPU\u548cWinAC\u7cfb\u5217\u63a7\u5236\u5668\u3002\n\nSiemens SIMATIC S7-PLCSIM\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u5728\u5e94\u7528\u7a0b\u5e8f\u4e2d\u9020\u6210\u62d2\u7edd\u670d\u52a1\u60c5\u51b5\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-16445",
"openTime": "2021-03-11",
"patchDescription": "SIMATIC S7-PLCSIM V5.4\u662f\u4e00\u4e2aWindows\u5e94\u7528\u7a0b\u5e8f\uff0c\u5b83\u6a21\u62df\u7528\u6237\u7a0b\u5e8f\u7684\u6267\u884c\uff0c\u7528\u4e8e\u6a21\u62df\u6a21\u62dfS7-300 CPU\u3001S7-400 CPU\u548cWinAC\u7cfb\u5217\u63a7\u5236\u5668\u3002\r\n\r\nSiemens SIMATIC S7-PLCSIM\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u5728\u5e94\u7528\u7a0b\u5e8f\u4e2d\u9020\u6210\u62d2\u7edd\u670d\u52a1\u60c5\u51b5\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens SIMATIC S7-PLCSIM\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Siemens SIMATIC S7-PLCSIM 5.4"
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf",
"serverity": "\u4e2d",
"submitTime": "2021-03-09",
"title": "Siemens SIMATIC S7-PLCSIM\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e"
}
ghsa-mcvp-7wv4-cg3w
Vulnerability from github
A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service.
{
"affected": [],
"aliases": [
"CVE-2021-25675"
],
"database_specific": {
"cwe_ids": [
"CWE-369"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-03-15T17:15:00Z",
"severity": "MODERATE"
},
"details": "A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service.",
"id": "GHSA-mcvp-7wv4-cg3w",
"modified": "2022-05-24T17:44:34Z",
"published": "2022-05-24T17:44:34Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-25675"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
}
],
"schema_version": "1.4.0",
"severity": []
}
var-202103-0975
Vulnerability from variot
A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service. SIMATIC S7-PLCSIM Is vulnerable to division by zero.Service operation interruption (DoS) It may be in a state. SIMATIC S7-PLCSIM V5.4 is a Windows application program that simulates the execution of user programs and is used to simulate S7-300 CPU, S7-400 CPU and WinAC series controllers.
Siemens SIMATIC S7-PLCSIM has security vulnerabilities. Attackers can use vulnerabilities to cause a denial of service in the application
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202103-0975",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic s7-plcsim",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "5.4"
},
{
"model": "simatic s7-plcsim",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic s7-plcsim",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "5.4"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-16445"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004474"
},
{
"db": "NVD",
"id": "CVE-2021-25675"
}
]
},
"cve": "CVE-2021-25675",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 2.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2021-25675",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.8,
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 4.9,
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CNVD-2021-16445",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 1.8,
"id": "CVE-2021-25675",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 5.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2021-25675",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2021-25675",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2021-25675",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2021-16445",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202103-686",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-16445"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004474"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-686"
},
{
"db": "NVD",
"id": "CVE-2021-25675"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service. SIMATIC S7-PLCSIM Is vulnerable to division by zero.Service operation interruption (DoS) It may be in a state. SIMATIC S7-PLCSIM V5.4 is a Windows application program that simulates the execution of user programs and is used to simulate S7-300 CPU, S7-400 CPU and WinAC series controllers. \n\r\n\r\nSiemens SIMATIC S7-PLCSIM has security vulnerabilities. Attackers can use vulnerabilities to cause a denial of service in the application",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-25675"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004474"
},
{
"db": "CNVD",
"id": "CNVD-2021-16445"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-25675",
"trust": 3.8
},
{
"db": "SIEMENS",
"id": "SSA-256092",
"trust": 2.2
},
{
"db": "ICS CERT",
"id": "ICSA-21-068-01",
"trust": 1.4
},
{
"db": "JVN",
"id": "JVNVU93441670",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004474",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-16445",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2021.0847",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202103-686",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-16445"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004474"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-686"
},
{
"db": "NVD",
"id": "CVE-2021-25675"
}
]
},
"id": "VAR-202103-0975",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-16445"
}
],
"trust": 1.1
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-16445"
}
]
},
"last_update_date": "2024-11-23T20:32:20.403000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-256092",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
},
{
"title": "Siemens SIMATIC Fixes for digital error vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=144278"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004474"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-686"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-369",
"trust": 1.0
},
{
"problemtype": "Division by zero (CWE-369) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004474"
},
{
"db": "NVD",
"id": "CVE-2021-25675"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-25675"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu93441670/"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-068-01"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-01"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/siemens-simatic-s7-plcsim-three-vulnerabilities-34785"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.0847"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-16445"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004474"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-686"
},
{
"db": "NVD",
"id": "CVE-2021-25675"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-16445"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004474"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-686"
},
{
"db": "NVD",
"id": "CVE-2021-25675"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-11T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-16445"
},
{
"date": "2021-11-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-004474"
},
{
"date": "2021-03-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-686"
},
{
"date": "2021-03-15T17:15:22.003000",
"db": "NVD",
"id": "CVE-2021-25675"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-16445"
},
{
"date": "2024-09-12T08:03:00",
"db": "JVNDB",
"id": "JVNDB-2021-004474"
},
{
"date": "2021-03-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-686"
},
{
"date": "2024-11-21T05:55:16.547000",
"db": "NVD",
"id": "CVE-2021-25675"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-686"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SIMATIC\u00a0S7-PLCSIM\u00a0 Division by zero vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004474"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "digital error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-686"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.