cve-2020-3558
Vulnerability from cvelistv5
Published
2020-10-21 18:41
Modified
2024-11-13 17:45
Severity ?
EPSS score ?
Summary
Cisco Firepower Management Center Software Open Redirect Vulnerability
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Cisco | Cisco Firepower Management Center |
Version: n/a |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T07:37:55.314Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "20201021 Cisco Firepower Management Center Software Open Redirect Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-redirect-NYDuSEQn" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2020-3558", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-13T17:22:42.836449Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-13T17:45:51.860Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Cisco Firepower Management Center", "vendor": "Cisco", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2020-10-21T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to redirect a user to a malicious web page. The vulnerability is due to improper input validation of the parameters of an HTTP request. An attacker could exploit this vulnerability by intercepting an HTTP request from a user. A successful exploit could allow the attacker to modify the HTTP request to cause the interface to redirect the user to a specific, malicious URL. This type of vulnerability is known as an open redirect attack and is used in phishing attacks that get users to unknowingly visit malicious sites." } ], "exploits": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:L/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-601", "description": "CWE-601", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-21T18:41:19", "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco" }, "references": [ { "name": "20201021 Cisco Firepower Management Center Software Open Redirect Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-redirect-NYDuSEQn" } ], "source": { "advisory": "cisco-sa-fmc-redirect-NYDuSEQn", "defect": [ [ "CSCvs71766" ] ], "discovery": "INTERNAL" }, "title": "Cisco Firepower Management Center Software Open Redirect Vulnerability", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2020-10-21T16:00:00", "ID": "CVE-2020-3558", "STATE": "PUBLIC", "TITLE": "Cisco Firepower Management Center Software Open Redirect Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco Firepower Management Center", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to redirect a user to a malicious web page. The vulnerability is due to improper input validation of the parameters of an HTTP request. An attacker could exploit this vulnerability by intercepting an HTTP request from a user. A successful exploit could allow the attacker to modify the HTTP request to cause the interface to redirect the user to a specific, malicious URL. This type of vulnerability is known as an open redirect attack and is used in phishing attacks that get users to unknowingly visit malicious sites." } ] }, "exploit": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "impact": { "cvss": { "baseScore": "4.7", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:L/A:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-601" } ] } ] }, "references": { "reference_data": [ { "name": "20201021 Cisco Firepower Management Center Software Open Redirect Vulnerability", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-redirect-NYDuSEQn" } ] }, "source": { "advisory": "cisco-sa-fmc-redirect-NYDuSEQn", "defect": [ [ "CSCvs71766" ] ], "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "assignerShortName": "cisco", "cveId": "CVE-2020-3558", "datePublished": "2020-10-21T18:41:19.253965Z", "dateReserved": "2019-12-12T00:00:00", "dateUpdated": "2024-11-13T17:45:51.860Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-3558\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2020-10-21T19:15:17.700\",\"lastModified\":\"2024-11-26T16:09:02.407\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to redirect a user to a malicious web page. The vulnerability is due to improper input validation of the parameters of an HTTP request. An attacker could exploit this vulnerability by intercepting an HTTP request from a user. A successful exploit could allow the attacker to modify the HTTP request to cause the interface to redirect the user to a specific, malicious URL. This type of vulnerability is known as an open redirect attack and is used in phishing attacks that get users to unknowingly visit malicious sites.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la interfaz de administraci\u00f3n basada en web de Cisco Firepower Management Center (FMC) Software, podr\u00eda permitir a un atacante remoto no autenticado redireccionar a un usuario a una p\u00e1gina web maliciosa.\u0026#xa0;La vulnerabilidad es debido a una comprobaci\u00f3n de entrada inapropiada de los par\u00e1metros de una petici\u00f3n HTTP.\u0026#xa0;Un atacante podr\u00eda explotar esta vulnerabilidad al interceptar una petici\u00f3n HTTP de un usuario.\u0026#xa0;Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir a un atacante modificar la petici\u00f3n HTTP para causar que la interfaz redireccione al usuario hacia una URL maliciosa espec\u00edfica.\u0026#xa0;Este tipo de vulnerabilidad se conoce como ataque de redireccionamiento abierto y se utiliza en ataques de phishing que hacen que los usuarios visiten sitios maliciosos sin saberlo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:L/A:N\",\"baseScore\":4.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:N\",\"baseScore\":5.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.2.0\",\"versionEndIncluding\":\"6.2.3.16\",\"matchCriteriaId\":\"3782E2FD-3E18-4D96-B243-42B6F8A0C883\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.3.0\",\"versionEndIncluding\":\"6.3.0.5\",\"matchCriteriaId\":\"129717CC-A91F-4F05-8096-E9CABDFE6F6F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.4.0\",\"versionEndIncluding\":\"6.4.0.9\",\"matchCriteriaId\":\"FB852BE9-C84E-4BE7-A74F-A65166974BE6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.5.0\",\"versionEndIncluding\":\"6.5.0.4\",\"matchCriteriaId\":\"F687AF0D-BC58-4B9B-85CD-08C6BDD3C101\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-redirect-NYDuSEQn\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-redirect-NYDuSEQn\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.