CVE-2020-7559 (GCVE-0-2020-7559)
Vulnerability from cvelistv5 – Published: 2020-11-19 21:04 – Updated: 2024-08-04 09:33- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) |
Affected:
PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.465Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) ",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) ",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-09T13:06:09",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7559",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) ",
"version": {
"version_data": [
{
"version_value": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) "
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7559",
"datePublished": "2020-11-19T21:04:25",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.465Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"18E8CCC1-A467-4FEF-964D-8481EAE892EC\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists in PLC Simulator on EcoStruxure\\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\\u00aa Control Expert software when receiving a specially crafted request over Modbus.\"}, {\"lang\": \"es\", \"value\": \"CWE-120: Se presenta una vulnerabilidad de Copia del B\\u00fafer sin Comprobar el Tama\\u00f1o de la Entrada (\\\"Classic Buffer Overflow\\\") en el Simulador de PLC en EcoStruxure\\u00aa Control Expert (ahora Unity Pro) (todas las versiones) que podr\\u00eda causar un bloqueo del simulador de PLC presente en el software EcoStruxure\\u00aa Control Expert cuando recibe una petici\\u00f3n especialmente dise\\u00f1ada mediante Modbus\"}]",
"id": "CVE-2020-7559",
"lastModified": "2024-11-21T05:37:22.677",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-11-19T22:15:14.800",
"references": "[{\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2020-315-07\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Patch\", \"Product\", \"Vendor Advisory\"]}, {\"url\": \"https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2020-315-07\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Product\", \"Vendor Advisory\"]}, {\"url\": \"https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-120\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-7559\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2020-11-19T22:15:14.800\",\"lastModified\":\"2024-11-21T05:37:22.677\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus.\"},{\"lang\":\"es\",\"value\":\"CWE-120: Se presenta una vulnerabilidad de Copia del B\u00fafer sin Comprobar el Tama\u00f1o de la Entrada (\\\"Classic Buffer Overflow\\\") en el Simulador de PLC en EcoStruxure\u00aa Control Expert (ahora Unity Pro) (todas las versiones) que podr\u00eda causar un bloqueo del simulador de PLC presente en el software EcoStruxure\u00aa Control Expert cuando recibe una petici\u00f3n especialmente dise\u00f1ada mediante Modbus\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18E8CCC1-A467-4FEF-964D-8481EAE892EC\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-315-07\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Product\",\"Vendor Advisory\"]},{\"url\":\"https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-315-07\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Product\",\"Vendor Advisory\"]},{\"url\":\"https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
}
}
CERTFR-2020-AVI-726
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Premium processors avec Ethernet COPRO intégré (TSXP574634, TSXP575634, TSXP576634) toutes versions | ||
| Schneider Electric | N/A | Modicon M221 toutes références et toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for EcoStruxure Control Expert toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebStation versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions | ||
| Schneider Electric | N/A | J Data Radios toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions antérieures (les ordinateurs Windows utilisant un UEFI ne sont pas impactés) | ||
| Schneider Electric | N/A | M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions | ||
| Schneider Electric | N/A | Quantum processors avec Ethernet COPRO intégré 140CPU65xxxxx toutes versions | ||
| Schneider Electric | N/A | M340 CPUs BMX P34x toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Server installer versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Trio Q toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebReports versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Premium communication modules (TSXETY4103, TSXETY5103) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Central installer versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | IGSS Definition (Def.exe) version 14.0.0.20247 et versions antérieures | ||
| Schneider Electric | N/A | Easergy T300 versions antérieures à 2.7 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Premium processors avec Ethernet COPRO int\u00e9gr\u00e9 (TSXP574634, TSXP575634, TSXP576634) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M221 toutes r\u00e9f\u00e9rences et toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for EcoStruxure Control Expert toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebStation versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "J Data Radios toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions ant\u00e9rieures (les ordinateurs Windows utilisant un UEFI ne sont pas impact\u00e9s)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum processors avec Ethernet COPRO int\u00e9gr\u00e9 140CPU65xxxxx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 CPUs BMX P34x toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Server installer versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Trio Q toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebReports versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Premium communication modules (TSXETY4103, TSXETY5103) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Central installer versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Definition (Def.exe) version 14.0.0.20247 et versions ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy T300 versions ant\u00e9rieures \u00e0 2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7564",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7564"
},
{
