CVE-2013-4709 (GCVE-0-2013-4709)
Vulnerability from cvelistv5
Published
2013-09-20 15:00
Modified
2024-09-16 17:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Buffer overflow in the PPP Access Concentrator (PPPAC) on the SEIL/x86 with firmware before 2.82, SEIL/X1 with firmware before 4.32, SEIL/X2 with firmware before 4.32, SEIL/B1 with firmware before 4.32, SEIL/Turbo with firmware before 2.16, and SEIL/neu 2FE Plus with firmware before 2.16 allows remote attackers to execute arbitrary code via a crafted L2TP message.
References
| URL | Tags | ||
|---|---|---|---|
|
|
|||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:27.122Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "JVN#43152129",
"tags": [
"third-party-advisory",
"x_refsource_JVN",
"x_transferred"
],
"url": "http://jvn.jp/en/jp/JVN43152129/index.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.seil.jp/support/security/a01396.html"
},
{
"name": "JVNDB-2013-000092",
"tags": [
"third-party-advisory",
"x_refsource_JVNDB",
"x_transferred"
],
"url": "http://jvndb.jvn.jp/jvndb/JVNDB-2013-000092"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in the PPP Access Concentrator (PPPAC) on the SEIL/x86 with firmware before 2.82, SEIL/X1 with firmware before 4.32, SEIL/X2 with firmware before 4.32, SEIL/B1 with firmware before 4.32, SEIL/Turbo with firmware before 2.16, and SEIL/neu 2FE Plus with firmware before 2.16 allows remote attackers to execute arbitrary code via a crafted L2TP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-09-20T15:00:00Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"name": "JVN#43152129",
"tags": [
"third-party-advisory",
"x_refsource_JVN"
],
"url": "http://jvn.jp/en/jp/JVN43152129/index.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.seil.jp/support/security/a01396.html"
},
{
"name": "JVNDB-2013-000092",
"tags": [
"third-party-advisory",
"x_refsource_JVNDB"
],
"url": "http://jvndb.jvn.jp/jvndb/JVNDB-2013-000092"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vultures@jpcert.or.jp",
"ID": "CVE-2013-4709",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in the PPP Access Concentrator (PPPAC) on the SEIL/x86 with firmware before 2.82, SEIL/X1 with firmware before 4.32, SEIL/X2 with firmware before 4.32, SEIL/B1 with firmware before 4.32, SEIL/Turbo with firmware before 2.16, and SEIL/neu 2FE Plus with firmware before 2.16 allows remote attackers to execute arbitrary code via a crafted L2TP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "JVN#43152129",
"refsource": "JVN",
"url": "http://jvn.jp/en/jp/JVN43152129/index.html"
},
{
"name": "http://www.seil.jp/support/security/a01396.html",
"refsource": "CONFIRM",
"url": "http://www.seil.jp/support/security/a01396.html"
},
{
"name": "JVNDB-2013-000092",
"refsource": "JVNDB",
"url": "http://jvndb.jvn.jp/jvndb/JVNDB-2013-000092"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2013-4709",
"datePublished": "2013-09-20T15:00:00Z",
"dateReserved": "2013-06-26T00:00:00Z",
"dateUpdated": "2024-09-16T17:58:50.809Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2013-4709\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2013-09-20T15:26:04.230\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Buffer overflow in the PPP Access Concentrator (PPPAC) on the SEIL/x86 with firmware before 2.82, SEIL/X1 with firmware before 4.32, SEIL/X2 with firmware before 4.32, SEIL/B1 with firmware before 4.32, SEIL/Turbo with firmware before 2.16, and SEIL/neu 2FE Plus with firmware before 2.16 allows remote attackers to execute arbitrary code via a crafted L2TP message.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de buffer en PPP Access Concentrator (PPPAC) en SEIL/x86 con firmware anterior a 2.82, SEIL/X1 con firmware anterior a 4.32, SEIL/X2 con firmware anterior a 4.32, SEIL/B1 con firmware anterior a 4.32, SEIL/Turbo con firmware anterior a 2.16, y SEIL/neu 2FE Plus con firmware anterior a 2.16 permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de un mensaje L2PT manipulado.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil_x2_firmware:1.00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"63D5F850-2020-4951-9D8A-1B50E4F8541C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil_x2_firmware:4.31:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"15FD9501-0A71-4060-898B-5D2CC101DE1E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:iij:seil\\\\/x2:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BF54D2DC-48BF-4E7D-BC33-1010B8DBF9E2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil\\\\%2fturbo_firmware:2.05:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"12D33318-9872-4757-9B6D-844A8FD34360\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil\\\\%2fturbo_firmware:2.15:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F463AD3-69F3-48EF-98E6-7F3BF06517A8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:iij:seil\\\\/turbo:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DC88F5F6-CB51-4676-91D6-69668229E675\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil\\\\%2fneu_2fe_plus_firmware:2.05:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC5F0F67-6961-478C-9895-7EFC2FD7CD2D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil\\\\%2fneu_2fe_plus_firmware:2.15:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5E159CF1-554D-4737-9506-59BFF0428C33\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:iij:seil\\\\/neu_2fe_plus:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFB4A421-197B-4654-B362-AEDA3ADADC33\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil\\\\%2fb1_firmware:1.00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"745A1DDE-27CA-4E82-9D7A-E6A11404E02E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil\\\\%2fb1_firmware:4.31:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7FE74E12-BDED-4459-89F9-18B0D621BF0F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:iij:seil\\\\/b1:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4BE3BBD4-FB2E-4543-9149-0452B26FAC31\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil\\\\%2fx86_firmware:1.00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"86111C25-1F23-43A0-A2C9-DADE78F16A0B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil\\\\%2fx86_firmware:2.81:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B1C5DA19-0661-4735-AE91-E65EB59850EC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:iij:seil\\\\/x86:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"477E1688-0CA2-4BD0-A29C-3239B760FA3C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil\\\\%2fx1_firmware:1.00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9F2F6546-4443-48EE-B29E-B2999A22E906\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:iij:seil\\\\%2fx1_firmware:4.31:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11EAE136-B926-4FFE-B799-C13356F1848F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:iij:seil\\\\/x1:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9A63E557-3BA6-4E0E-8597-BAA112B21DEF\"}]}]}],\"references\":[{\"url\":\"http://jvn.jp/en/jp/JVN43152129/index.html\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://jvndb.jvn.jp/jvndb/JVNDB-2013-000092\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.seil.jp/support/security/a01396.html\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://jvn.jp/en/jp/JVN43152129/index.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://jvndb.jvn.jp/jvndb/JVNDB-2013-000092\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.seil.jp/support/security/a01396.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…