Summary
OpenClinic GA versions 5.09.02 and 5.89.05b may allow an attacker to bypass client-side access controls or use a crafted request to initiate a session with limited functionality, which may allow execution of admin functions such as SQL queries.
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:46:34.594Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-184-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OpenClinic GA",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 5.09.02 and 5.89.05b"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "OpenClinic GA versions 5.09.02 and 5.89.05b may allow an attacker to bypass client-side access controls or use a crafted request to initiate a session with limited functionality, which may allow execution of admin functions such as SQL queries."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-288",
              "description": "AUTHENTICATION BYPASS USING AN ALTERNATE PATH OR CHANNEL CWE-288",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-20T14:45:10",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-184-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-14485",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "OpenClinic GA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions 5.09.02 and 5.89.05b"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "OpenClinic GA versions 5.09.02 and 5.89.05b may allow an attacker to bypass client-side access controls or use a crafted request to initiate a session with limited functionality, which may allow execution of admin functions such as SQL queries."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "AUTHENTICATION BYPASS USING AN ALTERNATE PATH OR CHANNEL CWE-288"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-184-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-184-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-14485",
    "datePublished": "2020-07-20T14:45:10",
    "dateReserved": "2020-06-19T00:00:00",
    "dateUpdated": "2024-08-04T12:46:34.594Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-14485\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-07-20T15:15:12.740\",\"lastModified\":\"2024-11-21T05:03:22.423\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"OpenClinic GA versions 5.09.02 and 5.89.05b may allow an attacker to bypass client-side access controls or use a crafted request to initiate a session with limited functionality, which may allow execution of admin functions such as SQL queries.\"},{\"lang\":\"es\",\"value\":\"OpenClinic GA versiones 5.09.02 y 5.89.05b, pueden permitir a un atacante omitir los controles de acceso del lado del cliente o usar una petici\u00f3n dise\u00f1ada para iniciar una sesi\u00f3n con una funcionalidad limitada, lo que puede permitir una ejecuci\u00f3n de funcionalidades administrativas tales como consultas SQL\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-288\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:openclinic_ga_project:openclinic_ga:5.09.02:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A64E5CCD-1F0D-46B2-9AE7-C917928D2788\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:openclinic_ga_project:openclinic_ga:5.89.05b:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BE2E5CDB-B864-45E4-A7EA-D7EE93BC2453\"}]}]}],\"references\":[{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsma-20-184-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsma-20-184-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.