CVE-2020-8282 (GCVE-0-2020-8282)
Vulnerability from cvelistv5 – Published: 2020-12-14 19:41 – Updated: 2024-08-04 09:56
VLAI
Summary
A security issue was found in EdgePower 24V/54V firmware v1.7.0 and earlier where, due to missing CSRF protections, an attacker would have been able to perform unauthorized remote code execution.
Severity
8.8 (High)
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF) (CWE-352)
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://community.ui.com/releases/Security-adviso… | x_refsource_MISC |
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:56:28.276Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-advisory-bulletin-016-016/40c1d33d-785e-44d5-8e6c-56a8addef1bc"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EdgePower",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "EdgePower firmware v1.7.0 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A security issue was found in EdgePower 24V/54V firmware v1.7.0 and earlier where, due to missing CSRF protections, an attacker would have been able to perform unauthorized remote code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "Cross-Site Request Forgery (CSRF) (CWE-352)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-14T19:41:42.000Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://community.ui.com/releases/Security-advisory-bulletin-016-016/40c1d33d-785e-44d5-8e6c-56a8addef1bc"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"ID": "CVE-2020-8282",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EdgePower",
"version": {
"version_data": [
{
"version_value": "EdgePower firmware v1.7.0 and earlier"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A security issue was found in EdgePower 24V/54V firmware v1.7.0 and earlier where, due to missing CSRF protections, an attacker would have been able to perform unauthorized remote code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery (CSRF) (CWE-352)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://community.ui.com/releases/Security-advisory-bulletin-016-016/40c1d33d-785e-44d5-8e6c-56a8addef1bc",
"refsource": "MISC",
"url": "https://community.ui.com/releases/Security-advisory-bulletin-016-016/40c1d33d-785e-44d5-8e6c-56a8addef1bc"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2020-8282",
"datePublished": "2020-12-14T19:41:42.000Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:56:28.276Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-8282",
"date": "2026-06-12",
"epss": "0.00382",
"percentile": "0.60097"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ui:edgemax_edgepower_24v_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.7.0\", \"matchCriteriaId\": \"1C171C13-EC33-4FA5-AF2B-142BFF8F3F6C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ui:edgemax_edgepower_24v:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D9EA54AE-7B23-4367-A1E0-74ADC44626DE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ui:edgemax_edgepower_54v_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.7.0\", \"matchCriteriaId\": \"D4F6403E-4C67-4F66-AC9E-13F24D6B0E67\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ui:edgemax_edgepower_54v:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D3E09C26-5649-4DE9-B428-FE23C5DD3344\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A security issue was found in EdgePower 24V/54V firmware v1.7.0 and earlier where, due to missing CSRF protections, an attacker would have been able to perform unauthorized remote code execution.\"}, {\"lang\": \"es\", \"value\": \"Se encontr\\u00f3 un problema de seguridad en EdgePower 24V/54V versiones de firmware v1.7.0 y anteriores donde, debido a una falta de protecciones de CSRF, un atacante habr\\u00eda sido capaz de llevar a cabo una ejecuci\\u00f3n de c\\u00f3digo remota no autorizada\"}]",
"id": "CVE-2020-8282",
"lastModified": "2024-11-21T05:38:38.983",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2020-12-14T20:15:13.780",
"references": "[{\"url\": \"https://community.ui.com/releases/Security-advisory-bulletin-016-016/40c1d33d-785e-44d5-8e6c-56a8addef1bc\", \"source\": \"support@hackerone.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://community.ui.com/releases/Security-advisory-bulletin-016-016/40c1d33d-785e-44d5-8e6c-56a8addef1bc\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "support@hackerone.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"support@hackerone.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-352\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-352\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-8282\",\"sourceIdentifier\":\"support@hackerone.com\",\"published\":\"2020-12-14T20:15:13.780\",\"lastModified\":\"2024-11-21T05:38:38.983\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A security issue was found in EdgePower 24V/54V firmware v1.7.0 and earlier where, due to missing CSRF protections, an attacker would have been able to perform unauthorized remote code execution.\"},{\"lang\":\"es\",\"value\":\"Se encontr\u00f3 un problema de seguridad en EdgePower 24V/54V versiones de firmware v1.7.0 y anteriores donde, debido a una falta de protecciones de CSRF, un atacante habr\u00eda sido capaz de llevar a cabo una ejecuci\u00f3n de c\u00f3digo remota no autorizada\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"support@hackerone.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ui:edgemax_edgepower_24v_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.7.0\",\"matchCriteriaId\":\"1C171C13-EC33-4FA5-AF2B-142BFF8F3F6C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ui:edgemax_edgepower_24v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D9EA54AE-7B23-4367-A1E0-74ADC44626DE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ui:edgemax_edgepower_54v_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.7.0\",\"matchCriteriaId\":\"D4F6403E-4C67-4F66-AC9E-13F24D6B0E67\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ui:edgemax_edgepower_54v:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D3E09C26-5649-4DE9-B428-FE23C5DD3344\"}]}]}],\"references\":[{\"url\":\"https://community.ui.com/releases/Security-advisory-bulletin-016-016/40c1d33d-785e-44d5-8e6c-56a8addef1bc\",\"source\":\"support@hackerone.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://community.ui.com/releases/Security-advisory-bulletin-016-016/40c1d33d-785e-44d5-8e6c-56a8addef1bc\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…