CVE-2020-7538 (GCVE-0-2020-7538)
Vulnerability from cvelistv5
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) |
Version: PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.804Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) ",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-19T21:04:18",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7538",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) ",
"version": {
"version_data": [
{
"version_value": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7538",
"datePublished": "2020-11-19T21:04:18",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.804Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2020-7538\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2020-11-19T22:15:14.020\",\"lastModified\":\"2024-11-21T05:37:20.313\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus.\"},{\"lang\":\"es\",\"value\":\"CWE-754: Se presenta una vulnerabilidad Comprobaci\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales en el Simulador de PLC en EcoStruxure\u00aa Control Expert (ahora Unity Pro) (todas las versiones) que podr\u00eda causar un bloqueo del simulador de PLC presente en el software EcoStruxure\u00aa Control Expert cuando recibe una petici\u00f3n especialmente dise\u00f1ada mediante Modbus\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18E8CCC1-A467-4FEF-964D-8481EAE892EC\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-315-07/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-315-07/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
CERTFR-2020-AVI-726
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Premium processors avec Ethernet COPRO intégré (TSXP574634, TSXP575634, TSXP576634) toutes versions | ||
| Schneider Electric | N/A | Modicon M221 toutes références et toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for EcoStruxure Control Expert toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebStation versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions | ||
| Schneider Electric | N/A | J Data Radios toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions antérieures (les ordinateurs Windows utilisant un UEFI ne sont pas impactés) | ||
| Schneider Electric | N/A | M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions | ||
| Schneider Electric | N/A | Quantum processors avec Ethernet COPRO intégré 140CPU65xxxxx toutes versions | ||
| Schneider Electric | N/A | M340 CPUs BMX P34x toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Server installer versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Trio Q toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebReports versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Premium communication modules (TSXETY4103, TSXETY5103) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Central installer versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | IGSS Definition (Def.exe) version 14.0.0.20247 et versions antérieures | ||
| Schneider Electric | N/A | Easergy T300 versions antérieures à 2.7 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Premium processors avec Ethernet COPRO int\u00e9gr\u00e9 (TSXP574634, TSXP575634, TSXP576634) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M221 toutes r\u00e9f\u00e9rences et toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for EcoStruxure Control Expert toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebStation versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "J Data Radios toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions ant\u00e9rieures (les ordinateurs Windows utilisant un UEFI ne sont pas impact\u00e9s)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum processors avec Ethernet COPRO int\u00e9gr\u00e9 140CPU65xxxxx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 CPUs BMX P34x toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Server installer versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Trio Q toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebReports versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Premium communication modules (TSXETY4103, TSXETY5103) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Central installer versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Definition (Def.exe) version 14.0.0.20247 et versions ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy T300 versions ant\u00e9rieures \u00e0 2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7564",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7564"
},
{
"name": "CVE-2020-7563",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7563"
},
{
"name": "CVE-2020-7558",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7558"
},
{
"name": "CVE-2020-7561",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7561"
},
{
"name": "CVE-2020-7555",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7555"
},
{
"name": "CVE-2020-7565",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7565"
},
{
"name": "CVE-2020-7570",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7570"
},
{
"name": "CVE-2020-7572",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7572"
},
{
"name": "CVE-2020-28213",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28213"
},
{
"name": "CVE-2020-7554",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7554"
},
{
"name": "CVE-2020-7557",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7557"
},
{
"name": "CVE-2020-7550",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7550"
},
{
"name": "CVE-2020-7553",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7553"
},
{
"name": "CVE-2020-7559",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7559"
},
{
"name": "CVE-2020-7566",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7566"
},
{
"name": "CVE-2020-7538",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7538"
