cnvd-2018-17064
Vulnerability from cnvd
Title: Schneider Electric PowerLogic PM5560跨站脚本漏洞
Description:
Schneider Electric PowerLogic PM5560是法国施耐德电气(Schneider Electric)公司的一款多功能功率计量电表设备。
使用2.5.4之前版本固件的Schneider Electric PowerLogic PM5560中存在跨站脚本漏洞。远程攻击者可通过操纵输入利用该漏洞执行JavaScript代码。
Severity: 高
Patch Name: Schneider Electric PowerLogic PM5560跨站脚本漏洞的补丁
Patch Description:
Schneider Electric PowerLogic PM5560是法国施耐德电气(Schneider Electric)公司的一款多功能功率计量电表设备。
使用2.5.4之前版本固件的Schneider Electric PowerLogic PM5560中存在跨站脚本漏洞。远程攻击者可通过操纵输入利用该漏洞执行JavaScript代码。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description:
厂商已发布了漏洞修复程序,请及时关注更新: https://www.schneider-electric.com/en/download/document/PM5560_PM5563_V2.5.4_Release/
Reference: https://ics-cert.us-cert.gov/advisories/ICSA-18-240-03
Impacted products
Name | Schneider Electric PowerLogic PM5560 2.5.4 |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2018-7795" } }, "description": "Schneider Electric PowerLogic PM5560\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u591a\u529f\u80fd\u529f\u7387\u8ba1\u91cf\u7535\u8868\u8bbe\u5907\u3002\r\n\r\n\u4f7f\u75282.5.4\u4e4b\u524d\u7248\u672c\u56fa\u4ef6\u7684Schneider Electric PowerLogic PM5560\u4e2d\u5b58\u5728\u8de8\u7ad9\u811a\u672c\u6f0f\u6d1e\u3002\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u901a\u8fc7\u64cd\u7eb5\u8f93\u5165\u5229\u7528\u8be5\u6f0f\u6d1e\u6267\u884cJavaScript\u4ee3\u7801\u3002", "discovererName": "unknown", "formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0:\r\nhttps://www.schneider-electric.com/en/download/document/PM5560_PM5563_V2.5.4_Release/", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2018-17064", "openTime": "2018-08-31", "patchDescription": "Schneider Electric PowerLogic PM5560\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u591a\u529f\u80fd\u529f\u7387\u8ba1\u91cf\u7535\u8868\u8bbe\u5907\u3002\r\n\r\n\u4f7f\u75282.5.4\u4e4b\u524d\u7248\u672c\u56fa\u4ef6\u7684Schneider Electric PowerLogic PM5560\u4e2d\u5b58\u5728\u8de8\u7ad9\u811a\u672c\u6f0f\u6d1e\u3002\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u901a\u8fc7\u64cd\u7eb5\u8f93\u5165\u5229\u7528\u8be5\u6f0f\u6d1e\u6267\u884cJavaScript\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Schneider Electric PowerLogic PM5560\u8de8\u7ad9\u811a\u672c\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": "Schneider Electric PowerLogic PM5560 2.5.4" }, "referenceLink": "https://ics-cert.us-cert.gov/advisories/ICSA-18-240-03", "serverity": "\u9ad8", "submitTime": "2018-08-30", "title": "Schneider Electric PowerLogic PM5560\u8de8\u7ad9\u811a\u672c\u6f0f\u6d1e" }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…