CVE-2017-6030 (GCVE-0-2017-6030)
Vulnerability from cvelistv5 – Published: 2017-06-30 02:35 – Updated: 2026-06-04 21:40
VLAI
Title
Schneider Electric Modicon PLCs Predictable Value Range from Previous Values
Summary
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02 | x_refsource_MISC |
| http://www.securityfocus.com/bid/97254 | vdb-entryx_refsource_BID |
| https://github.com/cisagov/CSAF/blob/develop/csaf… |
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Modicon M221 |
Affected:
0 , < 1.5.0.0
(custom)
|
|
| Schneider Electric | Modicon M241 |
Affected:
0 , < 4.0.5.11
(custom)
|
|
| Schneider Electric | Modicon M251 |
Affected:
0 , < 4.0.5.11
(custom)
|
Date Public
2017-06-29 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:18:49.582Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
},
{
"name": "97254",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/97254"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2017-6030",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T13:20:18.684514Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T13:22:59.394Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M221",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "1.5.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M241",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.0.5.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M251",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "4.0.5.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "David Formby and Raheem Beyah of Georgia Tech and Fortiphyd Logic, Inc. reported the identified vulnerabilities."
}
],
"datePublic": "2017-06-29T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.\u003c/p\u003e"
}
],
"value": "A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-343",
"description": "CWE-343",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-04T21:40:02.867Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
},
{
"name": "97254",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/97254"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2017/icsa-17-089-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSchneider Electric has released new firmware versions to address the predictable value range from previous values vulnerability and the use of insufficiently random values vulnerability, which are available through Schneider Electric\u2019s software update tool, SoMachine, Version 4.2, and SoMachineBasic, Version 1.5. Schneider Electric has not released a product to address the insufficiently protected credentials vulnerability; however, Schneider Electric has provided compensating controls to reduce the risk of exploitation.\u003c/p\u003e\u003cp\u003eSoMachineBasic, Version 1.5, is available at the following location:\u003c/p\u003e\u003cp\u003ehttp://www.schneider-electric.fr/fr/download/document/SOMBASAP15SOFT/\u0026nbsp;\u003c/p\u003e\u003cp\u003eSchneider Electric has provided the following compensating controls to reduce the risk of exploitation of the insufficiently protected credentials vulnerability:\u003c/p\u003e\u003cul\u003e\u003cli\u003eVerify that the hardware and software infrastructure that the PLCs are integrated into (along with all organizational measures and rules covering access to the infrastructure) consider the results of the hazard and risk analysis, and are implemented according to best practices and standards such as ISA/IEC 62443.\u003c/li\u003e\u003cli\u003eLimit traffic on the local network with managed switches\u003c/li\u003e\u003cli\u003eWhere possible, avoid using Wi-Fi networks, but when Wi-Fi is essential, use only secure communications (such as WPA2 encryption)\u003c/li\u003e\u003cli\u003eDo not grant [network] access to unknown computers\u003c/li\u003e\u003cli\u003eWhen remote access is essential, use secure methods such as Virtual Private Networks (VPNs), and ensure the remote access solution(s), as well as the remote computer(s) are kept up-to-date with the latest security patches.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eSchneider Electric has released Security Notifications SEVD-2017-075-01, SEVD-2017-075-02, and SEVD-2017-075-03, which provide additional information about the identified vulnerabilities, mitigations, and compensating controls:\u003c/p\u003e\u003cp\u003e\u003ca href=\"http://www.schneider-electric.com/en/download/document/SEVD-2017-075-01/\"\u003ehttp://www.schneider-electric.com/en/download/document/SEVD-2017-075-01/\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\u003ca href=\"http://www.schneider-electric.com/en/download/document/SEVD-2017-075-02/\"\u003ehttp://www.schneider-electric.com/en/download/document/SEVD-2017-075-02/\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\u003ca href=\"http://www.schneider-electric.com/en/download/document/SEVD-2017-075-03/\"\u003ehttp://www.schneider-electric.com/en/download/document/SEVD-2017-075-03/\u003c/a\u003e\u003c/p\u003e"
}
],
"value": "Schneider Electric has released new firmware versions to address the predictable value range from previous values vulnerability and the use of insufficiently random values vulnerability, which are available through Schneider Electric\u2019s software update tool, SoMachine, Version 4.2, and SoMachineBasic, Version 1.5. Schneider Electric has not released a product to address the insufficiently protected credentials vulnerability; however, Schneider Electric has provided compensating controls to reduce the risk of exploitation.\n\n\n\nSoMachineBasic, Version 1.5, is available at the following location:\n\n\n\nhttp://www.schneider-electric.fr/fr/download/document/SOMBASAP15SOFT/\u00a0\n\n\n\nSchneider Electric has provided the following compensating controls to reduce the risk of exploitation of the insufficiently protected credentials vulnerability:\n\n * Verify that the hardware and software infrastructure that the PLCs are integrated into (along with all organizational measures and rules covering access to the infrastructure) consider the results of the hazard and risk analysis, and are implemented according to best practices and standards such as ISA/IEC 62443.\n * Limit traffic on the local network with managed switches\n * Where possible, avoid using Wi-Fi networks, but when Wi-Fi is essential, use only secure communications (such as WPA2 encryption)\n * Do not grant [network] access to unknown computers\n * When remote access is essential, use secure methods such as Virtual Private Networks (VPNs), and ensure the remote access solution(s), as well as the remote computer(s) are kept up-to-date with the latest security patches.\n\n\n\n\nSchneider Electric has released Security Notifications SEVD-2017-075-01, SEVD-2017-075-02, and SEVD-2017-075-03, which provide additional information about the identified vulnerabilities, mitigations, and compensating controls:\n\n\n\n http://www.schneider-electric.com/en/download/document/SEVD-2017-075-01/ \n\n\n\n http://www.schneider-electric.com/en/download/document/SEVD-2017-075-02/ \n\n\n\n http://www.schneider-electric.com/en/download/document/SEVD-2017-075-03/"
