Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-10039 (GCVE-0-2020-10039)
Vulnerability from cvelistv5
- CWE-311 - Missing Encryption of Sensitive Data
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Siemens AG | SICAM MMU |
Version: All versions < V2.05 |
||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.303Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICAM MMU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.05" } ] }, { "product": "SICAM SGU", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SICAM T", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V2.18" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-311", "description": "CWE-311: Missing Encryption of Sensitive Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:04", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10039", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM MMU", "version": { "version_data": [ { "version_value": "All versions \u003c V2.05" } ] } }, { "product_name": "SICAM SGU", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SICAM T", "version": { "version_data": [ { "version_value": "All versions \u003c V2.18" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-311: Missing Encryption of Sensitive Data" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10039", "datePublished": "2020-07-14T13:18:04", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.303Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-10039\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2020-07-14T14:15:16.620\",\"lastModified\":\"2024-11-21T04:54:41.423\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SICAM MMU (Todas las versiones anteriores a V2.05), SICAM SGU (Todas las versiones), SICAM T (Todas las versiones anteriores a V2.18). Un atacante en una posici\u00f3n de red privilegiada entre un usuario leg\u00edtimo y el servidor web podr\u00eda ser capaz de conducir un ataque de tipo Man-in-the-middle y conseguir acceso de lectura y escritura a los datos transmitidos\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-311\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-311\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.05\",\"matchCriteriaId\":\"3C67031A-9052-4B6F-8AC9-326B716B99CE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FD81E558-D52F-4BFF-B8B4-979B887E0A1B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"249B469D-3B32-47EF-ABBC-615DC0522006\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F176093C-96F4-47E9-B287-46C8275BD392\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.18\",\"matchCriteriaId\":\"4E7EABA4-5C46-4BCD-9904-EB175BC597DA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B7E06863-36F6-4E8F-B038-2F17032987FA\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
ICSA-20-196-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." }, { "names": [ "Luca Simbrger", "Luca Hofschuster", "Lukas Kahnert", "Jakob Lachermeier", "Christian Costa", "Simon Huber", "Lukas Sas Brunschier", "Florian Freiberger", "Florian Burger", "Marie-Louise Oostveen", "Magdalena Thomeczek", "Johann Uhrmann" ], "organization": "Landshut University of Applied Sciences", "summary": "coordinating disclosure of CVE-2020-10037" }, { "names": [ "Max Hirschberger", "Simon Hofmann", "Peter Knauer" ], "organization": "Augsburg University of Applied Sciences", "summary": "for coordinating disclosure of CVE-2020-10038 to CVE-2020-10045" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "general", "text": "Operators of critical power systems (e.g.\u0027TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g.\u0027firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Digital Grid Products can be found at:", "title": "General Recommendations" }, { "category": "general", "text": "https://www.siemens.com/gridsecurity", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from a Siemens ProductCERT\u0027s advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-305120: Vulnerabilities in SICAM MMU, SICAM T and SICAM SGU - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-305120.html" }, { "category": "self", "summary": "ICS Advisory ICSA-20-196-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-196-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-20-196-03 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-196-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SICAM MMU, SICAM T, and SICAM SGU", "tracking": { "current_release_date": "2020-07-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-20-196-03", "initial_release_date": "2020-07-14T00:00:00.000000Z", "revision_history": [ { "date": "2020-07-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2.05", "product": { "name": "Siemens SICAM MMU: All versions \u003c V2.05", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SICAM MMU" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Siemens SICAM SGU: All versions", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SICAM SGU" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.18", "product": { "name": "Siemens SICAM T: All versions \u003c V2.18", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SICAM T" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-10037", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10037" }, { "cve": "CVE-2020-10038", "cwe": { "id": "CWE-306", "name": "Missing Authentication for Critical Function" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10038" }, { "cve": "CVE-2020-10039", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10039" }, { "cve": "CVE-2020-10040", "cwe": { "id": "CWE-916", "name": "Use