Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-28387 (GCVE-0-2020-28387)
Vulnerability from cvelistv5
- CWE-611 - Improper Restriction of XML External Entity Reference
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Solid Edge SE2020 |
Version: All Versions < SE2020MP13 |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:33:59.035Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Solid Edge SE2020", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c SE2020MP13" } ] }, { "product": "Solid Edge SE2021", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c SE2021MP3" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-611", "description": "CWE-611: Improper Restriction of XML External Entity Reference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-04-22T20:42:20", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-28387", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Solid Edge SE2020", "version": { "version_data": [ { "version_value": "All Versions \u003c SE2020MP13" } ] } }, { "product_name": "Solid Edge SE2021", "version": { "version_data": [ { "version_value": "All Versions \u003c SE2021MP3" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-611: Improper Restriction of XML External Entity Reference" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-28387", "datePublished": "2021-03-15T17:03:30", "dateReserved": "2020-11-10T00:00:00", "dateUpdated": "2024-08-04T16:33:59.035Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-28387\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-03-15T17:15:20.660\",\"lastModified\":\"2024-11-21T05:22:42.013\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP13), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP3).\u0026#xa0;Cuando se abre un archivo SEECTCXML especialmente dise\u00f1ado, la aplicaci\u00f3n podr\u00eda divulgar archivos arbitrarios a atacantes remotos.\u0026#xa0;Esto es debido al paso de contenido especialmente dise\u00f1ado hacia el analizador XML subyacente sin tomar las restricciones apropiadas, como prohibir un dtd externo.\u0026#xa0;(ZDI?CAN?11923)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-611\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"se2021\",\"matchCriteriaId\":\"576A303A-66CA-4694-AA54-9EB0137C24F1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*\",\"matchCriteriaId\":\"49F5649A-349C-42C6-AFFF-CEE1ABC14E67\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
fkie_cve-2020-28387
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
siemens | solid_edge | * | |
siemens | solid_edge | se2021 | |
siemens | solid_edge | se2021 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*", "matchCriteriaId": "576A303A-66CA-4694-AA54-9EB0137C24F1", "versionEndExcluding": "se2021", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*", "matchCriteriaId": "39D237BD-EE55-4B40-ABC3-194C4BF7C6CD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*", "matchCriteriaId": "49F5649A-349C-42C6-AFFF-CEE1ABC14E67", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)" }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP13), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP3).\u0026#xa0;Cuando se abre un archivo SEECTCXML especialmente dise\u00f1ado, la aplicaci\u00f3n podr\u00eda divulgar archivos arbitrarios a atacantes remotos.\u0026#xa0;Esto es debido al paso de contenido especialmente dise\u00f1ado hacia el analizador XML subyacente sin tomar las restricciones apropiadas, como prohibir un dtd externo.\u0026#xa0;(ZDI?CAN?11923)" } ], "id": "CVE-2020-28387", "lastModified": "2024-11-21T05:22:42.013", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-15T17:15:20.660", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-611" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
gsd-2020-28387
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2020-28387", "description": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)", "id": "GSD-2020-28387" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-28387" ], "details": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)", "id": "GSD-2020-28387", "modified": "2023-12-13T01:22:01.347018Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-28387", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Solid Edge SE2020", "version": { "version_data": [ { "version_value": "All Versions \u003c SE2020MP13" } ] } }, { "product_name": "Solid Edge SE2021", "version": { "version_data": [ { "version_value": "All Versions \u003c SE2021MP3" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-611: Improper Restriction of XML External Entity Reference" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "se2021", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-28387" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-611" } ] } ] }, "references": { "reference_data": [ { "name": "N/A", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6 } }, "lastModifiedDate": "2021-07-15T18:00Z", "publishedDate": "2021-03-15T17:15Z" } } }
icsa-21-068-09
