cnvd-2017-05430
Vulnerability from cnvd
Title
Schneider Electric homeLYnk Controller安全绕过漏洞
Description
Schneider Electric homeLYnk Controller是一款逻辑控制器。
Schneider Electric homeLYnk Controller 1.5.0之前的所有版本中存在安全绕过漏洞。远程攻击者利用该漏洞获得敏感信息。
Severity
高
VLAI Severity ?
Patch Name
Schneider Electric homeLYnk Controller安全绕过漏洞的补丁
Patch Description
Schneider Electric homeLYnk Controller是一款逻辑控制器。
Schneider Electric homeLYnk Controller 1.5.0之前的所有版本中存在安全绕过漏洞。远程攻击者利用该漏洞获得敏感信息。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description
用户可参考如下厂商提供的安全补丁以修复该漏洞: http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-02
Reference
http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-02
https://nvd.nist.gov/vuln/detail/CVE-2017-7689
Impacted products
| Name | Schneider Electric homeLYnk Controller <1.5.0 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2017-7689",
"cveUrl": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-7689"
}
},
"description": "Schneider Electric homeLYnk Controller\u662f\u4e00\u6b3e\u903b\u8f91\u63a7\u5236\u5668\u3002\r\n\r\nSchneider Electric homeLYnk Controller 1.5.0\u4e4b\u524d\u7684\u6240\u6709\u7248\u672c\u4e2d\u5b58\u5728\u5b89\u5168\u7ed5\u8fc7\u6f0f\u6d1e\u3002\u8fdc\u7a0b\u653b\u51fb\u8005\u5229\u7528\u8be5\u6f0f\u6d1e\u83b7\u5f97\u654f\u611f\u4fe1\u606f\u3002",
"discovererName": "unknown",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u5382\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u8865\u4e01\u4ee5\u4fee\u590d\u8be5\u6f0f\u6d1e\uff1a\r\nhttp://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-02",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2017-05430",
"openTime": "2017-04-26",
"patchDescription": "Schneider Electric homeLYnk Controller\u662f\u4e00\u6b3e\u903b\u8f91\u63a7\u5236\u5668\u3002\r\n\r\nSchneider Electric homeLYnk Controller 1.5.0\u4e4b\u524d\u7684\u6240\u6709\u7248\u672c\u4e2d\u5b58\u5728\u5b89\u5168\u7ed5\u8fc7\u6f0f\u6d1e\u3002\u8fdc\u7a0b\u653b\u51fb\u8005\u5229\u7528\u8be5\u6f0f\u6d1e\u83b7\u5f97\u654f\u611f\u4fe1\u606f\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric homeLYnk Controller\u5b89\u5168\u7ed5\u8fc7\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Schneider Electric homeLYnk Controller \u003c1.5.0"
},
"referenceLink": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-02\r\nhttps://nvd.nist.gov/vuln/detail/CVE-2017-7689",
"serverity": "\u9ad8",
"submitTime": "2017-04-13",
"title": "Schneider Electric homeLYnk Controller\u5b89\u5168\u7ed5\u8fc7\u6f0f\u6d1e"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…