of Password Hash With Insufficient Computational Effort" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.2, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10040" }, { "cve": "CVE-2020-10041", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10041" }, { "cve": "CVE-2020-10042", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10042" }, { "cve": "CVE-2020-10043", "cwe": { "id": "CWE-80", "name": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:H/A:L/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10043" }, { "cve": "CVE-2020-10044", "cwe": { "id": "CWE-306", "name": "Missing Authentication for Critical Function" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10044" }, { "cve": "CVE-2020-10045", "cwe": { "id": "CWE-294", "name": "Authentication Bypass by Capture-replay" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10045" } ] }
icsa-20-196-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." }, { "names": [ "Luca Simbrger", "Luca Hofschuster", "Lukas Kahnert", "Jakob Lachermeier", "Christian Costa", "Simon Huber", "Lukas Sas Brunschier", "Florian Freiberger", "Florian Burger", "Marie-Louise Oostveen", "Magdalena Thomeczek", "Johann Uhrmann" ], "organization": "Landshut University of Applied Sciences", "summary": "coordinating disclosure of CVE-2020-10037" }, { "names": [ "Max Hirschberger", "Simon Hofmann", "Peter Knauer" ], "organization": "Augsburg University of Applied Sciences", "summary": "for coordinating disclosure of CVE-2020-10038 to CVE-2020-10045" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "general", "text": "Operators of critical power systems (e.g.\u0027TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g.\u0027firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines to Digital Grid Products can be found at:", "title": "General Recommendations" }, { "category": "general", "text": "https://www.siemens.com/gridsecurity", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from a Siemens ProductCERT\u0027s advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-305120: Vulnerabilities in SICAM MMU, SICAM T and SICAM SGU - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-305120.html" }, { "category": "self", "summary": "ICS Advisory ICSA-20-196-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-196-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-20-196-03 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-196-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SICAM MMU, SICAM T, and SICAM SGU", "tracking": { "current_release_date": "2020-07-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-20-196-03", "initial_release_date": "2020-07-14T00:00:00.000000Z", "revision_history": [ { "date": "2020-07-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2.05", "product": { "name": "Siemens SICAM MMU: All versions \u003c V2.05", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SICAM MMU" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Siemens SICAM SGU: All versions", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SICAM SGU" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2.18", "product": { "name": "Siemens SICAM T: All versions \u003c V2.18", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SICAM T" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-10037", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10037" }, { "cve": "CVE-2020-10038", "cwe": { "id": "CWE-306", "name": "Missing Authentication for Critical Function" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10038" }, { "cve": "CVE-2020-10039", "cwe": { "id": "CWE-311", "name": "Missing Encryption of Sensitive Data" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10039" }, { "cve": "CVE-2020-10040", "cwe": { "id": "CWE-916", "name": "Use of Password Hash With Insufficient Computational Effort" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.2, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10040" }, { "cve": "CVE-2020-10041", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.6, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10041" }, { "cve": "CVE-2020-10042", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10042" }, { "cve": "CVE-2020-10043", "cwe": { "id": "CWE-80", "name": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:H/A:L/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10043" }, { "cve": "CVE-2020-10044", "cwe": { "id": "CWE-306", "name": "Missing Authentication for Critical Function" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10044" }, { "cve": "CVE-2020-10045", "cwe": { "id": "CWE-294", "name": "Authentication Bypass by Capture-replay" }, "notes": [ { "category": "summary", "text": "By performing a flooding attack against the web server, an attacker might be able to gain read access to the device\u0027s memory, possibly revealing confidential information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "The firmware updates to SICAM T and SICAM MMU introduce authentication to the web application and remove some unnecessary functionality. The web authentication functionality reduces the risk of access to the device\u0027s web application for executing administrative commands by unauthenticated users.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Due to hardware constraints, encryption is not possible on the devices. Confidential data such as passwords handled by the devices need to be protected on the network by other means, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "The risk for remote code execution and unauthenticated firmware installation can be mitigated by ensuring encryption and authentication between the user and the device, e.g.\u0027by VPN.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Using a modern and up to date browser while accessing the web application might reduce the risk of Cross-Site-Scripting attacks.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2.05 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2.18 to introduce authentication in the web application to mitigate some web", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 8.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2020-10045" } ] }