},
{
"name": "CVE-2020-7556",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7556"
},
{
"name": "CVE-2020-28212",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28212"
},
{
"name": "CVE-2020-7562",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7562"
},
{
"name": "CVE-2020-7571",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7571"
},
{
"name": "CVE-2020-7552",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7552"
},
{
"name": "CVE-2020-28211",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28211"
},
{
"name": "CVE-2020-7551",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7551"
},
{
"name": "CVE-2020-7567",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7567"
},
{
"name": "CVE-2020-7544",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7544"
}
],
"initial_release_date": "2020-11-12T00:00:00",
"last_revision_date": "2020-11-12T00:00:00",
"links": [],
"reference": "CERTFR-2020-AVI-726",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-11-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-05 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-03 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-07 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-01/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-04 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-06 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-06/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-02 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SESB-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SESB-2020-315-01/"
}
]
}
var-202011-1297
Vulnerability from variot
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. ‥ * By a remote third party Modbus If you send a specially crafted request via EcoStruxure Control Expert of PLC Simulator Is crashed - CVE-2020-7559 , CVE-2020-7538 ‥ * Authentication is bypassed if the memory is overwritten by a local third party using the debugger - CVE-2020-28211 ‥ * By a remote third party Modbus Brute force attack via brute force executes unauthorized commands - CVE-2020-28212 ‥ * By a remote third party Modbus If a specially crafted request is sent via, an unauthorized command will be executed - CVE-2020-28213. Schneider Electric EcoStruxure Control Expert (formerly known as Unity Pro) is a set of programming software for Schneider Electric logic controller products from French Schneider Electric (Schneider Electric). No detailed vulnerability details are currently provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202011-1297",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ecostruxure control expert",
"scope": "eq",
"trust": 1.0,
"vendor": "schneider electric",
"version": "*"
},
{
"model": "plc simulator",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "for ecostruxure control expert \u5168\u3066"
},
{
"model": "plc simulator",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": "for unity pro (\u65e7\u79f0\uff1aecostruxure control expert) \u5168\u3066"
},
{
"model": "electric ecostruxure control expert",
"scope": null,
"trust": 0.6,
"vendor": "schneider",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31183"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "NVD",
"id": "CVE-2020-7538"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:schneider_electric:plc_simulator",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
}
]
},
"cve": "CVE-2020-7538",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2020-7538",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-31183",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2020-7538",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 10,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-009547",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2020-009547",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "IPA score",
"availabilityImpact": "None",
"baseScore": 7.4,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-009547",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 9.1,
"baseSeverity": "Critical",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2020-009547",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "IPA score",
"availabilityImpact": "High",
"baseScore": 8.1,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2020-009547",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "IPA",
"id": "JVNDB-2020-009547",
"trust": 2.4,
"value": "High"
},
{
"author": "IPA",
"id": "JVNDB-2020-009547",
"trust": 1.6,
"value": "Critical"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2020-7538",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2021-31183",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202011-842",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31183"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-842"
},
{
"db": "NVD",
"id": "CVE-2020-7538"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus. \u2025 * By a remote third party Modbus If you send a specially crafted request via EcoStruxure Control Expert of PLC Simulator Is crashed - CVE-2020-7559 , CVE-2020-7538 \u2025 * Authentication is bypassed if the memory is overwritten by a local third party using the debugger - CVE-2020-28211 \u2025 * By a remote third party Modbus Brute force attack via brute force executes unauthorized commands - CVE-2020-28212 \u2025 * By a remote third party Modbus If a specially crafted request is sent via, an unauthorized command will be executed - CVE-2020-28213. Schneider Electric EcoStruxure Control Expert (formerly known as Unity Pro) is a set of programming software for Schneider Electric logic controller products from French Schneider Electric (Schneider Electric). No detailed vulnerability details are currently provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-7538"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "CNVD",