"name": "CVE-2020-7563",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7563"
},
{
"name": "CVE-2020-7558",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7558"
},
{
"name": "CVE-2020-7561",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7561"
},
{
"name": "CVE-2020-7555",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7555"
},
{
"name": "CVE-2020-7565",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7565"
},
{
"name": "CVE-2020-7570",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7570"
},
{
"name": "CVE-2020-7572",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7572"
},
{
"name": "CVE-2020-28213",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28213"
},
{
"name": "CVE-2020-7554",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7554"
},
{
"name": "CVE-2020-7557",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7557"
},
{
"name": "CVE-2020-7550",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7550"
},
{
"name": "CVE-2020-7553",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7553"
},
{
"name": "CVE-2020-7559",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7559"
},
{
"name": "CVE-2020-7566",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7566"
},
{
"name": "CVE-2020-7538",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7538"
},
{
"name": "CVE-2020-7556",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7556"
},
{
"name": "CVE-2020-28212",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28212"
},
{
"name": "CVE-2020-7562",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7562"
},
{
"name": "CVE-2020-7571",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7571"
},
{
"name": "CVE-2020-7552",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7552"
},
{
"name": "CVE-2020-28211",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28211"
},
{
"name": "CVE-2020-7551",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7551"
},
{
"name": "CVE-2020-7567",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7567"
},
{
"name": "CVE-2020-7544",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7544"
}
],
"links": [],
"reference": "CERTFR-2020-AVI-726",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-11-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-05 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-03 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-07 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-01/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-04 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-06 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-06/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-02 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SESB-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SESB-2020-315-01/"
}
]
}
CERTFR-2020-AVI-726
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Premium processors avec Ethernet COPRO intégré (TSXP574634, TSXP575634, TSXP576634) toutes versions | ||
| Schneider Electric | N/A | Modicon M221 toutes références et toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for EcoStruxure Control Expert toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebStation versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions | ||
| Schneider Electric | N/A | J Data Radios toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions antérieures (les ordinateurs Windows utilisant un UEFI ne sont pas impactés) | ||
| Schneider Electric | N/A | M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions | ||
| Schneider Electric | N/A | Quantum processors avec Ethernet COPRO intégré 140CPU65xxxxx toutes versions | ||
| Schneider Electric | N/A | M340 CPUs BMX P34x toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Server installer versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Trio Q toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebReports versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Premium communication modules (TSXETY4103, TSXETY5103) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Central installer versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | IGSS Definition (Def.exe) version 14.0.0.20247 et versions antérieures | ||
| Schneider Electric | N/A | Easergy T300 versions antérieures à 2.7 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Premium processors avec Ethernet COPRO int\u00e9gr\u00e9 (TSXP574634, TSXP575634, TSXP576634) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M221 toutes r\u00e9f\u00e9rences et toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for EcoStruxure Control Expert toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebStation versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "J Data Radios toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions ant\u00e9rieures (les ordinateurs Windows utilisant un UEFI ne sont pas impact\u00e9s)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum processors avec Ethernet COPRO int\u00e9gr\u00e9 140CPU65xxxxx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 CPUs BMX P34x toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Server installer versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Trio Q toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebReports versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Premium communication modules (TSXETY4103, TSXETY5103) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Central installer versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Definition (Def.exe) version 14.0.0.20247 et versions ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy T300 versions ant\u00e9rieures \u00e0 2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7564",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7564"
},
{
"name": "CVE-2020-7563",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7563"
},
{
"name": "CVE-2020-7558",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7558"
},
{
"name": "CVE-2020-7561",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7561"
},
{
"name": "CVE-2020-7555",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7555"
},
{
"name": "CVE-2020-7565",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7565"
},
{
"name": "CVE-2020-7570",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7570"
},
{
