cve-2019-10989
Vulnerability from cvelistv5
Published
2019-06-28 20:31
Modified
2024-08-04 22:40
Severity ?
EPSS score ?
Summary
In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsa-19-178-05 | Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://www.zerodayinitiative.com/advisories/ZDI-19-590/ | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://www.zerodayinitiative.com/advisories/ZDI-19-591/ | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-178-05 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-19-590/ | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-19-591/ | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | WebAccess | WebAccess/SCADA |
Version: Versions 8.3.5 and prior |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.634Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-178-05" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-590/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-591/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "WebAccess/SCADA", "vendor": "WebAccess", "versions": [ { "status": "affected", "version": "Versions 8.3.5 and prior" } ] } ], "datePublic": "2019-06-27T00:00:00", "descriptions": [ { "lang": "en", "value": "In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991." } ], "problemTypes": [ { "descriptions": [ { "description": "Buffer Overflow", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-07-02T16:06:07", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-178-05" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-590/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-591/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2019-10989", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "WebAccess/SCADA", "version": { "version_data": [ { "version_value": "Versions 8.3.5 and prior" } ] } } ] }, "vendor_name": "WebAccess" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.us-cert.gov/ics/advisories/icsa-19-178-05", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-19-178-05" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-590/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-590/" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-591/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-591/" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2019-10989", "datePublished": "2019-06-28T20:31:48", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.634Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-10989\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2019-06-28T21:15:11.243\",\"lastModified\":\"2024-11-21T04:20:18.283\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991.\"},{\"lang\":\"es\",\"value\":\"En WebAccess/SCADA versiones 8.3.5 y anteriores, m\u00faltiples vulnerabilidades de desbordamiento de b\u00fafer basado en memoria din\u00e1mica (heap) son provocadas por la falta de una validaci\u00f3n correcta de la longitud de los datos proporcionados. La explotaci\u00f3n de estas vulnerabilidades podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo. Nota: Una vulnerabilidad diferente a CVE-2019-10991.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:advantech:webaccess:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"8.3.5\",\"matchCriteriaId\":\"5333F043-09F6-4BAA-9F06-4FFA63406A29\"}]}]}],\"references\":[{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-178-05\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-19-590/\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-19-591/\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-178-05\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-19-590/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-19-591/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.