CVE-2017-6038 (GCVE-0-2017-6038)
Vulnerability from cvelistv5
Published
2017-06-30 02:35
Modified
2024-08-05 15:18
Severity ?
CWE
Summary
A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web application does not sufficiently verify that requests were provided by the user who submitted the request.
References
ics-cert@hq.dhs.gov https://ics-cert.us-cert.gov/advisories/ICSA-17-026-02A Mitigation, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108 https://ics-cert.us-cert.gov/advisories/ICSA-17-026-02A Mitigation, Third Party Advisory, US Government Resource
Impacted products
Vendor Product Version
n/a Belden Hirschmann GECKO Version: Belden Hirschmann GECKO
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.614Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-026-02A"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Belden Hirschmann GECKO",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Belden Hirschmann GECKO"
            }
          ]
        }
      ],
      "datePublic": "2017-06-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web application does not sufficiently verify that requests were provided by the user who submitted the request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-06-30T02:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-026-02A"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6038",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Belden Hirschmann GECKO",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Belden Hirschmann GECKO"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web application does not sufficiently verify that requests were provided by the user who submitted the request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-352"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-026-02A",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-026-02A"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6038",
    "datePublished": "2017-06-30T02:35:00",
    "dateReserved": "2017-02-16T00:00:00",
    "dateUpdated": "2024-08-05T15:18:49.614Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-6038\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2017-06-30T03:29:00.500\",\"lastModified\":\"2025-04-20T01:37:25.860\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web application does not sufficiently verify that requests were provided by the user who submitted the request.\"},{\"lang\":\"es\",\"value\":\"Se ha descubierto un problema de Cross-Site Request Forgery (CSRF) en el switch Belden Hirschmann GECKO Lite Managed, en versiones 2.0.00 y anteriores. La aplicaci\u00f3n web no verifica lo suficiente que las peticiones fuesen proporcionadas por el usuario que envi\u00f3 la solicitud.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:L\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":4.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:P\",\"baseScore\":5.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:belden_hirschmann:gecko_lite_managed_switch_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.0.00\",\"matchCriteriaId\":\"F6C3FE20-F449-4AE3-A70D-125BE0934473\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:belden_hirschmann:gecko_lite_managed_switch:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F981F2D-B30E-49A8-9FFB-5A9A01C6D46C\"}]}]}],\"references\":[{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-026-02A\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-026-02A\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…