CVE-2017-7965 (GCVE-0-2017-7965)
Vulnerability from cvelistv5
Published
2017-06-07 19:00
Modified
2024-08-05 16:19
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Buffer Overflow
Summary
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.
References
| URL | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric SE | SoMachine HVAC Programming Software |
Version: v2.1.0 for Modicon M171/M172 Controllers |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:19:29.459Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
},
{
"name": "98449",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98449"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SoMachine HVAC Programming Software",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "v2.1.0 for Modicon M171/M172 Controllers"
}
]
}
],
"datePublic": "2017-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Buffer Overflow",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-06-08T09:57:01",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
},
{
"name": "98449",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98449"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2017-7965",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine HVAC Programming Software",
"version": {
"version_data": [
{
"version_value": "v2.1.0 for Modicon M171/M172 Controllers"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
},
{
"name": "98449",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/98449"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2017-7965",
"datePublished": "2017-06-07T19:00:00",
"dateReserved": "2017-04-19T00:00:00",
"dateUpdated": "2024-08-05T16:19:29.459Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2017-7965\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2017-06-07T19:29:00.197\",\"lastModified\":\"2025-04-20T01:37:25.860\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de desbordamiento de b\u00fafer en el ejecutable del Software de Programaci\u00f3n AlTracePrint.exe, en SoMachine HVAC versi\u00f3n v2.1.0 de Schneider Electric para el controlador Modicon M171/M172.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.3,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:somachine_hvac:2.1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0F523B8A-A5DE-40F0-9D17-4DB519107368\"}]}]}],\"references\":[{\"url\":\"http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/98449\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/98449\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…