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." }, { "organization": "Trend Micro Zero Day Initiative", "summary": "coordinated disclosure" }, { "organization": "Cybersecurity and Infrastructure Security Agency (CISA)", "summary": "coordination efforts" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Siemens has released new versions for Solid Edge to fix multiple vulnerabilities that could be triggered when the application reads files in different file formats (PAR, DFT, XML extensions). If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and potentially also to arbitrary code execution or data extraction on the target host system.\n\nSiemens recommends to update to the latest version and to avoid opening of untrusted files from unknown sources. Please refer to SSA-574442 for further information regarding latest version update.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-715184.json" }, { "category": "self", "summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-715184.txt" }, { "category": "self", "summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-068-09 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-068-09.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-068-09 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-068-09" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Solid Edge File Parsing", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-068-09", "initial_release_date": "2021-03-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-03-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2021-04-13T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Included fix information for CVE-2020-28385 and CVE-2021-27380, and reference to new advisory SSA-574442" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "3", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cSE2020MP13", "product": { "name": "Solid Edge SE2020", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Solid Edge SE2020" }, { "branches": [ { "category": "product_version_range", "name": "\u003cSE2021MP3", "product": { "name": "Solid Edge SE2021", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Solid Edge SE2021" }, { "branches": [ { "category": "product_version_range", "name": "SE2021MP3", "product": { "name": "Solid Edge SE2021", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Solid Edge SE2021" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-28385", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "summary": "CVE-2020-28385 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28385.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2020MP13 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP3 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP4 or later version", "product_ids": [ "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-28385" }, { "cve": "CVE-2020-28387", "cwe": { "id": "CWE-611", "name": "Improper Restriction of XML External Entity Reference" }, "notes": [ { "category": "summary", "text": "When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-28387 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28387.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2020MP13 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP3 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-28387" }, { "cve": "CVE-2021-27380", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "summary": "CVE-2021-27380 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27380.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2020MP13 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP3 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP4 or later version", "product_ids": [ "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2021-27380" }, { "cve": "CVE-2021-27381", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-27381 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27381.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2020MP13 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP3 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-27381" } ] }
ICSA-21-068-09
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." }, { "organization": "Trend Micro Zero Day Initiative", "summary": "coordinated disclosure" }, { "organization": "Cybersecurity and Infrastructure Security Agency (CISA)", "summary": "coordination efforts" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Siemens has released new versions for Solid Edge to fix multiple vulnerabilities that could be triggered when the application reads files in different file formats (PAR, DFT, XML extensions). If a user is tricked to open a malicious file with the affected application, this could lead to a crash, and potentially also to arbitrary code execution or data extraction on the target host system.\n\nSiemens recommends to update to the latest version and to avoid opening of untrusted files from unknown sources. Please refer to SSA-574442 for further information regarding latest version update.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-715184.json" }, { "category": "self", "summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-715184.txt" }, { "category": "self", "summary": "SSA-715184: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-068-09 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-068-09.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-068-09 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-068-09" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Solid Edge File Parsing", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-068-09", "initial_release_date": "2021-03-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-03-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2021-04-13T00:00:00.000000Z", "legacy_version": "1.1", "number": "2", "summary": "Included fix information for CVE-2020-28385 and CVE-2021-27380, and reference to new advisory SSA-574442" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "3", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cSE2020MP13", "product": { "name": "Solid Edge SE2020", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Solid Edge SE2020" }, { "branches": [ { "category": "product_version_range", "name": "\u003cSE2021MP3", "product": { "name": "Solid Edge SE2021", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Solid Edge SE2021" }, { "branches": [ { "category": "product_version_range", "name": "SE2021MP3", "product": { "name": "Solid Edge SE2021", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Solid Edge SE2021" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-28385", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "summary": "CVE-2020-28385 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28385.