CERTFR-2020-AVI-439
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une élévation de privilèges.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | LOGO! 8 BM (incl. variantes SIPLUS) versions antérieures à V1.82.04 | ||
Siemens | N/A | SIMATIC S7-300 CPU (incl. variantes ET200CPUs et SIPLUS) versions antérieures à V3.X.17 | ||
Siemens | N/A | SIMATIC TDC CP51M1 versions antérieures à V1.1.8 | ||
Siemens | N/A | SICAM T versions antérieures à V2.18 | ||
Siemens | N/A | Opcenter Execution Process versions antérieures à v3.2 | ||
Siemens | N/A | SICAM MMU versions antérieures à V2.05 | ||
Siemens | N/A | Camstar Enterprise Platform : une migration vers Opcenter Execution Core 8.2 est requise | ||
Siemens | N/A | SIMATIC IT LMS, Production Suite, Notifier Server for Windows, PCS neo | ||
Siemens | N/A | SICAM SGU | ||
Siemens | N/A | LOGO! 8 BM (incl. variantes SIPLUS) versions antérieures à V1.82.03 | ||
Siemens | N/A | Opcenter RD&L versions antérieures à 8.1 | ||
Siemens | N/A | SIMATIC WinCC Runtime Advanced | ||
Siemens | N/A | SPPA-T3000 APC UPS avec carte NMC AP9630 ou AP9631 | ||
Siemens | N/A | SIMATIC STEP 7 (TIA Portal) v16 versions antérieures à V16 update 2 | ||
Siemens | N/A | SPPA-T3000 Application Server et Terminal Server | ||
Siemens | N/A | SIMATIC TDC CPU555 versions antérieures à V1.1.1 | ||
Siemens | N/A | Opcenter Execution Discrete versions antérieures à v3.2 | ||
Siemens | N/A | Opcenter Execution Core versions antérieures à v8.2 | ||
Siemens | N/A | SIMATIC S7-200 SMART CPU versions antérieures à V2.5.1 | ||
Siemens | N/A | Opcenter Quality versions antérieures à 11.3 | ||
Siemens | N/A | Opcenter Intelligence | ||
Siemens | N/A | LOGO! 8 BM (incl. variantes SIPLUS) versions antérieures à V1.81.04 | ||
Siemens | N/A | SIMATIC HMI Basic Panels première et seconde génération, Comfort Panels, Mobile Panels de seconde génération (incl. variantes SIPLUS) | ||
Siemens | N/A | SIMATIC STEP 7 (TIA Portal) v15 | ||
Siemens | N/A | SINUMERIK 840D sl versions antérieures à V4.8.6 | ||
Siemens | N/A | SIMATIC HMI KTP700F Mobile Arctic | ||
Siemens | N/A | Opcenter Execution Foundation versions antérieures à v3.2 | ||
Siemens | N/A | SIMOCODE ES et Soft Starter ES | ||
Siemens | N/A | SINUMERIK 840D sl versions antérieures à V4.94 |
Title | Publication Time | Tags | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "LOGO! 8 BM (incl. variantes SIPLUS) versions ant\u00e9rieures \u00e0 V1.82.04", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-300 CPU (incl. variantes ET200CPUs et SIPLUS) versions ant\u00e9rieures \u00e0 V3.X.17", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC TDC CP51M1 versions ant\u00e9rieures \u00e0 V1.1.8", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SICAM T versions ant\u00e9rieures \u00e0 V2.18", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Opcenter Execution Process versions ant\u00e9rieures \u00e0 v3.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SICAM MMU versions ant\u00e9rieures \u00e0 V2.05", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Camstar Enterprise Platform : une migration vers Opcenter Execution Core 8.2 est requise", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC IT LMS, Production Suite, Notifier Server for Windows, PCS neo", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SICAM SGU", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "LOGO! 8 BM (incl. variantes SIPLUS) versions ant\u00e9rieures \u00e0 V1.82.03", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Opcenter RD\u0026L versions ant\u00e9rieures \u00e0 8.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC Runtime Advanced", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SPPA-T3000 APC UPS avec carte NMC AP9630 ou AP9631", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC STEP 7 (TIA Portal) v16 versions ant\u00e9rieures \u00e0 V16 update 2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SPPA-T3000 Application Server et Terminal Server", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC TDC CPU555 versions ant\u00e9rieures \u00e0 V1.1.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Opcenter Execution Discrete versions ant\u00e9rieures \u00e0 v3.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Opcenter Execution Core versions ant\u00e9rieures \u00e0 v8.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC S7-200 SMART CPU versions ant\u00e9rieures \u00e0 V2.5.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Opcenter Quality versions ant\u00e9rieures \u00e0 11.