Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2018-16417 (GCVE-0-2018-16417)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T10:24:32.103Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf" }, { "name": "108374", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/108374" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.anquanke.com/vul/id/1652568" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-10-30T16:28:13", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf" }, { "name": "108374", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/108374" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.anquanke.com/vul/id/1652568" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-16417", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt", "refsource": "CONFIRM", "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf" }, { "name": "108374", "refsource": "BID", "url": "http://www.securityfocus.com/bid/108374" }, { "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07" }, { "name": "https://www.anquanke.com/vul/id/1652568", "refsource": "MISC", "url": "https://www.anquanke.com/vul/id/1652568" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-16417", "datePublished": "2019-10-30T16:26:32", "dateReserved": "2018-09-03T00:00:00", "dateUpdated": "2024-08-05T10:24:32.103Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-16417\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2019-10-30T17:15:11.877\",\"lastModified\":\"2024-11-21T03:52:42.423\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.\"},{\"lang\":\"es\",\"value\":\"Aruba Instant versiones 4.x anteriores a la versi\u00f3n 6.4.4.8-4.2.4.12, versiones 6.5.x anteriores a la versi\u00f3n 6.5.4.11, versiones 8.3.x anteriores a 8.3.0.6 y versiones 8.4.x anteriores a la versi\u00f3n 8.4.0.1, permite una Inyecci\u00f3n de Comandos.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.0.0.0\",\"versionEndExcluding\":\"4.2.4.12\",\"matchCriteriaId\":\"EC2CC454-39A5-4D56-BB87-DF9B48303FFB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.5.0.0\",\"versionEndExcluding\":\"6.5.4.11\",\"matchCriteriaId\":\"615BA62B-7BA9-43DA-A4A8-E83F81513EC3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.3.0.0\",\"versionEndExcluding\":\"8.3.0.6\",\"matchCriteriaId\":\"B16A6954-EB81-4BB4-B612-D02415AEE765\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.4.0.0\",\"versionEndExcluding\":\"8.4.0.1\",\"matchCriteriaId\":\"715B7F25-4EFA-4BA6-995B-9E84C59116EC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:w1750d_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.4.0.1\",\"matchCriteriaId\":\"AFBFE706-F452-4018-85AE-855B971CE206\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:w1750d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9DF5733F-79FB-4EBB-AC5B-BA4B75A80AB3\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/108374\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.anquanke.com/vul/id/1652568\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/ICSA-19-134-07\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.securityfocus.com/bid/108374\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.anquanke.com/vul/id/1652568\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/ICSA-19-134-07\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
cnvd-2019-06344
Vulnerability from cnvd
Title: ALE Alcatel OmniAccess Wireless Access Point信息泄露漏洞
Description:
ALE Alcatel OmniAccess Wireless Access Point是法国ALE公司的一款无线接入点设备。
ALE Alcatel OmniAccess Wireless Access Point中存在安全漏洞。攻击者可通过发送特制的URL利用该漏洞查看配置命令。
Severity: 中
Formal description:
目前厂商暂未发布修复措施解决此安全问题,建议使用此软件的用户随时关注厂商主页或参考网址以获取解决办法: https://www.al-enterprise.com/
Reference: https://vigilance.fr/vulnerability/Alcatel-Lucent-Enterprise-OmniAccess-WLAN-Instant-multiple-vulnerabilities-28646
Name | ALE Alcatel OmniAccess Wireless Access Point |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2018-16417" } }, "description": "ALE Alcatel OmniAccess Wireless Access Point\u662f\u6cd5\u56fdALE\u516c\u53f8\u7684\u4e00\u6b3e\u65e0\u7ebf\u63a5\u5165\u70b9\u8bbe\u5907\u3002\n\nALE Alcatel OmniAccess Wireless Access Point\u4e2d\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u901a\u8fc7\u53d1\u9001\u7279\u5236\u7684URL\u5229\u7528\u8be5\u6f0f\u6d1e\u67e5\u770b\u914d\u7f6e\u547d\u4ee4\u3002", "discovererName": "unknwon", "formalWay": "\u76ee\u524d\u5382\u5546\u6682\u672a\u53d1\u5e03\u4fee\u590d\u63aa\u65bd\u89e3\u51b3\u6b64\u5b89\u5168\u95ee\u9898\uff0c\u5efa\u8bae\u4f7f\u7528\u6b64\u8f6f\u4ef6\u7684\u7528\u6237\u968f\u65f6\u5173\u6ce8\u5382\u5546\u4e3b\u9875\u6216\u53c2\u8003\u7f51\u5740\u4ee5\u83b7\u53d6\u89e3\u51b3\u529e\u6cd5\uff1a\r\nhttps://www.al-enterprise.com/", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2019-06344", "openTime": "2019-03-06", "products": { "product": "ALE Alcatel OmniAccess Wireless Access Point" }, "referenceLink": "https://vigilance.fr/vulnerability/Alcatel-Lucent-Enterprise-OmniAccess-WLAN-Instant-multiple-vulnerabilities-28646", "serverity": "\u4e2d", "submitTime": "2019-03-06", "title": "ALE Alcatel OmniAccess Wireless Access Point\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e" }
fkie_cve-2018-16417
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
arubanetworks | instant | * | |
arubanetworks | instant | * | |
arubanetworks | instant | * | |
arubanetworks | instant | * | |
siemens | w1750d_firmware | * | |
