cve-2019-15280
Vulnerability from cvelistv5
Published
2019-10-16 18:36
Modified
2024-11-21 19:06
Severity ?
EPSS score ?
Summary
Cisco Firepower Management Center Software Stored Cross-Site Scripting Vulnerability
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Cisco | Cisco Firepower Management Center |
Version: unspecified < n/a |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T00:42:03.795Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "20191016 Cisco Firepower Management Center Software Stored Cross-Site Scripting Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-fpwr-xss" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2019-15280", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-21T18:55:59.231923Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-21T19:06:59.043Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Cisco Firepower Management Center", "vendor": "Cisco", "versions": [ { "lessThan": "n/a", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2019-10-16T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based management interface. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting malicious code in certain sections of the interface that are visible to other users. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. An attacker would need valid administrator credentials to exploit this vulnerability." } ], "exploits": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-10-16T18:36:45", "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco" }, "references": [ { "name": "20191016 Cisco Firepower Management Center Software Stored Cross-Site Scripting Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-fpwr-xss" } ], "source": { "advisory": "cisco-sa-20191016-fpwr-xss", "defect": [ [ "CSCvq55915", "CSCvq55919", "CSCvq55929", "CSCvq55933", "CSCvq55938", "CSCvq55941", "CSCvq55946", "CSCvq55958", "CSCvq55967" ] ], "discovery": "INTERNAL" }, "title": "Cisco Firepower Management Center Software Stored Cross-Site Scripting Vulnerability", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2019-10-16T16:00:00-0700", "ID": "CVE-2019-15280", "STATE": "PUBLIC", "TITLE": "Cisco Firepower Management Center Software Stored Cross-Site Scripting Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco Firepower Management Center", "version": { "version_data": [ { "affected": "\u003c", "version_affected": "\u003c", "version_value": "n/a" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based management interface. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting malicious code in certain sections of the interface that are visible to other users. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. An attacker would need valid administrator credentials to exploit this vulnerability." } ] }, "exploit": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "impact": { "cvss": { "baseScore": "4.8", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79" } ] } ] }, "references": { "reference_data": [ { "name": "20191016 Cisco Firepower Management Center Software Stored Cross-Site Scripting Vulnerability", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-fpwr-xss" } ] }, "source": { "advisory": "cisco-sa-20191016-fpwr-xss", "defect": [ [ "CSCvq55915", "CSCvq55919", "CSCvq55929", "CSCvq55933", "CSCvq55938", "CSCvq55941", "CSCvq55946", "CSCvq55958", "CSCvq55967" ] ], "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "assignerShortName": "cisco", "cveId": "CVE-2019-15280", "datePublished": "2019-10-16T18:36:45.621198Z", "dateReserved": "2019-08-20T00:00:00", "dateUpdated": "2024-11-21T19:06:59.043Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-15280\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2019-10-16T19:15:15.253\",\"lastModified\":\"2024-11-26T16:09:02.407\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based management interface. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit this vulnerability by inserting malicious code in certain sections of the interface that are visible to other users. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information. An attacker would need valid administrator credentials to exploit this vulnerability.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la interfaz de administraci\u00f3n basada en web de Cisco Firepower Management Center (FMC) Software, podr\u00eda permitir a un atacante remoto autenticado conducir un ataque de tipo cross-site scripting (XSS) almacenado contra un usuario de la interfaz de administraci\u00f3n basada en web. La vulnerabilidad es debido a una comprobaci\u00f3n insuficiente de la entrada suministrada por el usuario mediante la interfaz de administraci\u00f3n basada en web. Un atacante podr\u00eda explotar esta vulnerabilidad insertando c\u00f3digo malicioso en ciertas secciones de la interfaz que son visibles para otros usuarios. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante ejecutar c\u00f3digo de script arbitrario en el contexto de la interfaz o acceder a informaci\u00f3n confidencial basada en navegador. Un atacante necesitar\u00eda credenciales de administrador v\u00e1lidas para explotar esta vulnerabilidad.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:6.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EEEB9A40-0062-406D-B56D-3163CBBE08D4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:6.2.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6175407A-207E-4844-B150-EA0129C4CBBD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:6.3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"134B9AFF-6FFF-4082-80CB-AD2ACBF832F9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:6.4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"52651664-CA65-4812-8226-E104E1BE7864\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:secure_firewall_management_center:6.5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"60881FF9-5ACA-4097-8177-56B3DE192B2E\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-fpwr-xss\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-fpwr-xss\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.