CVE-2015-1007 (GCVE-0-2015-1007)
Vulnerability from cvelistv5
Published
2019-03-25 18:38
Modified
2024-08-06 04:26
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based buffer overflow
Summary
A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible.
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Opto 22 | PAC Project Professional |
Version: < R9.4008 |
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T04:26:11.562Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-120-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PAC Project Professional",
"vendor": "Opto 22",
"versions": [
{
"status": "affected",
"version": "\u003c R9.4008"
}
]
},
{
"product": "PAC Project Basic",
"vendor": "Opto 22",
"versions": [
{
"status": "affected",
"version": "\u003c R9.4008"
}
]
},
{
"product": "PAC Display Basic",
"vendor": "Opto 22",
"versions": [
{
"status": "affected",
"version": "\u003c R9.4g"
}
]
},
{
"product": "PAC Display Professional",
"vendor": "Opto 22",
"versions": [
{
"status": "affected",
"version": "\u003c R9.4g"
}
]
},
{
"product": "OptoOPCServer",
"vendor": "Opto 22",
"versions": [
{
"status": "affected",
"version": "R9.4c and prior that were installed by PAC Project installer versions prior to R9.4008"
}
]
},
{
"product": "OptoDataLink",
"vendor": "Opto 22",
"versions": [
{
"status": "affected",
"version": "R9.4d and prior that were installed by PAC Project installer versions prior to R9.4008"
}
]
}
],
"datePublic": "2015-04-30T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based buffer overflow CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-03-25T18:38:25",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-120-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2015-1007",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PAC Project Professional",
"version": {
"version_data": [
{
"version_value": "\u003c R9.4008"
}
]
}
},
{
"product_name": "PAC Project Basic",
"version": {
"version_data": [
{
"version_value": "\u003c R9.4008"
}
]
}
},
{
"product_name": "PAC Display Basic",
"version": {
"version_data": [
{
"version_value": "\u003c R9.4g"
}
]
}
},
{
"product_name": "PAC Display Professional",
"version": {
"version_data": [
{
"version_value": "\u003c R9.4g"
}
]
}
},
{
"product_name": "OptoOPCServer",
"version": {
"version_data": [
{
"version_value": "R9.4c and prior that were installed by PAC Project installer versions prior to R9.4008"
}
]
}
},
{
"product_name": "OptoDataLink",
"version": {
"version_data": [
{
"version_value": "R9.4d and prior that were installed by PAC Project installer versions prior to R9.4008"
}
]
}
}
]
},
"vendor_name": "Opto 22"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Stack-based buffer overflow CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-120-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-120-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2015-1007",
"datePublished": "2019-03-25T18:38:25",
"dateReserved": "2015-01-10T00:00:00",
"dateUpdated": "2024-08-06T04:26:11.562Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2015-1007\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2019-03-25T19:29:00.243\",\"lastModified\":\"2024-11-21T02:24:28.883\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible.\"},{\"lang\":\"es\",\"value\":\"Un archivo de configuraci\u00f3n especialmente manipulado podr\u00eda ser utilizado para provocar un desbordamiento de b\u00fafer basado en pila en el OPCTest.exe, lo cual podr\u00eda permitir la ejecuci\u00f3n remota de c\u00f3digo en Opto 22 PAC Project Professional, en versiones anteriores a la R9.4008, PAC Project Basic en versiones anteriores a la R9.4008, PAC Display Basic en versiones anteriores a la R9.4g, PAC Display Professional en versiones anteriores a la R9.4g y OptoOPCServer en su versi\u00f3n R9.4c y anteriores, que fueron instaladas por PAC Project installer, en versiones anteriores a la R9.4008, y en OptoDataLink en su versi\u00f3n R9.4d y anteriores, que fueron instaladas por PAC Project installer, en versiones anteriores a la R9.4008. Opto 22 recomienda que se actualice el producto a la versi\u00f3n m\u00e1s reciente cuanto antes.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opto22:optodatalink:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"r9.4d\",\"matchCriteriaId\":\"3A839A0F-A9C2-4F2A-87F0-19BEB6E3F561\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opto22:optoopcserver:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"r9.4c\",\"matchCriteriaId\":\"BE3E7161-4D6B-419D-BF56-B8A9C0796D83\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opto22:pac_display:*:*:*:*:basic:*:*:*\",\"versionEndExcluding\":\"r9.4g\",\"matchCriteriaId\":\"393DE6C4-A6AE-4AF9-8555-F8A4DF2028CC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opto22:pac_display:*:*:*:*:professional:*:*:*\",\"versionEndExcluding\":\"r9.4g\",\"matchCriteriaId\":\"9F38A3B6-F010-4A6B-ABD0-AA3E77C31CD9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opto22:pac_project:*:*:*:*:basic:*:*:*\",\"versionEndExcluding\":\"r9.4008\",\"matchCriteriaId\":\"042A1505-4EF3-4CFA-9187-EFB4CCB6A0FA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opto22:pac_project:*:*:*:*:professional:*:*:*\",\"versionEndExcluding\":\"r9.4008\",\"matchCriteriaId\":\"A0AC2D7E-D720-4299-BE1D-7EE45709A226\"}]}]}],\"references\":[{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-15-120-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-15-120-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…