cnvd-2025-01697
Vulnerability from cnvd
Title
Siemens SIPROTEC 5文件访问限制不当漏洞
Description
SIPROTEC 5设备为变电站和其他应用领域提供一系列集成保护、控制、测量和自动化功能。 Siemens SIPROTEC 5存在文件访问限制不当漏洞,该漏洞源于设备未正确限制Web服务器对文件系统的访问,经过身份验证的远程攻击者可利用漏洞读取任意文件或设备的整个文件系统。
Severity
Formal description

除个别产品暂无漏洞修复方案外,厂商已为多个受影响的产品发布了新版本,并建议更新到最新版本,具体如下: 1、关于SIPROTEC 5 - CP050 Devices,请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109796884/ 2、关于SIPROTEC 5 - CP150 Devices,请升级至V9.80及以上版本: (1)SIPROTEC 5 7SA82 (CP150):https://support.industry.siemens.com/cs/ww/en/view/109757433/ (2)SIPROTEC 5 7SD82 (CP150):https://support.industry.siemens.com/cs/ww/en/view/109757433/ (3)SIPROTEC 5 7SJ81 (CP150):https://support.industry.siemens.com/cs/ww/en/view/109751934/ (4)SIPROTEC 5 7SJ82 (CP150):https://support.industry.siemens.com/cs/ww/en/view/109751934/ (5)SIPROTEC 5 7SK82 (CP150):https://support.industry.siemens.com/cs/ww/en/view/109757434/ (6)SIPROTEC 5 7SL82 (CP150):https://support.industry.siemens.com/cs/ww/en/view/109757433/ (7)SIPROTEC 5 7SX82 (CP150):https://support.industry.siemens.com/cs/ww/en/view/109768011/ (8)SIPROTEC 5 7SY82 (CP150):https://support.industry.siemens.com/cs/ww/en/view/109804070/ (9)SIPROTEC 5 7UT82 (CP150):https://support.industry.siemens.com/cs/ww/en/view/109757438/ 3、关于SIPROTEC 5 - CP100 Devices,目前暂无漏洞修复方案。 4、关于SIPROTEC 5 - CP300 Devices,具体如下: (1)SIPROTEC 5 6MD84 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109814150/ (2)SIPROTEC 5 6MD85 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757428/ (3)SIPROTEC 5 6MD86 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757428/ (4)SIPROTEC 5 6MD89 (CP300),目前暂无漏洞修复方案 (5)SIPROTEC 5 6MU85 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109765263/ (6)SIPROTEC 5 7KE85 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757430/ (7)SIPROTEC 5 7SA86 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757433/ (8)SIPROTEC 5 7SA87 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757433/ (9)SIPROTEC 5 7SD86 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757433/ (10)SIPROTEC 5 7SD87 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757433/ (11)SIPROTEC 5 7SJ85 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109751934/ (12)SIPROTEC 5 7SJ86 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757433/ (13)SIPROTEC 5 7SK85 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757434/ (14)SIPROTEC 5 7SL86 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757433/ (15)SIPROTEC 5 7SL87 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757433/ (16)SIPROTEC 5 7SS85 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757429/ (17)SIPROTEC 5 7ST85 (CP300),目前暂无漏洞修复方案 (18)SIPROTEC 5 7ST86 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109768428/ (19)SIPROTEC 5 7SX85 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109768011/ (20)SIPROTEC 5 7UM85 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757431/ (21)SIPROTEC 5 7UT85 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757438/ (22)SIPROTEC 5 7UT86 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757438/ (23)SIPROTEC 5 7UT87 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757438/ (24)SIPROTEC 5 7VE85 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109749865/ (25)SIPROTEC 5 7VK87 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109757433/ (26)SIPROTEC 5 7VU85 (CP300),请升级至V9.80及以上版本: https://support.industry.siemens.com/cs/ww/en/view/109800399/