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Opcenter Intelligence", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "LOGO! 8 BM (incl. variantes SIPLUS) versions ant\u00e9rieures \u00e0 V1.81.04", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC HMI Basic Panels premi\u00e8re et seconde g\u00e9n\u00e9ration, Comfort Panels, Mobile Panels de seconde g\u00e9n\u00e9ration (incl. variantes SIPLUS)", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC STEP 7 (TIA Portal) v15", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINUMERIK 840D sl versions ant\u00e9rieures \u00e0 V4.8.6", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC HMI KTP700F Mobile Arctic", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Opcenter Execution Foundation versions ant\u00e9rieures \u00e0 v3.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMOCODE ES et Soft Starter ES", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SINUMERIK 840D sl versions ant\u00e9rieures \u00e0 V4.94", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2020-7584", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7584" }, { "name": "CVE-2020-7577", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7577" }, { "name": "CVE-2020-7587", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7587" }, { "name": "CVE-2020-7576", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7576" }, { "name": "CVE-2019-18336", "url": "https://www.cve.org/CVERecord?id=CVE-2019-18336" }, { "name": "CVE-2020-10042", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10042" }, { "name": "CVE-2020-7592", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7592" }, { "name": "CVE-2020-10043", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10043" }, { "name": "CVE-2020-10045", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10045" }, { "name": "CVE-2020-7578", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7578" }, { "name": "CVE-2020-7588", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7588" }, { "name": "CVE-2020-10044", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10044" }, { "name": "CVE-2020-10041", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10041" }, { "name": "CVE-2020-7581", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7581" }, { "name": "CVE-2020-10039", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10039" }, { "name": "CVE-2020-10038", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10038" }, { "name": "CVE-2020-10040", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10040" }, { "name": "CVE-2020-11896", "url": "https://www.cve.org/CVERecord?id=CVE-2020-11896" }, { "name": "CVE-2020-7593", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7593" }, { "name": "CVE-2020-10037", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10037" }, { "name": "CVE-2020-0545", "url": "https://www.cve.org/CVERecord?id=CVE-2020-0545" } ], "initial_release_date": "2020-07-15T00:00:00", "last_revision_date": "2020-07-15T00:00:00", "links": [], "reference": "CERTFR-2020-AVI-439", "revisions": [ { "description": "Version initiale", "revision_date": "2020-07-15T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Injection de code indirecte \u00e0 distance (XSS)" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" }, { "description": "\u00c9l\u00e9vation de privil\u00e8ges" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une \u00e9l\u00e9vation de privil\u00e8ges.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-589181 du 14 juillet 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589181.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-631949 du 14 juillet 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-631949.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-573753 du 14 juillet 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-573753.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-604937 du 14 juillet 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-604937.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-508982 du 10 mars 2020, mis \u00e0 jour le 14 juillet 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508982.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-841348 du 14 juillet 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-364335 du 14 juillet 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-305120 du 14 juillet 2020", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] }
ghsa-g4pp-mvp2-qf9j
Vulnerability from github
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data.
{ "affected": [], "aliases": [ "CVE-2020-10039" ], "database_specific": { "cwe_ids": [], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2020-07-14T14:15:00Z", "severity": "MODERATE" }, "details": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data.", "id": "GHSA-g4pp-mvp2-qf9j", "modified": "2022-05-24T17:22:49Z", "published": "2022-05-24T17:22:49Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-10039" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "schema_version": "1.4.0", "severity": [] }
var-202007-0037
Vulnerability from variot
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data. SICAM MMU , SGU , T There is a vulnerability in the lack of encryption of critical data.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. SICAM T is a digital measuring sensor that allows the measurement of electricity in non-electrical networks in a single unit. ICAM-MMU (Measurement and Monitoring Unit) is a power monitoring device that allows the measurement of electricity in the power grid in a unit. SICAM SGU (discontinued) is a smart grid remote terminal device with the communication capabilities of power companies and utility companies.