siemens | w1750d | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC2CC454-39A5-4D56-BB87-DF9B48303FFB", "versionEndExcluding": "4.2.4.12", "versionStartIncluding": "4.0.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "matchCriteriaId": "615BA62B-7BA9-43DA-A4A8-E83F81513EC3", "versionEndExcluding": "6.5.4.11", "versionStartIncluding": "6.5.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "matchCriteriaId": "B16A6954-EB81-4BB4-B612-D02415AEE765", "versionEndExcluding": "8.3.0.6", "versionStartIncluding": "8.3.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "matchCriteriaId": "715B7F25-4EFA-4BA6-995B-9E84C59116EC", "versionEndExcluding": "8.4.0.1", "versionStartIncluding": "8.4.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:w1750d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AFBFE706-F452-4018-85AE-855B971CE206", "versionEndExcluding": "8.4.0.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:w1750d:-:*:*:*:*:*:*:*", "matchCriteriaId": "9DF5733F-79FB-4EBB-AC5B-BA4B75A80AB3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection." }, { "lang": "es", "value": "Aruba Instant versiones 4.x anteriores a la versi\u00f3n 6.4.4.8-4.2.4.12, versiones 6.5.x anteriores a la versi\u00f3n 6.5.4.11, versiones 8.3.x anteriores a 8.3.0.6 y versiones 8.4.x anteriores a la versi\u00f3n 8.4.0.1, permite una Inyecci\u00f3n de Comandos." } ], "id": "CVE-2018-16417", "lastModified": "2024-11-21T03:52:42.423", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-10-30T17:15:11.877", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/108374" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://www.anquanke.com/vul/id/1652568" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt" }, { "source": "cve@mitre.org", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/108374" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.anquanke.com/vul/id/1652568" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
gsd-2018-16417
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2018-16417", "description": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.", "id": "GSD-2018-16417" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2018-16417" ], "details": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.", "id": "GSD-2018-16417", "modified": "2023-12-13T01:22:26.160032Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-16417", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt", "refsource": "CONFIRM", "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf" }, { "name": "108374", "refsource": "BID", "url": "http://www.securityfocus.com/bid/108374" }, { "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07" }, { "name": "https://www.anquanke.com/vul/id/1652568", "refsource": "MISC", "url": "https://www.anquanke.com/vul/id/1652568" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.2.4.12", "versionStartIncluding": "4.0.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.4.0.1", "versionStartIncluding": "8.4.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.3.0.6", "versionStartIncluding": "8.3.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.5.4.11", "versionStartIncluding": "6.5.0.0", "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:w1750d_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.4.0.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:w1750d:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-16417" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-77" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.anquanke.com/vul/id/1652568", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://www.anquanke.com/vul/id/1652568" }, { "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07", "refsource": "MISC", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07" }, { "name": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf" }, { "name": "108374", "refsource": "BID", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/108374" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2020-08-24T17:37Z", "publishedDate": "2019-10-30T17:15Z" } } }
var-201910-1493
Vulnerability from variot
Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection. Aruba Instant Contains an injection vulnerability.Information may be obtained. ALEAlcatelOmniAccessWirelessAccessPoint is a wireless access point device from ALE France. A security vulnerability exists in ALEAlcatelOmniAccessWirelessAccessPoint. An attacker could exploit the vulnerability to view configuration commands by sending a specially crafted URL. Siemens SCALANCE W1750D is prone to following security vulnerabilities: 1. Multiple information disclosure vulnerabilities 2. Multiple remote command injection vulnerabilities Attackers can exploit these issues to obtain sensitive information, or execute arbitrary commands or arbitrary HTML or script code in the browser of an unsuspecting user within the context of the affected application. This can allow the attacker to steal cookie-based authentication credentials and aid in further attacks. Versions prior to SCALANCE W1750D 8.4.0.1 are vulnerable