Reference
https://cert-portal.siemens.com/productcert/html/ssa-194557.html
Impacted products
Name
['Siemens SIPROTEC 5 Compact 7SX800 (CP050) <V9.80', 'Siemens SIPROTEC 5 7SA82 (CP150) <V9.80', 'Siemens SIPROTEC 5 7SD82 (CP150) <V9.80', 'Siemens SIPROTEC 5 7SJ81 (CP150) <V9.80', 'Siemens SIPROTEC 5 7SJ82 (CP150) <V9.80', 'Siemens SIPROTEC 5 7SK82 (CP150) <V9.80', 'Siemens SIPROTEC 5 7SL82 (CP150) <V9.80', 'Siemens SIPROTEC 5 7SX82 (CP150) <V9.80', 'Siemens SIPROTEC 5 7SY82 (CP150) <V9.80', 'Siemens SIPROTEC 5 7UT82 (CP150) <V9.80', 'Siemens SIPROTEC 5 6MD84 (CP300) <V9.80', 'Siemens SIPROTEC 5 6MD85 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 6MD86 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 6MD89 (CP300) >=V7.80', 'Siemens SIPROTEC 5 6MU85 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7KE85 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7SA86 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7SA87 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7SD86 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7SD87 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7SJ85 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7SJ86 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7SK85 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7SL86 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7SL87 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7SS85 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7ST85 (CP300)', 'Siemens SIPROTEC 5 7ST86 (CP300) <V9.80', 'Siemens SIPROTEC 5 7SX85 (CP300) <V9.80', 'Siemens SIPROTEC 5 7UM85 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7UT85 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7UT86 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7UT87 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7VE85 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7VK87 (CP300) >=V7.80,<V9.80', 'Siemens SIPROTEC 5 7VU85 (CP300) <V9.80', 'Siemens SIPROTEC 5 7SA82 (CP100) >=V7.80', 'Siemens SIPROTEC 5 7SD82 (CP100) >=V7.80', 'Siemens SIPROTEC 5 7SJ81 (CP100) >=V7.80', 'Siemens SIPROTEC 5 7SJ82 (CP100) >=V7.80', 'Siemens SIPROTEC 5 7SL82 (CP100) >=V7.80', 'Siemens SIPROTEC 5 7UT82 (CP100) >=V7.80', 'Siemens SIPROTEC 5 7SK82 (CP100) >=V7.80']
Show details on source website


{
  "cves": {
    "cve": {
      "cveNumber": "CVE-2024-53649"
    }
  },
  "description": "SIPROTEC 5\u8bbe\u5907\u4e3a\u53d8\u7535\u7ad9\u548c\u5176\u4ed6\u5e94\u7528\u9886\u57df\u63d0\u4f9b\u4e00\u7cfb\u5217\u96c6\u6210\u4fdd\u62a4\u3001\u63a7\u5236\u3001\u6d4b\u91cf\u548c\u81ea\u52a8\u5316\u529f\u80fd\u3002\n\nSiemens SIPROTEC 5\u5b58\u5728\u6587\u4ef6\u8bbf\u95ee\u9650\u5236\u4e0d\u5f53\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u8bbe\u5907\u672a\u6b63\u786e\u9650\u5236Web\u670d\u52a1\u5668\u5bf9\u6587\u4ef6\u7cfb\u7edf\u7684\u8bbf\u95ee\uff0c\u7ecf\u8fc7\u8eab\u4efd\u9a8c\u8bc1\u7684\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u8bfb\u53d6\u4efb\u610f\u6587\u4ef6\u6216\u8bbe\u5907\u7684\u6574\u4e2a\u6587\u4ef6\u7cfb\u7edf\u3002",