"name": "CVE-2020-7572",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7572"
},
{
"name": "CVE-2020-28213",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28213"
},
{
"name": "CVE-2020-7554",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7554"
},
{
"name": "CVE-2020-7557",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7557"
},
{
"name": "CVE-2020-7550",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7550"
},
{
"name": "CVE-2020-7553",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7553"
},
{
"name": "CVE-2020-7559",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7559"
},
{
"name": "CVE-2020-7566",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7566"
},
{
"name": "CVE-2020-7538",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7538"
},
{
"name": "CVE-2020-7556",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7556"
},
{
"name": "CVE-2020-28212",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28212"
},
{
"name": "CVE-2020-7562",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7562"
},
{
"name": "CVE-2020-7571",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7571"
},
{
"name": "CVE-2020-7552",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7552"
},
{
"name": "CVE-2020-28211",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28211"
},
{
"name": "CVE-2020-7551",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7551"
},
{
"name": "CVE-2020-7567",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7567"
},
{
"name": "CVE-2020-7544",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7544"
}
],
"links": [],
"reference": "CERTFR-2020-AVI-726",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-11-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-05 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-03 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-07 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-01/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-04 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-06 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-06/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-02 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SESB-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SESB-2020-315-01/"
}
]
}
VAR-202011-1295
Vulnerability from variot - Updated: 2022-05-04 09:15A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. PLC Simulator for EcoStruxure Control Expert and PLC Simulator for Unity Pro Is vulnerable to several vulnerabilities: ‥ * Buffer overflow (CWE-120) - CVE-2020-7559 ‥ * Improper checking in exceptional conditions of the program (CWE-754) - CVE-2020-7538 ‥ * Illegal authentication (CWE-863) - CVE-2020-28211 ‥ * Inappropriate restriction of excessive authentication attempts (CWE-307) - CVE-2020-28212 ‥ * Incomplete integrity verification of downloaded code (CWE-494) - CVE-2020-28213The expected impact depends on each vulnerability, but it may be affected as follows. ‥ * By a remote third party Modbus If you send a specially crafted request via EcoStruxure Control Expert of PLC Simulator Is crashed - CVE-2020-7559 , CVE-2020-7538 ‥ * Authentication is bypassed if the memory is overwritten by a local third party using the debugger - CVE-2020-28211 ‥ * By a remote third party Modbus Brute force attack via brute force executes unauthorized commands - CVE-2020-28212 ‥ * By a remote third party Modbus If a specially crafted request is sent via, an unauthorized command will be executed - CVE-2020-28213
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202011-1295",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ecostruxure control expert",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": "*"
},
{
"model": "plc simulator",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "for ecostruxure control expert \u5168\u3066"
},
{
"model": "plc simulator",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "for unity pro (\u65e7\u79f0\uff1aecostruxure control expert) \u5168\u3066"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "NVD",
"id": "CVE-2020-7559"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-7559"
}
]
},
"cve": "CVE-2020-7559",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2020-7559",
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2020-7559",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 10,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-009547",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2020-009547",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "IPA score",
"availabilityImpact": "None",
"baseScore": 7.4,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-009547",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 9.1,
"baseSeverity": "Critical",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2020-009547",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 8.1,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2020-009547",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "IPA",
"id": "JVNDB-2020-009547",
"trust": 2.4,
"value": "High"
},
{
"author": "IPA",
"id": "JVNDB-2020-009547",
"trust": 1.6,
"value": "Critical"
},
{
"author": "NVD",
"id": "CVE-2020-7559",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202011-1675",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1675"
},
{
"db": "NVD",
"id": "CVE-2020-7559"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus. PLC Simulator for EcoStruxure Control Expert and PLC Simulator for Unity Pro Is vulnerable to several vulnerabilities: \u2025 * Buffer overflow (CWE-120) - CVE-2020-7559 \u2025 * Improper checking in exceptional conditions of the program (CWE-754) - CVE-2020-7538 \u2025 * Illegal authentication (CWE-863) - CVE-2020-28211 \u2025 * Inappropriate restriction of excessive authentication attempts (CWE-307) - CVE-2020-28212 \u2025 * Incomplete integrity verification of downloaded code (CWE-494) - CVE-2020-28213The expected impact depends on each vulnerability, but it may be affected as follows. \u2025 * By a remote third party Modbus If you send a specially crafted request via EcoStruxure Control Expert of PLC Simulator Is crashed - CVE-2020-7559 , CVE-2020-7538 \u2025 * Authentication is bypassed if the memory is overwritten by a local third party using the debugger - CVE-2020-28211 \u2025 * By a remote third party Modbus Brute force attack via brute force executes unauthorized commands - CVE-2020-28212 \u2025 * By a remote third party Modbus If a specially crafted request is sent via, an unauthorized command will be executed - CVE-2020-28213",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-7559"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-7559",