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201910-1493", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "instant", "scope": "gte", "trust": 1.0, "vendor": "arubanetworks", "version": "8.3.0.0" }, { "model": "w1750d", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "8.4.0.1" }, { "model": "instant", "scope": "gte", "trust": 1.0, "vendor": "arubanetworks", "version": "8.4.0.0" }, { "model": "instant", "scope": "lt", "trust": 1.0, "vendor": "arubanetworks", "version": "6.5.4.11" }, { "model": "instant", "scope": "lt", "trust": 1.0, "vendor": "arubanetworks", "version": "8.3.0.6" }, { "model": "instant", "scope": "lt", "trust": 1.0, "vendor": "arubanetworks", "version": "4.2.4.12" }, { "model": "instant", "scope": "gte", "trust": 1.0, "vendor": "arubanetworks", "version": "4.0.0.0" }, { "model": "instant", "scope": "lt", "trust": 1.0, "vendor": "arubanetworks", "version": "8.4.0.1" }, { "model": "instant", "scope": "gte", "trust": 1.0, "vendor": "arubanetworks", "version": "6.5.0.0" }, { "model": "instant", "scope": "lt", "trust": 0.8, "vendor": "aruba", "version": "8.4.x" }, { "model": "instant", "scope": "eq", "trust": 0.8, "vendor": "aruba", "version": "8.4.0.1" }, { "model": "instant", "scope": "eq", "trust": 0.8, "vendor": "aruba", "version": "8.3.0.6" }, { "model": "instant", "scope": "eq", "trust": 0.8, "vendor": "aruba", "version": "6.5.4.11" }, { "model": "instant", "scope": "lt", "trust": 0.8, "vendor": "aruba", "version": "8.3.x" }, { "model": "instant", "scope": "eq", "trust": 0.8, "vendor": "aruba", "version": "6.4.4.8-4.2.4.12" }, { "model": "w1750d", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "instant", "scope": "lt", "trust": 0.8, "vendor": "aruba", "version": "4.x" }, { "model": "instant", "scope": "lt", "trust": 0.8, "vendor": "aruba", "version": "6.5.x" }, { "model": "alcatel omniaccess wireless access point", "scope": null, "trust": 0.6, "vendor": "ale", "version": null }, { "model": "scalance w1750d", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance w1750d", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "8.4.0.1" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-06344" }, { "db": "BID", "id": "108374" }, { "db": "JVNDB", "id": "JVNDB-2018-016143" }, { "db": "NVD", "id": "CVE-2018-16417" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:arubanetworks:instant", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:w1750d_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-016143" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to NCCIC.", "sources": [ { "db": "CNNVD", "id": "CNNVD-201903-052" } ], "trust": 0.6 }, "cve": "CVE-2018-16417", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2018-16417", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.9, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2019-06344", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2018-16417", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2018-16417", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2018-16417", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2018-16417", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-06344", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201903-052", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2018-16417", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-06344" }, { "db": "VULMON", "id": "CVE-2018-16417" }, { "db": "JVNDB", "id": "JVNDB-2018-016143" }, { "db": "CNNVD", "id": "CNNVD-201903-052" }, { "db": "NVD", "id": "CVE-2018-16417" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection. Aruba Instant Contains an injection vulnerability.Information may be obtained. ALEAlcatelOmniAccessWirelessAccessPoint is a wireless access point device from ALE France. A security vulnerability exists in ALEAlcatelOmniAccessWirelessAccessPoint. An attacker could exploit the vulnerability to view configuration commands by sending a specially crafted URL. Siemens SCALANCE W1750D is prone to following security vulnerabilities:\n1. Multiple information disclosure vulnerabilities\n2. Multiple remote command injection vulnerabilities\nAttackers can exploit these issues to obtain sensitive information, or execute arbitrary commands or arbitrary HTML or script code in the browser of an unsuspecting user within the context of the affected application. This can allow the attacker to steal cookie-based authentication credentials and aid in further attacks. \nVersions prior to SCALANCE W1750D 8.4.0.1 are vulnerable", "sources": [ { "db": "NVD", "id": "CVE-2018-16417" }, { "db": "JVNDB", "id": "JVNDB-2018-016143" }, { "db": "CNVD", "id": "CNVD-2019-06344" }, { "db": "BID", "id": "108374" }, { "db": "VULMON", "id": "CVE-2018-16417" } ], "trust": 2.52 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-16417", "trust": 3.4 }, { "db": "ICS CERT", "id": "ICSA-19-134-07", "trust": 2.8 }, { "db": "BID", "id": "108374", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-549547", "trust": 1.7 }, { "db": "JVNDB", "id": "JVNDB-2018-016143", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2019-06344", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-19-134-02", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.1716.2", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-201903-052", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2018-16417", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-06344" }, { "db": "VULMON", "id": "CVE-2018-16417" }, { "db": "BID", "id": "108374" }, { "db": "JVNDB", "id": "JVNDB-2018-016143" }, { "db": "CNNVD", "id": "CNNVD-201903-052" }, { "db": "NVD", "id": "CVE-2018-16417" } ] }, "id": "VAR-201910-1493", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2019-06344" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-06344" } ] }, "last_update_date": "2024-11-23T21:37:16.977000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "ARUBA-PSA-2019-001", "trust": 0.8, "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt" }, { "title": "SSA-549547", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=f04f471bbc12c6e00cc683978d7f0589" } ], "sources": [ { "db": "VULMON", "id": "CVE-2018-16417" }, { "db": "JVNDB", "id": "JVNDB-2018-016143" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-74", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-016143" }, { "db": "NVD", "id": "CVE-2018-16417" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.0, "url": "http://www.securityfocus.com/bid/108374" }, { "trust": 2.5, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-134-07" }, { "trust": 1.7, "url": "https://www.anquanke.com/vul/id/1652568" }, { "trust": 1.7, "url": "https://www.arubanetworks.com/assets/alert/aruba-psa-2019-001.txt" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-16417" }, { "trust": 1.2, "url": "https://vigilance.fr/vulnerability/alcatel-lucent-enterprise-omniaccess-wlan-instant-multiple-vulnerabilities-28646" }, { "trust": 1.0, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-07" }, { "trust": 0.9, "url": "http://www.siemens.com/" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16417" }, { "trust": 0.6, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-02-0" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/80946" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-06344" }, { "db": "VULMON", "id": "CVE-2018-16417" }, { "db": "BID", "id": "108374" }, { "db": "JVNDB", "id": "JVNDB-2018-016143" }, { "db": "CNNVD", "id": "CNNVD-201903-052" }, { "db": "NVD", "id": "CVE-2018-16417" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2019-06344" }, { "db": "VULMON", "id": "CVE-2018-16417" }, { "db": "BID", "id": "108374" }, { "db": "JVNDB", "id": "JVNDB-2018-016143" }, { "db": "CNNVD", "id": "CNNVD-201903-052" }, { "db": "NVD", "id": "CVE-2018-16417" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-03-06T00:00:00", "db": "CNVD", "id": "CNVD-2019-06344" }, { "date": "2019-10-30T00:00:00", "db": "VULMON", "id": "CVE-2018-16417" }, { "date": "2019-05-14T00:00:00", "db": "BID", "id": "108374" }, { "date": "2019-11-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-016143" }, { "date": "2019-03-04T00:00:00", "db": "CNNVD", "id": "CNNVD-201903-052" }, { "date": "2019-10-30T17:15:11.877000", "db": "NVD", "id": "CVE-2018-16417" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-03-06T00:00:00", "db": "CNVD", "id": "CNVD-2019-06344" }, { "date": "2020-08-24T00:00:00", "db": "VULMON", "id": "CVE-2018-16417" }, { "date": "2019-05-14T00:00:00", "db": "BID", "id": "108374" }, { "date": "2019-11-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-016143" }, { "date": "2020-08-25T00:00:00", "db": "CNNVD", "id": "CNNVD-201903-052" }, { "date": "2024-11-21T03:52:42.423000", "db": "NVD", "id": "CVE-2018-16417" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201903-052" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Aruba Instant Injection vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-016143" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-201903-052" } ], "trust": 0.6 } }
icsa-19-134-07
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reported this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s TXT advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protectnetwork access to devices with appropriate mechanisms. In order tooperate the devices in a protected IT environment, Siemens recommends toconfigure the environment according to Siemens\u0027 operational guidelinesfor Industrial Security (Download), and to follow the recommendations inthe product manuals.", "title": "General Recommendations" }, { "category": "general", "text": "Additional information on Industrial Security by Siemens can be foundat: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions containedin Siemens\u0027 underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter \"License Terms\"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website(https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-549547: Multiple Vulnerabilites in SCALANCE W1750D", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-549547.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-19-134-07 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/refs/heads/develop/csaf_files/OT/white/2019/icsa-19-134-07.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-19-134-07 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-134-07" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "ICSA-19-134-07 Siemens SCALANCE W1750D", "tracking": { "current_release_date": "2019-05-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-134-07", "initial_release_date": "2019-05-14T00:00:00.000000Z", "revision_history": [ { "date": "2019-05-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV8.4.0.1", "product": { "name": "SCALANCE W1750D", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SCALANCE W1750D" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-7084", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A command injection vulnerability is present that permits an unauthenticated user with access to the web interface of the affected device to execute arbitrary system commands within the underlying operating system. An attacker could use this ability to copy files, read configuration, write files, delete files, or reboot the device. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality, integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7084" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109766816/" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Restrict access to the web-based management interface to the internal or", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Do not browse other websites and do not click on external links while", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Apply appropriate strategies for mitigation.