"id": "CNVD-2021-31183"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-7538",
"trust": 3.0
},
{
"db": "ICS CERT",
"id": "ICSA-20-315-03",
"trust": 2.0
},
{
"db": "SCHNEIDER",
"id": "SEVD-2020-315-07",
"trust": 1.6
},
{
"db": "JVN",
"id": "JVNVU92857198",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-31183",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2020.4042",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202011-842",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31183"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-842"
},
{
"db": "NVD",
"id": "CVE-2020-7538"
}
]
},
"id": "VAR-202011-1297",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31183"
}
],
"trust": 1.2287037
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31183"
}
]
},
"last_update_date": "2024-11-23T22:25:15.520000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "EcoStruxure Control Expert",
"trust": 0.8,
"url": "https://www.se.com/ww/en/product-range-download/548-ecostruxure%E2%84%A2-control-expert/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control\u0026selected-node-id=12365959203#/software-firmware-tab"
},
{
"title": "Security Notification - PLC Simulator on EcoStruxure\u0026#8482; Control Expert",
"trust": 0.8,
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
},
{
"title": "Patch for Schneider Electric EcoStruxure Control Expert PLC Denial of Service Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/261466"
},
{
"title": "Schneider Electric EcoStruxure Control Expert Fixes for code issue vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=137113"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31183"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-842"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-754",
"trust": 1.8
},
{
"problemtype": "CWE-494",
"trust": 0.8
},
{
"problemtype": "CWE-307",
"trust": 0.8
},
{
"problemtype": "CWE-120",
"trust": 0.8
},
{
"problemtype": "CWE-863",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "NVD",
"id": "CVE-2020-7538"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-315-03"
},
{
"trust": 1.6,
"url": "https://www.se.com/ww/en/download/document/sevd-2020-315-07/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7559"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7538"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-28211"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-28212"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-28213"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu92857198/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-7538"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.4042/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-31183"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-842"
},
{
"db": "NVD",
"id": "CVE-2020-7538"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-31183"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"db": "CNNVD",
"id": "CNNVD-202011-842"
},
{
"db": "NVD",
"id": "CVE-2020-7538"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-31183"
},
{
"date": "2020-11-12T06:49:50",
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"date": "2020-11-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202011-842"
},
{
"date": "2020-11-19T22:15:14.020000",
"db": "NVD",
"id": "CVE-2020-7538"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-31183"
},
{
"date": "2020-11-12T06:49:50",
"db": "JVNDB",
"id": "JVNDB-2020-009547"
},
{
"date": "2022-03-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202011-842"
},
{
"date": "2024-11-21T05:37:20.313000",
"db": "NVD",
"id": "CVE-2020-7538"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202011-842"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric Made PLC Simulator for EcoStruxure Control Expert Multiple vulnerabilities in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009547"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "code problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202011-842"
}
],
"trust": 0.6
}
}
icsa-20-315-03
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Parity Dynamics Research Team",
"summary": "reporting this vulnerability to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could cause a denial-of-service condition, which could result in a failure of the EcoStruxture Control Expert Simulator.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Energy, Food and Agriculture, Government Facilities, Transportation Systems, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-315-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-315-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-315-03 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-315-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric PLC Simulator for EcoStruxure Control Expert",
"tracking": {
"current_release_date": "2020-11-10T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-315-03",
"initial_release_date": "2020-11-10T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-11-10T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-315-03 Schneider Electric PLC Simulator for EcoStruxure Control Expert"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "vers:all/*",
"product": {
"name": "PLC Simulator for Unity Pro (former name of EcoStruxure Control Expert): all versions",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "PLC Simulator for Unity Pro (former name of EcoStruxure Control Expert)"
},
{
"branches": [
{
"category": "product_version",
"name": "vers:all/*",
"product": {