"trust": 2.4
},
{
"db": "TALOS",
"id": "TALOS-2020-1140",
"trust": 1.6
},
{
"db": "SCHNEIDER",
"id": "SEVD-2020-315-07",
"trust": 1.6
},
{
"db": "ICS CERT",
"id": "ICSA-20-315-03",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU92857198",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1675",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1675"
},
{
"db": "NVD",
"id": "CVE-2020-7559"
}
]
},
"id": "VAR-202011-1295",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.7375
},
"last_update_date": "2022-05-04T09:15:37.678000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "EcoStruxure Control Expert",
"trust": 0.8,
"url": "https://www.se.com/ww/en/product-range-download/548-ecostruxure%e2%84%a2-control-expert/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control\u0026selected-node-id=12365959203#/software-firmware-tab"
},
{
"title": "Security Notification - PLC Simulator on EcoStruxure\u0026#8482; Control Expert",
"trust": 0.8,
"url": "https://www.se.com/ww/en/download/document/sevd-2020-315-07/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.8
},
{
"problemtype": "CWE-494",
"trust": 0.8
},
{
"problemtype": "CWE-307",
"trust": 0.8
},
{
"problemtype": "CWE-863",
"trust": 0.8
},
{
"problemtype": "CWE-754",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "NVD",
"id": "CVE-2020-7559"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://www.se.com/ww/en/download/document/sevd-2020-315-07"
},
{
"trust": 1.0,
"url": "https://www.talosintelligence.com/vulnerability_reports/talos-2020-1140"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7559"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7538"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-28211"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-28212"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-28213"
},
{
"trust": 0.8,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-315-03"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu92857198/"
},
{
"trust": 0.6,
"url": "https://talosintelligence.com/vulnerability_reports/talos-2020-1140"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-7559"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1675"
},
{
"db": "NVD",
"id": "CVE-2020-7559"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-1675"
},
{
"db": "NVD",
"id": "CVE-2020-7559"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-11-12T06:49:50",
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"date": "2020-11-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202011-1675"
},
{
"date": "2020-11-19T22:15:00",
"db": "NVD",
"id": "CVE-2020-7559"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-11-12T06:49:50",
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"date": "2022-03-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202011-1675"
},
{
"date": "2022-02-03T13:48:00",
"db": "NVD",
"id": "CVE-2020-7559"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202011-1675"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric Made PLC Simulator for EcoStruxure Control Expert Multiple vulnerabilities in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202011-1675"
}
],
"trust": 0.6
}
}
CVE-2020-7559
Vulnerability from csaf_se - Published: 2020-11-10 15:07 - Updated: 2023-03-14 15:07Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its PLC Simulator for EcoStruxure\u2122 Control Expert product.\r\nPLC Simulator feature is part of the EcostruxureTM Control Expert and EcostruxureTM Process Expert software and it helps users to review and test their configurations files in a simulation environment; it is not intended to be used as a controller CPU in a production environment.\r\nFailure to apply the mitigations provided below may risk unauthorized command execution or denial of service, which could result in undesired actions by the PLC simulator software.\r\nMarch 2023 Update: An additional mitigation has been provided using a Cybersecurity Application Note (page 3).",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "PLC Simulator on EcoStruxure\u2122 Control Expert and Process Expert - SEVD-2020-315-07 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2020-315-07_PLC_Simulator_on_EcoStruxure%E2%84%A2_Control_Expert_and_Process_Expert_Security_Notification.pdf"
},
{
"category": "self",
"summary": "PLC Simulator on EcoStruxure\u2122 Control Expert and Process Expert - SEVD-2020-315-07 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2020-315-07.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "PLC Simulator on EcoStruxure\u2122 Control Expert and Process Expert",
"tracking": {
"current_release_date": "2023-03-14T15:07:11.000Z",
"generator": {
"date": "2023-03-13T16:18:08.115Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2020-315-07",
"initial_release_date": "2020-11-10T15:07:11.000Z",
"revision_history": [
{
"date": "2020-11-10T15:07:11.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2021-03-09T15:07:11.000Z",
"number": "2.0.0",
"summary": "Future remediation plan will include a fix for CVE-2020-7559 (page 2)"
},
{
"date": "2021-06-08T15:07:11.000Z",
"number": "3.0.0",
"summary": "PLC Simulator for EcostruxureTM Process Expert has been added as an affected product. In addition, a new mitigation option has been added. (page 1-3)"
},
{
"date": "2021-07-13T15:07:11.000Z",
"number": "3.1.0",
"summary": "Added fix of CVE-2020-7559 for PLC Simulator for EcoStruxure\u2122 Control Expert"
},
{
"date": "2023-03-14T15:07:11.000Z",
"number": "4.0.0",
"summary": "An additional mitigation has been provided using a Cybersecurity Application Note (page 3)."
}
],
"status": "final",
"version": "4.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c15.0 SP1",
"product": {
