CVE-2013-0655 (GCVE-0-2013-0655)
Vulnerability from cvelistv5
Published
2013-01-21 16:00
Modified
2024-09-17 00:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in-the-middle attackers to spoof updates, and consequently execute arbitrary code, by modifying the data stream on TCP port 80.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T14:33:05.445Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.schneider-electric.com/download/ww/en/details/29960967-SE-Software-Update-Utility-Vulnerability-Disclosure/?reference=SEVD-2013-009-01" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www2.schneider-electric.com/corporate/en/support/cybersecurity/viewer-news.page?c_filepath=/templatedata/Content/News/data/en/local/cybersecurity/general_information/2013/01/20130109_advisory_of_vulnerability_affecting_schneider_electric_s_software_upda.xml" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-13-016-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in-the-middle attackers to spoof updates, and consequently execute arbitrary code, by modifying the data stream on TCP port 80." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2013-01-21T16:00:00Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.schneider-electric.com/download/ww/en/details/29960967-SE-Software-Update-Utility-Vulnerability-Disclosure/?reference=SEVD-2013-009-01" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www2.schneider-electric.com/corporate/en/support/cybersecurity/viewer-news.page?c_filepath=/templatedata/Content/News/data/en/local/cybersecurity/general_information/2013/01/20130109_advisory_of_vulnerability_affecting_schneider_electric_s_software_upda.xml" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-13-016-01.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2013-0655", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in-the-middle attackers to spoof updates, and consequently execute arbitrary code, by modifying the data stream on TCP port 80." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.schneider-electric.com/download/ww/en/details/29960967-SE-Software-Update-Utility-Vulnerability-Disclosure/?reference=SEVD-2013-009-01", "refsource": "CONFIRM", "url": "http://www.schneider-electric.com/download/ww/en/details/29960967-SE-Software-Update-Utility-Vulnerability-Disclosure/?reference=SEVD-2013-009-01" }, { "name": "http://www2.schneider-electric.com/corporate/en/support/cybersecurity/viewer-news.page?c_filepath=/templatedata/Content/News/data/en/local/cybersecurity/general_information/2013/01/20130109_advisory_of_vulnerability_affecting_schneider_electric_s_software_upda.xml", "refsource": "CONFIRM", "url": "http://www2.schneider-electric.com/corporate/en/support/cybersecurity/viewer-news.page?c_filepath=/templatedata/Content/News/data/en/local/cybersecurity/general_information/2013/01/20130109_advisory_of_vulnerability_affecting_schneider_electric_s_software_upda.xml" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-13-016-01.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-13-016-01.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2013-0655", "datePublished": "2013-01-21T16:00:00Z", "dateReserved": "2012-12-19T00:00:00Z", "dateUpdated": "2024-09-17T00:51:21.342Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2013-0655\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2013-01-21T16:55:01.793\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in-the-middle attackers to spoof updates, and consequently execute arbitrary code, by modifying the data stream on TCP port 80.\"},{\"lang\":\"es\",\"value\":\"El cliente en Schneider Electric Software Update (SESU) Utility v1.0.x y v1.1.x no asegura que las actualizaciones tienen un origen v\u00e1lido, que permite ataques man-in-the-middle que burla actualizaciones, porl o que ejecuta c\u00f3digo arbitrario modificando los datos del puerto TCP 80\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:software_update_utility:1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"004C1A67-622F-4C51-9CF4-36E69EDDD7B0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:software_update_utility:1.0.13:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0A156B24-6E47-4BEE-B0AE-624F152DFB96\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:software_update_utility:1.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DC3E3B65-E9EB-4FEC-8908-6A1E13633246\"}]}]}],\"references\":[{\"url\":\"http://www.schneider-electric.com/download/ww/en/details/29960967-SE-Software-Update-Utility-Vulnerability-Disclosure/?reference=SEVD-2013-009-01\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-13-016-01.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://www2.schneider-electric.com/corporate/en/support/cybersecurity/viewer-news.page?c_filepath=/templatedata/Content/News/data/en/local/cybersecurity/general_information/2013/01/20130109_advisory_of_vulnerability_affecting_schneider_electric_s_software_upda.xml\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.schneider-electric.com/download/ww/en/details/29960967-SE-Software-Update-Utility-Vulnerability-Disclosure/?reference=SEVD-2013-009-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-13-016-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://www2.schneider-electric.com/corporate/en/support/cybersecurity/viewer-news.page?c_filepath=/templatedata/Content/News/data/en/local/cybersecurity/general_information/2013/01/20130109_advisory_of_vulnerability_affecting_schneider_electric_s_software_upda.xml\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…