}
],
"source": {
"advisory": "ICSA-17-089-02",
"discovery": "EXTERNAL"
},
"title": "Schneider Electric Modicon PLCs Predictable Value Range from Previous Values",
"x_generator": {
"engine": "Vulnogram 1.0.2"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-6030",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Schneider Electric Modicon PLCs",
"version": {
"version_data": [
{
"version_value": "Schneider Electric Modicon PLCs"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-343"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02"
},
{
"name": "97254",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/97254"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-6030",
"datePublished": "2017-06-30T02:35:00.000Z",
"dateReserved": "2017-02-16T00:00:00.000Z",
"dateUpdated": "2026-06-04T21:40:02.867Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2017-6030",
"date": "2026-06-05",
"epss": "0.00528",
"percentile": "0.67531"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"4.0.3.20\", \"matchCriteriaId\": \"9CA3FF3A-9145-4DAD-BAD6-D55C97E182AA\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4D8FD9D9-F59F-470E-9F7F-CDDD80B0633C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"4.0.3.20\", \"matchCriteriaId\": \"6FDB0710-FB7F-4346-9EEC-4C75ECEA0A1E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B8E03A25-B0B6-4BA2-80BC-52C16A6837E0\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m221_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.1.1.5\", \"matchCriteriaId\": \"68FB877A-87E1-4DE9-B758-8CEA1BE1456F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BB0D83F4-B718-47AB-AFB8-B576CB138AAC\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.\"}, {\"lang\": \"es\", \"value\": \"Un problema de Rango de Valor Predecible de Valores Anteriores fue detectado en PLCs Modicon M221, versiones de firmware anteriores a 1.5.0.0, Modicon M241, versiones de firmware anteriores a la 4.0.5.11, y Modicon M251, versiones de firmware anteriores a la 4.0.5.11 de Schneider Electric. Los productos afectados generan n\\u00fameros de secuencia inicial TCP de aleatoriedad insuficientemente que pueden permitir a un atacante predecir los n\\u00fameros de los valores anteriores. Esto puede permitir a un atacante suplantar o interrumpir las conexiones TCP.\"}]",
"id": "CVE-2017-6030",
"lastModified": "2024-11-21T03:28:56.400",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 2.5}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:P/A:P\", \"baseScore\": 6.4, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 4.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2017-06-30T03:29:00.390",
"references": "[{\"url\": \"http://www.securityfocus.com/bid/97254\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://www.securityfocus.com/bid/97254\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-343\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-331\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2017-6030\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2017-06-30T03:29:00.390\",\"lastModified\":\"2026-06-04T22:16:50.067\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.\"},{\"lang\":\"es\",\"value\":\"Un problema de Rango de Valor Predecible de Valores Anteriores fue detectado en PLCs Modicon M221, versiones de firmware anteriores a 1.5.0.0, Modicon M241, versiones de firmware anteriores a la 4.0.5.11, y Modicon M251, versiones de firmware anteriores a la 4.0.5.11 de Schneider Electric. Los productos afectados generan n\u00fameros de secuencia inicial TCP de aleatoriedad insuficientemente que pueden permitir a un atacante predecir los n\u00fameros de los valores anteriores. Esto puede permitir a un atacante suplantar o interrumpir las conexiones TCP.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":2.5},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":2.5}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:P/A:P\",\"baseScore\":6.4,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-343\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-331\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0.3.20\",\"matchCriteriaId\":\"9CA3FF3A-9145-4DAD-BAD6-D55C97E182AA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D8FD9D9-F59F-470E-9F7F-CDDD80B0633C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.0.3.20\",\"matchCriteriaId\":\"6FDB0710-FB7F-4346-9EEC-4C75ECEA0A1E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B8E03A25-B0B6-4BA2-80BC-52C16A6837E0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m221_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.1.1.5\",\"matchCriteriaId\":\"68FB877A-87E1-4DE9-B758-8CEA1BE1456F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB0D83F4-B718-47AB-AFB8-B576CB138AAC\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/97254\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2017/icsa-17-089-02.json\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.securityfocus.com/bid/97254\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"http://www.securityfocus.com/bid/97254\", \"name\": \"97254\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-05T15:18:49.582Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2017-6030\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-05-29T13:20:18.684514Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-05-29T13:21:39.732Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"Schneider Electric Modicon PLCs\", \"versions\": [{\"status\": \"affected\", \"version\": \"Schneider Electric Modicon PLCs\"}]}], \"datePublic\": \"2017-06-29T00:00:00.000Z\", \"references\": [{\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"http://www.securityfocus.com/bid/97254\", \"name\": \"97254\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-343\", \"description\": \"CWE-343\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2017-06-30T09:57:01.000Z\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"Schneider Electric Modicon PLCs\"}]}, \"product_name\": \"Schneider Electric Modicon PLCs\"}]}, \"vendor_name\": \"n/a\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02\", \"name\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-089-02\", \"refsource\": \"MISC\"}, {\"url\": \"http://www.securityfocus.com/bid/97254\", \"name\": \"97254\", \"refsource\": \"BID\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-343\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2017-6030\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"ics-cert@hq.dhs.gov\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2017-6030\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-05-29T13:22:59.394Z\", \"dateReserved\": \"2017-02-16T00:00:00.000Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2017-06-30T02:35:00.000Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…