"name": "Schneider Electric PLC Simulator for EcoStruxure\u2122 Control Expert prior to v15.0 SP1",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "PLC Simulator for EcoStruxure\u2122 Control Expert"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric PLC Simulator for Unity Pro (former name of EcoStruxure\u2122 Control Expert) all versions",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "PLC Simulator for Unity Pro (former name of EcoStruxure\u2122 Control Expert)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Schneider Electric PLC Simulator for EcoStruxure\u2122 Process Expert all versions",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "PLC Simulator for EcoStruxure\u2122 Process Expert"
},
{
"branches": [
{
"category": "product_version",
"name": "15.0 SP1",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Control Expert 15.0 SP1",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Control Expert"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Alexander Perez-Palma and Jared Rittle"
],
"organization": "Cisco Talos"
}
],
"cve": "CVE-2020-7559",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists that could cause a crash of the PLC simulator present in EcoStruxure\u2122 Control Expert software and EcoStruxure\u2122 Process Expert when receiving a specially crafted request over Modbus.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"4"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "EcoStruxure\u2122 Control Expert Version 15.0 SP1 product includes a fix for the vulnerability CVE-2020-7559 and is available for download here:\r\nhttps://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1\r\nCustomers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure.\r\nContact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch.\r\nIf customers choose not to apply the remediation provided above, they should immediately follow the recommendations in the Mitigation section below to reduce the risk of exploit.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit of the CVE-2020-7538, CVE-2020-28211, CVE-2020-28212, CVE-2020-28213\r\n\u2022 V15.0 of the EcoStruxure\u2122 Control Expert software includes a mitigation for these vulnerabilities, when applied with the steps outlined below, and is available for download here:\r\n\r\nhttps://www.se.com/ww/en/product-range-download/548-ecostruxure%E2%84%A2-control-expert/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control\u0026selected-node-id=12365959203#/software-firmware-tab\r\n\u2022 EcoStruxure\u2122 Process Expert 2020 R2 software, includes a mitigation, when applied with the steps outlined below, for these vulnerabilities and is available for download on the EcoStruxure Process Expert Support Portal (registration is needed):\r\nhttps://app.schneider-electric.com/ecostruxure-hybrid-dcs/\r\nAfter downloading the updated software listed above, the following steps are required to mitigate the vulnerability:\r\n1. Harden the Engineering Workstation running PLC Simulator\r\no Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices guide available for download here.\r\no To help protect workstations running Schneider Electric and other user applications against execution of unauthorized applications and malicious files, Schneider Electric recommends using McAfee Application and Change Control software. Refer to the Cybsercurity Application Note available here.\r\n2. On V15.0 of the EcoStruxure\u2122 Control Expert and EcoStruxure\u2122 Process Expert 2020 R2 software, in the option dialog box of the PLC simulator, customers are requested to set the Listening IP Address to:\r\na. 127.0.0.1 (localhost), which will prevent remote network connections to the PLC simulator; or\r\nb. When deployed as a remote access system the IP Address should be configured to be the same as the system that will be running the PLC simulator.\r\nNote: Customers are informed that on EcoStruxure\u2122 Control Expert v15.0 and EcoStruxure\u2122 Process Expert 2020 R2 software and prior, the default listening IP address is: 0.0.0.0. The default setting exposes the PLC simulator to the vulnerabilities described in this bulletin. The default listening IP address is configurable from v15.0 and 2020 R2 and above.\r\nUpdate: Starting with EcoStruxure\u2122 Control Expert v15.0 SP1 and above the default listening IP address is: 127.0.0.1. The same setting is also recommended for the PLC Simulator and is documented in the PLC Simulator user manual available here\r\n\r\nCustomers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch\r\n\r\nIf customers choose not to apply the mitigations provided above or in case of older versions of EcoStruxure\u2122 Control Expert software, they should immediately apply the following mitigations to reduce the risk of exploit:\r\n1. Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n2. Harden the Engineering Workstation running PLC Simulator for EcoStruxure\u2122 Control Expert and EcoStruxure\u2122 Process Expert\r\no Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices guide available for download here.\r\nTo ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1"
]
}
],
"title": "CVE-2020-7559"
},
{
"acknowledgments": [
{
"names": [
"Alexander Perez-Palma and Jared Rittle"
],
"organization": "Cisco Talos"
}
],
"cve": "CVE-2020-28212",
"cwe": {
"id": "CWE-307",
"name": "Improper Restriction of Excessive Authentication Attempts"
},
"notes": [
{
"category": "description",
"text": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause unauthorized command execution when a brute force attack is done over Modbus.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "EcoStruxure\u2122 Control Expert Version 15.0 SP1 product includes a fix for the vulnerability CVE-2020-7559 and is available for download here:\r\nhttps://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1\r\nCustomers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure.\r\nContact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch.\r\nIf customers choose not to apply the remediation provided above, they should immediately follow the recommendations in the Mitigation section below to reduce the risk of exploit.