"name": "PLC Simulator for EcoStruxure Control Expert: all versions",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "PLC Simulator for EcoStruxure Control Expert"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-7538",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability exists that could cause a crash of the PLC simulator present in EcoStruxure Control Expert software when receiving a specially crafted request over Modbus.CVE-2020-7538 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7538"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has released Version 15.0 of the EcoStruxure Control Expert software to mitigate this vulnerability. It is available for download on the Schneider Electric website.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/product-range-download/548-ecostruxure%E2%84%A2-control-expert/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control\u0026selected-node-id=12365959203#/software-firmware-tab"
},
{
"category": "mitigation",
"details": "In the option dialog box of the PLC simulator, set the listening IP Address to 127.0.0.1 (localhost), which will prevent remote network connections to the PLC simulator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "The default listening IP address is: 0.0.0.0. The default setting exposes the PLC to the vulnerability described in this advisory.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Schneider Electric recommends using appropriate patching methodologies when applying these patches. It also strongly recommends the use of back-ups and evaluating the impact of these patches in a test and development environment or on offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/work/support/country-selector/contact-us.jsp"
},
{
"category": "mitigation",
"details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Set up network segmentation and implement a firewall to block all unauthorized access to Port 502/TCP",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Harden the engineering workstation running PLC Simulator for EcoStruxure Control Expert",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Follow workstation, network, and site-hardening guidelines in the Cybersecurity Best Practices guide.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/download/document/CS-Best-Practices-2019-340/"
},
{
"category": "mitigation",
"details": "Please see Schneider Electric Security Notification number SEVD-2020-315-07 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2020-315-07"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
ICSA-20-315-03
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Parity Dynamics Research Team",
"summary": "reporting this vulnerability to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability could cause a denial-of-service condition, which could result in a failure of the EcoStruxture Control Expert Simulator.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Energy, Food and Agriculture, Government Facilities, Transportation Systems, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-315-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-315-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-315-03 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-315-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric PLC Simulator for EcoStruxure Control Expert",
"tracking": {
"current_release_date": "2020-11-10T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-315-03",
"initial_release_date": "2020-11-10T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-11-10T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-315-03 Schneider Electric PLC Simulator for EcoStruxure Control Expert"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "vers:all/*",
"product": {
"name": "PLC Simulator for Unity Pro (former name of EcoStruxure Control Expert): all versions",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "PLC Simulator for Unity Pro (former name of EcoStruxure Control Expert)"
},
{
"branches": [
{
"category": "product_version",
"name": "vers:all/*",
"product": {
"name": "PLC Simulator for EcoStruxure Control Expert: all versions",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "PLC Simulator for EcoStruxure Control Expert"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-7538",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability exists that could cause a crash of the PLC simulator present in EcoStruxure Control Expert software when receiving a specially crafted request over Modbus.CVE-2020-7538 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7538"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has released Version 15.0 of the EcoStruxure Control Expert software to mitigate this vulnerability. It is available for download on the Schneider Electric website.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/product-range-download/548-ecostruxure%E2%84%A2-control-expert/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control\u0026selected-node-id=12365959203#/software-firmware-tab"
},
{
"category": "mitigation",
"details": "In the option dialog box of the PLC simulator, set the listening IP Address to 127.0.0.1 (localhost), which will prevent remote network connections to the PLC simulator.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "The default listening IP address is: 0.0.0.0. The default setting exposes the PLC to the vulnerability described in this advisory.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Schneider Electric recommends using appropriate patching methodologies when applying these patches. It also strongly recommends the use of back-ups and evaluating the impact of these patches in a test and development environment or on offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center for assistance removing a patch.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/work/support/country-selector/contact-us.jsp"
},
{
"category": "mitigation",