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2020MP13 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP3 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP4 or later version", "product_ids": [ "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-28385" }, { "cve": "CVE-2020-28387", "cwe": { "id": "CWE-611", "name": "Improper Restriction of XML External Entity Reference" }, "notes": [ { "category": "summary", "text": "When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-28387 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28387.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2020MP13 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP3 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-28387" }, { "cve": "CVE-2021-27380", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "summary": "CVE-2021-27380 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27380.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2020MP13 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP3 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP4 or later version", "product_ids": [ "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2021-27380" }, { "cve": "CVE-2021-27381", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-27381 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-27381.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2020MP13 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to SE2021MP3 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Applying a Defense-in-Depth concept can help to reduce the probability that untrusted code is run on the system. Siemens recommends to apply the Defense-in-Depth concept: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-27381" } ] }
ghsa-cfhw-x225-jrhr
Vulnerability from github
A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)
{ "affected": [], "aliases": [ "CVE-2020-28387" ], "database_specific": { "cwe_ids": [ "CWE-611" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-03-15T17:15:00Z", "severity": "MODERATE" }, "details": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)", "id": "GHSA-cfhw-x225-jrhr", "modified": "2022-05-24T17:44:32Z", "published": "2022-05-24T17:44:32Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-28387" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" } ], "schema_version": "1.4.0", "severity": [] }
var-202103-0230
Vulnerability from variot
A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923). Zero Day Initiative To this vulnerability ZDI-CAN-11923 Was numbered.Information may be obtained. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SEECTCXML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process
Show details on source website{ "affected_products": { "_id": null, "data": [ { "_id": null, "model": "solid edge", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "se2021" }, { "_id": null, "model": "solid edge", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "se2021" }, { "_id": null, "model": "solid edge", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "se2021mp3" }, { "_id": null, "model": "solid edge", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "se2020mp13" }, { "_id": null, "model": "solid edge", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "_id": null, "model": "solid edge viewer", "scope": null, "trust": 0.7, "vendor": "siemens", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-266" }, { "db": "JVNDB", "id": "JVNDB-2020-016316" }, { "db": "NVD", "id": "CVE-2020-28387" } ] }, "configurations": { "_id": null, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "se2021", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-28387" } ] }, "credits": { "_id": null, "data": "rgod", "sources": [ { "db": "ZDI", "id": "ZDI-21-266" } ], "trust": 0.7 }, "cve": "CVE-2020-28387", "cvss": { "_id": null, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-28387", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 1.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2020-28387", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-28387", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2020-28387", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-28387", "trust": 1.8, "value": "Medium" }, { "author": "ZDI", "id": "CVE-2020-28387", "trust": 0.7, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202103-696", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-266" }, { "db": "JVNDB", "id": "JVNDB-2020-016316" }, { "db": "CNNVD", "id": "CNNVD-202103-696" }, { "db": "NVD", "id": "CVE-2020-28387" } ] }, "description": { "_id": null, "data": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923). Zero Day Initiative To this vulnerability ZDI-CAN-11923 Was numbered.Information may be obtained. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SEECTCXML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process", "sources": [ { "db": "NVD", "id": "CVE-2020-28387" }, { "db": "JVNDB", "id": "JVNDB-2020-016316" }, { "db": "ZDI", "id": "ZDI-21-266" } ], "trust": 2.25 }, "external_ids": { "_id": null, "data": [ { "db": "NVD", "id": "CVE-2020-28387", "trust": 3.1 }, { "db": "SIEMENS", "id": "SSA-715184", "trust": 1.6 }, { "db": "ZDI", "id": "ZDI-21-266", "trust": 1.3 }, { "db": "JVN", "id": "JVNVU93441670", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-016316", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-11923", "trust": 0.7 }, { "db": "ICS CERT", "id": "ICSA-21-068-09", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.0854", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202103-696", "trust": 0.6 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-266" }, { "db": "JVNDB", "id": "JVNDB-2020-016316" }, { "db": "CNNVD", "id": "CNNVD-202103-696" }, { "db": "NVD", "id": "CVE-2020-28387" } ] }, "id": "VAR-202103-0230", "iot": { "_id": null, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.19128205 }, "last_update_date": "2022-05-04T08:13:28.253000Z", "patch": { "_id": null, "data": [ { "title": "SSA-715184", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" }, { "title": "Siemens has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-09" }, { "title": "Siemens Solid Edge Fixes for code issue vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=144058" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-266" }, { "db": "JVNDB", "id": "JVNDB-2020-016316" }, { "db": "CNNVD", "id": "CNNVD-202103-696" } ] }, "problemtype_data": { "_id": null, "data": [ { "problemtype": "CWE-611", "trust": 1.0 }, { "problemtype": "XML Improper restrictions on external entity references (CWE-611) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-016316" }, { "db": "NVD", "id": "CVE-2020-28387" } ] }, "references": { "_id": null, "data": [ { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28387" }, { "trust": 1.3, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-09" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu93441670/" }, { "trust": 0.6, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-266/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.0854" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-266" }, { "db": "JVNDB", "id": "JVNDB-2020-016316" }, { "db": "CNNVD", "id": "CNNVD-202103-696" }, { "db": "NVD", "id": "CVE-2020-28387" } ] }, "sources": { "_id": null, "data": [ { "db": "ZDI", "id": "ZDI-21-266", "ident": null }, { "db": "JVNDB", "id": "JVNDB-2020-016316", "ident": null }, { "db": "CNNVD", "id": "CNNVD-202103-696", "ident": null }, { "db": "NVD", "id": "CVE-2020-28387", "ident": null } ] }, "sources_release_date": { "_id": null, "data": [ { "date": "2021-03-11T00:00:00", "db": "ZDI", "id": "ZDI-21-266", "ident": null }, { "date": "2021-11-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-016316", "ident": null }, { "date": "2021-03-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-696", "ident": null }, { "date": "2021-03-15T17:15:00", "db": "NVD", "id": "CVE-2020-28387", "ident": null } ] }, "sources_update_date": { "_id": null, "data": [ { "date": "2021-03-11T00:00:00", "db": "ZDI", "id": "ZDI-21-266", "ident": null }, { "date": "2021-11-22T09:06:00", "db": "JVNDB", "id": "JVNDB-2020-016316", "ident": null }, { "date": "2021-03-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-696", "ident": null }, { "date": "2021-07-15T18:00:00", "db": "NVD", "id": "CVE-2020-28387", "ident": null } ] }, "threat_type": { "_id": null, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-696" } ], "trust": 0.6 }, "title": { "_id": null, "data": "Solid\u00a0Edge\u00a0 In \u00a0XML\u00a0 External entity vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-016316" } ], "trust": 0.8 }, "type": { "_id": null, "data": "code problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-696" } ], "trust": 0.6 } }
cnvd-2021-16440
Vulnerability from cnvd
Title: Siemens Solid Edge XML外部实体引用漏洞
Description:
Siemens Solid Edge是德国Siemens公司的一款三维CAD软件。该软件可用于零件设计、装配设计、钣金设计、焊接设计等行业。
Siemens Solid Edge存在XML外部实体引用漏洞。该漏洞源于当打开特制的SEECTC XML文件时,攻击者可利用漏洞获取任意文件。
Severity: 中
Patch Name: Siemens Solid Edge XML外部实体引用漏洞的补丁
Patch Description:
Siemens Solid Edge是德国Siemens公司的一款三维CAD软件。该软件可用于零件设计、装配设计、钣金设计、焊接设计等行业。
Siemens Solid Edge存在XML外部实体引用漏洞。该漏洞源于当打开特制的SEECTC XML文件时,攻击者可利用漏洞获取任意文件。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description:
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf
Reference: https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf
Name | ['Siemens Solid Edge SE2020 < SE2020MP13', 'Siemens Solid Edge SE2021 < SE2021MP3'] |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2020-28387" } }, "description": "Siemens Solid Edge\u662f\u5fb7\u56fdSiemens\u516c\u53f8\u7684\u4e00\u6b3e\u4e09\u7ef4CAD\u8f6f\u4ef6\u3002\u8be5\u8f6f\u4ef6\u53ef\u7528\u4e8e\u96f6\u4ef6\u8bbe\u8ba1\u3001\u88c5\u914d\u8bbe\u8ba1\u3001\u94a3\u91d1\u8bbe\u8ba1\u3001\u710a\u63a5\u8bbe\u8ba1\u7b49\u884c\u4e1a\u3002\n\nSiemens Solid Edge\u5b58\u5728XML\u5916\u90e8\u5b9e\u4f53\u5f15\u7528\u6f0f\u6d1e\u3002\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5f53\u6253\u5f00\u7279\u5236\u7684SEECTC XML\u6587\u4ef6\u65f6\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u83b7\u53d6\u4efb\u610f\u6587\u4ef6\u3002", "formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2021-16440", "openTime": "2021-03-11", "patchDescription": "Siemens Solid Edge\u662f\u5fb7\u56fdSiemens\u516c\u53f8\u7684\u4e00\u6b3e\u4e09\u7ef4CAD\u8f6f\u4ef6\u3002\u8be5\u8f6f\u4ef6\u53ef\u7528\u4e8e\u96f6\u4ef6\u8bbe\u8ba1\u3001\u88c5\u914d\u8bbe\u8ba1\u3001\u94a3\u91d1\u8bbe\u8ba1\u3001\u710a\u63a5\u8bbe\u8ba1\u7b49\u884c\u4e1a\u3002\r\n\r\nSiemens Solid Edge\u5b58\u5728XML\u5916\u90e8\u5b9e\u4f53\u5f15\u7528\u6f0f\u6d1e\u3002\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5f53\u6253\u5f00\u7279\u5236\u7684SEECTC XML\u6587\u4ef6\u65f6\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u83b7\u53d6\u4efb\u610f\u6587\u4ef6\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens Solid Edge XML\u5916\u90e8\u5b9e\u4f53\u5f15\u7528\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": [ "Siemens Solid Edge SE2020 \u003c SE2020MP13", "Siemens Solid Edge SE2021 \u003c SE2021MP3" ] }, "referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf", "serverity": "\u4e2d", "submitTime": "2021-03-09", "title": "Siemens Solid Edge XML\u5916\u90e8\u5b9e\u4f53\u5f15\u7528\u6f0f\u6d1e" }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.