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit of the CVE-2020-7538, CVE-2020-28211, CVE-2020-28212, CVE-2020-28213\r\n\u2022 V15.0 of the EcoStruxure\u2122 Control Expert software includes a mitigation for these vulnerabilities, when applied with the steps outlined below, and is available for download here:\r\n\r\nhttps://www.se.com/ww/en/product-range-download/548-ecostruxure%E2%84%A2-control-expert/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control\u0026selected-node-id=12365959203#/software-firmware-tab\r\n\u2022 EcoStruxure\u2122 Process Expert 2020 R2 software, includes a mitigation, when applied with the steps outlined below, for these vulnerabilities and is available for download on the EcoStruxure Process Expert Support Portal (registration is needed):\r\nhttps://app.schneider-electric.com/ecostruxure-hybrid-dcs/\r\nAfter downloading the updated software listed above, the following steps are required to mitigate the vulnerability:\r\n1. Harden the Engineering Workstation running PLC Simulator\r\no Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices guide available for download here.\r\no To help protect workstations running Schneider Electric and other user applications against execution of unauthorized applications and malicious files, Schneider Electric recommends using McAfee Application and Change Control software. Refer to the Cybsercurity Application Note available here.\r\n2. On V15.0 of the EcoStruxure\u2122 Control Expert and EcoStruxure\u2122 Process Expert 2020 R2 software, in the option dialog box of the PLC simulator, customers are requested to set the Listening IP Address to:\r\na. 127.0.0.1 (localhost), which will prevent remote network connections to the PLC simulator; or\r\nb. When deployed as a remote access system the IP Address should be configured to be the same as the system that will be running the PLC simulator.\r\nNote: Customers are informed that on EcoStruxure\u2122 Control Expert v15.0 and EcoStruxure\u2122 Process Expert 2020 R2 software and prior, the default listening IP address is: 0.0.0.0. The default setting exposes the PLC simulator to the vulnerabilities described in this bulletin. The default listening IP address is configurable from v15.0 and 2020 R2 and above.\r\nUpdate: Starting with EcoStruxure\u2122 Control Expert v15.0 SP1 and above the default listening IP address is: 127.0.0.1. The same setting is also recommended for the PLC Simulator and is documented in the PLC Simulator user manual available here\r\n\r\nCustomers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch\r\n\r\nIf customers choose not to apply the mitigations provided above or in case of older versions of EcoStruxure\u2122 Control Expert software, they should immediately apply the following mitigations to reduce the risk of exploit:\r\n1. Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n2. Harden the Engineering Workstation running PLC Simulator for EcoStruxure\u2122 Control Expert and EcoStruxure\u2122 Process Expert\r\no Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices guide available for download here.\r\nTo ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2020-28212"
},
{
"acknowledgments": [
{
"names": [
"Alexander Perez-Palma and Jared Rittle"
],
"organization": "Cisco Talos"
}
],
"cve": "CVE-2020-28213",
"cwe": {
"id": "CWE-494",
"name": "Download of Code Without Integrity Check"
},
"notes": [
{
"category": "description",
"text": "A CWE-494: Download of Code Without Integrity Check vulnerability exists that could cause unauthorized command execution when sending specially crafted requests over Modbus.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "EcoStruxure\u2122 Control Expert Version 15.0 SP1 product includes a fix for the vulnerability CVE-2020-7559 and is available for download here:\r\nhttps://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1\r\nCustomers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure.\r\nContact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch.\r\nIf customers choose not to apply the remediation provided above, they should immediately follow the recommendations in the Mitigation section below to reduce the risk of exploit.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit of the CVE-2020-7538, CVE-2020-28211, CVE-2020-28212, CVE-2020-28213\r\n\u2022 V15.0 of the EcoStruxure\u2122 Control Expert software includes a mitigation for these vulnerabilities, when applied with the steps outlined below, and is available for download here:\r\n\r\nhttps://www.se.com/ww/en/product-range-download/548-ecostruxure%E2%84%A2-control-expert/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control\u0026selected-node-id=12365959203#/software-firmware-tab\r\n\u2022 EcoStruxure\u2122 Process Expert 2020 R2 software, includes a mitigation, when applied with the steps outlined below, for these vulnerabilities and is available for download on the EcoStruxure Process Expert Support Portal (registration is needed):\r\nhttps://app.schneider-electric.com/ecostruxure-hybrid-dcs/\r\nAfter downloading the updated software listed above, the following steps are required to mitigate the vulnerability:\r\n1. Harden the Engineering Workstation running PLC Simulator\r\no Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices guide available for download here.\r\no To help protect workstations running Schneider Electric and other user applications against execution of unauthorized applications and malicious files, Schneider Electric recommends using McAfee Application and Change Control software. Refer to the Cybsercurity Application Note available here.\r\n2. On V15.0 of the EcoStruxure\u2122 Control Expert and EcoStruxure\u2122 Process Expert 2020 R2 software, in the option dialog box of the PLC simulator, customers are requested to set the Listening IP Address to:\r\na. 127.0.0.1 (localhost), which will prevent remote network connections to the PLC simulator; or\r\nb. When deployed as a remote access system the IP Address should be configured to be the same as the system that will be running the PLC simulator.\r\nNote: Customers are informed that on EcoStruxure\u2122 Control Expert v15.0 and EcoStruxure\u2122 Process Expert 2020 R2 software and prior, the default listening IP address is: 0.0.0.0. The default setting exposes the PLC simulator to the vulnerabilities described in this bulletin. The default listening IP address is configurable from v15.0 and 2020 R2 and above.\r\nUpdate: Starting with EcoStruxure\u2122 Control Expert v15.0 SP1 and above the default listening IP address is: 127.0.0.1. The same setting is also recommended for the PLC Simulator and is documented in the PLC Simulator user manual available here\r\n\r\nCustomers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch\r\n\r\nIf customers choose not to apply the mitigations provided above or in case of older versions of EcoStruxure\u2122 Control Expert software, they should immediately apply the following mitigations to reduce the risk of exploit:\r\n1. Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n2. Harden the Engineering Workstation running PLC Simulator for EcoStruxure\u2122 Control Expert and EcoStruxure\u2122 Process Expert\r\no Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices guide available for download here.\r\nTo ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2020-28213"
