CVE-2012-1802 (GCVE-0-2012-1802)
Vulnerability from cvelistv5
Published
2012-04-18 10:00
Modified
2024-08-06 19:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T19:08:38.499Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "81032",
"tags": [
"vdb-entry",
"x_refsource_OSVDB",
"x_transferred"
],
"url": "http://osvdb.org/81032"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-04-11T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2012-11-20T10:00:00",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"name": "81032",
"tags": [
"vdb-entry",
"x_refsource_OSVDB"
],
"url": "http://osvdb.org/81032"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2012-1802",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "81032",
"refsource": "OSVDB",
"url": "http://osvdb.org/81032"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
},
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2012-1802",
"datePublished": "2012-04-18T10:00:00",
"dateReserved": "2012-03-21T00:00:00",
"dateUpdated": "2024-08-06T19:08:38.499Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2012-1802\",\"sourceIdentifier\":\"cret@cert.org\",\"published\":\"2012-04-18T10:33:35.450\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de b\u00fafer en el servidor web integrado en el conmutador ethernet industrial Siemens Scalance X X414-3E antes de v3.7.1, X308-2M antes de v3.7.2, X-300EEC antes de v3.7.2, XR-300 antes de v3.7.2, y X-300 antes de v3.7.2 permite a atacantes remotos causar una denegaci\u00f3n de servicio (reinicio del dispositivo) o posiblemente ejecutar c\u00f3digo arbitrario a trav\u00e9s de una direcci\u00f3n URL incorrecta.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:C\",\"baseScore\":7.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x414-3e_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.7.0\",\"matchCriteriaId\":\"FB47C02A-0FD8-47A2-93F8-310A5E05E19F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x414-3e_firmware:1.2.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6212D6C3-A68D-41BA-929A-943A157B3BA7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.1.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"56338A9A-C59D-47D3-9AB4-18C53A75EDD5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"801D7741-8EBB-4A68-A77C-E26C304EB988\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EF4AB664-29DD-46F0-B136-8BD458430BD4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB8720F3-21D3-40C1-98A8-90E2EF6BBA52\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FFF99DC1-34B7-4AAA-BC33-5763B56EEA1B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"629D65C2-0D61-48BD-9C73-7794AC061756\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DDD5708A-0105-4129-B5A6-DAF0247ABE1F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B349A4F6-1FB0-433B-B512-883E580CFB27\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x414-3e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6645288F-F688-442A-8C56-17536BFAD4BE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.7.0\",\"matchCriteriaId\":\"EC42F509-F58D-4A65-9C31-26F0C7319076\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.1.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4020E0F4-E92A-442D-A703-CA8840B8D944\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"58E635A6-1AFF-4A34-87F3-F68571032448\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB1B5735-D3C0-445C-B7D5-A3099D1CE152\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AC54911E-C432-48FA-9551-9644422FFE14\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x-300eec_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.7.0\",\"matchCriteriaId\":\"6F13D012-86FA-4A41-8D18-94942A270DAA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x-300eec_firmware:3.5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB16E154-1E59-438F-9895-47260FDD7230\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x-300eec:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F2F32466-A411-4D69-864A-4434D3D5DB54\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.7.0\",\"matchCriteriaId\":\"FF530C3C-A126-4F6A-8010-E93352800598\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_xr-300_firmware:3.1.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AE3F5ED9-F357-430C-B277-B7EC0715A391\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_xr-300_firmware:3.5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"61FF9CF2-14CD-49BF-AC0B-0D2E0EDCF79F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"889CF2C0-EE6C-447F-85F1-005730EAD232\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.7.0\",\"matchCriteriaId\":\"F2000A16-E8A2-4E8E-A90F-4E0F62F3993C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x-300_firmware:2.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AF93BD72-2893-436D-A514-3C463C1AA428\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x-300_firmware:2.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"59323828-6A3A-48CD-B98C-64CD65829471\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x-300_firmware:3.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8C53B2B-BFFC-47D1-B935-FF85F5A4D3F1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x-300_firmware:3.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"054C0618-5CA9-43E4-A557-0064B8BB5B63\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6D5DF242-8FD0-467C-84D1-5207CC15D2D2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B16E873A-5D79-43B8-BB64-66B8079CFCC4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B2D0AB50-6F0B-4232-8C8E-1647410D362D\"}]}]}],\"references\":[{\"url\":\"http://osvdb.org/81032\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf\",\"source\":\"cret@cert.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf\",\"source\":\"cret@cert.org\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://osvdb.org/81032\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…