Siemens SICAM MMU, SGU and T have security vulnerabilities
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202007-0037", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sicam sgu", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "sicam sgu", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sicam mmu", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.05" }, { "model": "sicam t", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.18" }, { "model": "sicam mmu", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "2.05" }, { "model": "sicam t", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "2.18" }, { "model": "sicam t", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v2.18" }, { "model": "sicam mmu", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v2.05" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40620" }, { "db": "JVNDB", "id": "JVNDB-2020-007718" }, { "db": "NVD", "id": "CVE-2020-10039" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:sicam_mmu_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sicam_sgu_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sicam_t_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-007718" } ] }, "cve": "CVE-2020-10039", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2020-10039", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 1.0, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-007718", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CNVD-2020-40620", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.2, "id": "CVE-2020-10039", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "High", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.1, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-007718", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-10039", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "JVNDB-2020-007718", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2020-40620", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202007-815", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40620" }, { "db": "JVNDB", "id": "JVNDB-2020-007718" }, { "db": "CNNVD", "id": "CNNVD-202007-815" }, { "db": "NVD", "id": "CVE-2020-10039" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data. SICAM MMU , SGU , T There is a vulnerability in the lack of encryption of critical data.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. SICAM T is a digital measuring sensor that allows the measurement of electricity in non-electrical networks in a single unit. ICAM-MMU (Measurement and Monitoring Unit) is a power monitoring device that allows the measurement of electricity in the power grid in a unit. SICAM SGU (discontinued) is a smart grid remote terminal device with the communication capabilities of power companies and utility companies. \n\r\n\r\nSiemens SICAM MMU, SGU and T have security vulnerabilities", "sources": [ { "db": "NVD", "id": "CVE-2020-10039" }, { "db": "JVNDB", "id": "JVNDB-2020-007718" }, { "db": "CNVD", "id": "CNVD-2020-40620" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-10039", "trust": 3.0 }, { "db": "SIEMENS", "id": "SSA-305120", "trust": 2.2 }, { "db": "ICS CERT", "id": "ICSA-20-196-03", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU97872642", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-007718", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-40620", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.2386", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202007-815", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40620" }, { "db": "JVNDB", "id": "JVNDB-2020-007718" }, { "db": "CNNVD", "id": "CNNVD-202007-815" }, { "db": "NVD", "id": "CVE-2020-10039" } ] }, "id": "VAR-202007-0037", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-40620" } ], "trust": 1.20119045 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40620" } ] }, "last_update_date": "2024-11-23T21:35:25.849000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-305120", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "title": "Patch for Siemens SICAM MMU, SGU and T sensitive information disclosure vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/225827" }, { "title": "Siemens SICAM MMU , SGU and T Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=123871" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40620" }, { "db": "JVNDB", "id": "JVNDB-2020-007718" }, { "db": "CNNVD", "id": "CNNVD-202007-815" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-311", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-007718" }, { "db": "NVD", "id": "CVE-2020-10039" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "trust": 1.4, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-03" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-10039" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-10039" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu97872642/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.2386/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-40620" }, { "db": "JVNDB", "id": "JVNDB-2020-007718" }, { "db": "CNNVD", "id": "CNNVD-202007-815" }, { "db": "NVD", "id": "CVE-2020-10039" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-40620" }, { "db": "JVNDB", "id": "JVNDB-2020-007718" }, { "db": "CNNVD", "id": "CNNVD-202007-815" }, { "db": "NVD", "id": "CVE-2020-10039" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-07-17T00:00:00", "db": "CNVD", "id": "CNVD-2020-40620" }, { "date": "2020-08-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-007718" }, { "date": "2020-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202007-815" }, { "date": "2020-07-14T14:15:16.620000", "db": "NVD", "id": "CVE-2020-10039" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-07-17T00:00:00", "db": "CNVD", "id": "CNVD-2020-40620" }, { "date": "2020-08-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-007718" }, { "date": "2021-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202007-815" }, { "date": "2024-11-21T04:54:41.423000", "db": "NVD", "id": "CVE-2020-10039" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202007-815" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural SICAM Vulnerability in lack of encryption of critical data in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-007718" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202007-815" } ], "trust": 0.6 } }