},
{
"acknowledgments": [
{
"names": [
"Alexander Perez-Palma and Jared Rittle"
],
"organization": "Cisco Talos"
}
],
"cve": "CVE-2020-7538",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"category": "description",
"text": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a crash of the PLC simulator present in EcoStruxure\u2122 Control Expert software and EcoStruxure\u2122 Process Expert when receiving a specially crafted request over Modbus.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "EcoStruxure\u2122 Control Expert Version 15.0 SP1 product includes a fix for the vulnerability CVE-2020-7559 and is available for download here:\r\nhttps://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1\r\nCustomers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure.\r\nContact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch.\r\nIf customers choose not to apply the remediation provided above, they should immediately follow the recommendations in the Mitigation section below to reduce the risk of exploit.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit of the CVE-2020-7538, CVE-2020-28211, CVE-2020-28212, CVE-2020-28213\r\n\u2022 V15.0 of the EcoStruxure\u2122 Control Expert software includes a mitigation for these vulnerabilities, when applied with the steps outlined below, and is available for download here:\r\n\r\nhttps://www.se.com/ww/en/product-range-download/548-ecostruxure%E2%84%A2-control-expert/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control\u0026selected-node-id=12365959203#/software-firmware-tab\r\n\u2022 EcoStruxure\u2122 Process Expert 2020 R2 software, includes a mitigation, when applied with the steps outlined below, for these vulnerabilities and is available for download on the EcoStruxure Process Expert Support Portal (registration is needed):\r\nhttps://app.schneider-electric.com/ecostruxure-hybrid-dcs/\r\nAfter downloading the updated software listed above, the following steps are required to mitigate the vulnerability:\r\n1. Harden the Engineering Workstation running PLC Simulator\r\no Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices guide available for download here.\r\no To help protect workstations running Schneider Electric and other user applications against execution of unauthorized applications and malicious files, Schneider Electric recommends using McAfee Application and Change Control software. Refer to the Cybsercurity Application Note available here.\r\n2. On V15.0 of the EcoStruxure\u2122 Control Expert and EcoStruxure\u2122 Process Expert 2020 R2 software, in the option dialog box of the PLC simulator, customers are requested to set the Listening IP Address to:\r\na. 127.0.0.1 (localhost), which will prevent remote network connections to the PLC simulator; or\r\nb. When deployed as a remote access system the IP Address should be configured to be the same as the system that will be running the PLC simulator.\r\nNote: Customers are informed that on EcoStruxure\u2122 Control Expert v15.0 and EcoStruxure\u2122 Process Expert 2020 R2 software and prior, the default listening IP address is: 0.0.0.0. The default setting exposes the PLC simulator to the vulnerabilities described in this bulletin. The default listening IP address is configurable from v15.0 and 2020 R2 and above.\r\nUpdate: Starting with EcoStruxure\u2122 Control Expert v15.0 SP1 and above the default listening IP address is: 127.0.0.1. The same setting is also recommended for the PLC Simulator and is documented in the PLC Simulator user manual available here\r\n\r\nCustomers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch\r\n\r\nIf customers choose not to apply the mitigations provided above or in case of older versions of EcoStruxure\u2122 Control Expert software, they should immediately apply the following mitigations to reduce the risk of exploit:\r\n1. Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n2. Harden the Engineering Workstation running PLC Simulator for EcoStruxure\u2122 Control Expert and EcoStruxure\u2122 Process Expert\r\no Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices guide available for download here.\r\nTo ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2020-7538"
},
{
"acknowledgments": [
{
"names": [
"Alexander Perez-Palma and Jared Rittle"
],
"organization": "Cisco Talos"
}
],
"cve": "CVE-2020-28211",
"cwe": {
"id": "CWE-863",
"name": "Incorrect Authorization"
},
"notes": [
{
"category": "description",
"text": "A CWE-863: Incorrect Authorization vulnerability exists that could cause bypass of authentication when overwriting memory using a debugger.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "EcoStruxure\u2122 Control Expert Version 15.0 SP1 product includes a fix for the vulnerability CVE-2020-7559 and is available for download here:\r\nhttps://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1\r\nCustomers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure.\r\nContact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch.\r\nIf customers choose not to apply the remediation provided above, they should immediately follow the recommendations in the Mitigation section below to reduce the risk of exploit.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1"
},
{
"category": "mitigation",
