CVE-2018-7804 (GCVE-0-2018-7804)
Vulnerability from cvelistv5
Published
2018-12-17 22:00
Modified
2024-08-05 06:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- URL Redirection to Untrusted Site
Summary
A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric SE | Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 |
Version: Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T06:37:59.165Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200", "vendor": "Schneider Electric SE", "versions": [ { "status": "affected", "version": "Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200" } ] } ], "datePublic": "2018-12-17T00:00:00", "descriptions": [ { "lang": "en", "value": "A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker\u0027s choosing." } ], "problemTypes": [ { "descriptions": [ { "description": "URL Redirection to Untrusted Site", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-12-17T21:57:01", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2018-7804", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200", "version": { "version_data": [ { "version_value": "Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200" } ] } } ] }, "vendor_name": "Schneider Electric SE" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker\u0027s choosing." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "URL Redirection to Untrusted Site" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/", "refsource": "CONFIRM", "url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2018-7804", "datePublished": "2018-12-17T22:00:00", "dateReserved": "2018-03-08T00:00:00", "dateUpdated": "2024-08-05T06:37:59.165Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-7804\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2018-12-17T22:29:00.267\",\"lastModified\":\"2024-11-21T04:12:46.023\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker\u0027s choosing.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de redirecci\u00f3n de URL a sitio no fiable en los servidores web embebidos en todos los Modicon M340, Premium, Quantum PLCs y BMXNOR0200, donde un usuario que hace clic en un enlace especialmente manipulado puede ser redirigido a una URL escogida por el atacante.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:N\",\"baseScore\":5.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicom_m340_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A53C0B78-6556-44B7-9546-75F48EDD87CB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicom_m340:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7F3D3249-CD51-496E-AB39-79D53EB318F8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicom_premium_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA79EF8E-C525-4CCB-AC21-F7493FA55BF7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicom_premium:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8BAD47C7-A8D1-44B3-9917-D5285E63F3B5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicom_quantum_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"62BAE494-82C9-4CC7-8149-37DD1ADA10F2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicom_quantum:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B17B062-016A-45C2-A640-C8FD31E6E05F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicom_bmxnor0200h_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D99FE33D-BBA0-40B7-B79C-E276BF8353FB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicom_bmxnor0200h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8C420C7F-5B35-4775-8775-241FDD0B759C\"}]}]}],\"references\":[{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…