CVE-2017-3223 (GCVE-0-2017-3223)
Vulnerability from cvelistv5
Published
2018-07-24 15:00
Modified
2024-08-05 14:16
Severity ?
CWE
Summary
Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow. Dahua IP camera products include an application known as Sonia (/usr/bin/sonia) that provides the web interface and other services for controlling the IP camera remotely. Versions of Sonia included in firmware versions prior to DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621 do not validate input data length for the 'password' field of the web interface. A remote, unauthenticated attacker may submit a crafted POST request to the IP camera's Sonia web interface that may lead to out-of-bounds memory operations and loss of availability or remote code execution. The issue was originally identified by the researcher in firmware version DH_IPC-HX1X2X-Themis_EngSpnFrn_N_V2.400.0000.30.R.20160803.
References
Impacted products
Vendor Product Version
Dahua IP Camera Version: DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621   < DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:16:28.415Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VU#547255",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "https://www.kb.cert.org/vuls/id/547255"
          },
          {
            "name": "99620",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99620"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IP Camera",
          "vendor": "Dahua",
          "versions": [
            {
              "lessThan": "DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621",
              "status": "affected",
              "version": "DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Thanks to Ilya Smith of Positive Technologies for reporting this vulnerability."
        }
      ],
      "datePublic": "2017-07-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow. Dahua IP camera products include an application known as Sonia (/usr/bin/sonia) that provides the web interface and other services for controlling the IP camera remotely. Versions of Sonia included in firmware versions prior to DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621 do not validate input data length for the \u0027password\u0027 field of the web interface. A remote, unauthenticated attacker may submit a crafted POST request to the IP camera\u0027s Sonia web interface that may lead to out-of-bounds memory operations and loss of availability or remote code execution. The issue was originally identified by the researcher in firmware version DH_IPC-HX1X2X-Themis_EngSpnFrn_N_V2.400.0000.30.R.20160803."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-07-25T09:57:01",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "name": "VU#547255",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "https://www.kb.cert.org/vuls/id/547255"
        },
        {
          "name": "99620",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99620"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Dahua has released firmware version DH_IPC-ACK-Themis_Eng_P_V2.400.0000.14.R.20170713.bin to address this issue"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2017-3223",
          "STATE": "PUBLIC",
          "TITLE": "Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IP Camera",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621",
                            "version_value": "DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dahua"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Thanks to Ilya Smith of Positive Technologies for reporting this vulnerability."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow. Dahua IP camera products include an application known as Sonia (/usr/bin/sonia) that provides the web interface and other services for controlling the IP camera remotely. Versions of Sonia included in firmware versions prior to DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621 do not validate input data length for the \u0027password\u0027 field of the web interface. A remote, unauthenticated attacker may submit a crafted POST request to the IP camera\u0027s Sonia web interface that may lead to out-of-bounds memory operations and loss of availability or remote code execution. The issue was originally identified by the researcher in firmware version DH_IPC-HX1X2X-Themis_EngSpnFrn_N_V2.400.0000.30.R.20160803."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "VU#547255",
              "refsource": "CERT-VN",
              "url": "https://www.kb.cert.org/vuls/id/547255"
            },
            {
              "name": "99620",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99620"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Dahua has released firmware version DH_IPC-ACK-Themis_Eng_P_V2.400.0000.14.R.20170713.bin to address this issue"
          }
        ],
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2017-3223",
    "datePublished": "2018-07-24T15:00:00",
    "dateReserved": "2016-12-05T00:00:00",
    "dateUpdated": "2024-08-05T14:16:28.415Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-3223\",\"sourceIdentifier\":\"cret@cert.org\",\"published\":\"2018-07-24T15:29:00.843\",\"lastModified\":\"2024-11-21T03:25:04.217\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dahua IP camera products using firmware versions prior to V2.400.0000.14.R.20170713 include a version of the Sonia web interface that may be vulnerable to a stack buffer overflow. Dahua IP camera products include an application known as Sonia (/usr/bin/sonia) that provides the web interface and other services for controlling the IP camera remotely. Versions of Sonia included in firmware versions prior to DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621 do not validate input data length for the \u0027password\u0027 field of the web interface. A remote, unauthenticated attacker may submit a crafted POST request to the IP camera\u0027s Sonia web interface that may lead to out-of-bounds memory operations and loss of availability or remote code execution. The issue was originally identified by the researcher in firmware version DH_IPC-HX1X2X-Themis_EngSpnFrn_N_V2.400.0000.30.R.20160803.\"},{\"lang\":\"es\",\"value\":\"Los productos de c\u00e1maras Dahua IP que emplean versiones de firmware anteriores a la V2.400.0000.14.R.20170713 incluyen una versi\u00f3n de la interfaz web de Sonia que podr\u00eda ser vulnerable a un desbordamiento de b\u00fafer basado en pila. Los productos de c\u00e1maras Dahua IP incluyen una aplicaci\u00f3n conocida como Sonia (/usr/bin/sonia) que proporciona la interfaz web y otros servicios para controlar de forma remota la c\u00e1mara IP. Las versiones de Sonia incluidas en las versiones de firmware anteriores a DH_IPC-Consumer-Zi-Themis_Eng_P_V2.408.0000.11.R.20170621 no validan la longitud de los datos de entrada para el campo \\\"password\\\" de la interfaz web. Un atacante remoto no autenticado podr\u00eda enviar una petici\u00f3n POST manipulada a la interfaz web Sonia de las c\u00e1maras IP que podr\u00eda conducir a operaciones de memoria fuera de l\u00edmites y a la p\u00e9rdida de disponibilidad o a la ejecuci\u00f3n remota de c\u00f3digo. El problema fue identificado originariamente por el investigador en la versi\u00f3n de firmware DH_IPC-HX1X2X-Themis_EngSpnFrn_N_V2.400.0000.30.R.20160803.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cret@cert.org\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dahuasecurity:ip_camera_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"dh_ipc-ack-themis_eng_p_v2.400.0000.14.r.20170713.bin\",\"matchCriteriaId\":\"43A5DA4C-934D-4C9B-8246-8E729219D552\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dahuasecurity:ip_camera:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3C1DB735-F54C-4E47-BC00-C246E4C5911B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dahuasecurity:ip_camera_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.400.0000.14.r.20170713\",\"matchCriteriaId\":\"82BABFE4-CA54-432F-A91A-B09CDE3C5AB8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dahuasecurity:ip_camera:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3C1DB735-F54C-4E47-BC00-C246E4C5911B\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/99620\",\"source\":\"cret@cert.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.kb.cert.org/vuls/id/547255\",\"source\":\"cret@cert.org\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.securityfocus.com/bid/99620\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.kb.cert.org/vuls/id/547255\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…