"details": "Customers should immediately apply the following mitigations to reduce the risk of exploit of the CVE-2020-7538, CVE-2020-28211, CVE-2020-28212, CVE-2020-28213\r\n\u2022 V15.0 of the EcoStruxure\u2122 Control Expert software includes a mitigation for these vulnerabilities, when applied with the steps outlined below, and is available for download here:\r\n\r\nhttps://www.se.com/ww/en/product-range-download/548-ecostruxure%E2%84%A2-control-expert/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control\u0026selected-node-id=12365959203#/software-firmware-tab\r\n\u2022 EcoStruxure\u2122 Process Expert 2020 R2 software, includes a mitigation, when applied with the steps outlined below, for these vulnerabilities and is available for download on the EcoStruxure Process Expert Support Portal (registration is needed):\r\nhttps://app.schneider-electric.com/ecostruxure-hybrid-dcs/\r\nAfter downloading the updated software listed above, the following steps are required to mitigate the vulnerability:\r\n1. Harden the Engineering Workstation running PLC Simulator\r\no Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices guide available for download here.\r\no To help protect workstations running Schneider Electric and other user applications against execution of unauthorized applications and malicious files, Schneider Electric recommends using McAfee Application and Change Control software. Refer to the Cybsercurity Application Note available here.\r\n2. On V15.0 of the EcoStruxure\u2122 Control Expert and EcoStruxure\u2122 Process Expert 2020 R2 software, in the option dialog box of the PLC simulator, customers are requested to set the Listening IP Address to:\r\na. 127.0.0.1 (localhost), which will prevent remote network connections to the PLC simulator; or\r\nb. When deployed as a remote access system the IP Address should be configured to be the same as the system that will be running the PLC simulator.\r\nNote: Customers are informed that on EcoStruxure\u2122 Control Expert v15.0 and EcoStruxure\u2122 Process Expert 2020 R2 software and prior, the default listening IP address is: 0.0.0.0. The default setting exposes the PLC simulator to the vulnerabilities described in this bulletin. The default listening IP address is configurable from v15.0 and 2020 R2 and above.\r\nUpdate: Starting with EcoStruxure\u2122 Control Expert v15.0 SP1 and above the default listening IP address is: 127.0.0.1. The same setting is also recommended for the PLC Simulator and is documented in the PLC Simulator user manual available here\r\n\r\nCustomers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch\r\n\r\nIf customers choose not to apply the mitigations provided above or in case of older versions of EcoStruxure\u2122 Control Expert software, they should immediately apply the following mitigations to reduce the risk of exploit:\r\n1. Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP\r\n2. Harden the Engineering Workstation running PLC Simulator for EcoStruxure\u2122 Control Expert and EcoStruxure\u2122 Process Expert\r\no Follow workstation, network and site-hardening guidelines in the Recommended Cybersecurity Best Practices guide available for download here.\r\nTo ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric\u2019s security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp",
"product_ids": [
"1",
"2",
"3"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:N",
"version": "3.0"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2020-28211"
}
]
}
GSD-2020-7559
Vulnerability from gsd - Updated: 2023-12-13 01:21{
"GSD": {
"alias": "CVE-2020-7559",
"description": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus.",
"id": "GSD-2020-7559"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-7559"
],
"details": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus.",
"id": "GSD-2020-7559",
"modified": "2023-12-13T01:21:52.321282Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7559",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) ",
"version": {
"version_data": [
{
"version_value": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) "
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7559"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07",
"refsource": "MISC",
"tags": [
"Patch",
"Product",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140",
"refsource": "MISC",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2022-02-03T13:48Z",
"publishedDate": "2020-11-19T22:15Z"
}
}
}
GHSA-28RP-9F44-H4V6
Vulnerability from github – Published: 2022-05-24 22:28 – Updated: 2022-05-24 22:28A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.
{
"affected": [],
"aliases": [
"CVE-2020-7559"
],
"database_specific": {
"cwe_ids": [
"CWE-120"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-11-19T22:15:00Z",
"severity": "HIGH"
},
"details": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus.",
"id": "GHSA-28rp-9f44-h4v6",
"modified": "2022-05-24T22:28:03Z",
"published": "2022-05-24T22:28:03Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-7559"
},
{
"type": "WEB",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07"
},
{
"type": "WEB",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140"
}
],
"schema_version": "1.4.0",
"severity": []
}
FKIE_CVE-2020-7559
Vulnerability from fkie_nvd - Published: 2020-11-19 22:15 - Updated: 2024-11-21 05:37| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2020-315-07 | Patch, Product, Vendor Advisory | |
| cybersecurity@se.com | https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2020-315-07 | Patch, Product, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140 | Exploit, Third Party Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | ecostruxure_control_expert | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"matchCriteriaId": "18E8CCC1-A467-4FEF-964D-8481EAE892EC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus."
},
{
"lang": "es",
"value": "CWE-120: Se presenta una vulnerabilidad de Copia del B\u00fafer sin Comprobar el Tama\u00f1o de la Entrada (\"Classic Buffer Overflow\") en el Simulador de PLC en EcoStruxure\u00aa Control Expert (ahora Unity Pro) (todas las versiones) que podr\u00eda causar un bloqueo del simulador de PLC presente en el software EcoStruxure\u00aa Control Expert cuando recibe una petici\u00f3n especialmente dise\u00f1ada mediante Modbus"
}
],
"id": "CVE-2020-7559",
"lastModified": "2024-11-21T05:37:22.677",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-19T22:15:14.800",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Product",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Product",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2020-1140"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.