cve-2014-4683
Vulnerability from cvelistv5
Published
2014-07-24 14:00
Modified
2024-08-06 11:27
Severity ?
Summary
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-06T11:27:35.268Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_refsource_CONFIRM",
                     "x_transferred",
                  ],
                  url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         datePublic: "2014-07-23T00:00:00",
         descriptions: [
            {
               lang: "en",
               value: "The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2014-07-24T14:57:01",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               tags: [
                  "x_refsource_CONFIRM",
               ],
               url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf",
            },
         ],
         x_legacyV4Record: {
            CVE_data_meta: {
               ASSIGNER: "cve@mitre.org",
               ID: "CVE-2014-4683",
               STATE: "PUBLIC",
            },
            affects: {
               vendor: {
                  vendor_data: [
                     {
                        product: {
                           product_data: [
                              {
                                 product_name: "n/a",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "n/a",
                                       },
                                    ],
                                 },
                              },
                           ],
                        },
                        vendor_name: "n/a",
                     },
                  ],
               },
            },
            data_format: "MITRE",
            data_type: "CVE",
            data_version: "4.0",
            description: {
               description_data: [
                  {
                     lang: "eng",
                     value: "The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.",
                  },
               ],
            },
            problemtype: {
               problemtype_data: [
                  {
                     description: [
                        {
                           lang: "eng",
                           value: "n/a",
                        },
                     ],
                  },
               ],
            },
            references: {
               reference_data: [
                  {
                     name: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf",
                     refsource: "CONFIRM",
                     url: "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf",
                  },
               ],
            },
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2014-4683",
      datePublished: "2014-07-24T14:00:00",
      dateReserved: "2014-06-28T00:00:00",
      dateUpdated: "2024-08-06T11:27:35.268Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      nvd: "{\"cve\":{\"id\":\"CVE-2014-4683\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2014-07-24T14:55:08.050\",\"lastModified\":\"2025-04-12T10:46:40.837\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.\"},{\"lang\":\"es\",\"value\":\"El servidor WebNavigator en Siemens SIMATIC WinCC anterior a 7.3, utilizado en PCS7 y otros productos, permite a usuarios remotos autenticados ganar privilegios a través de una solicitud (1) HTTP o (2) HTTPS.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:P/I:P/A:N\",\"baseScore\":4.9,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.8,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-264\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:*:sp1:*:*:*:*:*:*\",\"versionEndIncluding\":\"8.0\",\"matchCriteriaId\":\"0165209F-7378-4C05-9373-ECA6EA57697D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"33FA164B-E269-4140-AC85-2623356AF636\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8B894F4-9635-4436-BC0A-E43280426017\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.2\",\"matchCriteriaId\":\"74484B5D-121B-4838-9072-019532E78A03\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4CB277F-7ECB-4F44-8BB5-A3D350486EE7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"616535F1-F609-408B-AE48-61ACF48748A1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7F322FCB-32F4-4C5A-A7F5-F7EF41188C88\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"69822DB4-DC79-4F88-A470-5AC512C77377\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"996DE8BD-DD51-41EF-9882-C2BD2CC5FE53\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*\",\"matchCriteriaId\":\"945C8B46-4CDA-4143-889C-30E30E93DB29\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A33F9015-7058-419A-8762-CB2AE4ACF1A7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6271FCC-CCF6-4D31-801A-B4B0DC4639DD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF7A6B2B-D573-4285-B3B4-136F2BE7E710\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"111D0F4D-2B67-46E8-BF8D-5D30EFE561EE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2B16BB99-49E0-443E-BEE0-C7694D2C54E1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.1:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"A4115260-50FC-40C9-81CF-4D9F97394627\"}]}]}],\"references\":[{\"url\":\"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
   },
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.