cnvd-2020-40620
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf
Name | ['Siemens SICAM T < V2.18', 'Siemens SICAM SGU', 'Siemens SICAM MMU < V2.05'] |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2020-10039" } }, "description": "SICAM T\u662f\u4e00\u79cd\u6570\u5b57\u6d4b\u91cf\u4f20\u611f\u5668\uff0c\u5141\u8bb8\u5728\u5355\u4e2a\u5355\u5143\u4e2d\u6d4b\u91cf\u975e\u7535\u6c14\u7f51\u7edc\u4e2d\u7684\u7535\u91cf\u3002ICAM-MMU(Measurement and Monitoring Unit) \u662f\u4e00\u79cd\u529f\u7387\u76d1\u6d4b\u88c5\u7f6e\uff0c\u5b83\u5141\u8bb8\u5728\u4e00\u4e2a\u5355\u5143\u4e2d\u6d4b\u91cf\u7535\u7f51\u4e2d\u7684\u7535\u91cf\u3002SICAM SGU\uff08\u5df2\u505c\u4ea7\uff09\u662f\u4e00\u79cd\u667a\u80fd\u7535\u7f51\u8fdc\u7a0b\u7ec8\u7aef\u8bbe\u5907\uff0c\u5177\u6709\u7535\u529b\u516c\u53f8\u548c\u516c\u7528\u4e8b\u4e1a\u516c\u53f8\u7684\u901a\u4fe1\u80fd\u529b\u3002\n\nSiemens SICAM MMU\u3001SGU\u548cT\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u8fdb\u884c\u4e2d\u95f4\u4eba\u653b\u51fb\uff0c\u5e76\u83b7\u5f97\u5bf9\u4f20\u8f93\u6570\u636e\u7684\u8bfb\u5199\u8bbf\u95ee\u6743\u3002", "formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2020-40620", "openTime": "2020-07-17", "patchDescription": "SICAM T\u662f\u4e00\u79cd\u6570\u5b57\u6d4b\u91cf\u4f20\u611f\u5668\uff0c\u5141\u8bb8\u5728\u5355\u4e2a\u5355\u5143\u4e2d\u6d4b\u91cf\u975e\u7535\u6c14\u7f51\u7edc\u4e2d\u7684\u7535\u91cf\u3002ICAM-MMU(Measurement and Monitoring Unit) \u662f\u4e00\u79cd\u529f\u7387\u76d1\u6d4b\u88c5\u7f6e\uff0c\u5b83\u5141\u8bb8\u5728\u4e00\u4e2a\u5355\u5143\u4e2d\u6d4b\u91cf\u7535\u7f51\u4e2d\u7684\u7535\u91cf\u3002SICAM SGU\uff08\u5df2\u505c\u4ea7\uff09\u662f\u4e00\u79cd\u667a\u80fd\u7535\u7f51\u8fdc\u7a0b\u7ec8\u7aef\u8bbe\u5907\uff0c\u5177\u6709\u7535\u529b\u516c\u53f8\u548c\u516c\u7528\u4e8b\u4e1a\u516c\u53f8\u7684\u901a\u4fe1\u80fd\u529b\u3002\r\n\r\nSiemens SICAM MMU\u3001SGU\u548cT\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u8fdb\u884c\u4e2d\u95f4\u4eba\u653b\u51fb\uff0c\u5e76\u83b7\u5f97\u5bf9\u4f20\u8f93\u6570\u636e\u7684\u8bfb\u5199\u8bbf\u95ee\u6743\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens SICAM MMU\u3001SGU\u548cT\u654f\u611f\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": [ "Siemens SICAM T \u003c V2.18", "Siemens SICAM SGU", "Siemens SICAM MMU \u003c V2.05" ] }, "referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "serverity": "\u4e2d", "submitTime": "2020-07-15", "title": "Siemens SICAM MMU\u3001SGU\u548cT\u654f\u611f\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e" }
fkie_cve-2020-10039
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
siemens | sicam_mmu_firmware | * | |
siemens | sicam_mmu | - | |
siemens | sicam_sgu_firmware | - | |
siemens | sicam_sgu | - | |
siemens | sicam_t_firmware | * | |
siemens | sicam_t | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C67031A-9052-4B6F-8AC9-326B716B99CE", "versionEndExcluding": "2.05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*", "matchCriteriaId": "FD81E558-D52F-4BFF-B8B4-979B887E0A1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "249B469D-3B32-47EF-ABBC-615DC0522006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F176093C-96F4-47E9-B287-46C8275BD392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E7EABA4-5C46-4BCD-9904-EB175BC597DA", "versionEndExcluding": "2.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7E06863-36F6-4E8F-B038-2F17032987FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SICAM MMU (Todas las versiones anteriores a V2.05), SICAM SGU (Todas las versiones), SICAM T (Todas las versiones anteriores a V2.18). Un atacante en una posici\u00f3n de red privilegiada entre un usuario leg\u00edtimo y el servidor web podr\u00eda ser capaz de conducir un ataque de tipo Man-in-the-middle y conseguir acceso de lectura y escritura a los datos transmitidos" } ], "id": "CVE-2020-10039", "lastModified": "2024-11-21T04:54:41.423", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:16.620", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-311" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-311" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
gsd-2020-10039
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2020-10039", "description": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data.", "id": "GSD-2020-10039" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-10039" ], "details": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data.", "id": "GSD-2020-10039", "modified": "2023-12-13T01:22:04.912209Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10039", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICAM MMU", "version": { "version_data": [ { "version_value": "All versions \u003c V2.05" } ] } }, { "product_name": "SICAM SGU", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SICAM T", "version": { "version_data": [ { "version_value": "All versions \u003c V2.18" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-311: Missing Encryption of Sensitive Data" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sicam_mmu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.05", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sicam_mmu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sicam_sgu_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sicam_sgu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sicam_t_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.18", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sicam_t:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10039" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-311" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 5.9 } }, "lastModifiedDate": "2020-07-15T17:06Z", "publishedDate": "2020-07-14T14:15Z" } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.