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-7083", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the affected devices that allows an unauthenticated attacker to access core dumps of previously crashed processes through the web interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7083" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109766816/" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Restrict access to the web-based management interface to the internal or", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Do not browse other websites and do not click on external links while", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Apply appropriate strategies for mitigation.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-16417", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "A vulnerability is present which allows an unauthenticated user to retrieve recently cached configuration commands by sending a crafted URL to the web interface of an affected device. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-16417" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109766816/" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Restrict access to the web-based management interface to the internal or", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Do not browse other websites and do not click on external links while", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Apply appropriate strategies for mitigation.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-7082", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A command injection vulnerability is present in the affected devices that allows an authenticated administrative user to execute arbitrary commands on the underlying operating system. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no user interaction. An attacker could use the vulnerability to compromise confidentiality, integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7082" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109766816/" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Restrict access to the web-based management interface to the internal or", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Do not browse other websites and do not click on external links while", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Apply appropriate strategies for mitigation.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-7064", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that allows an attacker to trick an administrator into clicking a link which could then take administrative actions on the device or expose a session cookie for an administrative session. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise confidentiality, integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7064" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109766816/" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Restrict access to the web-based management interface to the internal or", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Do not browse other websites and do not click on external links while", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Apply appropriate strategies for mitigation.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ICSA-19-134-07
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reported this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp" } }, "lang": "en-US", "notes": [ { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s TXT advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protectnetwork access to devices with appropriate mechanisms. In order tooperate the devices in a protected IT environment, Siemens recommends toconfigure the environment according to Siemens\u0027 operational guidelinesfor Industrial Security (Download), and to follow the recommendations inthe product manuals.", "title": "General Recommendations" }, { "category": "general", "text": "Additional information on Industrial Security by Siemens can be foundat: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions containedin Siemens\u0027 underlying license terms or other applicable agreements previouslyagreed to with Siemens (hereinafter \"License Terms\"). To the extent applicableto information, software or documentation made available in or through aSiemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website(https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), inparticular Sections 8-10 of the Terms of Use, shall apply additionally. In caseof conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "coordinator", "contact_details": "central@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-549547: Multiple Vulnerabilites in SCALANCE W1750D", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-549547.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-19-134-07 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/refs/heads/develop/csaf_files/OT/white/2019/icsa-19-134-07.json" }, { "category": "self", "summary": "ICSA Advisory ICSA-19-134-07 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-134-07" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "ICSA-19-134-07 Siemens SCALANCE W1750D", "tracking": { "current_release_date": "2019-05-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-19-134-07", "initial_release_date": "2019-05-14T00:00:00.000000Z", "revision_history": [ { "date": "2019-05-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV8.4.0.1", "product": { "name": "SCALANCE W1750D", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SCALANCE W1750D" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2018-7084", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A command injection vulnerability is present that permits an unauthenticated user with access to the web interface of the affected device to execute arbitrary system commands within the underlying operating system. An attacker could use this ability to copy files, read configuration, write files, delete files, or reboot the device. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality, integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7084" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109766816/" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Restrict access to the web-based management interface to the internal or", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Do not browse other websites and do not click on external links while", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Apply appropriate strategies for mitigation.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-7083", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the affected devices that allows an unauthenticated attacker to access core dumps of previously crashed processes through the web interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7083" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109766816/" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Restrict access to the web-based management interface to the internal or", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Do not browse other websites and do not click on external links while", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Apply appropriate strategies for mitigation.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-16417", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "A vulnerability is present which allows an unauthenticated user to retrieve recently cached configuration commands by sending a crafted URL to the web interface of an affected device. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-16417" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109766816/" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Restrict access to the web-based management interface to the internal or", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Do not browse other websites and do not click on external links while", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Apply appropriate strategies for mitigation.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-7082", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "A command injection vulnerability is present in the affected devices that allows an authenticated administrative user to execute arbitrary commands on the underlying operating system. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no user interaction. An attacker could use the vulnerability to compromise confidentiality, integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7082" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109766816/" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Restrict access to the web-based management interface to the internal or", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Do not browse other websites and do not click on external links while", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Apply appropriate strategies for mitigation.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2018-7064", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that allows an attacker to trick an administrator into clicking a link which could then take administrative actions on the device or expose a session cookie for an administrative session. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise confidentiality, integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7064" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L/E:P/RL:O/RC:C" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/us/en/view/109766816/" }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Restrict access to the web-based management interface to the internal or", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Do not browse other websites and do not click on external links while", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Siemens has identified the following specific workarounds and mitigations thatcustomers can apply to reduce the risk:VPN network.being authenticated to the administrative web interface. Apply appropriate strategies for mitigation.", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L/E:P/RL:O/RC:C", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
ghsa-cx84-r7h4-7pfj
Vulnerability from github
Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.
{ "affected": [], "aliases": [ "CVE-2018-16417" ], "database_specific": { "cwe_ids": [ "CWE-77" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2019-10-30T17:15:00Z", "severity": "HIGH" }, "details": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.", "id": "GHSA-cx84-r7h4-7pfj", "modified": "2024-04-04T02:36:26Z", "published": "2022-05-24T17:00:06Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-16417" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf" }, { "type": "WEB", "url": "https://www.anquanke.com/vul/id/1652568" }, { "type": "WEB", "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt" }, { "type": "WEB", "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/108374" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "type": "CVSS_V3" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.