  "formalWay": "\u9664\u4e2a\u522b\u4ea7\u54c1\u6682\u65e0\u6f0f\u6d1e\u4fee\u590d\u65b9\u6848\u5916\uff0c\u5382\u5546\u5df2\u4e3a\u591a\u4e2a\u53d7\u5f71\u54cd\u7684\u4ea7\u54c1\u53d1\u5e03\u4e86\u65b0\u7248\u672c\uff0c\u5e76\u5efa\u8bae\u66f4\u65b0\u5230\u6700\u65b0\u7248\u672c\uff0c\u5177\u4f53\u5982\u4e0b\uff1a\r\n1\u3001\u5173\u4e8eSIPROTEC 5 - CP050 Devices\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109796884/\r\n2\u3001\u5173\u4e8eSIPROTEC 5 - CP150 Devices\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\n\uff081\uff09SIPROTEC 5 7SA82 (CP150)\uff1ahttps://support.industry.siemens.com/cs/ww/en/view/109757433/\r\n\uff082\uff09SIPROTEC 5 7SD82 (CP150)\uff1ahttps://support.industry.siemens.com/cs/ww/en/view/109757433/\r\n\uff083\uff09SIPROTEC 5 7SJ81 (CP150)\uff1ahttps://support.industry.siemens.com/cs/ww/en/view/109751934/\r\n\uff084\uff09SIPROTEC 5 7SJ82 (CP150)\uff1ahttps://support.industry.siemens.com/cs/ww/en/view/109751934/\r\n\uff085\uff09SIPROTEC 5 7SK82 (CP150)\uff1ahttps://support.industry.siemens.com/cs/ww/en/view/109757434/\r\n\uff086\uff09SIPROTEC 5 7SL82 (CP150)\uff1ahttps://support.industry.siemens.com/cs/ww/en/view/109757433/\r\n\uff087\uff09SIPROTEC 5 7SX82 (CP150)\uff1ahttps://support.industry.siemens.com/cs/ww/en/view/109768011/\r\n\uff088\uff09SIPROTEC 5 7SY82 (CP150)\uff1ahttps://support.industry.siemens.com/cs/ww/en/view/109804070/\r\n\uff089\uff09SIPROTEC 5 7UT82 (CP150)\uff1ahttps://support.industry.siemens.com/cs/ww/en/view/109757438/\r\n3\u3001\u5173\u4e8eSIPROTEC 5 - CP100 Devices\uff0c\u76ee\u524d\u6682\u65e0\u6f0f\u6d1e\u4fee\u590d\u65b9\u6848\u3002\r\n4\u3001\u5173\u4e8eSIPROTEC 5 - CP300 Devices\uff0c\u5177\u4f53\u5982\u4e0b\uff1a\r\n\uff081\uff09SIPROTEC 5 6MD84 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109814150/\r\n\uff082\uff09SIPROTEC 5 6MD85 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757428/\r\n\uff083\uff09SIPROTEC 5 6MD86 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757428/\r\n\uff084\uff09SIPROTEC 5 6MD89 (CP300)\uff0c\u76ee\u524d\u6682\u65e0\u6f0f\u6d1e\u4fee\u590d\u65b9\u6848\r\n\uff085\uff09SIPROTEC 5 6MU85 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109765263/\r\n\uff086\uff09SIPROTEC 5 7KE85 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757430/\r\n\uff087\uff09SIPROTEC 5 7SA86 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757433/\r\n\uff088\uff09SIPROTEC 5 7SA87 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757433/\r\n\uff089\uff09SIPROTEC 5 7SD86 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757433/\r\n\uff0810\uff09SIPROTEC 5 7SD87 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757433/\r\n\uff0811\uff09SIPROTEC 5 7SJ85 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109751934/\r\n\uff0812\uff09SIPROTEC 5 7SJ86 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757433/\r\n\uff0813\uff09SIPROTEC 5 7SK85 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757434/\r\n\uff0814\uff09SIPROTEC 5 7SL86 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757433/\r\n\uff0815\uff09SIPROTEC 5 7SL87 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757433/\r\n\uff0816\uff09SIPROTEC 5 7SS85 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757429/\r\n\uff0817\uff09SIPROTEC 5 7ST85 (CP300)\uff0c\u76ee\u524d\u6682\u65e0\u6f0f\u6d1e\u4fee\u590d\u65b9\u6848\r\n\uff0818\uff09SIPROTEC 5 7ST86 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109768428/\r\n\uff0819\uff09SIPROTEC 5 7SX85 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109768011/\r\n\uff0820\uff09SIPROTEC 5 7UM85 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757431/\r\n\uff0821\uff09SIPROTEC 5 7UT85 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757438/\r\n\uff0822\uff09SIPROTEC 