"details": "If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Set up network segmentation and implement a firewall to block all unauthorized access to Port 502/TCP",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Harden the engineering workstation running PLC Simulator for EcoStruxure Control Expert",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Follow workstation, network, and site-hardening guidelines in the Cybersecurity Best Practices guide.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/download/document/CS-Best-Practices-2019-340/"
},
{
"category": "mitigation",
"details": "Please see Schneider Electric Security Notification number SEVD-2020-315-07 for more information.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.schneider-electric.com/ww/en/download/document/SEVD-2020-315-07"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
cnvd-2021-31183
Vulnerability from cnvd
厂商已发布了漏洞修复程序,请及时关注更新:https://www.se.com/ww/en/download/document/SEVD-2020-315-07/
| Name | Schneider Electric EcoStruxure Control Expert null |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2020-7538",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2020-7538"
}
},
"description": "Schneider Electric EcoStruxure Control Expert\uff08\u524d\u79f0Unity Pro\uff09\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u5957\u7528\u4e8eSchneider Electric\u903b\u8f91\u63a7\u5236\u5668\u4ea7\u54c1\u7684\u7f16\u7a0b\u8f6f\u4ef6\u3002\n\nEcoStruxure Control Expert \u7684PLC\u6a21\u62df\u5668\u4e2d\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5f53\u901a\u8fc7Modbus\u6536\u5230\u4e00\u4e2a\u7279\u522b\u5236\u4f5c\u7684\u8bf7\u6c42\u65f6\uff0c\u4f1a\u5bfc\u81f4EcoStruxure Control Expert\u8f6f\u4ef6\u4e2d\u7684PLC\u6a21\u62df\u5668\u5d29\u6e83\u3002\u76ee\u524d\u6ca1\u6709\u8be6\u7ec6\u7684\u6f0f\u6d1e\u7ec6\u8282\u63d0\u4f9b\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1ahttps://www.se.com/ww/en/download/document/SEVD-2020-315-07/",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-31183",
"openTime": "2021-04-26",
"patchDescription": "Schneider Electric EcoStruxure Control Expert\uff08\u524d\u79f0Unity Pro\uff09\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u5957\u7528\u4e8eSchneider Electric\u903b\u8f91\u63a7\u5236\u5668\u4ea7\u54c1\u7684\u7f16\u7a0b\u8f6f\u4ef6\u3002\r\n\r\nEcoStruxure Control Expert \u7684PLC\u6a21\u62df\u5668\u4e2d\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5f53\u901a\u8fc7Modbus\u6536\u5230\u4e00\u4e2a\u7279\u522b\u5236\u4f5c\u7684\u8bf7\u6c42\u65f6\uff0c\u4f1a\u5bfc\u81f4EcoStruxure Control Expert\u8f6f\u4ef6\u4e2d\u7684PLC\u6a21\u62df\u5668\u5d29\u6e83\u3002\u76ee\u524d\u6ca1\u6709\u8be6\u7ec6\u7684\u6f0f\u6d1e\u7ec6\u8282\u63d0\u4f9b\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric EcoStruxure Control Expert PLC\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Schneider Electric EcoStruxure Control Expert null"
},
"referenceLink": "https://us-cert.cisa.gov/ics/advisories/icsa-20-315-03",
"serverity": "\u4e2d",
"submitTime": "2020-11-12",
"title": "Schneider Electric EcoStruxure Control Expert PLC\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e"
}
ghsa-6xcf-xj69-qm4j
Vulnerability from github
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus.
{
"affected": [],
"aliases": [
"CVE-2020-7538"
],
"database_specific": {
"cwe_ids": [
"CWE-754"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-11-19T22:15:00Z",
"severity": "HIGH"
},
"details": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus.",
"id": "GHSA-6xcf-xj69-qm4j",
"modified": "2022-05-24T22:28:20Z",
"published": "2022-05-24T22:28:20Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-7538"
},
{
"type": "WEB",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07"
}
],
"schema_version": "1.4.0",
"severity": []
}
fkie_cve-2020-7538
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2020-315-07/ | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2020-315-07/ | Patch, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | ecostruxure_control_expert | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"matchCriteriaId": "18E8CCC1-A467-4FEF-964D-8481EAE892EC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus."
},
{
"lang": "es",
"value": "CWE-754: Se presenta una vulnerabilidad Comprobaci\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales en el Simulador de PLC en EcoStruxure\u00aa Control Expert (ahora Unity Pro) (todas las versiones) que podr\u00eda causar un bloqueo del simulador de PLC presente en el software EcoStruxure\u00aa Control Expert cuando recibe una petici\u00f3n especialmente dise\u00f1ada mediante Modbus"
}
],
"id": "CVE-2020-7538",
"lastModified": "2024-11-21T05:37:20.313",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-19T22:15:14.020",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-754"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
gsd-2020-7538
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2020-7538",
"description": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus.",
"id": "GSD-2020-7538"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-7538"
],
"details": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus.",
"id": "GSD-2020-7538",
"modified": "2023-12-13T01:21:51.673570Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7538",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) ",
"version": {
"version_data": [
{
"version_value": "PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7538"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxure\u00aa Control Expert software when receiving a specially crafted request over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-754"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/",
"refsource": "MISC",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2022-01-31T19:33Z",
"publishedDate": "2020-11-19T22:15Z"
}
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.