5 7UT86 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757438/\r\n\uff0823\uff09SIPROTEC 5 7UT87 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757438/\r\n\uff0824\uff09SIPROTEC 5 7VE85 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109749865/\r\n\uff0825\uff09SIPROTEC 5 7VK87 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109757433/\r\n\uff0826\uff09SIPROTEC 5 7VU85 (CP300)\uff0c\u8bf7\u5347\u7ea7\u81f3V9.80\u53ca\u4ee5\u4e0a\u7248\u672c\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109800399/",
  "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
  "number": "CNVD-2025-01697",
  "openTime": "2025-01-17",
  "products": {
    "product": [
      "Siemens SIPROTEC 5 Compact 7SX800 (CP050) \u003cV9.80",
      "Siemens SIPROTEC 5 7SA82 (CP150) \u003cV9.80",
      "Siemens SIPROTEC 5 7SD82 (CP150) \u003cV9.80",
      "Siemens SIPROTEC 5 7SJ81 (CP150) \u003cV9.80",
      "Siemens SIPROTEC 5 7SJ82 (CP150) \u003cV9.80",
      "Siemens SIPROTEC 5 7SK82 (CP150) \u003cV9.80",
      "Siemens SIPROTEC 5 7SL82 (CP150) \u003cV9.80",
      "Siemens SIPROTEC 5 7SX82 (CP150) \u003cV9.80",
      "Siemens SIPROTEC 5 7SY82 (CP150) \u003cV9.80",
      "Siemens SIPROTEC 5 7UT82 (CP150) \u003cV9.80",
      "Siemens SIPROTEC 5 6MD84 (CP300) \u003cV9.80",
      "Siemens SIPROTEC 5 6MD85 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 6MD86 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 6MD89 (CP300) \u003e=V7.80",
      "Siemens SIPROTEC 5 6MU85 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7KE85 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7SA86 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7SA87 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7SD86 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7SD87 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7SJ85 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7SJ86 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7SK85 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7SL86 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7SL87 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7SS85 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7ST85 (CP300)",
      "Siemens SIPROTEC 5 7ST86 (CP300) \u003cV9.80",
      "Siemens SIPROTEC 5 7SX85 (CP300) \u003cV9.80",
      "Siemens SIPROTEC 5 7UM85 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7UT85 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7UT86 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7UT87 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7VE85 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7VK87 (CP300) \u003e=V7.80\uff0c\u003cV9.80",
      "Siemens SIPROTEC 5 7VU85 (CP300) \u003cV9.80",
      "Siemens SIPROTEC 5 7SA82 (CP100) \u003e=V7.80",
      "Siemens SIPROTEC 5 7SD82 (CP100) \u003e=V7.80",
      "Siemens SIPROTEC 5 7SJ81 (CP100) \u003e=V7.80",
      "Siemens SIPROTEC 5 7SJ82 (CP100) \u003e=V7.80",
      "Siemens SIPROTEC 5 7SL82 (CP100) \u003e=V7.80",
      "Siemens SIPROTEC 5 7UT82 (CP100) \u003e=V7.80",
      "Siemens SIPROTEC 5 7SK82 (CP100) \u003e=V7.80"
    ]
  },
  "referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-194557.html",
  "serverity": "\u9ad8",
  "submitTime": "2025-01-14",
  "title": "Siemens SIPROTEC 5\u6587\u4ef6\u8bbf\u95ee\u9650\u5236\u4e0d\u5f53\u6f0f\u6d1e"
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…